199 resultados para spine segment stiffness
Resumo:
AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority <0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.
Resumo:
Atomic force microscopy (AFM) is a powerful imaging technique that allows recording topographical information of membrane proteins under near-physiological conditions. Remarkable results have been obtained on membrane proteins that were reconstituted into lipid bilayers. High-resolution AFM imaging of native disk membranes from vertebrate rod outer segments has unveiled the higher-order oligomeric state of the G protein-coupled receptor rhodopsin, which is highly expressed in disk membranes. Based on AFM imaging, it has been demonstrated that rhodopsin assembles in rows of dimers and paracrystals and that the rhodopsin dimer is the fundamental building block of higher-order structures.
Resumo:
BACKGROUND AND OBJECTIVES Despite the recommendations of national and international societies for the treatment of patients with acute neck and back pain, still too many radiologic examinations were performed. The purpose of this study was to analyze and optimize diagnostics and treatment of patients with acute back pain. METHODS The medical records of 484 patients presented to the emergency clinic with acute neck or back pain were analyzed for clinical history, physical examination, radiographic findings and therapy. RESULTS Radiographs of the lumbar, cervical, or thoracic spine were performed in 338 cases (70%). Radiographs were normal in 142 patients (42%) and degenerative changes were identified in 123 patients (36%). Only 2 patients (0.4%) had radiographic findings that had direct therapeutic relevance: 1 patient with metastatic disease and 1 patient with posttraumatic C1-C2 instability. For most patients without sensorimotor deficits and absent specific indications for radiography (“red flags”), therapy was not affected by the results of radiography. CONCLUSIONS Plain radiography of the spine was unnecessary in most patients initially evaluated with non-specific acute back pain and does not improve the clinical outcome. The implementation of national and international guidelines is a slow process, but helps to reduce costs and to protect patients from unnecessary ionizing radiation exposure.
Resumo:
OBJECTIVE To determine the biomechanical effect of an intervertebral spacer on construct stiffness in a PVC model and cadaveric canine cervical vertebral columns stabilized with monocortical screws/polymethylmethacrylate (PMMA). STUDY DESIGN Biomechanical study. SAMPLE POPULATION PVC pipe; cadaveric canine vertebral columns. METHODS PVC model-PVC pipe was used to create a gap model mimicking vertebral endplate orientation and disk space width of large-breed canine cervical vertebrae; 6 models had a 4-mm gap with no spacer (PVC group 1); 6 had a PVC pipe ring spacer filling the gap (PCV group 2). Animals-large breed cadaveric canine cervical vertebral columns (C2-C7) from skeletally mature dogs without (cadaveric group 1, n = 6, historical data) and with an intervertebral disk spacer (cadaveric group 2, n = 6) were used. All PVC models and cadaver specimens were instrumented with monocortical titanium screws/PMMA. Stiffness of the 2 PVC groups was compared in extension, flexion, and lateral bending using non-destructive 4-point bend testing. Stiffness testing in all 3 directions was performed of the unaltered C4-C5 vertebral motion unit in cadaveric spines and repeated after placement of an intervertebral cortical allograft ring and instrumentation. Data were compared using a linear mixed model approach that also incorporated data from previously tested spines with the same screw/PMMA construct but without disk spacer (cadaveric group 1). RESULTS Addition of a spacer increased construct stiffness in both the PVC model (P < .001) and cadaveric vertebral columns (P < .001) compared to fixation without a spacer. CONCLUSIONS Addition of an intervertebral spacer significantly increased construct stiffness of monocortical screw/PMMA fixation.
Resumo:
OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletally mature dogs (weighing 22-32 kg). METHODS Specimens were radiographed and examined by dual energy X-ray absorptiometry. Stiffness of the unaltered C4-C5 intervertebral motion unit was measured in extension, flexion and lateral bending using non-destructive 4-point bend testing. Specimens were then stabilized by (1) bicortical stainless steel pins/PMMA, (2) monocortical stainless steel screws/PMMA, or (3) monocortical titanium screws/PMMA. Mechanical testing was repeated and stiffness data from unaltered specimens and the 3 treatment groups were compared. RESULTS All 3 surgical methods significantly increased stiffness of the C4-C5 motion unit compared with the unaltered specimen (P < .001 for all treatments), but stiffness was not significantly different among the 3 fixation groups (P = .578). CONCLUSIONS In this model, monocortical screw fixation (with stainless steel or titanium screws) was biomechanically equivalent to bicortical fixation.
Resumo:
PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.
Resumo:
BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.
Resumo:
BACKGROUND The diagnostic performance of biochemical scores and artificial neural network models for portal hypertension and cirrhosis is not well established. AIMS To assess diagnostic accuracy of six serum scores, artificial neural networks and liver stiffness measured by transient elastography, for diagnosing cirrhosis, clinically significant portal hypertension and oesophageal varices. METHODS 202 consecutive compensated patients requiring liver biopsy and hepatic venous pressure gradient measurement were included. Several serum tests (alone and combined into scores) and liver stiffness were measured. Artificial neural networks containing or not liver stiffness as input variable were also created. RESULTS The best non-invasive method for diagnosing cirrhosis, portal hypertension and oesophageal varices was liver stiffness (C-statistics=0.93, 0.94, and 0.90, respectively). Among serum tests/scores the best for diagnosing cirrhosis and portal hypertension and oesophageal varices were, respectively, Fibrosis-4, and Lok score. Artificial neural networks including liver stiffness had high diagnostic performance for cirrhosis, portal hypertension and oesophageal varices (accuracy>80%), but were not statistically superior to liver stiffness alone. CONCLUSIONS Liver stiffness was the best non-invasive method to assess the presence of cirrhosis, portal hypertension and oesophageal varices. The use of artificial neural networks integrating different non-invasive tests did not increase the diagnostic accuracy of liver stiffness alone.
