255 resultados para fractures fixation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. STUDY DESIGN: Retrospective CT imaging study. SAMPLE POPULATION: Cervical CT scans of toy breed dogs (n = 21). METHODS: Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. RESULTS: Mean +/- SD optimal transarticular atlantoaxial insertion angle was determined to be 40 +/- 1 degrees in medial to lateral direction from the midline and 20 +/- 1 degrees in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. CONCLUSIONS: Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To biomechanically test the properties of three different Universal Micro External Fixator (UMEX™) configurations with regard to their use in very small animals (<5kg) and compare the UMEX system to the widely used IMEX External Skeletal Fixation (SK™) system in terms of stiffness, space needed for pin placement and weight. METHODS Three different UMEX configurations (type Ia, type Ib, and type II modified) and one SK configuration type Ia were used to stabilize Delrin plastic rods in a 1 cm fracture gap model. These constructs were tested in axial compression, craniocaudal bending, mediolateral bending, and torsion. Testing was conducted within the elastic range and mean stiffness in each mode was determined from the slope of the linear portion of the load-deformation curve. A Kruskal Wallis one-way analysis of variance on ranks test was utilized to assess differences between constructs (p <0.05). RESULTS The UMEX type II modified configuration was significantly stiffer than the other UMEX configurations and the SK type Ia, except in craniocaudal bending, where the SK type Ia configuration was stiffer than all UMEX constructs. The UMEX type Ia configuration was significantly the weakest of those frames. The UMEX constructs were lighter and smaller than the SK, thus facilitating closer pin placement. CONCLUSIONS Results supported previous reports concerning the superiority of more complex constructs regarding stiffness. The UMEX system appears to be a valid alternative for the treatment of long-bone fractures in very small animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors tested an autoclavable external ring retractor, fixed to the operation table, for the endoscopic reconstruction of anterior column injuries of the thoracolumbar junction. It served as a retractor for the diaphragm, and offered a stable support for the scope and other instruments, making an assistant superfluous. Moreover, it allowed bimanual manipulation. Of course, the two-dimensional image, provided by the scope, necessitated proper eye-hand coordination. Twenty-eight consecutive patients underwent either a monosegmental (n = 10) or a bisegmental (n = 18) anterior stabilization in the area Th11L1. Three portals were necessary, but an assistant was not needed. The overall (mean +/- SD) operating time was 196 +/- 56 min, the blood loss was 804 +/- 719 mL. Intraoperatively, one epidural bleeding and a single screw cut-out occurred. All complications were managed endoscopically. Postoperatively, evacuation of a haemothorax (n = 1) was necessary. In all patients, wounds and fractures healed uneventfully. The combination of the endoscopic technique and the retractor system was feasible, successful, safe, and time efficient. Moreover, it allowed for anterior instrumentation of thoracolumbar fractures by a single surgeon. It became the standard approach in the authors' department.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the difference between a 5-day and a 1-day postoperative course of antibiotic on the incidence of infection after mandibular fractures involving the alveolus. Sixty-two patients with fractures of the mandible involving the dentoalveolar region were randomly assigned to 2 groups, both of which were given amoxicillin/clavulanic acid 1.2 g intravenously every 8 h from admission until 24 h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625 mg orally every 8 h for another 4 days. The 1-day group was given an oral placebo at the same intervals. Follow-up appointments were 1, 2, 4, 6, 12 weeks and 6 months postoperatively. Development of an infection was the primary end point. Fifty-nine of the 62 patients completed this study. Six of the 30 patients in the 5-day group (20%) and 6 out of the 29 in the 1-day group (21%) developed local wound infections. Three of the 6 in the 1-day group developed purulent discharge and swelling. One patient in the 5-day group developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. In fractures of the mandible involving the alveolus, a 1-day postoperative course of antibiotic is as effective in preventing infective complications as a 5-day regimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The goal of this study was to evaluate the influence of the duration of postoperative antibiotics (1 day vs. ≥ 5 days) on wound infections following surgical treatment of facial fractures. METHODS Three hundred thirty-nine patient case histories with a total of 498 fractures were reviewed retrospectively with regard to infections occurring within a 6-month period following surgical management. Patients were divided into two groups based on the duration of postoperative antibiotics administered. Group A consisted of 125 patients who had 1 day of postoperative antibiotics, whereas Group B consisted of 214 patients who had five or more days of postoperative antibiotics. Statistical analysis was conducted