353 resultados para Hip Fractures


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Obturator anterior hip dislocation is very rare. Poor results are described in patients with additional large transchondral fractures and treatment of these injuries remains challenging. Appropriate treatment recommendations are missing in the literature. This case report introduces surgical hip dislocation for osteochondral autograft transplantation with graft harvest from the nonweightbearing area of the head-neck junction as a salvage procedure in a large femoral head defect. We report the treatment and outcome of a 48-year-old man who sustained an anterior dislocation of the left hip after a motorcycle accident. After initial closed reduction in the emergency room, imaging analysis revealed a large osteochondral defect of the femoral head within the weightbearing area (10 × 20 mm, depth: 5 mm). The hip was exposed with a surgical hip dislocation using a trochanteric osteotomy. An osteochondral autograft was harvested from a nonweightbearing area of the femoral head and transferred into the defect. The patient was prospectively examined clinically and radiologically. Two years postoperatively, the patient was free of pain and complaints. The function of the injured hip was comparable to that of the contralateral, healthy hip and showed satisfying radiologic results. Surgical hip dislocation with a trochanteric flip osteotomy is a simple, one-step technique that allows full inspection of the hip to treat osteochondral femoral defects by osteochondral transplantation. The presented technique, used as a salvage procedure in a large femoral head defect, yielded good clinical and satisfying radiologic outcomes at the midterm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteotomies of the proximal femur and stable fixation of displaced femoral neck fractures are demanding operations. An LCP Paediatric Hip Plate was developed to make these operations safer and less demanding. The article focuses on the surgical technique and critically analyses the device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a randomly selected cohort of Swiss community-dwelling elderly women prospectively followed up for 2.8 +/- 0.6 years, clinical fractures were assessed twice yearly. Bone mineral density (BMD) measured at tibial diaphysis (T-DIA) and tibial epiphysis (T-EPI) using dual-energy X-ray absorptiometry (DXA) was shown to be a valid alternative to lumbar spine or hip BMD in predicting fractures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Data concerning outcome after management of acetabular fractures by anterior approaches with focus on age and fractures associated with roof impaction, central dislocation and/or quadrilateral plate displacement are rare. METHODS Between October 2005 and April 2009 a series of 59 patients (mean age 57 years, range 13-91) with fractures involving the anterior column was treated using the modified Stoppa approach alone or for reduction of displaced iliac wing or low anterior column fractures in combination with the 1st window of the ilioinguinal approach or the modified Smith-Petersen approach, respectively. Surgical data, accuracy of reduction, clinical and radiographic outcome at mid-term and the need for endoprosthetic replacement in the postoperative course (defined as failure) were assessed; uni- and multivariate regression analysis were performed to identify independent predictive factors (e.g. age, nonanatomical reduction, acetabular roof impaction, central dislocation, quadrilateral plate displacement) for a failure. Outcome was assessed for all patients in general and in accordance to age in particular; patients were subdivided into two groups according to their age (group "<60yrs", group "≥60yrs"). RESULTS Forty-three of 59 patients (mean age 54yrs, 13-89) were available for evaluation. Of these, anatomic reduction was achieved in 72% of cases. Nonanatomical reduction was identified as being the only multivariate predictor for subsequent total hip replacement (Adjusted Hazard Ratio 23.5; p<0.01). A statistically significant higher rate of nonanatomical reduction was observed in the presence of acetabular roof impaction (p=0.01). In 16% of all patients, total hip replacement was performed and in 69% of patients with preserved hips the clinical results were excellent or good at a mean follow up of 35±10 months (range: 24-55). No statistical significant differences were observed between both groups. CONCLUSION Nonanatomical reconstruction of the articular surfaces is at risk for failure of joint-preserving management of acetabular fractures through an isolated or combined modified Stoppa approach resulting in total joint replacement at mid-term. In the elderly, joint-preserving surgery is worth considering as promising clinical and radiographic results might be obtained at mid-term.