31 resultados para sensor-based control
Resumo:
Contention-based MAC protocols follow periodic listen/sleep cycles. These protocols face the problem of virtual clustering if different unsynchronized listen/sleep schedules occur in the network, which has been shown to happen in wireless sensor networks. To interconnect these virtual clusters, border nodes maintaining all respective listen/sleep schedules are required. However, this is a waste of energy, if locally a common schedule can be determined. We propose to achieve local synchronization with a mechanism that is similar to gravitation. Clusters represent the mass, whereas synchronization messages sent by each cluster represent the gravitation force of the according cluster. Due to the mutual attraction caused by the clusters, all clusters merge finally. The exchange of synchronization messages itself is not altered by LACAS. Accordingly, LACAS introduces no overhead. Only a not yet used property of synchronization mechanisms is exploited.
Resumo:
In this paper, an Insulin Infusion Advisory System (IIAS) for Type 1 diabetes patients, which use insulin pumps for the Continuous Subcutaneous Insulin Infusion (CSII) is presented. The purpose of the system is to estimate the appropriate insulin infusion rates. The system is based on a Non-Linear Model Predictive Controller (NMPC) which uses a hybrid model. The model comprises a Compartmental Model (CM), which simulates the absorption of the glucose to the blood due to meal intakes, and a Neural Network (NN), which simulates the glucose-insulin kinetics. The NN is a Recurrent NN (RNN) trained with the Real Time Recurrent Learning (RTRL) algorithm. The output of the model consists of short term glucose predictions and provides input to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. For the development and the evaluation of the IIAS, data generated from a Mathematical Model (MM) of a Type 1 diabetes patient have been used. The proposed control strategy is evaluated at multiple meal disturbances, various noise levels and additional time delays. The results indicate that the implemented IIAS is capable of handling multiple meals, which correspond to realistic meal profiles, large noise levels and time delays.
Resumo:
The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.
Resumo:
The development and evaluation of new algorithms and protocols for Wireless Multimedia Sensor Networks (WMSNs) are usually supported by means of a discrete event network simulator, where OMNeT++ is one of the most important ones. However, experiments involving multimedia transmission, video flows with different characteristics, genres, group of pictures lengths, and coding techniques must be evaluated based also on Quality of Experience (QoE) metrics to reflect the user's perception. Such experiments require the evaluation of video-related information, i.e., frame type, received/lost, delay, jitter, decoding errors, as well as inter and intra-frame dependency of received/distorted videos. However, existing OMNeT++ frameworks for WMSNs do not support video transmissions with QoE-awareness, neither a large set of mobility traces to enable evaluations under different multimedia/mobile situations. In this paper, we propose a Mobile MultiMedia Wireless Sensor Network OMNeT++ framework (M3WSN) to support transmission, control and evaluation of real video sequences in mobile WMSNs.
Resumo:
PURPOSE Patients with Alzheimer's disease (AD) have an increased risk of developing seizures or epilepsy. Little is known about the role of risk factors and about the risk of developing seizures/epilepsy in patients with vascular dementia (VD). The aim of this study was to assess incidence rates (IRs) of seizures/epilepsy in patients with AD, VD, or without dementia, and to identify potential risk factors of seizures or epilepsy. METHODS We conducted a follow-up study with a nested case-control analysis using the United Kingdom-based General Practice Research Database (GPRD). We identified patients aged ≥65 years with an incident diagnosis of AD or VD between 1998 and 2008 and a matched comparison group of dementia-free patients. Conditional logistic regression was used to estimate the odds ratio (OR) with a 95% confidence interval (CI) of developing seizures/epilepsy in patients with AD or VD, stratified by age at onset and duration of dementia as well as by use of antidementia drugs. KEY FINDINGS Among 7,086 cases with AD, 4,438 with VD, and 11,524 matched dementia-free patients, we identified 180 cases with an incident diagnosis of seizures/epilepsy. The IRs of epilepsy/seizures for patients with AD or VD were 5.6/1,000 person-years (py) (95% CI 4.6-6.9) and 7.5/1,000 py (95% CI 5.7-9.7), respectively, and 0.8/1,000 py (95% CI 0.6-1.1) in the dementia-free group. In the nested case-control analysis, patients with longer standing (≥3 years) AD had a slightly higher risk of developing seizures or epilepsy than those with a shorter disease duration, whereas in patients with VD the contrary was observed. SIGNIFICANCE Seizures or epilepsy were substantially more common in patients with AD and VD than in dementia-free patients. The role of disease duration as a risk factor for seizures/epilepsy seems to differ between AD and VD.
