41 resultados para Error Bounds
Resumo:
Justification Logic studies epistemic and provability phenomena by introducing justifications/proofs into the language in the form of justification terms. Pure justification logics serve as counterparts of traditional modal epistemic logics, and hybrid logics combine epistemic modalities with justification terms. The computational complexity of pure justification logics is typically lower than that of the corresponding modal logics. Moreover, the so-called reflected fragments, which still contain complete information about the respective justification logics, are known to be in~NP for a wide range of justification logics, pure and hybrid alike. This paper shows that, under reasonable additional restrictions, these reflected fragments are NP-complete, thereby proving a matching lower bound. The proof method is then extended to provide a uniform proof that the corresponding full pure justification logics are $\Pi^p_2$-hard, reproving and generalizing an earlier result by Milnikel.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
QUESTION UNDER STUDY To establish at what stage Swiss hospitals are in implementing an internal standard concerning communication with patients and families after an error that resulted in harm. METHODS Hospitals were identified via the Swiss Hospital Association's website. An anonymous questionnaire was sent during September and October 2011 to 379 hospitals in German, French or Italian. Hospitals were asked to specify their hospital type and the implementation status of an internal hospital standard that decrees that patients or their relatives are to be promptly informed about medical errors that result in harm. RESULTS Responses from a total of 205 hospitals were received, a response rate of 54%. Most responding hospitals (62%) had an error disclosure standard or planned to implement one within 12 months. The majority of responding university and acute care (75%) hospitals had introduced a disclosure standard or were planning to do so. In contrast, the majority of responding psychiatric, rehabilitation and specialty (53%) clinics had not introduced a standard. CONCLUSION It appears that Swiss hospitals are in a promising state in providing institutional support for practitioners disclosing medical errors to patients. This has been shown internationally to be one important factor in encouraging the disclosure of medical errors. However, many hospitals, in particular psychiatric, rehabilitation and specialty clinics, have not implemented an error disclosure policy. Further research is needed to explore the underlying reasons.
Resumo:
If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy.
Resumo:
In this article, we develop the a priori and a posteriori error analysis of hp-version interior penalty discontinuous Galerkin finite element methods for strongly monotone quasi-Newtonian fluid flows in a bounded Lipschitz domain Ω ⊂ ℝd, d = 2, 3. In the latter case, computable upper and lower bounds on the error are derived in terms of a natural energy norm, which are explicit in the local mesh size and local polynomial degree of the approximating finite element method. A series of numerical experiments illustrate the performance of the proposed a posteriori error indicators within an automatic hp-adaptive refinement algorithm.
Resumo:
Localized Magnetic Resonance Spectroscopy (MRS) is in widespread use for clinical brain research. Standard acquisition sequences to obtain one-dimensional spectra suffer from substantial overlap of spectral contributions from many metabolites. Therefore, specially tuned editing sequences or two-dimensional acquisition schemes are applied to extend the information content. Tuning specific acquisition parameters allows to make the sequences more efficient or more specific for certain target metabolites. Cramér-Rao bounds have been used in other fields for optimization of experiments and are now shown to be very useful as design criteria for localized MRS sequence optimization. The principle is illustrated for one- and two-dimensional MRS, in particular the 2D separation experiment, where the usual restriction to equidistant echo time spacings and equal acquisition times per echo time can be abolished. Particular emphasis is placed on optimizing experiments for quantification of GABA and glutamate. The basic principles are verified by Monte Carlo simulations and in vivo for repeated acquisitions of generalized two-dimensional separation brain spectra obtained from healthy subjects and expanded by bootstrapping for better definition of the quantification uncertainties.
Resumo:
Next-generation sequencing (NGS) is a valuable tool for the detection and quantification of HIV-1 variants in vivo. However, these technologies require detailed characterization and control of artificially induced errors to be applicable for accurate haplotype reconstruction. To investigate the occurrence of substitutions, insertions, and deletions at the individual steps of RT-PCR and NGS, 454 pyrosequencing was performed on amplified and non-amplified HIV-1 genomes. Artificial recombination was explored by mixing five different HIV-1 clonal strains (5-virus-mix) and applying different RT-PCR conditions followed by 454 pyrosequencing. Error rates ranged from 0.04-0.66% and were similar in amplified and non-amplified samples. Discrepancies were observed between forward and reverse reads, indicating that most errors were introduced during the pyrosequencing step. Using the 5-virus-mix, non-optimized, standard RT-PCR conditions introduced artificial recombinants in a fraction of at least 30% of the reads that subsequently led to an underestimation of true haplotype frequencies. We minimized the fraction of recombinants down to 0.9-2.6% by optimized, artifact-reducing RT-PCR conditions. This approach enabled correct haplotype reconstruction and frequency estimations consistent with reference data obtained by single genome amplification. RT-PCR conditions are crucial for correct frequency estimation and analysis of haplotypes in heterogeneous virus populations. We developed an RT-PCR procedure to generate NGS data useful for reliable haplotype reconstruction and quantification.