27 resultados para Nanofiber structured cathode


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disorganized behavior is a key symptom of schizophrenia. The objective assessment of disorganized behavior is particularly challenging. Actigraphy has enabled the objective assessment of motor behavior in various settings. Reduced motor activity was associated with negative syndrome scores, but simple motor activity analyses were not informative on other symptom dimensions. The analysis of movement patterns, however, could be more informative for assessing schizophrenia symptom dimensions. Here, we use time series analyses on actigraphic data of 100 schizophrenia spectrum disorder patients. Actigraphy recording intervals were set at 2 s. Data from 2 defined 60-min periods were analyzed, and partial autocorrelations of the actigraphy time series indicated predictability of movements in each individual. Increased positive syndrome scores were associated with reduced predictability of movements but not with the overall amount of movement. Negative syndrome scores were associated with low activity levels but unrelated with predictability of movement. The factors disorganization and excitement were related to movement predictability but emotional distress was not. Thus, the predictability of objectively assessed motor behavior may be a marker of positive symptoms and disorganized behavior. This behavior could become relevant for translational research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transport of radioactive iodide 131I− in a structured clay loam soil under maize in a final growing phase was monitored during five consecutive irrigation experiments under ponding. Each time, 27 mm of water were applied. The water of the second experiment was spiked with 200 MBq of 131I− tracer. Its activity was monitored as functions of depth and time with Geiger-Müller (G-M) detectors in 11 vertically installed access tubes. The aim of the study was to widen our current knowledge of water and solute transport in unsaturated soil under different agriculturally cultivated settings. It was supposed that the change in 131I− activity (or counting rate) is proportional to the change in soil water content. Rapid increase followed by a gradual decrease in 131I− activity occurred at all depths and was attributed to preferential flow. The iodide transport through structured soil profile was simulated by the HYDRUS 1D model. The model predicted relatively deep percolation of iodide within a short time, in a good agreement with the observed vertical iodide distribution in soil. We found that the top 30 cm of the soil profile is the most vulnerable layer in terms of water and solute movement, which is the same depth where the root structure of maize can extend.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction To meet the quality standards for high-stakes OSCEs, it is necessary to ensure high quality standardized performance of the SPs involved.[1] One of the ways this can be assured is through the assessment of the quality of SPs` performance in training and during the assessment. There is some literature concerning validated instruments that have been used to assess SP performance in formative contexts but very little related to high stakes contexts.[2], [3], [4]. Content and structure During this workshop different approaches to quality control for SPs` performance, developed in medicine, pharmacy and nursing OSCEs, will be introduced. Participants will have the opportunity to use these approaches in simulated interactions. Advantages and disadvantages of these approaches will be discussed. Anticipated outcomes By the end of this session, participants will be able to discuss the rationale for quality control of SPs` performance in high stakes OSCEs, outline key factors in creating strategies for quality control, identify various strategies for assuring quality control, and reflect on applications to their own practice. Who should attend The workshop is designed for those interested in quality assurance of SP performance in high stakes OSCEs. Level All levels are welcome. References Adamo G. 2003. Simulated and standardized patients in OSCEs: achievements and challenges:1992-2003. Med Teach. 