40 resultados para Quality evaluation and certification
Resumo:
High self-esteem often predicts job-related outcomes, such as high job satisfaction or high status. Theoretically, high quality jobs (HQJs) should be important for self-esteem, as they enable people to use a variety of skills and attribute accomplishments to themselves, but research findings are mixed. We expected reciprocal relationships between self-esteem and HQJ. However, as work often is more important for the status of men, we expected HQJ to have a stronger influence on self-esteem for men as compared to women. Conversely, task-related achievements violate gender stereotypes for women, who may need high self-esteem to obtain HQJs. In a 4-year cross-lagged panel analysis with 325 young workers, self-esteem predicted HQJ; the lagged effect from HQJ on self-esteem was marginally significant. In line with the hypotheses, the multigroup model showed a significant path only from self-esteem to HQJ for women, and from HQJ to self-esteem for men. The reverse effect was not found for women, and only marginally significant for men. Overall, although there were some indications for reciprocal effects, our findings suggest that women need high self-esteem to obtain HQJs to a greater degree than men, and that men base their self-esteem on HQJs to a greater extent than women.
Resumo:
In accordance with Bengtson's model of intergenerational solidarity (e.g. Bengtson & Roberts, 1991), the interrelations between adult daughters' family values, their perception of the relationship quality with their parents, the support they reported to give to and to receive from their parents, and their perception of reciprocity in intergenerational support exchange were investigated for N = 265 middle-aged women in Germany. It was also asked whether the support given to parents and perceived reciprocity are related to daughters' felt burden as a result of their support. Cross-sectional, self-report data were examined with multiple and multinomial logistic regression analyses. The analyses revealed positive relations between family values, relationship quality, and support to parents. Perceived reciprocity was associated with the exchange of intergenerational support and imbalance in support had negative effects on the relationship quality. Felt burden was predicted by the extent of support and the perceived reciprocity. However, specific correlational patterns depending on the kind of support as well as differences in the importance of mother and father occurred. The findings are discussed against the background of the meaning of family obligations and reciprocity in a Western culture.
Resumo:
We present an image quality assessment and enhancement method for high-resolution Fourier-Domain OCT imaging like in sub-threshold retina therapy. A Maximum-Likelihood deconvolution algorithm as well as a histogram-based quality assessment method are evaluated.
Resumo:
Cephalometric analysis is an essential clinical and research tool in orthodontics for the orthodontic analysis and treatment planning. This paper presents the evaluation of the methods submitted to the Automatic Cephalometric X-Ray Landmark Detection Challenge, held at the IEEE International Symposium on Biomedical Imaging 2014 with an on-site competition. The challenge was set to explore and compare automatic landmark detection methods in application to cephalometric X-ray images. Methods were evaluated on a common database including cephalograms of 300 patients aged six to 60 years, collected from the Dental Department, Tri-Service General Hospital, Taiwan, and manually marked anatomical landmarks as the ground truth data, generated by two experienced medical doctors. Quantitative evaluation was performed to compare the results of a representative selection of current methods submitted to the challenge. Experimental results show that three methods are able to achieve detection rates greater than 80% using the 4 mm precision range, but only one method achieves a detection rate greater than 70% using the 2 mm precision range, which is the acceptable precision range in clinical practice. The study provides insights into the performance of different landmark detection approaches under real-world conditions and highlights achievements and limitations of current image analysis techniques.
Resumo:
Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.
Resumo:
The present document has been elaborated in the context of the ERA-ARD project “The Agricultural Research for Development (ARD) dimension of the European Research Area (ERA) “. It is based on work done within Task 3.2 to identify a set of common or compatible methodologies for ARD planning, monitoring and evaluation and impact assessment. This set should serve as a guide for the management of joint ARD activities that are presently developed within the framework of the ERA-ARD project.
Resumo:
Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.
Resumo:
The long-lived radionuclide 129I (T 1/2 = 15.7 My) occurs in the nature in very low concentrations. Since the middle of our century the environmental levels of 129I have been dramatically changed as a consequence of civil and military use of nuclear fission. Its investigation in environmental materials is of interest for environmental surveillance, retrospective dosimetry and for the use as a natural and man-made fracers of environmental processes. We are comparing two analytical methods which presently are capable of determining 129I in environmental materials, namely radiochemical neutron activation analysis (RNAA) and accelerator mass spectrometry (AMS). Emphasis is laid upon the quality control and detection capabilities for the analysis of 129I in environmental materials. Some applications are discussed.
Resumo:
The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.
Resumo:
The aim of our study was to evaluate the quality of histo- and cytomorphological features of PAXgene-fixed specimens and their suitability for histomorphological classification in comparison to standard formalin fixation. Fifteen colon cancer tissues were collected, divided into two mirrored samples and either formalin fixed (FFPE) or PAXgene fixed (PFPE) before paraffin embedding. HE- and PAS-stained sections were scanned and evaluated in a blinded, randomised ring trial by 20 pathologists from Europe and the USA using virtual microscopy. The pathologists evaluated histological grading, histological subtype, presence of adenoma, presence of lymphovascular invasion, quality of histomorphology and quality of nuclear features. Statistical analysis revealed that the reproducibility with regard to grading between both fixation methods was rather satisfactory (weighted kappa statistic (k w) = 0.73 (95 % confidence interval (CI), 0.41-0.94)), with a higher agreement between the reference evaluation and the PFPE samples (k w = 0.86 (95 % CI, 0.67-1.00)). Independent from preservation method, inter-observer reproducibility was not completely satisfactory (k w = 0.60). Histomorphological quality parameters were scored equal or better for PFPE than for FFPE samples. For example, overall quality and nuclear features, especially the detection of mitosis, were judged significantly better for PFPE cases. By contrast, significant retraction artefacts were observed more frequently in PFPE samples. In conclusion, our findings suggest that the PAXgene Tissue System leads to excellent preservation of histomorphology and nuclear features of colon cancer tissue and allows routine morphological diagnosis.