40 resultados para Puget-sound


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sound speed as a diagnostic marker for various diseases of human tissue has been of interest for a while. Up to now, mostly transmission ultrasound computed tomography (UCT) was able to detect spatially resolved sound speed, and its promise as a diagnostic tool has been demonstrated. However, UCT is limited to acoustically transparent samples such as the breast. We present a novel technique where spatially resolved detection of sound speed can be achieved using conventional pulse-echo equipment in reflection mode. For this purpose, pulse-echo images are acquired under various transmit beam directions and a two-dimensional map of the sound speed is reconstructed from the changing phase of local echoes using a direct reconstruction method. Phantom results demonstrate that a high spatial resolution (1 mm) and contrast (0.5 % of average sound speed) can be achieved suitable for diagnostic purposes. In comparison to previous reflection-mode based methods, CUTE works also in a situation with only diffuse echoes, and its direct reconstruction algorithm enables real-time application. This makes it suitable as an addition to conventional clinical ultrasound where it has the potential to benefit diagnosis in a multimodal approach. In addition, knowledge of the spatial distribution of sound speed allows full aberration correction and thus improved spatial resolution and contrast of conventional B-mode ultrasound. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Besides the master clock located in the suprachiasmatic nucleus (SCN) of the brain, additional clocks are distributed across the central nervous system and the body. The role of these 'secondary' clocks remains unclear. A new study shows that the lack of an internal clock in histamine neurons profoundly perturbs sleep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS The safety and efficacy of the interferon-free combination of faldaprevir (NS3/A4 protease inhibitor), deleobuvir (BI 207127, non-nucleoside polymerase inhibitor), and ribavirin in treatment-naïve patients chronically infected with HCV genotype-1 was explored. METHODS SOUND-C3 was a multicenter, open-label Phase 2b study. Treatment-naïve patients chronically infected with HCV genotype-1a (IL28B CC genotype only; n = 12) and genotype-1b (n = 20) were assigned to 16 weeks of treatment with faldaprevir 120 mg once daily, deleobuvir 600 mg twice daily, and weight-based ribavirin. Patients with compensated liver disease, including cirrhosis, were eligible for inclusion in this study. The primary endpoint was sustained virological response 12 weeks after completion of therapy. RESULTS Sustained virological response rates 12 weeks after completion of therapy were 17% and 95% in patients infected with HCV genotype-1a and genotype-1b respectively. All four patients with cirrhosis achieved sustained virological response 12 weeks after completion of therapy. The most frequently reported adverse events of at least moderate intensity were anaemia (16%), nausea, vomiting and fatigue (9% each). Three (9%) patients discontinued because of adverse events. CONCLUSIONS The interferon-free regimen of faldaprevir, deleobuvir and ribavirin was efficacious in patients infected with genotype-1b and generally well tolerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Obtaining new details of radial motion of left ventricular (LV) segments using velocity-encoding cardiac MRI. METHODS Cardiac MR examinations were performed on 14 healthy volunteers aged between 19 and 26 years. Cine images for navigator-gated phase contrast velocity mapping were acquired using a black blood segmented κ-space spoiled gradient echo sequence with a temporal resolution of 13.8 ms. Peak systolic and diastolic radial velocities as well as radial velocity curves were obtained for 16 ventricular segments. RESULTS Significant differences among peak radial velocities of basal and mid-ventricular segments have been recorded. Particular patterns of segmental radial velocity curves were also noted. An additional wave of outward radial movement during the phase of rapid ventricular filling, corresponding to the expected timing of the third heart sound, appeared of particular interest. CONCLUSION The technique has allowed visualization of new details of LV radial wall motion. In particular, higher peak systolic radial velocities of anterior and inferior segments are suggestive of a relatively higher dynamics of anteroposterior vs lateral radial motion in systole. Specific patterns of radial motion of other LV segments may provide additional insights into LV mechanics. ADVANCES IN KNOWLEDGE The outward radial movement of LV segments impacted by the blood flow during rapid ventricular filling provides a potential substrate for the third heart sound. A biphasic radial expansion of the basal anteroseptal segment in early diastole is likely to be related to the simultaneous longitudinal LV displacement by the stretched great vessels following repolarization and their close apposition to this segment.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The limitations of diagnostic echo ultrasound have motivated research into novel modalities that complement ultrasound in a multimodal device. One promising candidate is speed of sound imaging, which has been found to reveal structural changes in diseased tissue. Transmission ultrasound tomography shows speed of sound spatially resolved, but is limited to the acoustically transparent breast. We present a novel method by which speed-of-sound imaging is possible using classic pulse-echo equipment, facilitating new clinical applications and the combination with state-of-the art diagnostic ultrasound. Pulse-echo images are reconstructed while scanning the tissue under various angles using transmit beam steering. Differences in average sound speed along different transmit directions are reflected in the local echo phase, which allows a 2-D reconstruction of the sound speed. In the present proof-of-principle study, we describe a contrast resolution of 0.6% of average sound speed and a spatial resolution of 1 mm (laterally) × 3 mm (axially), suitable for diagnostic applications.