155 resultados para Pulmonary artery catheter complications
Resumo:
Pulmonary emphysema causes decrease in lung function due to irreversible dilatation of intrapulmonary air spaces, which is linked to high morbidity and mortality. Lung volume reduction (LVR) is an invasive therapeutical option for pulmonary emphysema in order to improve ventilation mechanics. LVR can be carried out by lung resection surgery or different minimally invasive endoscopical procedures. All LVR-options require mandatory preinterventional evaluation to detect hyperinflated dysfunctional lung areas as target structures for treatment. Quantitative computed tomography can determine the volume percentage of emphysematous lung and its topographical distribution based on the lung's radiodensity. Modern techniques allow for lobebased quantification that facilitates treatment planning. Clinical tests still play the most important role in post-interventional therapy monitoring, but CT is crucial in the detection of postoperative complications and foreshadows the method's high potential in sophisticated experimental studies. Within the last ten years, LVR with endobronchial valves has become an extensively researched minimally-invasive treatment option. However, this therapy is considerably complicated by the frequent occurrence of functional interlobar shunts. The presence of "collateral ventilation" has to be ruled out prior to valve implantations, as the presence of these extraanatomical connections between different lobes may jeopardize the success of therapy. Recent experimental studies evaluated the automatic detection of incomplete lobar fissures from CT scans, because they are considered to be a predictor for the existence of shunts. To date, these methods are yet to show acceptable results. KEY POINTS Today, surgical and various minimal invasive methods of lung volume reduction are in use. Radiological and nuclear medical examinations are helpful in the evaluation of an appropriate lung area. Imaging can detect periinterventional complications. Reduction of lung volume has not yet been conclusively proven to be effective and is a therapeutical option with little scientific evidence.
Resumo:
Idiopathic pulmonary fibrosis (IPF) is a chronic progressive lung disease with poor survival. Recent studies have improved understanding of IPF and new discoveries have led to novel treatment options, which now have become available for patients. In face of the newly available therapies we present an update on the pathophysiology and epidemiology of IPF. We discuss the typical clinical findings and elaborate diagnostic procedures according to current guidelines and our daily practice approach. The role of biomarkers will briefly be outlined. Finally, we discuss novel antifibrotic treatment options for IPF (pirfenidone, nintedanib) and the management of patients regarding to comorbidities and complications. Both pirfenidone and nintedanib were shown to reduce the progression of IPF and therefore represent novel therapeutic strategies in this so far untreatable chronic lung disease.
Resumo:
BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.
Resumo:
BACKGROUND Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. METHODS AND RESULTS PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. CONCLUSIONS Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable.
Resumo:
BACKGROUND Long-term outcomes following ventricular tachycardia (VT) ablation are sparsely described. OBJECTIVES To describe long term prognosis following VT ablation in patients with no structural heart disease (no SHD), ischemic (ICM) and non-ischemic cardiomyopathy (NICM). METHODS Consecutive patients (n=695; no SHD 98, ICM 358, NICM 239 patients) ablated for sustained VT were followed for a median of 6 years. Acute procedural parameters (complete success [non-inducibility of any VT]) and outcomes after multiple procedures were reported. RESULTS Compared with patients with no SHD or NICM, ICM patients were the oldest, had more males, lowest left ventricular ejection fraction (LVEF), highest drug failures, VT storms and number of inducible VTs. Complete procedure success was highest in no SHD, compared ICM and NICM patients (79%, 56%, 60% respectively, P<0.001). At 6 years, ventricular arrhythmia (VA)-free survival was highest in no SHD (77%) than ICM (54%) and NICM (38%, P<0.001) and overall survival was lowest in ICM (48%), followed by NICM (74%) and no SHD patients (100%, P<0.001). Age, LVEF, presence of SHD, acute procedural success (non-inducibility of any VT), major complications, need for non-radiofrequency ablation modalities, and VA recurrence were independently associated with all cause mortality. CONCLUSIONS Long term follow up following VT ablation shows excellent prognosis in the absence of SHD, highest VA recurrence and transplantation in NICM and highest mortality in patients with ICM. The extremely low mortality for those without SHD suggests that VT in this population is very rarely an initial presentation of a myopathic process.