30 resultados para bench-kokoluokka


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The variant Creutzfeldt-Jakob disease incidence peaked a decade ago and has since declined. Based on epidemiologic evidence, the causative agent, pathogenic prion, has not constituted a tangible contamination threat to large-scale manufacturing of human plasma-derived proteins. Nonetheless, manufacturers have studied the prion removal capabilities of various manufacturing steps to better understand product safety. Collectively analyzing the results could reveal experimental reproducibility and detect trends and mechanisms driving prion removal. STUDY DESIGN AND METHODS Plasma Protein Therapeutics Association member companies collected more than 200 prion removal studies on plasma protein manufacturing steps, including precipitation, adsorption, chromatography, and filtration, as well as combined steps. The studies used a range of model spiking agents and bench-scale process replicas. The results were grouped based on key manufacturing variables to identify factors impacting removal. The log reduction values of a group are presented for comparison. RESULTS Overall prion removal capacities evaluated by independent groups were in good agreement. The removal capacity evaluated using biochemical assays was consistent with prion infectivity removal measured by animal bioassays. Similar reduction values were observed for a given step using various spiking agents, except highly purified prion protein in some circumstances. Comparison between combined and single-step studies revealed complementary or overlapping removal mechanisms. Steps with high removal capacities represent the conditions where the physiochemical differences between prions and therapeutic proteins are most significant. CONCLUSION The results support the intrinsic ability of certain plasma protein manufacturing steps to remove prions in case of an unlikely contamination, providing a safeguard to products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BEAMnrc, a code for simulating medical linear accelerators based on EGSnrc, has been bench-marked and used extensively in the scientific literature and is therefore often considered to be the gold standard for Monte Carlo simulations for radiotherapy applications. However, its long computation times make it too slow for the clinical routine and often even for research purposes without a large investment in computing resources. VMC++ is a much faster code thanks to the intensive use of variance reduction techniques and a much faster implementation of the condensed history technique for charged particle transport. A research version of this code is also capable of simulating the full head of linear accelerators operated in photon mode (excluding multileaf collimators, hard and dynamic wedges). In this work, a validation of the full head simulation at 6 and 18 MV is performed, simulating with VMC++ and BEAMnrc the addition of one head component at a time and comparing the resulting phase space files. For the comparison, photon and electron fluence, photon energy fluence, mean energy, and photon spectra are considered. The largest absolute differences are found in the energy fluences. For all the simulations of the different head components, a very good agreement (differences in energy fluences between VMC++ and BEAMnrc <1%) is obtained. Only a particular case at 6 MV shows a somewhat larger energy fluence difference of 1.4%. Dosimetrically, these phase space differences imply an agreement between both codes at the <1% level, making VMC++ head module suitable for full head simulations with considerable gain in efficiency and without loss of accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proteomics is fulfilling its potential and beginning to impact the diagnosis and therapy of cardiovascular disease. As de novo proteomics analysis gets more streamlined, and robust high-throughput methods are developed, more and more attention is being directed toward the field of cardiovascular serum and plasma biomarker discovery. To take cardiovascular proteomics from bench to bedside, great care must be taken to achieve reproducible results. Despite technical advances, however, the absolute number of clinical biomarkers thus far discovered by a proteomics approach is small. Although several factors contribute to this lack, one step is to build "translation teams" involving a close collaboration between researchers and clinicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to overcome the limitations of the linear-quadratic model and include synergistic effects of heat and radiation, a novel radiobiological model is proposed. The model is based on a chain of cell populations which are characterized by the number of radiation induced damages (hits). Cells can shift downward along the chain by collecting hits and upward by a repair process. The repair process is governed by a repair probability which depends upon state variables used for a simplistic description of the impact of heat and radiation upon repair proteins. Based on the parameters used, populations up to 4-5 hits are relevant for the calculation of the survival. The model describes intuitively the mathematical behaviour of apoptotic and nonapoptotic cell death. Linear-quadratic-linear behaviour of the logarithmic cell survival, fractionation, and (with one exception) the dose rate dependencies are described correctly. The model covers the time gap dependence of the synergistic cell killing due to combined application of heat and radiation, but further validation of the proposed approach based on experimental data is needed. However, the model offers a work bench for testing different biological concepts of damage induction, repair, and statistical approaches for calculating the variables of state.