243 resultados para REMODELACIÓN ATRIAL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial septal defects (ASDs) are one of the most frequent congenital cardiac malformations, accounting for about 8-10% of all congenital heart defects. The prevalence of pulmonary arterial hypertension (PAH) in adults with an ASD is 8-10%. Different clinical PAH scenarios can be encountered. At one end of the spectrum are adults with no or only mild pulmonary vascular disease and a large shunt. These are patients who can safely undergo shunt closure. In the elderly, mild residual pulmonary hypertension after shunt closure is the rule. At the other end of the spectrum are adults with severe, irreversible pulmonary vascular disease, shunt reversal and chronic cyanosis, that is, Eisenmenger syndrome. These are patients who need to be managed medically. The challenge is to properly classify ASD patients with PAH falling in between the two ends of the spectrum as the ones with advanced, but reversible pulmonary vascular disease amenable to repair, versus the ones with progressive pulmonary vascular disease not responding to shunt closure. There are concerns that adults with progressive pulmonary vascular disease have worse outcomes after shunt closure than patients not undergoing shunt closure. Due to the correlation of pulmonary vascular changes and pulmonary hemodynamics, cardiac catheterization is used in the decision-making process. It is important to consider the hemodynamic data in the context of the clinical picture, the defect anatomy and further noninvasive tests when evaluating the option of shunt closure in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

UNLABELLED Obesity is a well-recognized risk factor for atrial fibrillation (AF), yet adiposity measures other than body mass index (BMI) have had limited assessment in relation to AF risk. We examined the associations of adiposity measures with AF in a biracial cohort of older adults. Given established racial differences in obesity and AF, we assessed for differences by black and white race in relating adiposity and AF. METHODS We analyzed data from 2,717 participants of the Health, Aging, and Body Composition Study. Adiposity measures were BMI, abdominal circumference, subcutaneous and visceral fat area, and total and percent fat mass. We determined the associations between the adiposity measures and 10-year incidence of AF using Cox proportional hazards models and assessed for their racial differences in these estimates. RESULTS In multivariable-adjusted models, 1-SD increases in BMI, abdominal circumference, and total fat mass were associated with a 13% to 16% increased AF risk (hazard ratio [HR] 1.14, 95% CI 1.02-1.28; HR 1.16, 95% CI 1.04-1.28; and HR 1.13, 95% CI 1.002-1.27). Subcutaneous and visceral fat areas were not significantly associated with incident AF. We did not identify racial differences in the associations between the adiposity measures and AF. CONCLUSION Body mass index, abdominal circumference, and total fat mass are associated with risk of AF for 10years among white and black older adults. Obesity is one of a limited number of modifiable risk factors for AF; future studies are essential to evaluate how obesity reduction can modify the incidence of AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT Hyperthyroidism is an established risk factor for atrial fibrillation (AF), but information concerning the association with variations within the normal range of thyroid function and subgroups at risk is lacking. OBJECTIVE This study aimed to investigate the association between normal thyroid function and AF prospectively and explore potential differential risk patterns. DESIGN, SETTING, AND PARTICIPANTS From the Rotterdam Study we included 9166 participants ≥ 45 y with TSH and/or free T4 (FT4) measurements and AF assessment (1997-2012 median followup, 6.8 y), with 399 prevalent and 403 incident AF cases. MAIN OUTCOME MEASURES Outcome measures were 3-fold: 1) hazard ratios (HRs) for the risk of incident AF by Cox proportional-hazards models, 2) 10-year absolute risks taking competing risk of death into account, and 3) discrimination ability of adding FT4 to the CHARGE-AF simple model, an established prediction model for AF. RESULTS Higher FT4 levels were associated with higher risks of AF (HR 1.63, 95% confidence interval, 1.19-2.22), when comparing those in the highest quartile to those in lowest quartile. Absolute 10-year risks increased with higher FT4 in participants ≤ 65 y from 1-9% and from 6-12% in subjects ≥ 65 y. Discrimination of the prediction model improved when adding FT4 to the simple model (c-statistic, 0.722 vs 0.729; P = .039). TSH levels were not associated with AF. CONCLUSIONS There is an increased risk of AF with higher FT4 levels within the normal range, especially in younger subjects. Adding FT4 to the simple model slightly improved discrimination of risk prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate horses with atrial fibrillation for hypercoagulability; plasma D-dimer concentrations, as a marker of a procoagulant state; and a relationship between coagulation profile results and duration of atrial fibrillation