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In postmenopausal women, yearly intravenous zoledronate (ZOL) compared to placebo (PLB) significantly increased bone mineral density (BMD) at lumbar spine (LS), femoral neck (FN), and total hip (TH) and decreased fracture risk. The effects of ZOL on BMD at the tibial epiphysis (T-EPI) and diaphysis (T-DIA) are unknown. METHODS A randomized controlled ancillary study of the HORIZON trial was conducted at the Department of Osteoporosis of the University Hospital of Berne, Switzerland. Women with ≥1 follow-up DXA measurement who had received ≥1 dose of either ZOL (n=55) or PLB (n=55) were included. BMD was measured at LS, FN, TH, T-EPI, and T-DIA at baseline, 6, 12, 24, and 36 months. Morphometric vertebral fractures were assessed. Incident clinical fractures were recorded as adverse events. RESULTS Baseline characteristics were comparable with those in HORIZON and between groups. After 36 months, BMD was significantly higher in women treated with ZOL vs. PLB at LS, FN, TH, and T-EPI (+7.6%, +3.7%, +5.6%, and +5.5%, respectively, p<0.01 for all) but not T-DIA (+1.1%). The number of patients with ≥1 incident non-vertebral or morphometric fracture did not differ between groups (9 ZOL/11 PLB). Mean changes in BMD did not differ between groups with and without incident fracture, except that women with an incident non-vertebral fracture had significantly higher bone loss at predominantly cortical T-DIA (p=0.005). CONCLUSION ZOL was significantly superior to PLB at T-EPI but not at T-DIA. Women with an incident non-vertebral fracture experienced bone loss at T-DIA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background.  The impact of human genetic background on low-trauma fracture (LTF) risk has not been evaluated in the context of human immunodeficiency virus (HIV) and clinical LTF risk factors. Methods.  In the general population, 6 common single-nucleotide polymorphisms (SNPs) associate with LTF through genome-wide association study. Using genome-wide SNP arrays and imputation, we genotyped these SNPs in HIV-positive, white Swiss HIV Cohort Study participants. We included 103 individuals with a first, physician-validated LTF and 206 controls matched on gender, whose duration of observation and whose antiretroviral therapy start dates were similar using incidence density sampling. Analyses of nongenetic LTF risk factors were based on 158 cases and 788 controls. Results.  A genetic risk score built from the 6 LTF-associated SNPs did not associate with LTF risk, in both models including and not including parental hip fracture history. The contribution of clinical LTF risk factors was limited in our dataset. Conclusions.  Genetic LTF markers with a modest effect size in the general population do not improve fracture prediction in persons with HIV, in whom clinical LTF risk factors are prevalent in both cases and controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer. METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment. RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment hip IR in our population-based inception cohort study of young asymptomatic males. It was strongly correlated with standard clinical assessment of IR but was considerably more reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A classification of injuries is necessary in order to develop a common language for treatment indications and outcomes. Several classification systems have been proposed, the most frequently used is the Denis classification. The problem of this classification system is that it is based on an assumption, which is anatomically unidentifiable: the so-called middle column. For this reason, few years ago, a group of spine surgeons has developed a new classification system, which is based on the severity of the injury. The severity is defined by the pathomorphological findings, the prognosis in terms of healing and potential of neurological damage. This classification is based on three major groups: A = isolated anterior column injuries by axial compression, B = disruption of the posterior ligament complex by distraction posteriorly, and group C = corresponding to group B but with rotation. There is an increasing severity from A to C, and within each group, the severity usually increases within the subgroups from .1, .2, .3. All these pathomorphologies are supported by a mechanism of injury, which is responsible for the extent of the injury. The type of injury with its groups and subgroups is able to suggest the treatment modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to clarify the occurrence and types of dental injuries in 389 patients who had been diagnosed with facial fractures, and to analyze whether the occurrence of dental injury correlates to gender, age, trauma mechanism and type of facial fracture. Dental injuries were observed in 62 patients (16%). The most common type of injury was a crown fracture (48%). Dental injuries were multiple in most patients (63%). Almost half (48%) of all injured teeth were severely injured. Most injured teeth (61%) were in the maxilla. The incisor region was the most prevalent site in both the mandible (45%) and the maxilla (56%). The occurrence of dental injury correlated significantly with trauma mechanism and fracture type: motor vehicle accidents and mandibular fracture were significant predictors for dental trauma. The notable rate of dental injury observed in the present study emphasizes the importance of a thorough examination of the oral cavity in all patients who have sustained facial fracture. Referral to a dental practice for further treatment and follow up as soon as possible after discharge from hospital is fundamental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.