36 resultados para radius of curvature measurement
Resumo:
During general anesthesia drugs are administered to provide hypnosis, ensure analgesia, and skeletal muscle relaxation. In this paper, the main components of a newly developed controller for skeletal muscle relaxation are described. Muscle relaxation is controlled by administration of neuromuscular blocking agents. The degree of relaxation is assessed by supramaximal train-of-four stimulation of the ulnar nerve and measuring the electromyogram response of the adductor pollicis muscle. For closed-loop control purposes, a physiologically based pharmacokinetic and pharmacodynamic model of the neuromuscular blocking agent mivacurium is derived. The model is used to design an observer-based state feedback controller. Contrary to similar automatic systems described in the literature this controller makes use of two different measures obtained in the train-of-four measurement to maintain the desired level of relaxation. The controller is validated in a clinical study comparing the performance of the controller to the performance of the anesthesiologist. As presented, the controller was able to maintain a preselected degree of muscle relaxation with excellent precision while minimizing drug administration. The controller performed at least equally well as the anesthesiologist.
Resumo:
BACKGROUND: Calcaneonavicular coalitions (CNC) have been reported to be associated with anatomical aberrations of either the calcaneus and/or navicular bones. These morphological abnormalities may complicate accurate surgical resection. Three-dimensional analysis of spatial orientation and morphological characteristics may help in preoperative planning of resection. MATERIALS AND METHODS: Sixteen feet with a diagnosis of CNC were evaluated by means of 3-D CT modeling. Three angles were defined that were expressed in relation to one reproducible landmark (lateral border of the calcaneus): the dorsoplantar inclination, anteroposterior inclination, and socket angle. The depth and width of the coalitions were measured and calculated to obtain the estimated contact surface. Three-dimensional reconstructions of the calcanei served to evaluate the presence, distortion or absence of the anterior calcaneal facet and presence of a navicular beak. The interrater correlations were assessed in order to obtain values for the accuracy of the measurement methods. Sixteen normal feet were used as controls for comparison of the socket angle; anatomy of the anterior calcaneal facet and navicular beak as well. RESULTS: The dorsoplantar inclination angle averaged 50 degrees (+/-17), the anteroposterior inclination angle 64 degrees (+/-15), and the pathologic socket angle 98 degrees (+/-11). The average contact area was 156 mm(2). Ninety-four percent of all patients in the CNC group revealed a plantar navicular beak. In 50% of those patients the anterior calcaneal facet was replaced by the navicular portion and in 44% the facet was totally missing. In contrast, the socket angle in the control group averaged 77 degrees (+/-18), which was found to be statistically different than the CNC group (p = 0.0004). Only 25% of the patients in the control group had a plantar navicular beak. High, statistically significant interrater correlations were found for all measured angles. CONCLUSION: Computer-aided CT analysis and reconstructions help to determine the spatial orientations of CNC in space and provide useful information in order to anticipate morphological abnormalities of the calcaneus and navicular.
Resumo:
The value of measurements of eicosanoids in exhaled breath condensate (EBC) for the evaluation of childhood asthma is still inconclusive most likely because of the limited value of the methods used. In this case-control study in 48 asthmatic and 20 healthy children, we aimed to characterize the baseline profile of the inflammatory mediators cysteinyl leukotrienes (cysLTs), 9(alpha)11(beta)PGF(2), PGE(2), PGF(2alpha), 8-isoprostane (8-iso-PGF(2alpha)) within EBC in asthmatic compared with healthy children using new methods. In addition, we investigated their relation to other inflammatory markers. The assessment included collection of EBC, measurement of fractional exhaled nitric oxide (FE(NO)) and evaluation of urinary excretion of leukotriene E(4.) cysLTs were measured directly in EBC by radioimmunoassay and prostanoids were measured using gas chromatography negative-ion chemical ionization mass spectrometry. Only cysLT levels were significantly higher in asthmatic compared with healthy children (p = 0.002). No significant differences in cysLTs were found between steroid naïve and patients receiving inhaled corticosteroids. In contrast, FE(NO) was significantly higher in steroid naïve compared with steroid-treated asthmatic and healthy children (p = 0.04 and 0.024, respectively). The diagnostic accuracy of cysLTs in EBC for asthma was 73.6% for the whole group and 78.2% for steroid-naïve asthmatic children. The accuracy to classify asthmatic for FE(NO) was poor (62.9%) for the whole group, but improved to 79.9% when only steroid-naïve asthmatic children were taken into consideration. cysLTs in EBC is an inflammatory marker which distinguishes asthmatics, as a whole group, from healthy children.
