272 resultados para Ventricular Fibrillation
Resumo:
Stroke in patients with atrial fibrillation (AF) is often associated with substantial morbidity and mortality. Oral anticoagulation remains the first-line approach to stroke prevention in such individuals; however, for a considerable proportion of patients, traditional treatment using warfarin is limited by a number of factors, such as the inconvenience of frequent therapeutic monitoring and the risk of haemorrhage. The development of new oral anticoagulants with improved efficacy and safety profiles has provided viable options for oral anticoagulation therapy in patients with nonvalvular (nonrheumatic AF). Nonetheless, in patients who have an increased risk of major haemorrhage, a nonpharmacological approach to antithrombotic therapy remains an attractive alternative. The left atrial appendage (LAA) has been found to be the source of >90% of thrombi in patients with nonvalvular AF; thus, prevention of thrombus formation via transcatheter mechanical LAA occlusion is a novel therapeutic target for stroke prevention in this patient population. In this Review, we present the rationale for LAA occlusion in patients with AF, the available occlusion devices and their clinical evidence to date. We also discuss the roles of various imaging techniques in device implantation and the management strategy for associated procedural complications.
Resumo:
BACKGROUND Ventricular torsion is an important component of cardiac function. The effect of septic shock on left ventricular torsion is not known. Because torsion is influenced by changes in preload, we compared the effect of fluid loading on left ventricular torsion in septic shock with the response in matched healthy control subjects. METHODS We assessed left ventricular torsion parameters using transthoracic echocardiography in 11 patients during early septic shock and in 11 age- and sex-matched healthy volunteers before and after rapid volume loading with 250 mL of a Ringer's lactate solution. RESULTS Peak torsion and peak apical rotation were reduced in septic shock (10.2 ± 5.2° and 5.6 ± 5.4°) compared with healthy volunteers (16.3 ± 4.5° and 9.6 ± 1.5°; P = 0.009 and P = 0.006 respectively). Basal rotation was delayed and diastolic untwisting velocity reached its maximum later during diastole in septic shock patients than in healthy volunteers (104 ± 16% vs 111 ± 14% and 13 ± 5% vs 21 ± 10%; P = 0.03 and P = 0.034, respectively). Fluid challenge increased peak torsion in both groups (septic shock, 10.2 ± 5.3° vs 12.6 ± 3.9°; healthy volunteers, 16.3 ± 4.5° vs 18.1 ± 6°; P = 0.01). Fluid challenge increased left ventricular stroke volume in septic shock patients (P = 0.003). CONCLUSIONS Compared with healthy volunteers, left ventricular torsion is impaired in septic shock patients. Fluid loading attenuates torsion abnormalities in parallel with increasing stroke volume. Reduced torsional motion might constitute a relevant component of septic cardiomyopathy, a notion that merits further testing in larger populations.
Resumo:
Atrial fibrillation (AF) is associated with an increased risk of thromboembolism, and is the most prevalent factor for cardioembolic stroke. Vitamin K antagonists (VKAs) have been the standard of care for stroke prevention in patients with AF since the early 1990s. They are very effective for the prevention of cardioembolic stroke, but are limited by factors such as drug-drug interactions, food interactions, slow onset and offset of action, haemorrhage and need for routine anticoagulation monitoring to maintain a therapeutic international normalised ratio (INR). Multiple new oral anticoagulants have been developed as potential replacements for VKAs for stroke prevention in AF. Most are small synthetic molecules that target thrombin (e.g. dabigatran etexilate) or factor Xa (e.g. rivaroxaban, apixaban, edoxaban, betrixaban, YM150). These drugs have predictable pharmacokinetics that allow fixed dosing without routine laboratory monitoring. Dabigatran etexilate, the first of these new oral anticoagulants to be approved by the United States Food and Drug Administration and the European Medicines Agency for stroke prevention in patients with non-valvular AF, represents an effective and safe alternative to VKAs. Under the auspices of the Regional Anticoagulation Working Group, a multidisciplinary group of experts in thrombosis and haemostasis from Central and Eastern Europe, an expert panel with expertise in AF convened to discuss practical, clinically important issues related to the long-term use of dabigatran for stroke prevention in non-valvular AF. The practical information reviewed in this article will help clinicians make appropriate use of this new therapeutic option in daily clinical practice.
Resumo:
Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.
Resumo:
BACKGROUND The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. METHODS This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20-29, 30-49, 50-69, and ≥70 years) and cardiac measurements were compared using Pearson's rank correlation over the four different groups. RESULTS With advanced age a slight but significant decrease in ESV (r=-0.41 for both ventricles, P<0.001) and EDV (r=-0.39 for left ventricle, r=-0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). CONCLUSIONS The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies.
