46 resultados para stabilization ponds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastrinomas, a rare group of neuroendocrine tumors, are responsible for severe peptic disease and diarrhea. Although symptomatic control may be achieved with proton-pump inhibitors (PPIs) and somatostatin analogues (SSAs), data are limited regarding the possible antitumor effect of the peptide receptor radioligand therapy (PRRT) with radiolabeled SSAs in gastrinoma patients. The goal of this study was to assess the effect of PRRT on symptoms, gastrin secretion, and tumor load in patients with progressive malignant gastrinomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proximal humerus fractures (pHF) are common. In this retrospective study intra-operative and postoperative data and complications of patients stabilized with conventional semirigid techniques (pins, n=30; helix wire, n=19) or a novel semirigid technique, the intramedullary claw (IMC, n=82) were compared. The type and frequency of postoperative complications differed between the groups (p<0.001). The IMC is a novel semirigid technique to stabilize pHF and seems to result in fewer complications than pins or helix wire. The frequency and relevance of a loss of repositioning in patients after IMC implantation need to be elucidated in long-term studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lumbopelvic distraction stabilization with (triangular osteosynthesis) or without additional iliosacral screw allows anatomic reduction of the posterior pelvic ring after severely displaced sacral fractures, correction or resection osteotomies of malunions, respectively, septic sacroiliitis and permits early weight bearing. However, this technique is complicated by wound necrosis or infection in up to 20% to 30%. We describe our experience with a less invasive technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to describe the use of a titanium 1.5 mm locking plate in the stabilization of atlantoaxial pathology in three toy breed dogs. Two dogs with atlantoaxial subluxation and another dog with an axial fracture, confirmed by diagnostic imaging, were stabilized via a ventral approach with a 1.5 mm titanium 5-hole locking butterfly-plate. Surgical reduction and stabilization were assessed by computed tomography and radiography after surgery. Follow-up evaluation for resolution of neurological signs and possible complications was performed in all three dogs. For long-term assessment, a telephone follow-up was performed. A considerable improvement of neurological signs occurred within two to four weeks after surgery. An excellent clinical outcome was identified in all three patients. Adequate stabilization and resolution of neurological signs in all three dogs was achieved. The stabilization of atlantoaxial surgical conditions in toy breeds with the 1.5 mm titanium 5-hole butterfly locking plate appears to be an effective means of surgical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN:: retrospective analysis of prospectively collected clinical data. OBJECTIVE:: To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA:: The Dynesys® system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome following treatment for degenerative spondylolisthesis at the L4/5 level. METHODS:: 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range 5.0-11.2▒y) they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS:: At final follow-up back pain improved in 89% and leg pain improved in 86% of patients compared to preoperative status. 83% of patients reported global subjective improvement. 92% would undergo the surgery again. 8 patients (21%) required further surgery due to symptomatic adjacent segment disease (6 cases), late onset infection (1 case), and screw breakage (1 case). In 9 cases radiological progression of spondylolisthesis at the operated segment was found. 74% of operated segments showed limited flexion-extension range of less than 4°. Adjacent segment pathology, though without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases asymptomatic screw loosening was observed. CONCLUSION:: Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiological and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.