or presence of structural heart disease. DESIGN Case-control study. ANIMALS Plasma samples from 42 horses (25 with atrial fibrillation and 17 without cardiovascular or systemic disease [control group]). PROCEDURES Results of hematologic tests (ie, plasma fibrinogen and D-dimer concentrations, prothrombin and activated partial thromboplastin times, and antithrombin activity) in horses were recorded to assess coagulation and fibrinolysis. Historical and clinical variables, as associated with a hypercoagulable state in other species, were also recorded. RESULTS Horses with atrial fibrillation and control horses lacked clinical signs of hypercoagulation or thromboembolism. Compared with control horses, horses with atrial fibrillation had significantly lower antithrombin activity. No significant differences in plasma fibrinogen and D-dimer concentrations and prothrombin and activated partial thromboplastin times existed between horse groups. In horses with atrial fibrillation versus control horses, a significantly larger proportion had an abnormal plasma D-dimer concentration (10/25 vs 2/17), test results indicative of subclinical activated coagulation (18/25 vs 6/17), or abnormal coagulation test results (25/121 vs 7/85), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Horses with atrial fibrillation did not have clinical evidence of a hypercoagulable state, but a higher proportion of horses with atrial fibrillation, compared with control horses, did have subclinical activated coagulation on the basis of standard coagulation test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to assess the safety and efficacy of percutaneous closure of atrial septal defects (ASDs) under fluoroscopic guidance only, without periprocedural echocardiographic guidance. BACKGROUND Percutaneous closure of ASDs is usually performed using simultaneous fluoroscopic and transthoracic, transesophageal (TEE), or intracardiac echocardiographic (ICE) guidance. However, TEE requires deep sedation or general anesthesia, which considerably lengthens the procedure. TEE and ICE increase costs. METHODS Between 1997 and 2008, a total of 217 consecutive patients (age, 38 ± 22 years; 155 females and 62 males), of whom 44 were children ≤16 years, underwent percutaneous ASD closure with an Amplatzer ASD occluder (AASDO). TEE guidance and general anesthesia were restricted to the children, while devices were implanted under fluoroscopic guidance only in the adults. For comparison of technical safety and feasibility of the procedure without echocardiographic guidance, the children served as a control group. RESULTS The implantation procedure was successful in all but 3 patients (1 child and 2 adults; 1.4%). Mean device size was 23 ± 8 mm (range, 4-40 mm). There was 1 postprocedural complication (0.5%; transient perimyocarditis in an adult patient). At last echocardiographic follow-up, 13 ± 23 months after the procedure, 90% of patients had no residual shunt, whereas a minimal, moderate, or large shunt persisted in 7%, 1%, and 2%, respectively. Four adult patients (2%) underwent implantation of a second device for a residual shunt. During a mean follow-up period of 3 ± 2 years, 2 deaths and 1 ischemic stroke occurred. CONCLUSION According to these results, percutaneous ASD closure using the AASDO without periprocedural echocardiographic guidance seems safe and feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF. METHODS In 50 patients (25 patients with PAF; 25 controls) an eECG and surface ECG was recorded simultaneously. Partially A-V blocked atrial runs (PBARs) were quantified, atrial signal duration in eECG was measured. RESULTS eECG revealed 1.8‰ of atrial premature beats in patients with known PAF to be PBARs with a median duration of 853ms (interquartile range (IQR) 813-1836ms) and a median atrial cycle length of 366ms (IQR 282-432ms). Even during a short recording duration of 2.1h (IQR 1.2-17.2h), PBARs occurred in 20% of PAF patients but not in controls (p=0.05). Left atrial signal duration was predictive for PAF (72% sensitivity, 80% specificity). CONCLUSIONS eECG reveals partially blocked atrial runs and prolonged left atrial signal duration - two novel surrogate markers for PAF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. METHODS AND RESULTS PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. CONCLUSIONS Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Arrhythmias in cardiac amyloidosis (CA) result in significant comorbidity and mortality but have not been well characterized. OBJECTIVE The purpose of this study was to define intracardiac conduction, atrial arrhythmia substrate, and ablation outcomes in a group of advanced CA patients referred for electrophysiologic study. METHODS Electrophysiologic study with or without catheter ablation was performed in 18 CA patients. Findings and catheter ablation outcomes were compared to age- and gender-matched non-CA patients undergoing catheter ablation of persistent atrial fibrillation (AF). RESULTS Supraventricular tachycardias were seen in all 18 CA patients (1 AV nodal reentrant tachycardia, 17 persistent atrial tachycardia [AT]/AF). The HV interval was prolonged (>55 ms) in