40 resultados para Quark Masses and SM Parameters


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to assess bone mineral density (BMD) and parameters for bone metabolism in patients with end-stage heart disease awaiting heart transplantation to determine whether these patients are at increased risk of bone disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Rubber dam is recommended for isolating the working field during adhesive dentistry procedures; however, dentists often omit rubber dam, particularly in paediatric dentistry, supposing that it would stress the patient. AIM The aim of this study was to evaluate stress parameters during a standardized dental treatment procedure performed with or without rubber dam. The treatment time was measured as a secondary outcome variable. DESIGN This study was designed as a randomized, controlled, clinical study with 72 patients (6-16 years; mean age, 11.1). During standardized fissure sealing procedures, objective parameters of stress (e.g., skin resistance, breath rate) were recorded. The operator's stress level was measured by pulse rate. Subjective pain (patients) and stress perception (operator) were evaluated by an interview. RESULTS The breath rate was significantly (P<0.05) lower and the skin resistance level was significantly higher during treatment with rubber dam compared to the control group. Subjective pain perception was significantly lower for the test group. The treatment time needed for the fissure sealing procedure was 12.4% less in the test group. CONCLUSION Isolation with rubber dam caused less stress in children and adolescents compared to relative isolation with cotton rolls if applied by an experienced dentist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In situ diffusion experiments are performed in geological formations at underground research laboratories to overcome the limitations of laboratory diffusion experiments and investigate scale effects. Tracer concentrations are monitored at the injection interval during the experiment (dilution data) and measured from host rock samples around the injection interval at the end of the experiment (overcoring data). Diffusion and sorption parameters are derived from the inverse numerical modeling of the measured tracer data. The identifiability and the uncertainties of tritium and Na-22(+) diffusion and sorption parameters are studied here by synthetic experiments having the same characteristics as the in situ diffusion and retention (DR) experiment performed on Opalinus Clay. Contrary to previous identifiability analyses of in situ diffusion experiments, which used either dilution or overcoring data at approximate locations, our analysis of the parameter identifiability relies simultaneously on dilution and overcoring data, accounts for the actual position of the overcoring samples in the claystone, uses realistic values of the standard deviation of the measurement errors, relies on model identification criteria to select the most appropriate hypothesis about the existence of a borehole disturbed zone and addresses the effect of errors in the location of the sampling profiles. The simultaneous use of dilution and overcoring data provides accurate parameter estimates in the presence of measurement errors, allows the identification of the right hypothesis about the borehole disturbed zone and diminishes other model uncertainties such as those caused by errors in the volume of the circulation system and the effective diffusion coefficient of the filter. The proper interpretation of the experiment requires the right hypothesis about the borehole disturbed zone. A wrong assumption leads to large estimation errors. The use of model identification criteria helps in the selection of the best model. Small errors in the depth of the overcoring samples lead to large parameter estimation errors. Therefore, attention should be paid to minimize the errors in positioning the depth of the samples. The results of the identifiability analysis do not depend on the particular realization of random numbers. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal screening masses related to the conserved vector current are determined for the case that the current carries a non-zero Matsubara frequency, both in a weak-coupling approach and through lattice QCD. We point out that such screening masses are sensitive to the same infrared physics as light-cone real-time rates. In particular, on the perturbative side, the inhomogeneous Schrödinger equation determining screening correlators is shown to have the same general form as the equation implementing LPM resummation for the soft-dilepton and photon production rates from a hot QCD plasma. The static potential appearing in the equation is identical to that whose soft part has been determined up to NLO and on the lattice in the context of jet quenching. Numerical results based on this potential suggest that screening masses overshoot the free results (multiples of 2πT) more strongly than at zero Matsubara frequency. Four-dimensional lattice simulations in two-flavour QCD at temperatures of 250 and 340 MeV confirm the non-static screening masses at the 10% level. Overall our results lend support to studies of jet quenching based on the same potential at T ≳ 250 MeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE