OBJECTIVES: An optimized, longitudinal in vivo magnetic resonance vessel wall-imaging protocol was evaluated regarding its capability of detecting differences in the time-dependent atherosclerotic lesion progression in the aortic arch between ApoE(-/-) and double-deficient ApoE(-/-)/TNF(-/-) mice at comparatively early plaque development stages. MATERIALS AND METHODS: Seven ApoE(-/-) and seven ApoE(-/-)/TNF(-/-) female mice underwent MRI at 11.75 teslas at four stages up to 26 weeks of age. A double-gated spin-echo MRI sequence was used with careful perpendicular slice positioning to visualize the vessel wall of the ascending aortic arch. RESULTS: Wall-thickness progression measured with MRI was significant at 11 weeks of age in ApoE(-/-) mice, but only at 26 weeks in ApoE(-/-)/TNF(-/-) mice. A significant correlation was found between MRI wall-thickness and lesion area determined on histology. CONCLUSION: MRI was shown to be sensitive enough to reveal subtle genetically-induced differences in lesion progression at ages earlier than 25 weeks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Despite advances in surgical and interventional techniques, the optimal surgical treatment of severe aortic (re) coarctation and hypoplastic aortic arch is still controversial. Anatomic repair may require extensive dissection, cardiopulmonary bypass, and deep hypothermic circulatory arrest with their inherent risks. The aim of this study was to analyze the outcome of off-pump extraanatomic aortic bypass as a surgical alternative to local repair. METHODS: From February 2000 to December 2005, ten consecutive patients (median age 20 years; range, 11 to 38 years) with severe aortic (re) coarctation (n = 4) and (or) hypoplastic aortic arch (n = 7) underwent off-pump extraanatomic aortic bypass through median sternotomy. All but three patients had undergone previous surgery for coarctation and angioplasty or stenting. Three patients underwent concomitant replacement of the ascending aorta because of an aneurysm using cardiopulmonary bypass. RESULTS: Postoperative hospital course was uneventful in all patients. There was no perioperative mortality or significant morbidity. During a mean follow-up of 48 +/- 22 months no patient required additional procedures. All patients were free of symptoms; no patient showed signs of heart failure after follow-up. At last follow-up, no patient presented with claudication, nor any patient experienced orthostatic problems due to a steal phenomenon. During follow-up, hypertension resolved in all patients with residual mild hypertension in two patients. CONCLUSIONS: Off-pump extraanatomic aortic bypass is an attractive treatment option for complex aortic (re) coarctation and hypoplastic aortic arch. Perioperative risks are minimized, hypertension is influenced favorably, and midterm survival is event-free.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Several technical advances in thoracic aortic surgery, such as the use of antegrade cerebral perfusion, avoidance of cross-clamping and the application of glue, have beneficially influenced postoperative outcome. The aim of the present study was to analyse the impact of these developments on outcome of patients undergoing surgery of the thoracic aorta. METHODS AND RESULTS: Between January 1996 and December 2005, 835 patients (37.6%) out of 2215 aortic patients underwent surgery on the thoracic ascending aorta or the aortic arch at our institution. All in-hospital data were assessed. Two hundred and forty-one patients (28.8%) suffered from acute type A dissection (AADA). Overall aortic caseload increased from 41 patients in 1996 to 141 in 2005 (+339%). The increase was more pronounced for thoracic aortic aneurysms (TAA) (+367.9%), than for acute type A aortic dissections (+276.9%). Especially in TAA, combined procedures increased and the amount of patients with impaired left ventricular function (EF <50%) raised up from 14% in 1996 to 24% in 2005. Average age remained stable. Logistic regression curve revealed a significant decrease in mortality (AADA) and in the overall incidence of neurological deficits. CONCLUSIONS: Technical advances in the field of thoracic aortic surgery lead to a decrease of mortality and morbidity, especially in the incidence of adverse neurological events, in a large collective of patients. Long-term outcome and quality of life are better, since antegrade cerebral perfusion has been introduced.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: We have shown that selective antegrade cerebral perfusion improves mid-term quality of life in patients undergoing surgical repair for acute type A aortic dissection and aortic aneurysms. The aim of the study was to assess the impact of continuous cerebral perfusion through the right subclavian artery on immediate outcome and quality of life. METHODS: Perioperative data of 567 consecutive patients who underwent surgery of the aortic arch using deep hypothermic circulatory arrest have been analyzed. Patients were divided into three groups, according to the management of cerebral protection. Three hundred eighty-seven patients (68.3%) had deep hypothermic circulatory arrest with pharmacologic protection with pentothal only, 91 (16.0%) had selective antegrade cerebral perfusion and pentothal, and 89 (15.7%) had continuous cerebral perfusion through the right subclavian artery and pentothal. All in-hospital data were assessed, and quality of life was analyzed prospectively 2.4 +/- 1.2 years after surgery with the Short Form-36 Health Survey Questionnaire. RESULTS: Major perioperative cerebrovascular injuries were observed in 1.1% of the patients with continuous cerebral perfusion through the right subclavian artery, compared with 9.8% with selective antegrade cerebral perfusion (p < 0.001) and 6.5% in the group with no antegrade cerebral perfusion (p = 0.007). Average quality of life after an arrest time between 30 and 50 minutes with continuous cerebral perfusion through the right subclavian artery was significantly better than selective antegrade cerebral perfusion (90.2 +/- 12.1 versus 74.4 +/- 40.7; p = 0.015). CONCLUSIONS: Continuous cerebral perfusion through the right subclavian artery improves considerably perioperative brain protection during deep hypothermic circulatory arrest. Irreversible perioperative neurologic complications can be significantly reduced and duration of deep hypothermic circulatory arrest can be extended up to 50 minutes without impairment in quality of life.