all CA patients, including 6 with normal QRS duration (≤100 ms). Thirteen supraventricular tachycardia ablations were performed in 11 patients. Of these, 7 underwent left atrial (LA) mapping and ablation for persistent AT/AF. Compared to non-CA age-matched comparator AF patients, CA patients had more extensive areas of low-voltage areas LA (63% ± 22% vs 34% ± 22%, P = .009) and a greater number of inducible ATs (3.3 ± 1.9 ATs vs 0.2 ± 0.4 ATs, P <.001). The recurrence rate for AT/AF 1 year after ablation was greater in CA patients (83% vs 25%), and the hazard ratio for postablation AT/AF recurrence in CA patients was 5.4 (95% confidence interval 1.9-35.5, P = .007). CONCLUSION In this group of patients with advanced CA and atrial arrhythmias, there was extensive conduction system disease and LA endocardial voltage abnormality. Catheter ablation persistent AT/AF in advanced CA was associated with a high recurrence rate and appears to have a limited role in control of these arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The study set out to identify clinical, laboratory and radiological predictors of early mortality after an acute ischaemic stroke (AIS) and to analyse medical and neurological complications that caused death. METHODS A total of 479 consecutive patients (mean age 63+/-14 years) with AIS underwent stroke examination and treatment. Examination included clinical evaluation, laboratory tests, and brain CT and/or MRI. Follow-up data at 30 days were available for 467 patients (93%) who were included in the present analysis. RESULTS The median National Institute of Health Stroke Study (NIHSS) score on admission was 6. A total of 62 patients (13%) died within 30 days. The cause of death was the initial event in 43 (69%), pneumonia in 12 (19%), intracerebral haemorrhage in 9 (15%), recurrent stroke in 6 (10%), myocardial infarction in 2 (3%), and cancer in 1 (2%) of the patients. In univariate comparisons, advanced age (p<0.001), hypertension (p=0.013), coronary disease (p=0.001), NIHSS score (p<0.001), undetermined stroke etiology (p=0.031), relevant co-morbidities (p=0.008), hyperglycemia (p<0.001), atrial fibrillation (p<0.001), early CT signs of ischemia (p<0.001), dense artery sign (p<0.001), proximal vessel occlusion (p<0.001), and thrombolysis (p=0.008) were associated with early mortality. In multivariate analysis, advanced age (HR=1.12; 95% CI 1.05-1.19; p<0.001) and high NIHSS score on admission (HR=1.15, 95% CI 1.05-1.25; p=0.002) were independent predictors of early mortality. CONCLUSIONS We report 13% mortality at 30 days after AIS. More than two thirds of the deaths are related to the initial stroke. Advanced age and high NIHSS score are the only independent predictors of early mortality in this series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cardiac voltage-gated Na(+) channel Na(v)1.5 generates the cardiac Na(+) current (INa). Mutations in SCN5A, the gene encoding Na(v)1.5, have been linked to many cardiac phenotypes, including the congenital and acquired long QT syndrome, Brugada syndrome, conduction slowing, sick sinus syndrome, atrial fibrillation, and dilated cardiomyopathy. The mutations in SCN5A define a sub-group of Na(v)1.5/SCN5A-related phenotypes among cardiac genetic channelopathies. Several research groups have proposed that Na(v)1.5 may be part of multi-protein complexes composed of Na(v)1.5-interacting proteins which regulate channel expression and function. The genes encoding these regulatory proteins have also been found to be mutated in patients with inherited forms of cardiac arrhythmias. The proteins that associate with Na(v)1.5 may be classified as (1) anchoring/adaptor proteins, (2) enzymes interacting with and modifying the channel, and (3) proteins modulating the biophysical properties of Na(v)1.5 upon binding. The aim of this article is to review these Na(v)1.5 partner proteins and to discuss how they may regulate the channel's biology and function. These recent investigations have revealed that the expression level, cellular localization, and activity of Na(v)1.5 are finely regulated by complex molecular and cellular mechanisms that we are only beginning to understand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patent foramen ovale is found in 24% of healthy adults and 38% of patients with cryptogenic stroke. This ratio and case reports indicate that patent foramen ovale and stroke are associated, probably because of paradoxical embolism. In healthy people with patent foramen ovale, embolic events are not more frequent than in controls, and therefore no primary prevention is needed. However, once ischaemic events occur, the risk of recurrence is substantial and prevention becomes an issue. Acetylsalicylic acid and warfarin reduce this risk to the same level as in patients without patent foramen ovale. Patent foramen ovale with a coinciding atrial septal aneurysm, spontaneous or large right-to-left shunt, or multiple ischaemic events potentiates the risk of recurrence. Transcatheter device closure has therefore become an intriguing addition to medical treatment, but its therapeutic value still needs to be confirmed by randomised-controlled trials.