Resumo:
RESTful services gained a lot of attention recently, even in the enterprise world, which is traditionally more web-service centric. Data centric RESfFul services, as previously mainly known in web environments, established themselves as a second paradigm complementing functional WSDL-based SOA. In the Internet of Things, and in particular when talking about sensor motes, the Constraint Application Protocol (CoAP) is currently in the focus of both research and industry. In the enterprise world a protocol called OData (Open Data Protocol) is becoming the future RESTful data access standard. To integrate sensor motes seamlessly into enterprise networks, an embedded OData implementation on top of CoAP is desirable, not requiring an intermediary gateway device. In this paper we introduce and evaluate an embedded OData implementation. We evaluate the OData protocol in terms of performance and energy consumption, considering different data encodings, and compare it to a pure CoAP implementation. We were able to demonstrate that the additional resources needed for an OData/JSON implementation are reasonable when aiming for enterprise interoperability, where OData is suggested to solve both the semantic and technical interoperability problems we have today when connecting systems
Resumo:
OBJECTIVES It is still debated if pre-existing minority drug-resistant HIV-1 variants (MVs) affect the virological outcomes of first-line NNRTI-containing ART. METHODS This Europe-wide case-control study included ART-naive subjects infected with drug-susceptible HIV-1 as revealed by population sequencing, who achieved virological suppression on first-line ART including one NNRTI. Cases experienced virological failure and controls were subjects from the same cohort whose viraemia remained suppressed at a matched time since initiation of ART. Blinded, centralized 454 pyrosequencing with parallel bioinformatic analysis in two laboratories was used to identify MVs in the 1%-25% frequency range. ORs of virological failure according to MV detection were estimated by logistic regression. RESULTS Two hundred and sixty samples (76 cases and 184 controls), mostly subtype B (73.5%), were used for the analysis. Identical MVs were detected in the two laboratories. 31.6% of cases and 16.8% of controls harboured pre-existing MVs. Detection of at least one MV versus no MVs was associated with an increased risk of virological failure (OR = 2.75, 95% CI = 1.35-5.60, P = 0.005); similar associations were observed for at least one MV versus no NRTI MVs (OR = 2.27, 95% CI = 0.76-6.77, P = 0.140) and at least one MV versus no NNRTI MVs (OR = 2.41, 95% CI = 1.12-5.18, P = 0.024). A dose-effect relationship between virological failure and mutational load was found. CONCLUSIONS Pre-existing MVs more than double the risk of virological failure to first-line NNRTI-based ART.