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A 49-year-old male patient presented with a paravalvular leakage 18 years after aortic valve replacement. The patient received a mechanical valve and was weaned uneventfully from cardiopulmonary bypass. After a drop in the pressure curve of the left radial artery an additional line was placed in the proximal ascending aorta showing normal systemic pressure. Transesophageal echocardiography showed a massive circular thrombosis of the distal aortic arch. The patient received a covered stent to expand the residual aortic lumen and left the hospital in good health.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Unilateral or bilateral axillary masses in children are often of clinical concern for malignancies. Our review illustrates a normal variant of the axilla mimicking clinically an axillary mass. Methods and Materials: Systematic review of our PACS and RIS with the keyword “axilla” and the modality “ultrasound” in children under 16 years of age from 1.12.2009 until 30.11.2012. 19 axillary ultrasound examinations in 16 patients (7m/9f, age 3 months to 15 years) were included. One patient was examined 2 and one patient 3 times. In 6 patients a prominent muscle was noted overlying the humeral head in an abducted position. The muscle diameter was measured in cm and compared with the contralateral side. In one patient photographs of the axilla were available. Results: In 16 examinations a lymphadenopathy (n=5), abscess formation (n=5), seroma or hematoma (n=1) or lymphangioma (n=1) and no diagnosis (n=1) was found. In 4 patients (25%) a unilateral muscle variant and in 2 patients a bilateral muscle variant (axillary arch muscle) was noted. In one patient a duplication of the muscle was found. In 4 patients the muscle was larger than the contralateral side. Conclusion: An axillary mass in children without other clinical complaints may be related to a normal variant, the axillary arch muscle. Ultrasound is the first modality of choice if imaging is required. Radiologists should be aware of this normal variant since no other workup is necessary in asymptomatic children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES To identify the timing of significant arch dimensional increases during orthodontic alignment involving round and rectangular nickel-titanium (NiTi) wires and rectangular stainless steel (SS). A secondary aim was to compare the timing of changes occurring with conventional and self-ligating fixed appliance systems. METHODS In this non-primary publication, additional data from a multicenter randomised trial initially involving 96 patients, aged 16 years and above, were analysed. The main pre-specified outcome measures were the magnitude and timing of maxillary intercanine, interpremolar, and intermolar dimensions. Each participant underwent alignment with a standard Damon (Ormco, Orange, CA) wire sequence for a minimum of 34 weeks. Blinding of clinicians and patients was not possible; however, outcome assessors and data analysts were kept blind to the appliance type during data analysis. RESULTS Complete data were obtained from 71 subjects. Significant arch dimensional changes were observed relatively early in treatment. In particular, changes in maxillary inter-first and second premolar dimensions occurred after alignment with an 0.014in. NiTi wire (P<0.05). No statistical differences in transverse dimensions were found between rectangular NiTi and working SS wires for each transverse dimension (P>0.05). Bracket type had no significant effect on the timing of the transverse dimensional changes. CONCLUSIONS Arch dimensional changes were found to occur relatively early in treatment, irrespective of the appliance type. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed. CLINICAL SIGNIFICANCE On the basis of this research orthodontic expansion may occur relatively early in treatment. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Images of the medieval past have long been fertile soil for the identity politics of subsequent periods. Rather than “authentically” reproducing the Middle Ages, medievalism therefore usually tells us more about the concerns and ideological climate of its own time and place of origin. To dramatise the nascent nation, Shakespeare resorts to medievalism in his history plays. Centuries later, the BBC-produced television mini-serial The Hollow Crown – adapting Shakespeare’s second histories tetralogy – revamps this negotiation of national identity for the “Cultural Olympiad” in the run-up to the 2012 London Olympics. In this context of celebratory introspection, The Hollow Crown weaves a genealogical narrative consisting of the increasingly “glorious” medieval history depicted and “national” Shakespearean heritage in order to valorise 21st-century “Britishness”. Encouraging a reading of the histories as medieval history, the films construct an ostensibly inclusive, liberal-minded national identity grounded in this history. Moreover, medieval kingship is represented in distinctly sentimentalising and humanising terms, fostering emotional identification especially with the no longer ambivalent Hal/Henry V and making him an apt model for present-day British grandeur. However, the fact that the films in return marginalise female, Scottish, Irish and Welsh characters gives rise to doubts as to whether this vision of Shakespeare’s Middle Ages really is, as the producers claimed, “for everybody”.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies. Description A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm. Evaluation This model was very helpful for the preoperative decision making and planning of the frozen elephant trunk procedure owing to the exact and lifelike illustration of the native aortic arch. Conclusions Three-dimensional models are helpful in preoperative planning and postoperative evaluation of frozen elephant trunk procedures in patients with complex aortic anatomy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier.