19 resultados para Submicroscopic imbalances


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eringer cows are often slaughtered due to fertility problems which result from inflammatory and degenerative changes of the uterus or hormonal imbalances. Twenty-one genital tracts from Eringer cows suffering from fertility problems were collected in the abattoir. The purpose of the study was the macroscopic evaluation of the ovaries and the uterus followed by a histological and microbiological analysis of the uterus. Data from inseminations and calvings were provided by the Eringer breeding association and through the internet portal www.agate.ch. Median age of the cows was 6.9 years, number of calves per cow was 2.5 and median period between last calving and slaughter was 1.5 years. In 13 from 21 of the urogenital tracts examined, macroscopic abnormalities of the ovaries and/or histologic or microbiologic findings in the uterus could explain fertility-associated slaughter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Patients with electrolyte imbalances or disorders have a high risk of mortality. It is unknown if this finding from sodium or potassium disorders extends to alterations of magnesium levels. METHODS AND PATIENTS In this cross-sectional analysis, all emergency room patients between 2010 and 2011 at the Inselspital Bern, Switzerland, were included. A multivariable logistic regression model was performed to assess the association between magnesium levels and in-hospital mortality up to 28days. RESULTS A total of 22,239 subjects were screened for the study. A total of 5339 patients had plasma magnesium concentrations measured at hospital admission and were included into the analysis. A total of 6.3% of the 352 patients with hypomagnesemia and 36.9% of the 151 patients with hypermagnesemia died. In a multivariate Cox regression model hypermagnesemia (HR 11.6, p<0.001) was a strong independent risk factor for mortality. In these patients diuretic therapy revealed to be protective (HR 0.5, p=0.007). Hypomagnesemia was not associated with mortality (p>0.05). Age was an independent risk factor for mortality (both p<0.001). CONCLUSION The study does demonstrate a possible association between hypermagnesemia measured upon admission in the emergency department, and early in-hospital mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Phosphate imbalances or disorders have a high risk of morbidity and mortality in patients with chronic kidney disease. It is unknown if this finding extends to mortality in patients presenting at an emergency room with or without normal kidney function. METHODS AND PATIENTS This cross sectional analysis included all emergency room patients between 2010 and 2011 at the Inselspital Bern, Switzerland. A multivariable cox regression model was applied to assess the association between phosphate levels and in-hospital mortality up to 28 days. RESULTS 22,239 subjects were screened for the study. Plasma phosphate concentrations were measured in 2,390 patients on hospital admission and were included in the analysis. 3.5% of the 480 patients with hypophosphatemia and 10.7% of the 215 patients with hyperphosphatemia died. In univariate analysis, phosphate levels were associated with mortality, age, diuretic therapy and kidney function (all p<0.001). In a multivariate Cox regression model, hyperphosphatemia (OR 3.29, p<0.001) was a strong independent risk factor for mortality. Hypophosphatemia was not associated with mortality (p>0.05). CONCLUSION Hyperphosphatemia is associated with 28-day in-hospital mortality in an unselected cohort of patients presenting in an emergency room.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.