Resumo:
BACKGROUND: Renovascular vasoconstriction in patients with hepatorenal syndrome can be quantified by the renal arterial resistance index (RI). We investigated the value of RI measurement in detection of renal function impairment in patients with different stages of chronic liver disease. METHODS: Subjects were divided into 4 groups containing 21 patients with liver cirrhosis and ascites, 25 patients with liver cirrhosis without ascites, 35 patients with fatty liver disease and 78 control subjects. All patients underwent abdominal ultrasound examination with renal RI measurement and correlation with laboratory results for renal function. RESULTS: RI was significantly higher in ascitic patients compared to non-ascitic patients (0.74 vs. 0.67, p<0.01) and in non-ascitic patients with liver cirrhosis than in control subjects (0.67 vs. 0.62, p<0.01). 48% (19/40) of patients with liver cirrhosis and normal serum creatinine concentration showed elevated RI levels. There were no significant differences in RI levels between patients with fatty liver disease and controls (0.63 vs. 0.62). CONCLUSIONS: Intrarenal RI measurement is a predictor of renal vasoconstriction and serves to detect early renal function impairment in cirrhotic patients. The diagnosis of elevated RI may be taken into account in the clinical management of these patients.
Resumo:
The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechanical parameters of the spinal segment. Investigation of the viscoelastic properties as well as the dynamic spinal stiffness was performed during a minimally invasive procedure (microdiscectomy) on five patients. Measurements were performed intraoperatively and the protocol consisted of a dynamic part, where spinal stiffness was computed, and a static part, where force relaxation of the segment under constant elongation was studied. The repeatability of the measurement procedure was demonstrated with five replicated tests. The spinal segment tissues were found to have viscoelastic properties. Preliminary tests confirmed a decrease in stiffness after decompression surgery. Patients with non-relaxed muscles showed higher stiffness and relaxation rate compared to patients with relaxed muscles, which can be explained by the contraction and relaxation reflex of muscles under fast and then static elongation. The results show the usefulness of the biomechanical characterization of the human lumbar spinal segment to improve the understanding of the contribution of individual anatomical structures to spinal stability.