A controlled clinical trial was conducted to evaluate the effects of oral prophylaxis on halitosis-associated, immunological and microbiological parameters. METHODS Thirty subjects were included in this controlled clinical trial (patients with generalized chronic periodontitis and controls without clinical attachment loss; each n = 15). Before oral prophylaxis and 14 days after (including tongue cleaning) volatile sulphur compounds (VSC), organoleptic scores and a tongue coating index were evaluated. The levels of IL-1β, IL-8, IL-10 and MMP-8 were measured in GCF, and also major periodontal pathogens were detected. Data were statistically analysed using anova and paired t-test. RESULTS Supragingival plaque and calculus removal with combined tongue cleaning was able to reduce significantly (P < 0.05) the VSC values in both groups (no significant differences between both groups). Two weeks after periodontal debridement, the VSC values were observed in the periodontitis group, but not in the control group, similar to the baseline values. The difference between the groups was statistically significant (P < 0.05). Only a repeated prophylaxis session in the periodontitis group was able to reduce VSC values significantly in comparison with baseline (P < 0.05). Organoleptic scores (10 and 30 cm) were significantly different (P < 0.05) between both groups before and after the treatment. Periodontal pathogens and host-derived markers were not significantly affected by a single prophylaxis session. CONCLUSIONS Oral prophylaxis may result in a significant decrease in VSC values. However, in periodontal diseases, a more complex treatment seems to be necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES In this phantom CT study, we investigated whether images reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) with reduced tube voltage and current have equivalent quality. We evaluated the effects of different acquisition and reconstruction parameter settings on image quality and radiation doses. Additionally, patient CT studies were evaluated to confirm our phantom results. METHODS Helical and axial 256 multi-slice computed tomography scans of the phantom (Catphan(®)) were performed with varying tube voltages (80-140kV) and currents (30-200mAs). 198 phantom data sets were reconstructed applying FBP and IR with increasing iterations, and soft and sharp kernels. Further, 25 chest and abdomen CT scans, performed with high and low exposure per patient, were reconstructed with IR and FBP. Two independent observers evaluated image quality and radiation doses of both phantom and patient scans. RESULTS In phantom scans, noise reduction was significantly improved using IR with increasing iterations, independent from tissue, scan-mode, tube-voltage, current, and kernel. IR did not affect high-contrast resolution. Low-contrast resolution was also not negatively affected, but improved in scans with doses <5mGy, although object detectability generally decreased with the lowering of exposure. At comparable image quality levels, CTDIvol was reduced by 26-50% using IR. In patients, applying IR vs. FBP resulted in good to excellent image quality, while tube voltage and current settings could be significantly decreased. CONCLUSIONS Our phantom experiments demonstrate that image quality levels of FBP reconstructions can also be achieved at lower tube voltages and tube currents when applying IR. Our findings could be confirmed in patients revealing the potential of IR to significantly reduce CT radiation doses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Collection of semen on the ground from the standing stallion represents an alternative method to dummy mount semen collection and is of increasing popularity for sport stallions, males suffering from health problems, or in studs without a dummy or suitable mare at disposal. Our aim was to collect and compare spermatological and physiological data associated with traditional and ground semen collection. Twelve of 23 Franches-Montagnes stallions were selected to carry out semen collection on a dummy and while standing in a crossed experimental protocol. Semen quantity and quality parameters, weight bearing on hindquarters, and behavioral and libido data were recorded. Ground versus dummy mount semen collection was accompanied by lower seminal volume (15.9 ± 14.6 vs. 22.0 ± 13.3 mL; P < 0.01) and lower total sperm count (4.913 ± 2.721 × 10(9) vs. 6.544 ± 2.856 × 10(9) sperm; P < 0.001). No significant differences were found concerning sperm motility and viability. Time to ejaculation was longer, and the number of attempts to ejaculation was higher (P = 0.053) in the standing position compared with the mount on the dummy. A higher (P < 0.01) amount of tail flagging was manifested by the stallions during ejaculation on the dummy compared to when standing. There was no difference in weight bearing on hindquarters when comparing dummy collection (51.2 ± 2.5%) and standing collection (48.9 ± 5.5%). Ground semen collection can be considered as a viable option for stallions that cannot mount a dummy or a mare. However, it requires training and may be not easily accepted by all stallions. Owners should be advised that ground semen collection is associated with significantly lower sperm numbers than with dummy mount semen collection.