to assess for possible differences in the rate of postoperative infections. RESULTS Five patients in Group A (4%) and seven patients in Group B (3.27%) developed infections within the follow-up period. Of these 12 patients, seven had sustained multiple facial bone fractures. Eleven infections occurred in patients with mandibular fractures and one in a midfacial fracture. Statistical analysis using Fisher's exact test showed no significant difference (p = 0.77) in the incidence of infection between Groups A and B. CONCLUSION In this retrospective study, the use of prolonged postoperative antibiotics in uncomplicated mandibular and midfacial fractures had no significant benefit in reducing the incidence of infections. LEVEL OF EVIDENCE Therapeutic study, level IV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the sensitivity of postmortem computed tomography (PMCT) in rib fracture detection validated against autopsy. Fifty-one forensic cases underwent a postmortem CT prior to forensic autopsy. Two image readers (radiologist and forensic pathologist) assessed high resolution CT data sets for rib fractures. Correct recognition rates (CRR), sensitivity and specificity values were calculated over all observations as well as individually for every rib and region. Additionally, for partial rib fractures the sensitivity of autopsy was calculated vice versa. 3876 entries in each study protocol (autopsy, PMCT radiologist and PMCT forensic pathologist) were investigated. A total of 690 fractures (autopsy), 491 (PMCT and radiologist) and 559 (PMCT and forensic pathologist) were detected. The CRR was 0.85. Sensitivity and specificity of PMCT for rib fracture detection were 0.63 (0.58 radiologist, 0.68 forensic pathologist) and 0.97 (both readers 0.97), respectively. Low CRR and sensitivity values were obtained for antero-lateral fractures. Partial rib fractures were better detected by PMCT. PMCT has a rather low sensitivity for rib fracture detection when validated against autopsy and indicates that clinical CT may also demonstrate a reasonable number of false negatives. Partial rib fractures often remain undetected at autopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scaphoid is the most frequently fractured carpal bone. When investigating fixation stability, which may influence healing, knowledge of forces and moments acting on the scaphoid is essential. The aim of this study was to evaluate cartilage contact forces acting on the intact scaphoid in various functional wrist positions using finite element modeling. A novel methodology was utilized as an attempt to overcome some limitations of earlier studies, namely, relatively coarse imaging resolution to assess geometry, assumption of idealized cartilage thicknesses and neglected cartilage pre-stresses in the unloaded joint. Carpal bone positions and articular cartilage geometry were obtained independently by means of high resolution CT imaging and incorporated into finite element (FE) models of the human wrist in eight functional positions. Displacement driven FE analyses were used to resolve inter-penetration of cartilage layers, and provided contact areas, forces and pressure distribution for the scaphoid bone. The results were in the range reported by previous studies. Novel findings of this study were: (i) cartilage thickness was found to be heterogeneous for each bone and vary considerably between carpal bones; (ii) this heterogeneity largely influenced the FE results and (iii) the forces acting on the scaphoid in the unloaded wrist were found to be significant. As major limitations, accuracy of the method was found to be relatively low, and the results could not be compared to independent experiments. The obtained results will be used in a following study to evaluate existing and recently developed screws used to fix scaphoid fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT The Swiss Federal Office of Public Health mandated a nationwide health technology assessment-registry for balloon kyphoplasty (BKP) for decision making on reimbursement of these interventions. The early results of the registry led to a permanent coverage of BKP by basic health insurance. The documentation was continued for further evidence generation. PURPOSE This analysis reports on the 1 year results of patients after BKP treatment. STUDY DESIGN Prospective multicenter observational case series. PATIENT SAMPLE The data on 625 cases with 819 treated vertebrae were documented from March 2005 to May 2012. OUTCOME MEASURES Surgeon-administered outcome instruments were primary intervention form for BKP and the follow-up form; patient self-reported measures were EuroQol-5D questionnaire, North American Spine Society outcome instrument /Core Outcome Measures Index (including visual analog scale), and a comorbidity questionnaire. Outcome measures were back pain, medication, quality of life (QoL), cement extrusions, and new fractures within the first postoperative year. METHODS Data were recorded preoperatively and at 3 to 6-month and 1-year follow-ups. Wilcoxon signed-rank test was used for comparison of pre- with postoperative measurements. Multivariate logistic regression was used to identify factors with a significant influence on the outcome. RESULTS Seventy percent of patients were women with mean age of 71 years (range, 18-91 years); mean age of men was 65 years (range, 15-93 years). Significant and clinically relevant reduction of back pain, improvement