190 resultados para LEFT-VENTRICULAR FUNCTION
Resumo:
AIMS CO₂ is an intrinsic vasodilator for cerebral and myocardial blood vessels. Myocardial vasodilation without a parallel increase of the oxygen demand leads to changes in myocardial oxygenation. Because apnoea and hyperventilation modify blood CO₂, we hypothesized that voluntary breathing manoeuvres induce changes in myocardial oxygenation that can be measured by oxygenation-sensitive cardiovascular magnetic resonance (CMR). METHODS AND RESULTS Fourteen healthy volunteers were studied. Eight performed free long breath-hold as well as a 1- and 2-min hyperventilation, whereas six aquatic athletes were studied during a 60-s breath-hold and a free long breath-hold. Signal intensity (SI) changes in T₂*-weighted, steady-state free precession, gradient echo images at 1.5 T were monitored during breathing manoeuvres and compared with changes in capillary blood gases. Breath-holds lasted for 35, 58 and 117 s, and hyperventilation for 60 and 120 s. As expected, capillary pCO₂ decreased significantly during hyperventilation. Capillary pO₂ decreased significantly during the 117-s breath-hold. The breath-holds led to a SI decrease (deoxygenation) in the left ventricular blood pool, while the SI of the myocardium increased by 8.2% (P = 0.04), consistent with an increase in myocardial oxygenation. In contrast, hyperventilation for 120 s, however, resulted in a significant 7.5% decrease in myocardial SI/oxygenation (P = 0.02). Change in capillary pCO₂ was the only independently correlated variable predicting myocardial oxygenation changes during breathing manoeuvres (r = 0.58, P < 0.01). CONCLUSION In healthy individuals, breathing manoeuvres lead to changes in myocardial oxygenation, which appear to be mediated by CO₂. These changes can be monitored in vivo by oxygenation-sensitive CMR and thus, may have value as a diagnostic tool.
Resumo:
BACKGROUND Pulmonary hypertension (PH) frequently coexists with severe aortic stenosis, and PH severity has been shown to predict outcomes after transcatheter aortic valve implantation (TAVI). The effect of PH hemodynamic presentation on clinical outcomes after TAVI is unknown. METHODS AND RESULTS Of 606 consecutive patients undergoing TAVI, 433 (71.4%) patients with severe aortic stenosis and a preprocedural right heart catheterization were assessed. Patients were dichotomized according to whether PH was present (mean pulmonary artery pressure, ≥25 mm Hg; n=325) or not (n=108). Patients with PH were further dichotomized by left ventricular end-diastolic pressure into postcapillary (left ventricular end-diastolic pressure, >15 mm Hg; n=269) and precapillary groups (left ventricular end-diastolic pressure, ≤15 mm Hg; n=56). Finally, patients with postcapillary PH were divided into isolated (n=220) and combined (n=49) subgroups according to whether the diastolic pressure difference (diastolic pulmonary artery pressure-left ventricular end-diastolic pressure) was normal (<7 mm Hg) or elevated (≥7 mm Hg). Primary end point was mortality at 1 year. PH was present in 325 of 433 (75%) patients and was predominantly postcapillary (n=269/325; 82%). Compared with baseline, systolic pulmonary artery pressure immediately improved after TAVI in patients with postcapillary combined (57.8±14.1 versus 50.4±17.3 mm Hg; P=0.015) but not in those with precapillary (49.0±12.6 versus 51.6±14.3; P=0.36). When compared with no PH, a higher 1-year mortality rate was observed in both precapillary (hazard ratio, 2.30; 95% confidence interval, 1.02-5.22; P=0.046) and combined (hazard ratio, 3.15; 95% confidence interval, 1.43-6.93; P=0.004) but not isolated PH patients (P=0.11). After adjustment, combined PH remained a strong predictor of 1-year mortality after TAVI (hazard ratio, 3.28; P=0.005). CONCLUSIONS Invasive stratification of PH according to hemodynamic presentation predicts acute response to treatment and 1-year mortality after TAVI.
Resumo:
Herzunterstützungssysteme werden bei Patienten mit terminalem Herzversagen und im kardiogenen Schock verwendet. Therapieziele sind die Überbrückung bis zur Transplantation bzw. zur Organerholung. Berichtet wird über den Todesfall eines 69 Jahre alt gewordenen Mannes, dem 2 Jahre vor Todeseintritt ein Linksherzunterstützungssystem implantiert worden war. Mit diesem Herzunterstützungssystem konnte er über einen Zeitraum von 2 Jahren zufriedenstellend leben. Er starb an einem auch laborchemisch gesicherten akuten Myokardinfarkt bei Funktionsfähigkeit des Unterstützungssystems und der Schrittmachereinheit.
Resumo:
INTRODUCTION Post-mortem cardiac MR exams present with different contraction appearances of the left ventricle in cardiac short axis images. It was hypothesized that the grade of post-mortem contraction may be related to the post-mortem interval (PMI) or cause of death and a phenomenon caused by internal rigor mortis that may give further insights in the circumstances of death. METHOD AND MATERIALS The cardiac contraction grade was investigated in 71 post-mortem cardiac MR exams (mean age at death 52y, range 12-89y; 48 males, 23 females). In cardiac short axis images the left ventricular lumen volume as well as the left ventricular myocardial volume were assessed by manual segmentation. The quotient of both (LVQ) represents the grade of myocardial contraction. LVQ was correlated to the PMI, sex, age, cardiac weight, body mass and height, cause of death and pericardial tamponade when present. In cardiac causes of death a separate correlation was investigated for acute myocardial infarction cases and arrhythmic deaths. RESULTS LVQ values ranged from 1.99 (maximum dilatation) to 42.91 (maximum contraction) with a mean of 15.13. LVQ decreased slightly with increasing PMI, however without significant correlation. Pericardial tamponade positively correlated with higher LVQ values. Variables such as sex, age, body mass and height, cardiac weight and cause of death did not correlate with LVQ values. There was no difference in LVQ values for myocardial infarction without tamponade and arrhythmic deaths. CONCLUSION Based on the observation in our investigated cases, the phenomenon of post-mortem myocardial contraction cannot be explained by the influence of the investigated variables, except for pericardial tamponade cases. Further research addressing post-mortem myocardial contraction has to focus on other, less obvious factors, which may influence the early post-mortem phase too.