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79 as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reliable detection of JAK2-V617F is critical for accurate diagnosis of myeloproliferative neoplasms (MPNs); in addition, sensitive mutation-specific assays can be applied to monitor disease response. However, there has been no consistent approach to JAK2-V617F detection, with assays varying markedly in performance, affecting clinical utility. Therefore, we established a network of 12 laboratories from seven countries to systematically evaluate nine different DNA-based quantitative PCR (qPCR) assays, including those in widespread clinical use. Seven quality control rounds involving over 21,500 qPCR reactions were undertaken using centrally distributed cell line dilutions and plasmid controls. The two best-performing assays were tested on normal blood samples (n=100) to evaluate assay specificity, followed by analysis of serial samples from 28 patients transplanted for JAK2-V617F-positive disease. The most sensitive assay, which performed consistently across a range of qPCR platforms, predicted outcome following transplant, with the mutant allele detected a median of 22 weeks (range 6-85 weeks) before relapse. Four of seven patients achieved molecular remission following donor lymphocyte infusion, indicative of a graft vs MPN effect. This study has established a robust, reliable assay for sensitive JAK2-V617F detection, suitable for assessing response in clinical trials, predicting outcome and guiding management of patients undergoing allogeneic transplant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four seasons of excavations at Horvat Kur in the Galilee (250570/754485) have exposed the remains of a broadhouse synagogue from the Byzantine period. The building was entered through a portico on the west or a doorway on the south. The fill beneath the portico included the discarded remains of a once colored mosaic as well as more than 1000 coins. A low bench of basalt stones (some of which were plastered) runs along the interior walls, interrupted only by a stone bemah in the center of the southern wall. The synagogue is thus oriented toward Jerusalem. Near the bemah, an ornamented limestone seat was found in situ atop the bench. The building underwent several changes and repairs in the course of its lifespan. On either side of the bemah, north-south rows of columns rested on stylobate. A basalt stone table was found in re-use in the eastern stylobate. Nicknamed “the Horvat Kur stone,” this monolith features geometric figures on three sides and figurative representations on one side. Its original function is as yet subject of research. A narrow test-trench into the sediment of a cistern located outside the northern wall of the synagogue has produced nearly thirty intact vessels of the early Byzantine period, mostly cooking pots and water jars. In addition a dense sequence of pollen samples has been taken. Preliminary interpretation of these finds indicates that the Horvat Kur synagogue illustrates Byzantine synagogue construction, decoration, and use in the setting of a Galilean village of modest economic circumstances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPORTANCE Little is known about whether sex differences in acute coronary syndrome (ACS) presentation exist in young patients and what factors determine absence of chest pain in ACS presentation. OBJECTIVES To evaluate sex differences in ACS presentation and to estimate associations between sex, sociodemographic, gender identity, psychosocial and clinical factors, markers of coronary disease severity, and absence of chest pain in young patients with ACS. DESIGN, SETTING, PARTICIPANTS We conducted a prospective cohort study of 1015 patients (30% women) 55 years or younger, hospitalized for ACS and enrolled in the GENESIS PRAXY (Gender and Sex Determinants of Cardiovascular Disease: From Bench to Beyond Premature Acute Coronary Syndrome) study (January 2009-September 2012). MAIN OUTCOMES AND MEASURES The McSweeney Acute and Prodromal Myocardial Infarction Symptom Survey was administered during hospitalization. RESULTS The median age for both sexes was 49 years. Women were more likely to have non-ST-segment elevation myocardial infarction (37.5 vs 30.7; P = .03) and present without chest pain compared with men (19.0% vs 13.7%; P = .03). Patients without chest pain reported fewer symptoms overall and no discernable pattern of non-chest pain symptoms was found. In the multivariate model, being a woman (odds ratio [OR], 1.95 [95% CI, 1.23-3.11]; P = .005) and tachycardia (OR, 2.07 [95% CI, 1.20-3.56]; P = .009) were independently associated with ACS presentation without chest pain. Patients without chest pain did not differ significantly from those with chest pain in terms of ACS type, troponin level elevation, or coronary stenosis. CONCLUSIONS AND RELEVANCE Chest pain was the most common ACS symptom in both sexes. Although women were more likely to present without chest