25(3), 262- 270. Wind LA, Van Dalen J, Muijtjens AM, Rethans JJ. Assessing simulated patients in an educational setting: the MaSP (Maastricht Assessment of Simulated Patients). Med Educ 2004, 38(1):39-44. Bouter S, van Weel-Baumgarten E, Bolhuis S. Construction and validation of the Nijmegen Evaluation of the Simulated Patient (NESP): Assessing Simulated Patients' ability to role-play and provide feedback to students. Acad Med: Journal of the Association of American Medical Colleges 2012. May W, Fisher D, Souder D: Development of an instrument to measure the quality of standardized/simulated patient verbal feedback. Med Educ 2012, 2(1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SPs’ performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Project description SP trainers from five medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). Outcome High quality of SPs’ patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. For example, the rate of completely correct reaction in medical tests increased from 88% to 95%. Together with 4% of sufficient performances these 95% add up to 99% of the reactions in medical tests meeting the standards of the exam. SP educators using the instrument reported an augmentation of SPs’ performance induced by the use of the instrument. Disadvantages mentioned were the high concentration needed to observe all criteria and the cumbersome handling of the paper-based forms. Discussion We were able to document a very high quality of SP performance in our exam. The data also indicates that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed enhancement of performance. The development of an iPad-based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Tuberculosis (TB) is the leading cause of death in South Africa. The burden of disease varies by age, with peaks in TB notification rates in the HIV-negative population at ages 0-5, 20-24, and 45-49 years. There is little variation between age groups in the rates in the HIV-positive population. The drivers of this age pattern remain unknown. METHODS We developed an age-structured simulation model of Mycobacterium tuberculosis (Mtb) transmission in Cape Town, South Africa. We considered five states of TB progression: susceptible, infected (latent TB), active TB, treated TB, and treatment default. Latently infected individuals could be re-infected; a previous Mtb infection slowed progression to active disease. We further considered three states of HIV progression: HIV negative, HIV positive, on antiretroviral therapy. To parameterize the model, we analysed treatment outcomes from the Cape Town electronic TB register, social mixing patterns from a Cape Town community and used literature estimates for other parameters. To investigate the main drivers behind the age patterns, we conducted sensitivity analyses on all parameters related to the age structure. RESULTS The model replicated the age patterns in HIV-negative TB notification rates of Cape Town in 2009. Simulated TB notification rate in HIV-negative patients was 1000/100,000 person-years (pyrs) in children aged <5 years and decreased to 51/100,000 in children 5-15 years. The peak in early adulthood occurred at 25-29 years (463/100,000 pyrs). After a subsequent decline, simulated TB notification rates gradually increased from the age of 30 years. Sensitivity analyses showed that the dip after the early adult peak was due to the protective effect of latent TB and that retreatment TB was mainly responsible for the rise in TB notification rates from the age of 30 years. CONCLUSION The protective effect of a first latent infection on subsequent infections and the faster progression in previously treated patients are the key determinants of the age-structure of TB notification rates in Cape Town.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Resuscitation guidelines encourage the use of cardiopulmonary resuscitation (CPR) feedback devices implying better outcomes after sudden cardiac arrest. Whether effective continuous feedback could also be given verbally by a second rescuer ("human feedback") has not been investigated yet. We, therefore, compared the effect of human feedback to a CPR feedback device. METHODS In an open, prospective, randomised, controlled trial, we compared CPR performance of three groups of medical students in a two-rescuer scenario. Group "sCPR" was taught standard BLS without continuous feedback, serving as control. Group "mfCPR" was taught BLS with mechanical audio-visual feedback (HeartStart MRx with Q-CPR-Technology™). Group "hfCPR" was taught standard BLS with human feedback. Afterwards, 326 medical students performed two-rescuer BLS on a manikin for 8 min. CPR quality parameters, such as "effective compression ratio" (ECR: compressions with correct hand position, depth and complete decompression multiplied by flow-time fraction), and other compression, ventilation and time-related parameters were assessed for all groups. RESULTS ECR was comparable between the hfCPR and the mfCPR group (0.33 vs. 0.35, p = 0.435). The hfCPR group needed less time until starting chest compressions (2 vs. 8 s, p < 0.001) and showed fewer incorrect decompressions (26 vs. 33 %, p = 0.044). On the other hand, absolute hands-off time was higher in the hfCPR group (67 vs. 60 s, p = 0.021). CONCLUSIONS The quality of CPR with human feedback or by using a mechanical audio-visual feedback device was similar. Further studies should investigate whether extended human feedback training could further increase CPR quality at comparable costs for training.