Resumo:
OBJECTIVE Use of diuretics has been associated with an increased risk of gout. Data on different types of diuretics are scarce. We undertook this study to investigate the association between use of loop diuretics, thiazide or thiazide-like diuretics, and potassium-sparing agents and the risk of developing incident gout. METHODS We conducted a retrospective population-based case-control analysis using the General Practice Research Database established in the UK. We identified case patients who were diagnosed as having incident gout between 1990 and 2010. One control patient was matched to each case patient for age, sex, general practice, calendar time, and years of active history in the database. We used conditional logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (95% CIs), and we adjusted for potential confounders. RESULTS We identified 91,530 incident cases of gout and the same number of matched controls. Compared to past use of diuretics from each respective drug class, adjusted ORs for current use of loop diuretics, thiazide diuretics, thiazide-like diuretics, and potassium-sparing diuretics were 2.64 (95% CI 2.47-2.83), 1.70 (95% CI 1.62-1.79), 2.30 (95% CI 1.95-2.70), and 1.06 (95% CI 0.91-1.23), respectively. Combined use of loop diuretics and thiazide diuretics was associated with the highest relative risk estimates of gout (adjusted OR 4.65 [95% CI 3.51-6.16]). Current use of calcium channel blockers or losartan slightly attenuated the risk of gout in patients who took diuretics. CONCLUSION Use of loop diuretics, thiazide diuretics, and thiazide-like diuretics was associated with an increased risk of incident gout, although use of potassium-sparing agents was not.
Resumo:
OBJECTIVE The aim of this study was to explore the risk of incident gout in patients with type 2 diabetes mellitus (T2DM) in association with diabetes duration, diabetes severity and antidiabetic drug treatment. METHODS We conducted a case-control study in patients with T2DM using the UK-based Clinical Practice Research Datalink (CPRD). We identified case patients aged ≥18 years with an incident diagnosis of gout between 1990 and 2012. We matched to each case patient one gout-free control patient. We used conditional logistic regression analysis to calculate adjusted ORs (adj. ORs) with 95% CIs and adjusted our analyses for important potential confounders. RESULTS The study encompassed 7536 T2DM cases with a first-time diagnosis of gout. Compared to a diabetes duration <1 year, prolonged diabetes duration (1-3, 3-6, 7-9 and ≥10 years) was associated with decreased adj. ORs of 0.91 (95% CI 0.79 to 1.04), 0.76 (95% CI 0.67 to 0.86), 0.70 (95% CI 0.61 to 0.86), and 0.58 (95% CI 0.51 to 0.66), respectively. Compared to a reference A1C level of <7%, the risk estimates of increasing A1C levels (7.0-7.9, 8.0-8.9 and ≥9%) steadily decreased with adj. ORs of 0.79 (95% CI 0.72 to 0.86), 0.63 (95% CI 0.55 to 0.72), and 0.46 (95% CI 0.40 to 0.53), respectively. Neither use of insulin, metformin, nor sulfonylureas was associated with an altered risk of incident gout. CONCLUSIONS Increased A1C levels, but not use of antidiabetic drugs, was associated with a decreased risk of incident gout among patients with T2DM.
Resumo:
OBJECTIVE This study aims to assess the odds of developing incident gout in association with the use of postmenopausal estrogen-progestogen therapy, according to type, timing, duration, and route of administration of estrogen-progestogen therapy. METHODS We conducted a retrospective population-based case-control analysis using the United Kingdom-based Clinical Practice Research Datalink. We identified women (aged 45 y or older) who had a first-time diagnosis of gout recorded between 1990 and 2010. We matched one female control with each case on age, general practice, calendar time, and years of active history in the database. We used multivariate conditional logistic regression to calculate odds ratios (ORs) with 95% CIs (adjusted for confounders). RESULTS The adjusted OR for gout with current use of oral formulations of opposed estrogens (estrogen-progestogen) was 0.69 (95% CI, 0.56-0.86) compared with never use. Current use was associated with a decreased OR for gout in women without renal failure (adjusted OR, 0.71; 95% CI, 0.57-0.87) and hypertension (adjusted OR, 0.62; 95% CI, 0.44-0.87) compared with never use. Tibolone was associated with a decreased OR for gout (adjusted OR, 0.77; 95% CI, 0.63-0.95) compared with never use. Estrogens alone did not alter the OR for gout. CONCLUSIONS Current use of oral opposed estrogens, but not unopposed estrogens, is associated with a decreased OR for incident gout in women without renal failure and is more pronounced in women with hypertension. Use of tibolone is associated with a decreased OR for incident gout. The decreased OR for gout may be related to the progestogen component rather than the estrogen component.