Resumo:
Eight premature infants ventilated for hyaline membrane disease and enrolled in the OSIRIS surfactant trial were studied. Lung mechanics, gas exchange [PaCO2, arterial/alveolar PO2 ratio (a/A ratio)], and ventilator settings were determined 20 minutes before and 20 minutes after the end of Exosurf instillation, and subsequently at 12-24 hour intervals. Respiratory system compliance (Crs) and resistance (Rrs) were measured by means of the single breath occlusion method. After surfactant instillation there were no significant immediate changes in PaCO2 (36 vs. 37 mmHg), a/A ratio (0.23 vs. 0.20), Crs (0.32 vs. 0.31 mL/cm H2O/kg), and Rrs (0.11 vs. 0.16 cmH2O/mL/s) (pooled data of 18 measurement pairs). During the clinical course, mean a/A ratio improved significantly each time from 0.17 (time 0) to 0.29 (time 12-13 hours), to 0.39 (time 24-36 hours) and to 0.60 (time 48-61 hours), although mean airway pressure was reduced substantially. Mean Crs increased significantly from 0.28 mL/cmH2O/kg (time 0) to 0.38 (time 12-13 hours), to 0.37 (time 24-38 hours), and to 0.52 (time 48-61 hours), whereas mean Rrs increased from 0.10 cm H2O/mL/s (time 0) to 0.11 (time 12-13 hours), to 0.13 (time 24-36 hours) and to (time 48-61 hours) with no overall significance. A highly significant correlation was found between Crs and a/A ratio (r = 0.698, P less than 0.001). We conclude that Exosurf does not induce immediate changes in oxygenation as does the instillation of (modified) natural surfactant preparations. However, after 12 and 24 hours of treatment oxygenation and Crs improve significantly.(ABSTRACT TRUNCATED AT 250 WORDS)
Optical pen-size reflectometer for monitoring of early dental erosion in native and polished enamels
Resumo:
Application of the specular reflection intensity was previously reported for the quantification of early dental erosion. Further development of the technique and assembly of the miniaturized pen-size instrument are described. The optical system was adjusted to fit into a handy device which could potentially access different positions in the oral cavity. The assembled instrument could successfully detect early erosion progression in both polished (n=70) and native (n=20) human enamels. Different severities of enamel erosion were induced by varying incubation time of polished enamel in 1% citric acid (pH=3.60, 0.5 to 10 min), while the native incisors were treated in the commercial orange juice (Tropicana Pure Premium®, pH=3.85, 10 to 60 min). The instrument provided a good differentiation between various severities of the erosion in vitro. The size of the measurement spot affected the erosion monitoring in native enamel (human incisors). The erosion measurement in the 0.7-mm (diameter) cervical spots showed systematically lower reflection intensities compared with the analysis of central and incisal small spots. The application of larger spot areas (2.3 mm) for the erosion monitoring revealed no effect (p>0.05) of the spot position on the reflection signal. High variation of the teeth susceptibility toward in vitro erosion was detected in native enamel.
Resumo:
Foot-and-mouth disease (FMD) is highly contagious and one of the most economically devastating diseases of cloven-hoofed animals. Scientific-based preparedness about how to best control the disease in a previously FMD-free country is therefore essential for veterinary services. The present study used a spatial, stochastic epidemic simulation model to compare the effectiveness of emergency vaccination with conventional (non-vaccination) control measures in Switzerland, a low-livestock density country. Model results revealed that emergency vaccination with a radius of 3 km or 10 km around infected premises (IP) did not significantly reduce either the cumulative herd incidence or epidemic duration if started in a small epidemic situation where the number of IPs is still low. However, in a situation where the epidemic has become extensive, both the cumulative herd incidence and epidemic duration are reduced significantly if vaccination were implemented with a radius of 10 km around IPs. The effect of different levels of conventional strategy measures was also explored for the non-vaccination strategy. It was found that a lower compliance level of farmers for movement restrictions and delayed culling of IPs significantly increased both the cumulative IP incidence and epidemic duration. Contingency management should therefore focus mainly on improving conventional strategies, by increasing disease awareness and communication with stakeholders and preparedness of culling teams in countries with a livestock structure similar to Switzerland; however, emergency vaccination should be considered if there are reasons to believe that the epidemic may become extensive, such as when disease detection has been delayed and many IPs are discovered at the beginning of the epidemic.
Resumo:
This article addresses ethical consumer behavior and uses the purchase of Fair Trade (FT) coffee to gain insights into determinants of ‘moral behavior’ in the marketplace. Our primary concern is to clarify which theoretical concepts and determinants are more useful than others in explaining FT consumption. We compare the explanatory power of consumer budget restrictions, consumer identity, social and personal norms, social status, justice beliefs, and trust. Our second aim is methodological; we contrast data on self-reported consumption of FT coffee with experimental data on hypothetical choices of different coffee products. To gain insights into the robustness of our measurement and findings, we test our propositions using two samples of undergraduate students from Germany and the United States. Our data show that consumer identity and personal norms are the major determinants of FT consumption in both samples, the results from survey-based data and from our experimental data are similar in this regard. Further, we demonstrate that studies based on a limited number of determinants might overestimate effects; the effect of justice beliefs for instance vanishes if other determinants are taken into account.
