201 resultados para METALLIC STENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore8 and 16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacteria, yeasts, and viruses are rapidly killed on metallic copper surfaces, and the term "contact killing" has been coined for this process. While the phenomenon was already known in ancient times, it is currently receiving renewed attention. This is due to the potential use of copper as an antibacterial material in health care settings. Contact killing was observed to take place at a rate of at least 7 to 8 logs per hour, and no live microorganisms were generally recovered from copper surfaces after prolonged incubation. The antimicrobial activity of copper and copper alloys is now well established, and copper has recently been registered at the U.S. Environmental Protection Agency as the first solid antimicrobial material. In several clinical studies, copper has been evaluated for use on touch surfaces, such as door handles, bathroom fixtures, or bed rails, in attempts to curb nosocomial infections. In connection to these new applications of copper, it is important to understand the mechanism of contact killing since it may bear on central issues, such as the possibility of the emergence and spread of resistant organisms, cleaning procedures, and questions of material and object engineering. Recent work has shed light on mechanistic aspects of contact killing. These findings will be reviewed here and juxtaposed with the toxicity mechanisms of ionic copper. The merit of copper as a hygienic material in hospitals and related settings will also be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular stent grafting represents a novel concept for type B aortic dissection both in the acute and subacute/chronic setting, with an unknown effect on outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aims to identify risk constellations for symptomatic spinal cord malperfusion in patients undergoing extensive stent-graft coverage of the thoracic aorta.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre has the potential for immediate and delayed neurological and vascular symptoms. Some authors, therefore, propose prophylactic revascularisation of the LSA by transposition or bypass, while others suggest prophylactic revascularisation only under certain conditions, and still others see no requirement for prophylactic revascularisation in anticipation of LSA ostium coverage. In this review about LSA revascularisation in TEVAR patients with coverage of the LSA, we searched the electronic databases MEDLINE and EMBASE historically until the end date of May 2010 with the search terms left subclavian artery, covering, endovascular, revascularisation and thoracic aorta. We have gathered the most complete scientific evidence available used to support the various concepts to deal with this issue. After a review of the current available literature, 23 relevant articles were found, where we have identified and analysed three basic treatment concepts for LSA revascularisation in TEVAR patients (prophylactic, conditional prophylactic and no prophylactic LSA revascularisation). The available evidence supports prophylactic revascularisation of the LSA before ESG LSA coverage when preoperative imaging reveals abnormal supra-aortic vascular anatomy or pathology. We further conclude that elective patients undergoing planned coverage of the LSA during TEVAR should receive prophylactic LSA transposition or LSA-to-left-common-carotid-artery (LCCA) bypass surgery to prevent severe neurological complications, such as paraplegia or brain stem infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the safety and performance of Relay stent-grafts in patients with acute or chronic aortic dissections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to compare the neointimal response of metallic everolimus drug-eluting stents (DES) and polymeric everolimus bioresorbable vascular scaffolds (BVS) by optical coherence tomography at 1 year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vessel angulation and large changes in vessel geometry after stent implantation have been associated with an increased risk of target lesion failure (TLF) using bare-metal stents. Second-generation drug-eluting stents (DES)offer superior conformability and inhibition of neointima. The aim of the study is to investigate the relationship between pre and post-implant vessel geometry and the occurrence of TLF at 1 year after treatment with second-generation DES; and to compare the conformability of Resolute and Xience stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). Methods and results: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. Conclusions: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. - See more at: http://www.pcronline.com/eurointervention/42nd_issue/125/#sthash.E5HhMQ4a.dpuf