286 resultados para atrial fibrillation ablation
Resumo:
For patients with extensive bilobar colorectal liver metastases (CRLM), initial surgery may not be feasible and a multimodal approach including microwave ablation (MWA) provides the only chance for prolonged survival. Intraoperative navigation systems may improve the accuracy of ablation and surgical resection of so-called "vanishing lesions", ultimately improving patient outcome. Clinical application of intraoperative navigated liver surgery is illustrated in a patient undergoing combined resection/MWA for multiple, synchronous, bilobar CRLM. Regular follow-up with computed tomography (CT) allowed for temporal development of the ablation zones. Of the ten lesions detected in a preoperative CT scan, the largest lesion was resected and the others were ablated using an intraoperative navigation system. Twelve months post-surgery a new lesion (Seg IVa) was detected and treated by trans-arterial embolization. Nineteen months post-surgery new liver and lung metastases were detected and a palliative chemotherapy started. The patient passed away four years after initial diagnosis. For patients with extensive CRLM not treatable by standard surgery, navigated MWA/resection may provide excellent tumor control, improving longer-term survival. Intraoperative navigation systems provide precise, real-time information to the surgeon, aiding the decision-making process and substantially improving the accuracy of both ablation and resection. Regular follow-ups including 3D modeling allow for early discrimination between ablation zones and recurrent tumor lesions.
Resumo:
High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.
Resumo:
Background Catheter ablation (CA) of ventricular tachycardia (VT) is an important treatment option in patients with structural heart disease (SHD) and implantable cardioverter defibrillator (ICD). A subset of patients requires epicardial CA for VT. Objective The purpose of the study was to assess the significance of epicardial CA in these patients after a systematic sequential endocardial approach. Methods Between January 2009 and October 2012 CA for VT was analyzed. A sequential CA approach guided by earliest ventricular activation, pacemap, entrainment and stimulus to QRS-interval analysis was used. Acute CA success was assessed by programmed ventricular stimulation. ICD interrogation and 24 h-Holter ECG were used to evaluate long-term success. Results One hundred sixty VT ablation procedures in 126 consecutive patients (114 men; age 65 ± 12 years) were performed. Endocardial CA succeeded in 250 (94%) out of 265 treated VT. For 15 (6%) VT an additional epicardial CA was performed and succeeded in 9 of these 15 VT. Long-term FU (25 ± 18.2 month) showed freedom of VT in 104 pts (82%) after 1.2 ± 0.5 procedures, 11 (9%) suffered from repeated ICD shocks and 11 (9%) died due to worsening of heart failure. Conclusions Despite a heterogenic substrate for VT in SHD, endocardial CA alone results in high acute success rates. In this study additional epicardial CA following a sequential endocardial mapping and CA approach was performed in 6% of VT. Thus, due to possible complications epicardial CA should only be considered if endocardial CA fails.
Resumo:
Laser ablation/ionisation mass spectrometry with a vertical resolution at a nanometre scale was applied for the quantitative characterisation of the chemical composition of additive-assisted Cu electroplated deposits used in the microchip industry. The detailed chemical analysis complements information gathered by optical techniques and allows new insights into the metal deposition process.
Resumo:
Atrial septal defects (ASDs) are one of the most frequent congenital cardiac malformations, accounting for about 8-10% of all congenital heart defects. The prevalence of pulmonary arterial hypertension (PAH) in adults with an ASD is 8-10%. Different clinical PAH scenarios can be encountered. At one end of the spectrum are adults with no or only mild pulmonary vascular disease and a large shunt. These are patients who can safely undergo shunt closure. In the elderly, mild residual pulmonary hypertension after shunt closure is the rule. At the other end of the spectrum are adults with severe, irreversible pulmonary vascular disease, shunt reversal and chronic cyanosis, that is, Eisenmenger syndrome. These are patients who need to be managed medically. The challenge is to properly classify ASD patients with PAH falling in between the two ends of the spectrum as the ones with advanced, but reversible pulmonary vascular disease amenable to repair, versus the ones with progressive pulmonary vascular disease not responding to shunt closure. There are concerns that adults with progressive pulmonary vascular disease have worse outcomes after shunt closure than patients not undergoing shunt closure. Due to the correlation of pulmonary vascular changes and pulmonary hemodynamics, cardiac catheterization is used in the decision-making process. It is important to consider the hemodynamic data in the context of the clinical picture, the defect anatomy and further noninvasive tests when evaluating the option of shunt closure in these patients.
Resumo:
OBJECTIVE To evaluate differences in bacterial numbers, identity, and susceptibility in samples obtained from the tympanic cavity on entry (preflush) and after evacuation and lavage (postflush) and assess perioperative and empiric antimicrobial selection in dogs that underwent total ear canal ablation (TECA) with lateral bulla osteotomy (LBO) or reoperation LBO. DESIGN Prospective clinical study. ANIMALS 34 dogs. PROCEDURE TECA with LBO or reoperation LBO was performed on 47 ears. Pre- and postflush aerobic and anaerobic samples were obtained from the tympanic cavity. Isolates and antimicrobial susceptibility patterns were compared. RESULTS Different isolates (31/44 [70%] ears) and susceptibility patterns of isolate pairs (6/44 [14%] ears) were detected in pre- and postflush samples from 84% of ears. Evacuation and lavage of the tympanic cavity decreased the number of bacterial isolates by 33%. In 26% of ears, bacteria were isolated from post-flush samples but not preflush samples. Only 26% of isolates tested were susceptible to cefazolin. At least 1 isolate from 53% of dogs that received empirically chosen antimicrobials postoperatively was resistant to the selected drugs. Anaerobic bacteria were recovered from 6 ears. CONCLUSIONS AND CLINICAL RELEVANCE Accurate microbiologic assessment of the tympanic cavity should be the basis for selection of antimicrobials in dogs undergoing TECA with LBO. Bacteria remain in the tympanic cavity after evacuation and lavage. Cefazolin was a poor choice for dogs that underwent TECA with LBO, as judged on the basis of culture and susceptibility testing results.
Resumo:
BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.
Resumo:
Detection of extraterrestrial life is an ongoing goal in space exploration, and there is a need for advanced instruments and methods for the detection of signatures of life based on chemical and isotopic composition. Here, we present the first investigation of chemical composition of putative microfossils in natural samples using a miniature laser ablation/ionization time-of-flight mass spectrometer (LMS). The studies were conducted with high lateral (similar to 15 mu m) and vertical (similar to 20-200 nm) resolution. The primary aim of the study was to investigate the instrument performance on micrometer-sized samples both in terms of isotope abundance and element composition. The following objectives had to be achieved: (1) Consider the detection and calculation of single stable isotope ratios in natural rock samples with techniques compatible with their employment of space instrumentation for biomarker detection in future planetary missions. (2) Achieve a highly accurate chemical compositional map of rock samples with embedded structures at the micrometer scale in which the rock matrix is easily distinguished from the micrometer structures. Our results indicate that chemical mapping of strongly heterogeneous rock samples can be obtained with a high accuracy, whereas the requirements for isotope ratios need to be improved to reach sufficiently large signal-to-noise ratio (SNR). Key Words: Biogenicity-Biomarkers-Biosignatures-Filaments-Fossilization. Astrobiology 15, 669-682.