24 resultados para Karolinska Sleepiness Scale performance
Resumo:
Background: Residents demonstrate a broad range of performance levels for clinical skills, with some at an inadequate level. Adequate self-assessment is important for life long learning. However, its accuracy is questioned extensively. The aim of this study was to evaluate how far the residents’ self-assessment predicts their performance in an expert assessment of emergency skills. Summary of work: Twelve skills were identified as being relevant for the emergency duties of residents in smaller hospitals. Fifteen first-year residents from the departments of internal medicine and general surgery at a district hospital rated their performance on a questionnaire (self-assessment). This was followed by a structured, practical in vivo assessment by an anaesthesiologist (expert assessment). For both, a visual analogue scale from 0 to 10 was used, on which 0 stands for novice and 10 for expert. Predictive validity was described by Spearman’s correlation, which was significant in 3 out of 12 skills only. Median correlation (r) was 0.50 (range 0.16 to 0.93). Conclusion: At the beginning of postgraduate training, self-assessment alone is not sufficient to guide self-directed learning. Take-home message: At the beginning of their residency, physicians need structured feedback in emergency skills which can be offered by anaesthesiologists.
Resumo:
Background: To detect attention deficit hyperactivity disorder (ADHD) in treatment seeking substance use disorders (SUD) patients, a valid screening instrument is needed. Objectives: To test the performance of the Adult ADHD Self-Report Scale V 1.1(ASRS) for adult ADHD in an international sample of treatment seeking SUD patients for DSM-IV-TR; for the proposed DSM-5 criteria; in different subpopulations, at intake and 1–2 weeks after intake; using different scoring algorithms; and different externalizing disorders as external criterion (including adult ADHD, bipolar disorder, antisocial and borderline personality disorder). Methods: In 1138 treatment seeking SUD subjects, ASRS performance was determined using diagnoses based on Conner's Adult ADHD Diagnostic Interview for DSM-IV (CAADID) as gold standard. Results: The prevalence of adult ADHD was 13.0% (95% CI: 11.0–15.0%). The overall positive predictive value (PPV) of the ASRS was 0.26 (95% CI: 0.22–0.30), the negative predictive value (NPV) was 0.97 (95% CI: 0.96–0.98). The sensitivity (0.84, 95% CI: 0.76–0.88) and specificity (0.66, 95% CI: 0.63–0.69) measured at admission were similar to the sensitivity (0.88, 95% CI: 0.83–0.93) and specificity (0.67, 95% CI: 0.64–0.70) measured 2 weeks after admission. Sensitivity was similar, but specificity was significantly better in patients with alcohol compared to (illicit) drugs as the primary substance of abuse (0.76 vs. 0.56). ASRS was not a good screener for externalizing disorders other than ADHD. Conclusions: The ASRS is a sensitive screener for identifying possible ADHD cases with very few missed cases among those screening negative in this population.
Resumo:
Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow.
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Motivational research over the past decade has provided ample evidence for the existence of two distinct motivational systems. Implicit motives are affect-based needs and have been found to predict spontaneous behavioral trends over time. Explicit motives in contrast represent cognitively based self-attributes and are preferably linked to choices. The present research examines the differentiating and predictive value of the implicit vs. explicit achievement motives for team sports performances. German students (N = 42) completed a measure of the implicit (Operant Motive Test) and the explicit achievement motive (Achievement Motive Scale-Sport). Choosing a goal distance is significantly predicted by the explicit achievement motive measure. By contrast, repeated performances in a team tournament are significantly predicted by the indirect measure. Results are in line with findings showing that implicit and explicit motive measures are associated with different classes of behavior.
Resumo:
Due to the ongoing trend towards increased product variety, fast-moving consumer goods such as food and beverages, pharmaceuticals, and chemicals are typically manufactured through so-called make-and-pack processes. These processes consist of a make stage, a pack stage, and intermediate storage facilities that decouple these two stages. In operations scheduling, complex technological constraints must be considered, e.g., non-identical parallel processing units, sequence-dependent changeovers, batch splitting, no-wait restrictions, material transfer times, minimum storage times, and finite storage capacity. The short-term scheduling problem is to compute a production schedule such that a given demand for products is fulfilled, all technological constraints are met, and the production makespan is minimised. A production schedule typically comprises 500–1500 operations. Due to the problem size and complexity of the technological constraints, the performance of known mixed-integer linear programming (MILP) formulations and heuristic approaches is often insufficient. We present a hybrid method consisting of three phases. First, the set of operations is divided into several subsets. Second, these subsets are iteratively scheduled using a generic and flexible MILP formulation. Third, a novel critical path-based improvement procedure is applied to the resulting schedule. We develop several strategies for the integration of the MILP model into this heuristic framework. Using these strategies, high-quality feasible solutions to large-scale instances can be obtained within reasonable CPU times using standard optimisation software. We have applied the proposed hybrid method to a set of industrial problem instances and found that the method outperforms state-of-the-art methods.
Resumo:
BackgroundInfection pathways of S. aureus udder infections in heifers are still not well understood. One hypothesis is that calves become infected with S. aureus via feeding mastitis milk. Especially on small-scale farms, pasteurisers are not economic. The purpose of this randomised comparative study was to investigate the influence of feeding milk containing S. aureus genotype B (SAGTB) on the health and development of calves and udder health of the respective heifers. Additionally, a method reducing the bacterial load to obtain safer feeding milk was tested. Thirty-four calves were fed mastitis milk from cows with subclinical SAGTB mastitis. One group was fed untreated milk (UMG). For the other group, milk was thermised at 61°C for one minute (heat treated milk group¿=¿HMG). After weaning, calves were followed up until first calving. A milk sample of these heifers was taken at first milking to compare udder health of both groups.ResultsThermisation of milk led to an effective reduction of S. aureus in the feeding milk. 78% of the analysed pools were free of S. aureus, a reduction of at least one log was obtained in the other pools.Quarter milk samples revealed that two heifers had a S. aureus intramammary infection, but caused by a genotype different from genotype B.During the suckling period, the UMG had a significantly higher incidence rate of 1.09 diarrhoea cases per 100 calf days at risk compared to 0.26 cases per 100 calf days in the HMG (p¿<¿0.05).ConclusionsUnder the conditions of this study, no effects of feeding milk containing SAGTB on udder health after first calving were observed. But a power analysis indicated that the sample size in the current setup is insufficient to allow for assessment on mastitis risk after SAGTB exposition, as a minimal number of 4 calves infected (vs. 0 in the HMG) would have shown significant effects. High bacterial load, however, was associated with an increased incidence rate of diarrhoea. Thus, thermisation as a minimal preventive measure before feeding mastitis milk to calves might be beneficial for maintaining calf health.
Resumo:
This paper presents the performance of the ATLAS muon reconstruction during the LHC run with pp collisions at √s = 7–8 TeV in 2011–2012, focusing mainly on data collected in 2012. Measurements of the reconstruction efficiency and of the momentum scale and resolution, based on large reference samples of J/ψ → μμ, Z → μμ and ϒ → μμ decays, are presented and compared to Monte Carlo simulations. Corrections to the simulation, to be used in physics analysis, are provided. Over most of the covered phase space (muon |η| < 2.7 and 5 ≲ pT ≲ 100 GeV) the efficiency is above 99% and is measured with per-mille precision. The momentum resolution ranges from 1.7% at central rapidity and for transverse momentum pT ≅ 10 GeV, to 4% at large rapidity and pT ≅ 100 GeV. The momentum scale is known with an uncertainty of 0.05% to 0.2% depending on rapidity. A method for the recovery of final state radiation from the muons is also presented.
Resumo:
OBJECTIVE To test whether sleep-deprived, healthy subjects who do not always signal spontaneously perceived sleepiness (SPS) before falling asleep during the Maintenance of Wakefulness Test (MWT) would do so in a driving simulator. METHODS Twenty-four healthy subjects (20-26 years old) underwent a MWT for 40 min and a driving simulator test for 1 h, before and after one night of sleep deprivation. Standard electroencephalography, electrooculography, submental electromyography, and face videography were recorded simultaneously to score wakefulness and sleep. Subjects were instructed to signal SPS as soon as they subjectively felt sleepy and to try to stay awake for as long as possible in every test. They were rewarded for both "appropriate" perception of SPS and staying awake for as long as possible. RESULTS After sleep deprivation, seven subjects (29%) did not signal SPS before falling asleep in the MWT, but all subjects signalled SPS before falling asleep in the driving simulator (p <0.004). CONCLUSIONS The previous results of an "inaccurate" SPS in the MWT were confirmed, and a perfect SPS was shown in the driving simulator. It was hypothesised that SPS is more accurate for tasks involving continuous feedback of performance, such as driving, compared to the less active situation of the MWT. Spontaneously perceived sleepiness in the MWT cannot be used to judge sleepiness perception while driving. Further studies are needed to define the accuracy of SPS in working tasks or occupations with minimal or no performance feedback.