Resumo:
Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.
Resumo:
The cyclic peptide Melanin Concentrating Hormone (MCH) is known to control a large number of brain functions in mammals such as food intake and metabolism, stress response, anxiety, sleep/wake cycle, memory, and reward. Based on neuro-anatomical and electrophysiological studies these functions were attributed to neuronal circuits expressing MCHR1, the single MCH receptor in rodents. In complement to our recently published work (1) we provided here new data regarding the action of MCH on ependymocytes in the mouse brain. First, we establish that MCHR1 mRNA is expressed in the ependymal cells of the third ventricle epithelium. Second, we demonstrated a tonic control of MCH-expressing neurons on ependymal cilia beat frequency using in vitro optogenics. Finally, we performed in vivo measurements of CSF flow using fluorescent micro-beads in wild-type and MCHR1-knockout mice. Collectively, our results demonstrated that MCH-expressing neurons modulate ciliary beating of ependymal cells at the third ventricle and could contribute to maintain cerebro-spinal fluid homeostasis.
Resumo:
Ependymal cell cilia help move cerebrospinal fluid through the cerebral ventricles, but the regulation of their beat frequency remains unclear. Using in vitro, high-speed video microscopy and in vivo magnetic resonance imaging in mice, we found that the metabolic peptide melanin-concentrating hormone (MCH) positively controlled cilia beat frequency, specifically in the ventral third ventricle, whereas a lack of MCH receptor provoked a ventricular size increase.
Resumo:
OBJECTIVES This study sought to identify nonredundant atrial fibrillation (AF) genetic susceptibility signals and examine their cumulative relations with AF risk. BACKGROUND AF-associated loci span broad genomic regions that may contain multiple susceptibility signals. Whether multiple signals exist at AF loci has not been systematically explored. METHODS We performed association testing conditioned on the most significant, independently associated genetic markers at 9 established AF loci using 2 complementary techniques in 64,683 individuals of European ancestry (3,869 incident and 3,302 prevalent AF cases). Genetic risk scores were created and tested for association with AF in Europeans and an independent sample of 11,309 individuals of Japanese ancestry (7,916 prevalent AF cases). RESULTS We observed at least 4 distinct AF susceptibility signals on chromosome 4q25 upstream of PITX2, but not at the remaining 8 AF loci. A multilocus score comprised 12 genetic markers demonstrated an estimated 5-fold gradient in AF risk. We observed a similar spectrum of risk associated with these markers in Japanese. Regions containing AF signals on chromosome 4q25 displayed a greater degree of evolutionary conservation than the remainder of the locus, suggesting that they may tag regulatory elements. CONCLUSIONS The chromosome 4q25 AF locus is architecturally complex and harbors at least 4 AF susceptibility signals in individuals of European ancestry. Similar polygenic AF susceptibility exists between Europeans and Japanese. Future work is necessary to identify causal variants, determine mechanisms by which associated loci predispose to AF, and explore whether AF susceptibility signals classify individuals at risk for AF and related morbidity.
Resumo:
Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.
Resumo:
AIM To assess the prevalence of vascular dementia, mixed dementia and Alzheimer's disease in patients with atrial fibrillation, and to evaluate the accuracy of the Hachinski ischemic score for these subtypes of dementia. METHODS A nested case-control study was carried out. A total of 103 of 784 consecutive patients evaluated for cognitive status at the Ambulatory Geriatric Clinic had a diagnosis of atrial fibrillation. Controls without atrial fibrillation were randomly selected from the remaining 681 patients using a 1:2 matching for sex, age and education. RESULTS The prevalence of vascular dementia was twofold in patients with atrial fibrillation compared with controls (21.4% vs 10.7%, P = 0.024). Alzheimer's disease was also more frequent in the group with atrial fibrillation (12.6% vs 7.3%, P = 0.046), whereas mixed dementia had a similar distribution. The Hachinski ischemic score poorly discriminated between dementia subtypes, with misclassification rates between 46% (95% CI 28-66) and 70% (95% CI 55-83). In patients with atrial fibrillation, these rates ranged from 55% (95% CI 32-77) to 69% (95% CI 39-91%). In patients in whom the diagnosis of dementia was excluded, the Hachinski ischemic score suggested the presence of vascular dementia in 11% and mixed dementia in 30%. CONCLUSIONS Vascular dementia and Alzheimer's disease, but not mixed dementia, are more prevalent in patients with atrial fibrillation. The discriminative accuracy of the Hachinski ischemic score for dementia subtypes in atrial fibrillation is poor, with a significant proportion of misclassifications.