of QoL, and reduction of pain killer consumption was seen within the first postoperative year. Preoperative back pain decreased from 69.3 to 29.0 at 3 to 6-month and remained unchanged at 1-year follow-ups. Consequently, QoL improved from 0.23 to 0.71 and 0.75 at the same follow-up intervals. The overall vertebra-based cement extrusion rates with and without extrusions into intervertebral discs were 22.1% and 15.3%, respectively. Symptomatic cement extrusions with radiculopathy were five (0.8%). A new vertebral fracture within a year from the BKP surgery was observed in 18.4% of the patients. CONCLUSIONS The results of the largest observational study for BKP so far are consistent with published randomized trials and systematic reviews. In this routine health care setting, BKP is safe and effective in reducing pain, improving QoL, and lowering pain_killer consumption and has an acceptable rate of cement extrusions. Postoperative outcome results show clear and significant clinical improvement at early follow-up that remain stable during the first postoperative year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Our knowledge of factors influencing mortality of patients with pelvic ring injuries and the impact of associated injuries is currently based on limited information. Questions/purposes Weidentified the (1) causes and time of death, (2) demography, and (3) pattern and severity of injuries in patients with pelvic ring fractures who did not survive. Methods We prospectively collected data on 5340 patients listed in the German Pelvic Trauma Registry between April 30, 2004 and July 29, 2011; 3034 of 5340 (57%) patientswere female. Demographic data and parameters indicating the type and severity of injury were recorded for patients who died in hospital (nonsurvivors) and compared with data of patients who survived (survivors). The median followup was 13 days (range, 0–1117 days). Results A total of 238 (4%) patients died a median of 2 days after trauma. The main cause of death was massive bleeding (34%), predominantly from the pelvic region (62% of all patients who died because of massive bleeding). Fifty six percent of nonsurvivors and 43% of survivors were male. Nonsurvivors were characterized by a higher incidence of complex pelvic injuries (32% versus 8%), less isolated pelvic ring fractures (13% versus 49%), lower initial blood hemoglobin concentration (6.7 ± 2.9 versus 9.8 ± 3.0 g/dL) and systolic arterial blood pressure (77 ± 27 versus 106 ± 24 mmHg), and higher injury severity score (ISS) (35 ± 16 versus 15 ± 12). Conclusion Patients with pelvic fractures who did not survive were characterized by male gender, severe multiple trauma, and major hemorrhage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND In postmenopausal women, yearly intravenous zoledronate (ZOL) compared to placebo (PLB) significantly increased bone mineral density (BMD) at lumbar spine (LS), femoral neck (FN), and total hip (TH) and decreased fracture risk. The effects of ZOL on BMD at the tibial epiphysis (T-EPI) and diaphysis (T-DIA) are unknown. METHODS A randomized controlled ancillary study of the HORIZON trial was conducted at the Department of Osteoporosis of the University Hospital of Berne, Switzerland. Women with ≥1 follow-up DXA measurement who had received ≥1 dose of either ZOL (n=55) or PLB (n=55) were included. BMD was measured at LS, FN, TH, T-EPI, and T-DIA at baseline, 6, 12, 24, and 36 months. Morphometric vertebral fractures were assessed. Incident clinical fractures were recorded as adverse events. RESULTS Baseline characteristics were comparable with those in HORIZON and between groups. After 36 months, BMD was significantly higher in women treated with ZOL vs. PLB at LS, FN, TH, and T-EPI (+7.6%, +3.7%, +5.6%, and +5.5%, respectively, p<0.01 for all) but not T-DIA (+1.1%). The number of patients with ≥1 incident non-vertebral or morphometric fracture did not differ between groups (9 ZOL/11 PLB). Mean changes in BMD did not differ between groups with and without incident fracture, except that women with an incident non-vertebral fracture had significantly higher bone loss at predominantly cortical T-DIA (p=0.005). CONCLUSION ZOL was significantly superior to PLB at T-EPI but not at T-DIA. Women with an incident non-vertebral fracture experienced bone loss at T-DIA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence suggests a strong relation between superior motor performance and the duration of the last fixation before movement initiation (called Quiet Eye, QE). Although this phenomenon proves to be quite robust, to date, only little is known about its functional role. Therefore, in two experiments, a novel paradigm is introduced, testing the QE as independent variable by experimentally manipulating the duration of the last fixation in a throwing task. In addition, this paradigm allowed for the manipulation of the predictability of the target position. Results of the first study revealed an increase in throwing accuracy as function of experimentally prolonged QE durations. Thus, the assumption that the QE does not surface as a mere by-product of superior performance could be confirmed. In the second study, this dependency was found only under high task-demand conditions in which the target position was not predictable. This finding confirms the hypothesis that it is the optimization of information processing which serves as the crucial mechanisms behind QE effects.