Resumo:
STUDY DESIGN Single centre retrospective study of prospectively collected data, nested within the Eurospine Spine Tango data acquisition system. OBJECTIVE The aim of this study was to assess the patient-rated outcome and complication rates associated with lumbar fusion procedures in three different age groups. SUMMARY OF BACKGROUND DATA There is a general reluctance to consider spinal fusion procedures in elderly patients due to the increased likelihood of complications. METHODS Before and at 3, 12, and 24 months after surgery, patients completed the multidimensional Core Outcome Measures Index (COMI). At the 3-, 12-, and 24-month follow-ups they also rated the Global Treatment Outcome (GTO) and their satisfaction with care. Patients were divided into three age groups: younger (≥50y < 65y; n = 317), older (≥65y < 80y; n = 350), and geriatric (≥ 80y; n = 40). RESULTS 707 consecutive patients were included. The preoperative comorbidity status differed significantly (p < 0.0001) between the age groups, with the highest scores in the geriatric group. Medical complications during surgery were lower in the younger age group (7%) than in the older (13.4%; p = 0.006) and geriatric groups (17.5%; p = 0.007); surgical complications tended to be higher in the elderly group (younger, 6.3%; older, 6.0%; geriatric, 15.0%; p = 0.09). There were no significant group differences (p > 0.05) for the scores on any of the COMI domains, GTO, or patient-rated satisfaction at either 3-, 12-, and 24-months follow-up. CONCLUSIONS Despite greater comorbidity and complication rates in geriatric patients, the patient-rated outcome was as good in the elderly as it was in younger age groups up to two years after surgery. These data indicate that geriatric age needs careful consideration of associated risks but is not per se a contraindication for fusion for lumbar degenerative disease. LEVEL OF EVIDENCE 4.
Resumo:
BACKGROUND: Cardiovascular diseases are the leading cause of death worldwide and in Switzerland. When applied, treatment guidelines for patients with acute ST-segment elevation myocardial infarction (STEMI) improve the clinical outcome and should eliminate treatment differences by sex and age for patients whose clinical situations are identical. In Switzerland, the rate at which STEMI patients receive revascularization may vary by patient and hospital characteristics. AIMS: To examine all hospitalizations in Switzerland from 2010-2011 to determine if patient or hospital characteristics affected the rate of revascularization (receiving either a percutaneous coronary intervention or a coronary artery bypass grafting) in acute STEMI patients. DATA AND METHODS: We used national data sets on hospital stays, and on hospital infrastructure and operating characteristics, for the years 2010 and 2011, to identify all emergency patients admitted with the main diagnosis of acute STEMI. We then calculated the proportion of patients who were treated with revascularization. We used multivariable multilevel Poisson regression to determine if receipt of revascularization varied by patient and hospital characteristics. RESULTS: Of the 9,696 cases we identified, 71.6% received revascularization. Patients were less likely to receive revascularization if they were female, and 80 years or older. In the multivariable multilevel Poisson regression analysis, there was a trend for small-volume hospitals performing fewer revascularizations but this was not statistically significant while being female (Relative Proportion = 0.91, 95% CI: 0.86 to 0.97) and being older than 80 years was still associated with less frequent revascularization. CONCLUSION: Female and older patients were less likely to receive revascularization. Further research needs to clarify whether this reflects differential application of treatment guidelines or limitations in this kind of routine data.
Resumo:
PURPOSE To compare patient outcomes and complication rates after different decompression techniques or instrumented fusion (IF) in lumbar spinal stenosis (LSS). METHODS The multicentre study was based on Spine Tango data. Inclusion criteria were LSS with a posterior decompression and pre- and postoperative COMI assessment between 3 and 24 months. 1,176 cases were assigned to four groups: (1) laminotomy (n = 642), (2) hemilaminectomy (n = 196), (3) laminectomy (n = 230) and (4) laminectomy combined with an IF (n = 108). Clinical outcomes were achievement of minimum relevant change in COMI back and leg pain and COMI score (2.2 points), surgical and general complications, measures taken due to complications, and reintervention on the index level based on patient information. The inverse propensity score weighting method was used for adjustment. RESULTS Laminotomy, hemilaminectomy and laminectomy were significantly less beneficial than laminectomy in combination with IF regarding leg pain (ORs with 95% CI 0.52, 0.34-0.81; 0.25, 0.15-0.41; 0.44, 0.27-0.72, respectively) and COMI score improvement (ORs with 95% CI 0.51, 0.33-0.81; 0.30, 0.18-0.51; 0.48, 0.29-0.79, respectively). However, the sole decompressions caused significantly fewer surgical (ORs with 95% CI 0.42, 0.26-0.69; 0.33, 0.17-0.63; 0.39, 0.21-0.71, respectively) and general complications (ORs with 95% CI 0.11, 0.04-0.29; 0.03, 0.003-0.41; 0.25, 0.09-0.71, respectively) than laminectomy in combination with IF. Accordingly, the likelihood of required measures was also significantly lower after laminotomy (OR 0.28, 95% CI 0.17-0.46), hemilaminectomy (OR 0.28, 95% CI 0.15-0.53) and after laminectomy (OR 0.39, 95% CI 0.22-0.68) in comparison with laminectomy with IF. The likelihood of a reintervention was not significantly different between the treatment groups. DISCUSSION As already demonstrated in the literature, decompression in patients with LSS is a very effective treatment. Despite better patient outcomes after laminectomy in combination with IF, caution is advised due to higher rates of surgical and general complications and consequent required measures. Based on the current study, laminotomy or laminectomy, rather than hemilaminectomy, is recommendable for minimum relevant pain relief.