Resumo:
Trauma related haemorrhagic anaemia is rarely diagnosed by physical examination alone but typically includes measurement of blood haemoglobin, one of the most frequently ordered laboratory tests. Recently, noninvasive technologies have been developed that allow haemoglobin to be measured immediately without the need for intravenous access or having to take venous, arterial, or capillary blood. Moreover, with these technologies haemoglobin can be continuously measured in patients with active bleeding, to guide the start and stop of blood transfusions and to detect occult bleeding. Recent studies on the accuracy of the devices showed promising results in terms of accuracy of hemoglobin measurement compared to laboratory determination. The present review gives an overview on the technology itself and reviews the current literature on the subject.
Resumo:
In situ diffusion experiments are performed in geological formations at underground research laboratories to overcome the limitations of laboratory diffusion experiments and investigate scale effects. Tracer concentrations are monitored at the injection interval during the experiment (dilution data) and measured from host rock samples around the injection interval at the end of the experiment (overcoring data). Diffusion and sorption parameters are derived from the inverse numerical modeling of the measured tracer data. The identifiability and the uncertainties of tritium and Na-22(+) diffusion and sorption parameters are studied here by synthetic experiments having the same characteristics as the in situ diffusion and retention (DR) experiment performed on Opalinus Clay. Contrary to previous identifiability analyses of in situ diffusion experiments, which used either dilution or overcoring data at approximate locations, our analysis of the parameter identifiability relies simultaneously on dilution and overcoring data, accounts for the actual position of the overcoring samples in the claystone, uses realistic values of the standard deviation of the measurement errors, relies on model identification criteria to select the most appropriate hypothesis about the existence of a borehole disturbed zone and addresses the effect of errors in the location of the sampling profiles. The simultaneous use of dilution and overcoring data provides accurate parameter estimates in the presence of measurement errors, allows the identification of the right hypothesis about the borehole disturbed zone and diminishes other model uncertainties such as those caused by errors in the volume of the circulation system and the effective diffusion coefficient of the filter. The proper interpretation of the experiment requires the right hypothesis about the borehole disturbed zone. A wrong assumption leads to large estimation errors. The use of model identification criteria helps in the selection of the best model. Small errors in the depth of the overcoring samples lead to large parameter estimation errors. Therefore, attention should be paid to minimize the errors in positioning the depth of the samples. The results of the identifiability analysis do not depend on the particular realization of random numbers. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In der vorliegenden Arbeit werden Entwicklung und Validierung eines Fragebogens zur umfassenden Erfassung der Achtsamkeit, des Comprehensive Inventory of Mindfulness Experiences (CHIME), beschrieben. An einer Allgemeinbevölkerungs-Stichprobe (N = 298) und einer Stichprobe von TeilnehmerInnen an MBSR-Kursen (N = 161) wurde die Faktorenstruktur des CHIME ermittelt und seine Reliabilität und Validität geprüft. Faktorenanalytische Verfahren ergaben eine achtfaktorielle Struktur. Die Struktur wurde in einer zusätzlichen konfirmatorischen Stichprobe (N = 202) überprüft. Der Fragebogen sowie seine Unterskalen weisen gute Reliabilitätswerte auf (interne Konsistenz und Retest-Reliabilität). Analysen zur Messinvarianz der einzelnen Items über Gruppen, die sich bezüglich Meditationserfahrung, Alter, Geschlecht und Symptombelastung unterschieden, zeigten keine systematischen Unterschiede im Verständnis der Items. Die Kennwerte zur Konstrukt-, Kriterium-, und inkrementellen Validität sowie zur Veränderungssensitivität waren alle mindestens zufriedenstellend. Mit dem CHIME steht somit ein Fragebogen mit guten psychometrischen Eigenschaften zur Selbsteinschätzung der Achtsamkeit zur Verfügung. Der CHIME basiert auf allen in den aktuellen Instrumenten enthaltenen Aspekten des Achtsamkeitskonstrukts.
