52 resultados para Reproducibility of serological tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reproducibility of metabolite content determined by MR spectroscopy (MRS) is usually at best a few percent for the prominent singlets. When studying low-concentration metabolites, like phenylalanine (Phe), where tissue content can be <100 micromol/kg, better reproducibility is paramount-particularly in view of using MRS results for potential individual treatment advice. An optimized, targeted spectroscopy method was established at 1.5T and reproducibility was established in 21 patients with phenylketonuria (PKU) where three spectra were recorded in each of three independent sessions, two of which were in immediate succession to minimize physiologic variation. Intersession variation was found to be only 7 micromol/kg Phe for back-to-back repetition of sessions, in close agreement with the variation of 16 micromol/kg observed for single spectra within a session. Analysis of variance proved the individuality of the blood/brain Phe ratio-though this ratio seems to be influenced by physiologic factors that are not stable in time. The excellent reproducibility was achieved through optimization of various factors, including signal-to-noise ratio, repositioning, and prescan calibrations, but also by enforcing as much prior information as possible (e.g., lineshape and phase from reference scans, constant prior-knowledge-locked baseline). While the application of maximum general prior knowledge is a general method to reduce fluctuations, one should remember that it may introduce systematic errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To test the reproducibility of retinal thickness measurements in healthy volunteers of a new Frequency-domain optical coherence tomography (OCT) device (Spectralis OCT; Heidelberg Engineering, Heidelberg, Germany). DESIGN: Prospective, observational study. METHODS: Forty-one eyes of 41 healthy subjects were included into the study. Intraobserver reproducibility was tested with 20 x 15 degree raster scans consisting of 37 high-resolution line scans that were repeated three times by one examiner (M.N.M.). Mean retinal thickness was calculated for nine areas corresponding to the Early Treatment Diabetic Retinopathy Study (ETDRS) areas. Coefficients of variation (COV) were calculated. RESULTS: Retinal thickness measurements were highly reproducible for all ETDRS areas. Mean total retinal thickness was 342 +/- 15 microm. Mean foveal thickness was 286 +/- 17 microm. COVs ranged from 0.38% to 0.86%. Lowest COV was found for the temporal outer ETDRS area (area 7; COV, 0.38%). Highest COV was found for the temporal inner ETDRS area (area 3; COV, 0.86%). Mean difference between measurement 1 and 2, measurement 1 and 3, and measurement 2 and 3 for all ETDRS areas was 1.01 microm, 0.98 microm, and 0.99 microm, respectively. CONCLUSION: Spectralis OCT retinal thickness measurements in healthy volunteers showed excellent intraobserver reproducibility with virtually identical results between retinal thickness measurements performed by one operator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Although free eye testing is available in the UK from a nation-wide network of optometrists, there is evidence of unrecognised, tractable vision loss amongst older people. A recent review identified this unmet need as a priority for further investigation, highlighting the need to understand public perceptions of eye services and barriers to service access and utilisation. This paper aims to identify risk factors for (1) having poor vision and (2) not having had an eyesight check among community-dwelling older people without an established ophthalmological diagnosis. METHODS Secondary analysis of self-reported data from the ProAge trial. 1792 people without a known ophthalmological diagnosis were recruited from three group practices in London. RESULTS Almost two in ten people in this population of older individuals without known ophthalmological diagnoses had self-reported vision loss, and more than a third of them had not had an eye test in the previous twelve months. In this sample, those with limited education, depressed mood, need for help with instrumental and basic activities of daily living (IADLs and BADLs), and subjective memory complaints were at increased risk of fair or poor self-reported vision. Individuals with basic education only were at increased risk for not having had an eye test in the previous 12 months (OR 1.52, 95% CI 1.17-1.98 p=0.002), as were those with no, or only one