37 resultados para Hand-to-hand fighting, Oriental


Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of our prospective study was to document the clinical and radiological results of conservative-functional treatment of extraarticular proximal phalangeal fractures without immobilisation of the wrist.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We report on a father and daughter with hand-foot-genital syndrome (HFGS) with typical skeletal and genitourinary anomalies due to a 14-residue polyalanine expansion in HOXA13. This is the largest (32 residues) polyalanine tract so far described for any polyalanine mutant protein. Polyalanine expansion results in protein misfolding, cytoplasmic aggregation and degradation; however, HOXA13 polyalanine expansions appear to act as loss of function mutations in contrast to gain of function for HOXD13 polyalanine expansions. To address this paradox we examined the cellular consequences of polyalanine expansions on HOXA13 protein using COS cell transfection and immunocytochemistry. HOXA13 polyalanine expansion proteins form cytoplasmic aggregates, and distribution between cytoplasmic aggregates or the nucleus is polyalanine tract size-dependent. Geldanamycin, an Hsp90 inhibitor, reduces the steady-state abundance of all polyalanine-expanded proteins in transfected cells. We also found that wild-type HOXA13 or HOXD13 proteins are sequestered in HOXA13 polyalanine expansion cytoplasmic aggregates. Thus, the difference between HOXA13 polyalanine expansion loss-of-function and HOXD13 polyalanine expansion dominant-negative effect is not the ability to aggregate wild-type group 13 paralogs but perhaps to variation in activities associated with refolding, aggregation or degradation of the proteins.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The optimal testing position for hand grip strength, which is a useful functional measure of nutritional status, is open to debate. We therefore examined the systematic difference between different postures in order to establish a methodology that is clinically relevant, easy to perform and reproducible.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The scaphoid is the most frequently fractured carpal bone. When investigating fixation stability, which may influence healing, knowledge of forces and moments acting on the scaphoid is essential. The aim of this study was to evaluate cartilage contact forces acting on the intact scaphoid in various functional wrist positions using finite element modeling. A novel methodology was utilized as an attempt to overcome some limitations of earlier studies, namely, relatively coarse imaging resolution to assess geometry, assumption of idealized cartilage thicknesses and neglected cartilage pre-stresses in the unloaded joint. Carpal bone positions and articular cartilage geometry were obtained independently by means of high resolution CT imaging and incorporated into finite element (FE) models of the human wrist in eight functional positions. Displacement driven FE analyses were used to resolve inter-penetration of cartilage layers, and provided contact areas, forces and pressure distribution for the scaphoid bone. The results were in the range reported by previous studies. Novel findings of this study were: (i) cartilage thickness was found to be heterogeneous for each bone and vary considerably between carpal bones; (ii) this heterogeneity largely influenced the FE results and (iii) the forces acting on the scaphoid in the unloaded wrist were found to be significant. As major limitations, accuracy of the method was found to be relatively low, and the results could not be compared to independent experiments. The obtained results will be used in a following study to evaluate existing and recently developed screws used to fix scaphoid fractures.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND Bodily sensations are an important component of corporeal awareness. Spinal cord injury can leave affected body parts insentient and unmoving, leading to specific disturbances in the mental representation of one's own body and the sense of self. OBJECTIVE Here, we explored how illusions induced by multisensory stimulation influence immediate sensory signals and tactile awareness in patients with spinal cord injuries. METHODS The rubber hand illusion paradigm was applied to 2 patients with chronic and complete spinal cord injury of the sixth cervical spine, with severe somatosensory impairments in 2 of 5 fingers. RESULTS Both patients experienced a strong illusion of ownership of the rubber hand during synchronous, but not asynchronous, stroking. They also, spontaneously reported basic tactile sensations in their previously numb fingers. Tactile awareness from seeing the rubber hand was enhanced by progressively increasing the stimulation duration. CONCLUSIONS Multisensory illusions directly and specifically modulate the reemergence of sensory memories and enhance tactile sensation, despite (or as a result of) prior deafferentation. When sensory inputs are lost, and are later illusorily regained, the brain updates a coherent body image even several years after the body has become permanently unable to feel. This particular example of neural plasticity represents a significant opportunity to strengthen the sense of the self and the feelings of embodiment in patients with spinal cord injury.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND Hand eczema has a high impact on patients' quality of life. The treatment focuses on improving skin barrier function. OBJECTIVES To evaluate the effects and acceptance of a novel educational program for patients with hand eczema. METHODS Retrospectively, the records of 36 patients who attended the prevention program and follow-up visits were analyzed. Physician global assessment (PGA) scores, acceptance and behavioral changes were assessed. RESULTS In 67% of patients, an improvement of the hand eczema could be attributed to the effects of our educational program. The mean PGA score significantly decreased from 3 before education to 2.2 during follow-up. Behavioral changes in both skin care and protection were reported in 81 and 86%, respectively. CONCLUSIONs: Our educational program had a positive effect on clinical outcome as well as adherence to skin care and protection measures. Its integration in a hand eczema clinic was feasible and well accepted by the patients.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In the present study we examined the interrelation of everyday life handedness and hand preference in basketball, as an area of expertise that requires individuals being proficient with both their nondominant and dominant hand. A secondary aim was to elucidate the link between basketball-specific practice, hand preference in basketball and everyday life handedness. Therefore, 176 expert basketball players self-reported their hand preference for activities of daily living and for basketball-specific behavior as well as details about their basketball-specific history via questionnaire. We found that compared to the general population the one-hand bias was significantly reduced for both everyday life and basketball-specific hand preference (i.e., a higher prevalence of mixed-handed individuals), and that both concepts were significantly related. Moreover, only preference scores for lay-up and dribbling skills were significantly related to measures of basketball-specific practice. Consequently, training-induced modulations of lateral preference seem to be very specific to only a few basketball-specific skills, and do not generalize to other skills within the domain of basketball nor do they extend into everyday life handedness. The results are discussed in terms of their relevance regarding theories of handedness and their practical implications for the sport of basketball.