31 resultados para Electricity generation performance test
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.
Resumo:
BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.
Resumo:
Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.
Resumo:
OBJECTIVE This study aimed to test the prediction from the Perception and Attention Deficit model of complex visual hallucinations (CVH) that impairments in visual attention and perception are key risk factors for complex hallucinations in eye disease and dementia. METHODS Two studies ran concurrently to investigate the relationship between CVH and impairments in perception (picture naming using the Graded Naming Test) and attention (Stroop task plus a novel Imagery task). The studies were in two populations-older patients with dementia (n = 28) and older people with eye disease (n = 50) with a shared control group (n = 37). The same methodology was used in both studies, and the North East Visual Hallucinations Inventory was used to identify CVH. RESULTS A reliable relationship was found for older patients with dementia between impaired perceptual and attentional performance and CVH. A reliable relationship was not found in the population of people with eye disease. CONCLUSIONS The results add to previous research that object perception and attentional deficits are associated with CVH in dementia, but that risk factors for CVH in eye disease are inconsistent, suggesting that dynamic rather than static impairments in attentional processes may be key in this population.
Resumo:
Contemporary models of self-regulated learning emphasize the role of distal motivational factors for student's achievement, on the one side, and the proximal role of metacognitive monitoring and control for learning and test outcomes, on the other side. In the present study, two larger samples of elementary school children (9- and 11-year-olds) were included and their mastery-oriented motivation, metacognitive monitoring and control skills were integrated into structural equation models testing and comparing the relative impact of these different constituents for self-regulated learning. For one, results indicate that the factorial structure of monitoring, control and mastery motivation was invariant across the two age groups. Of specific interest was the finding that there were age-dependent structural links between monitoring, control, and test performance (closer links in the older compared to the younger children), with high confidence yielding a direct and positive effect on test performance and a direct and negative effect on adequate control behavior in the achievement test. Mastery-oriented motivation was not found to be substantially associated with monitoring (confidence), control (detection and correction of errors), or test performance underlining the importance of proximal, metacognitive factors for test performance in elementary school children.
Resumo:
Colors have been found to affect psychological functioning. Empirical evidence suggests that, in test situations, brief perceptions of the color red or even the word "red" printed in black ink prime implicit anxious responses and consequently impair cognitive performance. However, we propose that this red effect depends on people's momentary capacity to exert control over their prepotent responses (i.e., self-control). In three experiments (Ns = 66, 78, and 130), first participants' self-control strength was manipulated. Participants were then primed with the color or word red versus gray prior to completing an arithmetic test or an intelligence test. As expected, self-control strength moderated the red effect. While red had a detrimental effect on performance of participants with depleted self-control strength (ego depletion), it did not affect performance of participants with intact self-control strength. We discuss implications of the present findings within the current debate on the robustness of priming results
Resumo:
This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.
Resumo:
The articular cartilage layer of synovial joints is commonly lesioned by trauma or by a degenerative joint disease. Attempts to repair the damage frequently involve the performance of autologous chondrocyte implantation (ACI). Healthy cartilage must be first removed from the joint, and then, on a separate occasion, following the isolation of the chondrocytes and their expansion in vitro, implanted within the lesion. The disadvantages of this therapeutic approach include the destruction of healthy cartilage-which may predispose the joint to osteoarthritic degeneration-the necessarily restricted availability of healthy tissue, the limited proliferative capacity of the donor cells-which declines with age-and the need for two surgical interventions. We postulated that it should be possible to induce synovial stem cells, which are characterized by high, age-independent, proliferative and chondrogenic differentiation capacities, to lay down cartilage within the outer juxtasynovial space after the transcutaneous implantation of a carrier bearing BMP-2 in a slow-release system. The chondrocytes could be isolated on-site and immediately used for ACI. To test this hypothesis, Chinchilla rabbits were used as an experimental model. A collagenous patch bearing BMP-2 in a slow-delivery vehicle was sutured to the inner face of the synovial membrane. The neoformed tissue was excised 5, 8, 11 and 14 days postimplantation for histological and histomorphometric analyses. Neoformed tissue was observed within the outer juxtasynovial space already on the 5th postimplantation day. It contained connective and adipose tissues, and a central nugget of growing cartilage. Between days 5 and 14, the absolute volume of cartilage increased, attaining a value of 12 mm(3) at the latter juncture. Bone was deposited in measurable quantities from the 11th day onwards, but owing to resorption, the net volume did not exceed 1.5 mm(3) (14th day). The findings confirm our hypothesis. The quantity of neoformed cartilage that is deposited after only 1 week within the outer juxtasynovial space would yield sufficient cells for ACI. Since the BMP-2-bearing patches would be implanted transcutaneously in humans, only one surgical or arthroscopic intervention would be called for. Moreover, most importantly, sufficient numbers of cells could be generated in patients of all ages.