349 resultados para Aortic Coarctation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a widely accepted alternative to surgical aortic valve replacement (SAVR) among non-operable patients or selected high-risk patients with degenerative, severe aortic stenosis. TAVI is considered less invasive when compared with SAVR; however, there remain significant differences between different TAVI access routes. The transfemoral approach is considered the least invasive access route, and can be performed as a fully percutaneous procedure in a spontaneously breathing patient under local anaesthesia and mild sedation only. Moreover, transfemoral TAVI patients are typically transferred to coronary care rather than to an intensive care unit after the procedure, and benefit from early ambulation and a reduction in overall length of hospital stay. Considering these patient-specific and health-economic advantages, several TAVI centres follow the least invasive strategy for their patients and have implemented the transfemoral access route as the default access in their institutions. This article provides an overview on the prerequisites for a successful transfemoral TAVI procedure, describes the procedural advantages compared to alternative access routes, and highlights differences in clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present postmortem computed tomography (pmCT) as well as postmortem magnetic resonance (pmMR) imaging findings in a case of type II DeBakey aortic dissection with a complete rupture of the ascending aorta compared to the findings obtained at forensic autopsy. PmCT only allowed a presumptive diagnosis of aortic dissection based on an anterior mediastinal enlargement. However, at pmMR the dissection including the aortic rupture was clearly visible. Visualization was realized in an unenhanced manner without the need for postmortem angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of an 84-year-old male presenting with syncope and dynamic ST-T wave changes due to decompensated severe valvular aortic stenosis undergoing successful emergency transcatheter aortic valve implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM The aim of this study was to evaluate whether coronary artery disease (CAD) severity exerts a gradient of risk in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS A total of 445 patients with severe AS undergoing TAVI were included into a prospective registry between 2007 and 2012. The preoperative SYNTAX score (SS) was determined from baseline coronary angiograms. In case of revascularization prior to TAVI, residual SS (rSS) was also determined. Clinical outcomes were compared between patients without CAD (n = 158), patients with low SS (0-22, n = 207), and patients with high SS (SS >22, n = 80). The pre-specified primary endpoint was the composite of cardiovascular death, stroke, or myocardial infarction (MI). At 1 year, CAD severity was associated with higher rates of the primary endpoint (no CAD: 12.5%, low SS: 16.1%, high SS: 29.6%; P = 0.016). This was driven by differences in cardiovascular mortality (no CAD: 8.6%, low SS: 13.6%, high SS: 20.4%; P = 0.029), whereas the risk of stroke (no CAD: 5.1%, low SS: 3.3%, high SS: 6.7%; P = 0.79) and MI (no CAD: 1.5%, low SS: 1.1%, high SS: 4.0%; P = 0.54) was similar across the three groups. Patients with high SS received less complete revascularization as indicated by a higher rSS (21.2 ± 12.0 vs. 4.0 ± 4.4, P < 0.001) compared with patients with low SS. High rSS tertile (>14) was associated with higher rates of the primary endpoint at 1 year (no CAD: 12.5%, low rSS: 16.5%, high rSS: 26.3%, P = 0.043). CONCLUSIONS Severity of CAD appears to be associated with impaired clinical outcomes at 1 year after TAVI. Patients with SS >22 receive less complete revascularization and have a higher risk of cardiovascular death, stroke, or MI than patients without CAD or low SS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Endovascular therapy is a rapidly expanding option for the treatment of patients with aortic dissection (AD) and various studies have been published. These trials, however, are often difficult to interpret and compare because they do not utilize uniform clinical endpoint definitions. METHODS The DEFINE Group is a collaborative effort of an ad hoc multidisciplinary team from various specialties involved in AD therapy in Europe and the United States. DEFINE's goal was to arrive at a broad based consensus for baseline and endpoint definitions in trials for endovascular therapy of various vascular pathologies. In this project, which started in December 2006, the individual team members reviewed the existing pertinent literature. Following this, a series of telephone conferences and face-to-face meetings were held to agree upon definitions. Input was also obtained from regulatory (United States Food and Drug Administration) and industry (device manufacturers with an interest in peripheral endovascular revascularization) stakeholders, respectively. RESULTS These efforts resulted in the present document containing proposed baseline and endpoint definitions for clinical and morphological outcomes. Although the consensus has inevitably included certain arbitrary consensus choices and compromises, adherence to these proposed standard definitions would provide consistency across future trials, thereby facilitating evaluation of clinical effectiveness and safety of various endovascular revascularization techniques. CONCLUSIONS This current document is based on a broad based consensus involving relevant stakeholders from the medical community, industry and regulatory bodies. It is proposed that the consensus document may have value for study design of future clinical trials in endovascular AD therapy as well as for regulatory purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. Methods and results: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm2) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). Conclusions: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conservative medical treatment is commonly first recommended for patients with uncomplicated Type-B aortic dissection (AD). However, if dissection-related complications occur, endovascular repair or open surgery is performed. Here we establish computational models of AD based on radiological three-dimensional images of a patient at initial presentation and after 4-years of best medical treatment (BMT). Computational fluid dynamics analyses are performed to quantitatively investigate the hemodynamic features of AD. Entry and re-entries (functioning as entries and outlets) are identified in the initial and follow-up models, and obvious variations of the inter-luminal flow exchange are revealed. Computational studies indicate that the reduction of blood pressure in BMT patients lowers pressure and wall shear stress in the thoracic aorta in general, and flattens the pressure distribution on the outer wall of the dissection, potentially reducing the progressive enlargement of the false lumen. Finally, scenario studies of endovascular aortic repair are conducted. The results indicate that, for patients with multiple tears, stent-grafts occluding all re-entries would be required to effectively reduce inter-luminal blood communication and thus induce thrombosis in the false lumen. This implicates that computational flow analyses may identify entries and relevant re-entries between true and false lumen and potentially assist in stent-graft planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.