Resumo:
OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures.
Resumo:
Gebiet: Chirurgie Abstract: OBJECTIVES: – The number of heart transplantations is limited by donor organ availability. Donation after circulatory determination of death (DCDD) could significantly improve graft availability, however, organs undergo warm ischaemia followed by reperfusion, leading to tissue damage. Laboratory studies suggest that mechanical postconditioning [(MPC), brief, intermittent periods of ischaemia at the onset of reperfusion] can limit reperfusion injury, however, clinical translation has been disappointing. We hypothesized that MPC-induced cardioprotection depends on fatty acid levels at reperfusion. – – METHODS: – Experiments were performed with an isolated rat heart model of DCDD. Hearts of male Wistar rats (n = 42) underwent working-mode perfusion for 20 min (baseline), 27 min of global ischaemia and 60 min reperfusion with or without MPC (two cycles of 30 s reperfusion/30 s ischaemia) in the presence or absence of high fat [(HF), 1.2 mM palmitate]. Haemodynamic parameters, necrosis factors and oxygen consumption (O2C) were assessed. Recovery rate was calculated as the value at 60 min reperfusion expressed as a percentage of the mean baseline value. The Kruskal-Wallis test was used to provide an overview of differences between experimental groups, and pairwise comparisons were performed to compare specific time points of interest for parameters with significant overall results. – – RESULTS: – Percent recovery of left ventricular (LV) work [developed pressure (DP)-heart rate product] at 60 min reperfusion was higher in hearts reperfused without fat versus with fat (58 ± 8 vs 23 ± 26%, P < 0.01) in the absence of MPC. In the absence of fat, MPC did not affect post-ischaemic haemodynamic recovery. Among the hearts reperfused with HF, two significantly different subgroups emerged according to recovery of LV work: low recovery (LoR) and high recovery (HiR) subgroups. At 60 min reperfusion, recovery was increased with MPC versus no MPC for LV work (79 ± 6 vs 55 ± 7, respectively, P < 0.05) in HiR subgroups and for DP (40 ± 27 vs 4 ± 2%), dP/dtmax (37 ± 24 vs 5 ± 3%) and dP/dtmin (33 ± 21 vs 5 ± 4%, P < 0.01 for all) in LoR subgroups. – – CONCLUSIONS: – Effects of MPC depend on energy substrate availability, MPC increased recovery of LV work in the presence, but not in the absence, of HF. Controlled reperfusion may be useful for therapeutic strategies aimed at improving post-ischaemic recovery of cardiac DCDD grafts, and ultimately in increasing donor heart availability.
Resumo:
AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.
Resumo:
AIM To evaluate the prognostic value of electrophysiological stimulation (EPS) in the risk stratification for tachyarrhythmic events and sudden cardiac death (SCD). METHODS We conducted a prospective cohort study and analyzed the long-term follow-up of 265 consecutive patients who underwent programmed ventricular stimulation at the Luzerner Kantonsspital (Lucerne, Switzerland) between October 2003 and April 2012. Patients underwent EPS for SCD risk evaluation because of structural or functional heart disease and/or electrical conduction abnormality and/or after syncope/cardiac arrest. EPS was considered abnormal, if a sustained ventricular tachycardia (VT) was inducible. The primary endpoint of the study was SCD or, in implanted patients, adequate ICD-activation. RESULTS During EPS, sustained VT was induced in 125 patients (47.2%) and non-sustained VT in 60 patients (22.6%); in 80 patients (30.2%) no arrhythmia could be induced. In our cohort, 153 patients (57.7%) underwent ICD implantation after the EPS. During follow-up (mean duration 4.8 ± 2.3 years), a primary endpoint event occurred in 49 patients (18.5%). The area under the receiver operating characteristic curve (AUROC) was 0.593 (95%CI: 0.515-0.670) for a left ventricular ejection fraction (LVEF) < 35% and 0.636 (95%CI: 0.563-0.709) for inducible sustained VT during EPS. The AUROC of EPS was higher in the subgroup of patients with LVEF ≥ 35% (0.681, 95%CI: 0.578-0.785). Cox regression analysis showed that both, sustained VT during EPS (HR: 2.26, 95%CI: 1.22-4.19, P = 0.009) and LVEF < 35% (HR: 2.00, 95%CI: 1.13-3.54, P = 0.018) were independent predictors of primary endpoint events. CONCLUSION EPS provides a benefit in risk stratification for future tachyarrhythmic events and SCD and should especially be considered in patients with LVEF ≥ 35%.
Resumo:
OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.
Resumo:
The tricuspid valve is frequently affected in adults with congenital heart disease (CHD). Disease of this valve can occur primarily or develop secondary to changes in the right ventricle caused by other defects. Quantitative echocardiographic assessment of tricuspid regurgitation is essential to assess its cause and prognosis. Treatment options vary depending on the underlying defect and right ventricular function. Surgical management of tricuspid valve disease is complex and evolving.