chronic condition (OR 1.850, 95% CI 1.382-2.477, p<0.001). CONCLUSIONS Self-reported poor vision in older people without ophthalmological diagnoses is associated with other functional losses, with no or only one chronic condition, and with depression. This pattern of disorders may be the basis for case finding in general practice. Low educational attainment is an independent determinant of not having had eye tests, as well as a factor associated with undiagnosed vision loss. There are other factors, not identified in this study, which determine uptake of eye testing in those with self-reported vision loss. Further exploration is needed to identify these factors and lead towards effective case finding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Reproducibility of basic research investigations in homeopathy is challenging. This study investigated if formerly observed effects of homeopathically potentised gibberellic acid (GA3) on growth of duckweed (Lemna gibba L.) were reproducible. METHODS: Duckweed was grown in potencies (14x-30x) of GA3 and one time succussed and unsuccussed water controls. Outcome parameter area-related growth rate was determined by a computerised image analysis system. Three series including five independent blinded and randomised potency experiments (PE) each were carried out. System stability was controlled by three series of five systematic negative control (SNC) experiments. Gibbosity (a specific growth state of L. gibba) was investigated as possibly essential factor for reactivity of L. gibba towards potentised GA3 in one series of potency and SNC experiments, respectively. RESULTS: Only in the third series with gibbous L. gibba L. we observed a significant effect (p = 0.009, F-test) of the homeopathic treatment. However, growth rate increased in contrast to the former study, and most biologically active potency levels differed. Variability in PE was lower than in SNC experiments. The stability of the experimental system was verified by the SNC experiments. CONCLUSIONS: Gibbosity seems to be a necessary condition for reactivity of L. gibba to potentised GA3. Further still unknown conditions seem to govern effect direction and the pattern of active and inactive potency levels. When designing new reproducibility studies, the physiological state of the test organism must be considered. Variability might be an interesting parameter to investigate effects of homeopathic remedies in basic research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Assessment of endothelial function of the microvasculature by peripheral arterial tonometry (EndoPAT(®)) has gained increasing popularity in patients with cardiovascular risk factors. Only limited knowledge about its reproducibility in patients with coronary artery disease (CAD) is available. We therefore aimed to quantify reproducibility of EndoPAT(®) parameters in patients with stable CAD. DESIGN EndoPAT(®) measurements were performed repeatedly in 78 male patients (age 66 ± 8 years) with CAD on stable medication. We calculated overall mean, standard deviation (SD), coefficient of variation (CV) and intraclass correlation coefficient (ICC) of the following parameters: reactive hyperemic index (RHI), PAT ratio of the postocclusion period 90-150 s as used for calculation of the RHI (PAT ratio90-150 s) and 90-120 s (PAT ratio90-120 s) as used for the often employed Framingham RHI (F-RHI), as well as PAT ratio of the peak hyperemic response (PAT ratiopeak response). Additionally, least significant changes (LSC) for individual subjects and minimum sample sizes for parallel and cross-over design studies were calculated. RESULTS Mean RHI was 1·84 (SD 0·36). For RHI, PAT ratio90-150 s , PAT ratio90-120 s , and PAT ratiopeak response the CVs were 17·0%, 25·4%, 26·1%, and 25·0%, respectively. The ICCs were 0·45, 0·49, 0·48 and 0·51, respectively, and LSC for RHI was 47·2%. CONCLUSIONS CV of RHI in our population was moderate; however, we consider this precision insufficient to monitor changes in individual patients, as they would need to exceed 47% to show a significant change. Further, the poor ICCs reflect the difficulty of detecting treatment effects in homogenous populations, such as patients with stable CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Hepatitis B viruses (HBV) harboring mutations in the a-determinant of the Hepatitis B surface antigen (HBsAg) are associated with reduced reactivity of HBsAg assays. OBJECTIVES To evaluate the sensitivity and specificity of three HBsAg point-of-care tests for the detection of HBsAg of viruses harboring HBsAg mutations. STUDY DESIGN A selection of 50 clinical plasma samples containing HBV with HBsAg mutations was used to evaluate the performance of three HBsAg point-of-care tests (Vikia(®), bioMérieux, Marcy-L'Étoile, France. Alere Determine HBsAg™, Iverness Biomedical Innovations, Köln, Germany. Quick Profile™, LumiQuick Diagnostics, California, USA) and compared to the ARCHITECT HBsAg Qualitative(®) assay (Abbott Laboratories, Sligo, Ireland). RESULTS The sensitivity of the point-of-care tests ranged from 98% to 100%. The only false-negative result occurred using the Quick Profile™ assay with a virus harboring a D144A mutation. CONCLUSIONS The evaluated point-of-care tests revealed an excellent sensitivity in detecting HBV samples harboring HBsAg mutations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Several parameters of heart rate variability (HRV) have been shown to predict the risk of sudden cardiac death (SCD) in cardiac patients. There is consensus that risk prediction is increased when measuring HRV during specific provocations such as orthostatic challenge. For the first time, we provide data on reproducibility of such a test in patients with a history of acute coronary syndrome. METHODS: Sixty male patients (65+/-8years) with a history of acute coronary syndrome on stable medication were included. HRV was measured in supine (5min) and standing (5min) position on 2 occasions separated by two weeks. For risk assessment relevant time-domain [standard deviation of all R-R intervals (SDNN) and root mean squared standard differences between adjacent R-R intervals (RMSSD)], frequency domain [low-frequency power (LF), high-frequency power (HF) and LF/HF power ratio] and short-term fractal scaling component (DF1) were computed. Absolute reproducibility was assessed with the standard errors of the mean (SEM) and 95% limits of random variation, and relative reproducibility by the intraclass correlation coefficient (ICC). RESULTS: We found comparable SEMs and ICCs in supine position and after an orthostatic challenge test. All ICCs were good to excellent (ICCs between 0.636 and 0.869). CONCLUSIONS: Reproducibility of HRV parameters during orthostatic challenge is good and comparable with supine position.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

mgof computes goodness-of-fit tests for the distribution of a discrete (categorical, multinomial) variable. The default is to perform classical large sample chi-squared approximation tests based on Pearson's X2 statistic and the log likelihood ratio (G2) statistic or a statistic from the Cressie-Read family. Alternatively, mgof computes exact tests using Monte Carlo methods or exhaustive enumeration. A Kolmogorov-Smirnov test for discrete data is also provided. The moremata package, also available from SSC, is required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alveolar echinococcosis (AE), caused by larva stage of Echinococcus multilocularis, is one of the lethal parasitic diseases of man and a major public health problem in many countries in the northern hemisphere. When the living conditions and habits in Turkey were considered in terms of relation with the life cycle of the parasite, it was suggested that AE has been much more common than reported mainly from the Eastern Anatolia region of Turkey. Since in vitro serologic diagnosis tests with high specificity for AE have not been used in our country, most of the cases with liver lesions were misdiagnosed by radiological investigations as malignancies. The aim of this study was to evaluate the diagnostic value of the in-house ELISA methods developed by using three different antigens (EgHF, Em2, EmII/3-10) in the serological diagnosis of AE. The study samples included a total of 100 sera provided by Bern University Parasitology Institute where samples were obtained from patients with helminthiasis and all were confirmed by clinical, parasitological and/or histopathological means. Ten samples from each of the cases infected by E.multilocularis, E.granulosus, Taenia solium, Wuchereria bancrofti, Strongyloides stercolaris, Ascaris lumbricoides, Toxocara canis, Trichinella spiralis, Fasciola hepatica and Schistosoma haematobium were studied. In the study, EgHF (E.granulosus hydatid fluid) antigens were prepared in our laboratory from the liver cyst fluids of sheeps with cystic echinococcosis, however Em2 (E.multilocularis metacestode-purified laminated layer) and EmII/3-10 (E.multilocularis recombinant protoscolex tegument) antigens were provided by Bern University