Resumo:
This contribution focuses on the characteristics of the school context and their impact on immigrant students’ acculturation and adjustment at school. Research suggests that the ways immigrants acculturate is related to their well being (e.g. Phinney, et al., 2001; Ward & Rana-Deuba, 1999), although findings have been contradictory across methods and studies (e.g. Rogler, 1991; Escobar & Vega, 2001). Debates in acculturation research currently center on issues of acculturation measurement (e.g. Berry, 2009; Rudmin, 2009), as most research is conducted in the quantitative tradition. In addition, some have suggested (Birman, 2011) that research on acculturation in the tradition of cross-cultural psychology adopts an overly individualistic perspective, and lacks attention to the specific contexts of acculturation. Alternatively, the contextual approach proposes that the relationship between acculturation and adjustment is shaped by the surrounding context (Birman & Simon, 2013). For immigrant children, schools are the setting where the process of acculturation unfolds, and an important context in which to study their adjustment and well being (Birman, et al., 2007; Makarova & Herzog, 2011). Though rarely used in this tradition of acculturation research (Chirkov, 2009), qualitative methods are uniquely suited to gain insight to facilitate theory development, as well as appreciate the contextual nature of the acculturation process. Yet we are not aware of efforts to synthesize the empirical qualitative literature on this topic. Applying the methodology of meta-synthesis for qualitatieve research (Walsh & Downe, 2005) our contribution attempts to integrate results from qualitative studies on impact of acculturation on immigrant students’ psychological adjustment in the school context. For this purpose 84 articles which matched the inclusion criteria were selected. Overall, the results of our study show that within the school context a number of structural as well as process characteristics can be identified as crucial for immigrant youth psychological adjustment. Moreover, our findings indicate that immigrant youths’ psychological adjustment is related to other individual outcomes of acculturation in the school context such as behavioral adjustment, peer-relationships, academic achievement and identity development of immigrant youth.
Resumo:
Introduction: Measuring trait mindfulness and change in mindfulness may be a crucial prerequisite for the evaluation and further development of mindfulness based interventions for the treatment of mental disorders. This endeavour is nontrivial as current measures cover varying aspects and mindfulness and may have problems regarding validity. This presentation describes the development and validation of a questionnaire for the comprehensive assessment of mindfulness: the Comprehensive Inventory of Mindfulness Experiences (CHIME). Method: The factor structure, reliability, and validity of the CHIME were established in a community sample (N = 298) and a sample of MBSR group participants (N = 161). Results: Factor-analytical procedures supported an eight-factor structure. The structure was tested in a further confirmatory sample (N = 202). The questionnaire and its subscales exhibited good reliability (internal consistency and retest-reliability). Analysis of the measurement invariance of the single items over groups differing in age, gender, meditation experience, and symptom load pointed to the absence of systematic differences in the items' semantic understanding. Parameters reflecting construct validity, criterion validity, and incremental validity as well as change sensitivity were all at least satisfactory. Conclusions: The CHIME is a self-report measure with favorable psychometric properties based on all aspects of mindfulness that are included in current mindfulness scales. This scale may be helpful in the evaluation and further development of mindfulness based interventions.
Resumo:
We report the fabrication and field emission properties of high-density nano-emitter arrays with on-chip electron extraction gate electrodes and up to 106 metallic nanotips that have an apex curvature radius of a few nanometers and a the tip density exceeding 108 cm−2. The gate electrode was fabricated on top of the nano-emitter arrays using a self-aligned polymer mask method. By applying a hot-press step for the polymer planarization, gate–nanotip alignment precision below 10 nm was achieved. Fabricated devices exhibited stable field electron emission with a current density of 0.1 A cm−2, indicating that these are promising for applications that require a miniature high-brightness electron source.