pain than men, absence of chest pain was not associated with markers of coronary disease severity. Strategies that explicitly incorporate assessment of common non-chest pain symptoms need to be evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since November 1994, the GROund-based Millimeter-wave Ozone Spectrometer (GROMOS) measures stratospheric and lower mesospheric ozone in Bern, Switzerland (47.95° N, 7.44° E). GROMOS is part of the Network for the Detection of Atmospheric Composition Change (NDACC). In July 2009, a Fast-Fourier-Transform spectrometer (FFTS) has been added as backend to GROMOS. The new FFTS and the original filter bench (FB) measured parallel for over two years. In October 2011, the FB has been turned off and the FFTS is now used to continue the ozone time series. For a consolidated ozone time series in the frame of NDACC, the quality of the stratospheric ozone profiles obtained with the FFTS has to be assessed. The FFTS results from July 2009 to December 2011 are compared to ozone profiles retrieved by the FB. FFTS and FB of the GROMOS microwave radiometer agree within 5% above 20 hPa. A later harmonization of both time series will be realized by taking the FFTS as benchmark for the FB. Ozone profiles from the FFTS are also compared to coinciding lidar measurements from the Observatoire Haute Provence (OHP), France. For the time period studied a maximum mean difference (lidar – GROMOS FFTS) of +3.8% at 3.1 hPa and a minimum mean difference of +1.4% at 8 hPa is found. Further, intercomparisons with ozone profiles from other independent instruments are performed: satellite measurements include MIPAS onboard ENVISAT, SABER onboard TIMED, MLS onboard EOS Aura and ACE-FTS onboard SCISAT-1. Additionally, ozonesondes launched from Payerne, Switzerland, are used in the lower stratosphere. Mean relative differences of GROMOS FFTS and these independent instruments are less than 10% between 50 and 0.1 hPa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The association between depression and cardiovascular disease severity in younger patients has not been assessed, and sex differences are unknown. We assessed whether major depression and depressive symptoms were associated with worse cardiovascular disease severity in patients with premature acute coronary syndrome, and we assessed sex differences in these relationships. METHODS We enrolled 1023 patients (aged ≤ 55 years) hospitalized with acute coronary syndrome from 26 centers in Canada, the United States, and Switzerland, through the GENdEr and Sex determInantS of cardiovascular disease: From bench to beyond-Premature Acute Coronary Syndrome study. Left ventricular ejection fraction, Killip class, cardiac troponin I, and Global Registry of Acute Coronary Events score data were collected through chart review. RESULTS The sample comprised 248 patients with major depression and 302 women. In univariate analyses, major depression was associated with a lower likelihood of having an abnormal left ventricular ejection fraction (odds ratio, 0.70; 95% confidence interval, 0.51-0.97; P = .03) and lower troponin I levels (estimate, -4.04; 95% confidence interval, -8.01 to -0.06; P = .05). After adjustment for sociodemographic and clinical characteristics, neither major depression nor depressive symptoms were associated with disease severity indices, and there were no sex differences. CONCLUSION The increased risk of adverse events in depressed patients with premature acute coronary syndrome is not explained by disease severity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10(6), 1.08±0.11 × 10(5), 1.03±0.10 × 10(4), 1.02±0.09 × 10(3), 1.04±0.10 × 10(2) and 10.0±1.5 copies/μl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. Permittivity measurements on porous samples of volcanic origin have been performed in the 0.05-190 GHz range under laboratory conditions in support of the Rosetta mission to comet 67P/Churyumov-Gerasimenko, specifically with the MIRO radiometric experiment and CONSERT radar experiment. Methods. The samples were split into several subsamples with different size ranges covering a few mu m to 500 mu m. Bulk densities of the subsamples were estimated to be in the 800 to 1500 kg/m(3) range. The porosities were in the range of 48% to 65%. From 50 MHz to 6 GHz and at 190 GHz, permittivity has been determined with a coaxial cell and with a quasi-optical bench, respectively. Results. Without taking into account the volume-scattering effect at 190 GHz, the real part of the permittivity, normalized by the bulk density, is in the range of 2.1 to 2.6. The results suggest that the real part of the permittivity of an ice-free dust mantle covering the nucleus is in the 1.5-2.2 range at 190 GHz. From these values, a lower limit for the absorption length for the millimeter receiver of MIRO has been estimated to be between 0.6 and 2 cm, in agreement with results obtained from MIRO in September 2014. At frequencies of interest for CONSERT experiment, the real part of the permittivity of a suspected ice-free dust mantle should be below 2.2. It may be in the range of 1.2 to 1.7 for the nucleus, in agreement with first CONSERT results, taking into account a mean temperature of 110 K and different values for the dust-to-ice volumetric ratio. Estimations of contributions of the different parameters to the permittivity variation may indicate that the porosity is the main parameter.