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The treatment of neuropathic pain challenges not only doctors but also hand therapists, since a majority of patients don't experience a significant pain relief despite systemic pain treatment. Early diagnosis of neuropathic pain and a therapeutic concept is crucial to meet the individual needs of the patient. The complexity of a pain syndrome calls for a multidisciplinary approach using patient education, pharmacological and non-pharmacological therapies, such as graded motor imagery or somatosensory rehabilitation, behavioral therapy and physical measures. The evidence of the above mentioned therapies with regards to neuropathic pain is not yet completely established. Possible reasons are the lack of complete understanding of the pain causing mechanisms and the fact of treating the symptoms rather than the cause.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In many surgical disciplines the ultrasound examination is performed by the surgeon himself. With the development of high-resolution ultrasound, hand surgeons use this diagnostic tool more and more to visualize the patient's hand anatomy noninvasively. This article gives an introduction to performing the ultrasound examination in the hand and how to interpret the findings correctly. Additionally, the top ten indications for ultrasound usage in the hand are illustrated.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND Unilateral ischemic stroke disrupts the well balanced interactions within bilateral cortical networks. Restitution of interhemispheric balance is thought to contribute to post-stroke recovery. Longitudinal measurements of cerebral blood flow (CBF) changes might act as surrogate marker for this process. OBJECTIVE To quantify longitudinal CBF changes using arterial spin labeling MRI (ASL) and interhemispheric balance within the cortical sensorimotor network and to assess their relationship with motor hand function recovery. METHODS Longitudinal CBF data were acquired in 23 patients at 3 and 9 months after cortical sensorimotor stroke and in 20 healthy controls using pulsed ASL. Recovery of grip force and manual dexterity was assessed with tasks requiring power and precision grips. Voxel-based analysis was performed to identify areas of significant CBF change. Region-of-interest analyses were used to quantify the interhemispheric balance across nodes of the cortical sensorimotor network. RESULTS Dexterity was more affected, and recovered at a slower pace than grip force. In patients with successful recovery of dexterous hand function, CBF decreased over time in the contralesional supplementary motor area, paralimbic anterior cingulate cortex and superior precuneus, and interhemispheric balance returned to healthy control levels. In contrast, patients with poor recovery presented with sustained hypoperfusion in the sensorimotor cortices encompassing the ischemic tissue, and CBF remained lateralized to the contralesional hemisphere. CONCLUSIONS Sustained perfusion imbalance within the cortical sensorimotor network, as measured with task-unrelated ASL, is associated with poor recovery of dexterous hand function after stroke. CBF at rest might be used to monitor recovery and gain prognostic information.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We propose a method to acquire 3D light fields using a hand-held camera, and describe several computational photography applications facilitated by our approach. As our input we take an image sequence from a camera translating along an approximately linear path with limited camera rotations. Users can acquire such data easily in a few seconds by moving a hand-held camera. We include a novel approach to resample the input into regularly sampled 3D light fields by aligning them in the spatio-temporal domain, and a technique for high-quality disparity estimation from light fields. We show applications including digital refocusing and synthetic aperture blur, foreground removal, selective colorization, and others.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Recent research in cognitive sciences shows a growing interest in spatial-numerical associations. The horizontal SNARC (spatial-numerical association of response codes) effect is defined by faster left-sided responses to small numbers and faster right-sided responses to large numbers in a parity judgment task. In this study we investigated whether there is also a SNARC effect for upper and lower responses. The grounded cognition approach suggests that the universal experience of "more is up" serves as a robust frame of reference for vertical number representation. In line with this view, lower hand responses to small numbers were faster than to large numbers (Experiment 1). Interestingly, the vertical SNARC effect reversed when the lower responses were given by foot instead of the hand (Experiments 2, 3, and 4). We found faster upper (hand) responses to small numbers and faster lower (foot) responses to large numbers. Additional experiments showed that spatial factors cannot account for the reversal of the vertical SNARC effect (Experiments 4 and 5). Our results question the view of "more is up" as a robust frame of reference for spatial-numerical associations. We discuss our results within a hierarchical framework of numerical cognition and point to a possible link between effectors and number representation.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND Guidelines recommend that health care personnel (HCP) wear gloves for all interactions with patients on contact precautions. We aimed to assess hand hygiene (HH) compliance during contact precautions before and after eliminating mandatory glove use. METHODS We assessed HH compliance of HCP in the care of patients on contact precautions in 50 series before (2009) and 6 months after (2012) eliminating mandatory glove use and compared these results with the hospital-wide HH compliance. RESULTS We assessed 426 HH indications before and 492 indications after the policy change. Compared with 2009, we observed a significantly higher HH compliance in patients on contact precautions in 2012 (52%; 95% confidence interval [95% CI], 47-57) vs 85%; 95% CI, 82-88; P < .001). During the same period, hospital-wide HH compliance also increased from 63% (95% CI, 61-65) to 81% (95% CI 80-83) (P < .001). However, the relative improvement (RI) of HH compliance during contact precautions was significantly higher than the hospital-wide relative improvement (RI, 1.6; 95% CI, 1.49-1.81 vs 1.29; 95% CI, 1.25-1.34), with a relative improvement ratio of 1.27 (95% CI, 1.15-1.41). CONCLUSION Eliminating mandatory glove use in the care of patients on contact precautions increased HH compliance in our institution, particularly before invasive procedures and before patient contacts. Further studies on the effect on pathogen transmission are needed before revisiting the current official guidelines on the topic.