Parasitology Institute. Flat bottom ELISA plates were covered with EgHF, Em2 and EmII/3-10 antigens in the concentrations of 2.5 µg, 1 µg and 0.18 µg per well, respectively, and all sera were tested by EgHF-ELISA, Em2-ELISA and EmII/3-10-ELISA methods. For each tests, the samples which were reactive above the cut-off value (mean OD of negative controls+2 SD) were accepted as positive. The sensitivity of the ELISA tests performed with EgHF, Em2 and Em2II/3-10 antigens were estimated as 100%, 90% and 90%, respectively, whereas the specificity were 63%, 91% and 91%, respectively. When Em2-ELISA and EmII/3-10-ELISA tests were evaluated together, the specificity increased to 96%. Our data indicated that the highest sensitivity (100% with EgHF-ELISA) and specificity (96% with Em2-ELISA + EmII/3-10-ELISA) for the serodiagnosis of AE can be achieved by the combined use of the ELISA tests with three different antigens. It was concluded that the early and accurate diagnosis of AE in our country which is endemic for that disease, could be supported by the use of highly specific serological tests such as Em2-ELISA ve EmII/3-10-ELISA contributing radiological data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Outbreak of bluetongue virus serotype-8 (BTV-8) infection in domestic ruminants in Northern Europe. OBJECTIVE: To investigate the South American camelids' (SAC) susceptibility to BTV-8 infection, their role in the epidemiology of the disease, and the use of currently available serological screening tests in SAC in an endemic region. ANIMALS: Three hundred and fifty-four unvaccinated and 27 vaccinated SAC (170 llamas, 201 alpacas), ranging in age from 1 month to 17 years between June and August 2008. The SAC originated from 44 herds throughout the country, representing 10% of the Swiss SAC population. METHODS: Prospective, observational study of a convenience sample of SAC. Serum samples were analyzed with 2 serological screening tests. When results diverged, a 3rd ELISA was carried out for confirmation (ID Screen Bluetongue Competition ELISA kit). RESULTS: All sera from the 354 unvaccinated animals were negative in the endemic region. Reliable seroconversion was observed after administration of 2 doses of vaccine. CONCLUSIONS AND CLINICAL IMPORTANCE: This study suggests a low susceptibility of SAC to BTV-8 despite the presence of the virus in the cattle and small ruminant population, indicating that SAC do not play a major role in the epidemiology of BTV-8. Furthermore, these results indicate that commercially available serological tests for BTV-8 can be used in SAC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. METHODS CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. RESULTS For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). CONCLUSIONS All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this in vitro study was to assess the influence of varying examiner's clinical experience on the reproducibility and accuracy of radiographic examination for occlusal caries detection. Standardized bitewing radiographs were obtained from 166 permanent molars. Radiographic examination was performed by final-year dental students from two universities (A, n = 5; B, n = 5) and by dentists with 5 to 7 years of experience who work in two different countries (C, n = 5; D, n = 5). All examinations were repeated after 1-week interval. The teeth were histologically prepared and assessed for caries extension. For intraexaminer reproducibility, the unweighted kappa values were: A (0.11-0.40), B (0.12-0.33), C (0.47-0.58), and D (0.42-0.71). Interexaminer reproducibility statistics were computed based on means ± SD of unweighted kappa values: A (0.07 ± 0.05), B (0.12 ± 0.09), C (0.24 ± 0.08), and D (0.33 ± 0.10). Sensitivity, specificity, and accuracy were calculated at D(1) and D(3) thresholds and compared by performing McNemar test (p = 0.05). D(1) sensitivity ranged between 0.29 and 0.75 and specificity between 0.24 and 0.85. D(3) specificity was moderate to high (between 0.62 and 0.95) for all groups, with statistically significant difference between the dentists groups (C and D). Sensitivity was low to moderate (between 0.21 and 0.57) with statistically significant difference for groups B and D. Accuracy was similar for all groups (0.55). Spearman's correlations were: A (0.12), B (0.24), C (0.30), and D (0.38). In conclusion, the reproducibility of radiographic examination was influenced by the examiner's clinical experience, training, and dental education as well as the accuracy in detecting occlusal caries.