10 resultados para high-performance liquid chromatographic methods

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five different methods were critically examined to characterize the pore structure of the silica monoliths. The mesopore characterization was performed using: a) the classical BJH method of nitrogen sorption data, which showed overestimated values in the mesopore distribution and was improved by using the NLDFT method, b) the ISEC method implementing the PPM and PNM models, which were especially developed for monolithic silicas, that contrary to the particulate supports, demonstrate the two inflection points in the ISEC curve, enabling the calculation of pore connectivity, a measure for the mass transfer kinetics in the mesopore network, c) the mercury porosimetry using a new recommended mercury contact angle values. rnThe results of the characterization of mesopores of monolithic silica columns by the three methods indicated that all methods were useful with respect to the pore size distribution by volume, but only the ISEC method with implemented PPM and PNM models gave the average pore size and distribution based on the number average and the pore connectivity values.rnThe characterization of the flow-through pore was performed by two different methods: a) the mercury porosimetry, which was used not only for average flow-through pore value estimation, but also the assessment of entrapment. It was found that the mass transfer from the flow-through pores to mesopores was not hindered in case of small sized flow-through pores with a narrow distribution, b) the liquid penetration where the average flow-through pore values were obtained via existing equations and improved by the additional methods developed according to Hagen-Poiseuille rules. The result was that not the flow-through pore size influences the column bock pressure, but the surface area to volume ratio of silica skeleton is most decisive. Thus the monolith with lowest ratio values will be the most permeable. rnThe flow-through pore characterization results obtained by mercury porosimetry and liquid permeability were compared with the ones from imaging and image analysis. All named methods enable a reliable characterization of the flow-through pore diameters for the monolithic silica columns, but special care should be taken about the chosen theoretical model.rnThe measured pore characterization parameters were then linked with the mass transfer properties of monolithic silica columns. As indicated by the ISEC results, no restrictions in mass transfer resistance were noticed in mesopores due to their high connectivity. The mercury porosimetry results also gave evidence that no restrictions occur for mass transfer from flow-through pores to mesopores in the small scaled silica monoliths with narrow distribution. rnThe prediction of the optimum regimes of the pore structural parameters for the given target parameters in HPLC separations was performed. It was found that a low mass transfer resistance in the mesopore volume is achieved when the nominal diameter of the number average size distribution of the mesopores is appr. an order of magnitude larger that the molecular radius of the analyte. The effective diffusion coefficient of an analyte molecule in the mesopore volume is strongly dependent on the value of the nominal pore diameter of the number averaged pore size distribution. The mesopore size has to be adapted to the molecular size of the analyte, in particular for peptides and proteins. rnThe study on flow-through pores of silica monoliths demonstrated that the surface to volume of the skeletons ratio and external porosity are decisive for the column efficiency. The latter is independent from the flow-through pore diameter. The flow-through pore characteristics by direct and indirect approaches were assessed and theoretical column efficiency curves were derived. The study showed that next to the surface to volume ratio, the total porosity and its distribution of the flow-through pores and mesopores have a substantial effect on the column plate number, especially as the extent of adsorption increases. The column efficiency is increasing with decreasing flow through pore diameter, decreasing with external porosity, and increasing with total porosity. Though this tendency has a limit due to heterogeneity of the studied monolithic samples. We found that the maximum efficiency of the studied monolithic research columns could be reached at a skeleton diameter of ~ 0.5 µm. Furthermore when the intention is to maximize the column efficiency, more homogeneous monoliths should be prepared.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) findet Anwendung in der Therapie mit Immunosuppressiva, Antibiotika, antiretroviraler Medikation, Antikonvulsiva, Antidepressiva und auch Antipsychotika, um die Effizienz zu steigern und das Risiko von Intoxikationen zu reduzieren. Jedoch ist die Anwendung von TDM für Substanzen, die Einsatz finden in der Rückfallprophylaxe, der Substitution oder dem Entzug von Abhängigkeitserkrankungen nicht etabliert. Für diese Arbeit wurde im ersten Schritt eine sensitive Rating-Skala mit 22 Items entwickelt, mit Hilfe derer der theoretische Nutzen von TDM in der Pharmakotherapie von substanzbezogenen Abhängigkeitserkrankungen auf der Basis von pharmakologischen Eigenschaften der Medikamente und von Patientencharakteristika evaluiert wurde. Die vorgenommene Einschätzung zeigte für Bupropion, Buprenorphin, Disulfiram (oder einen Metaboliten), Methadon (chirale Bestimmung wenn möglich) und Naltrexon einen potentiellen Nutzen von TDM.rnFür die meisten Medikamente, die zur Behandlung von Abhängigkeitserkrankungen zugelassen sind, fehlen valide Messverfahren für TDM. Im Alltag werden überwiegend Drogen Screening-Tests in Form immunologischer Schnelltests angewendet. Für die Anwendung von TDM wurden in dieser Arbeit chromatographische Verfahren für die Bestimmung von Naltrexon und 6β-Naltrexol, Bupropion und Hydroxybupropion sowie R,S-Methadon und R,S-2-Ethyliden-1,5-dimethyl-3,3-diphenylpyrrolidin entwickelt, optimiert und validiert. Es handelt sich dabei HPLC-UV-Methoden mit Säulenschaltung sowie zur Bestimmung von Naltrexon und 6β-Naltrexol zusätzlich eine LC-MS/MS-Methode. Voraussetzung für die Interpretation der Plasmaspiegel ist im Wesentlichen die Kenntnis eines therapeutischen Bereichs. Für Naltrexon und seinen aktiven Metaboliten 6β-Naltrexol konnte eine signifikante Korrelation zwischen dem auftretenden Craving und der Summenkonzentration gefunden werden. Mittels Receiver-Operation-Characteristics-Kurven-Analyse wurde ein Schwellenwert von 16,6 ng/ml ermittelt, oberhalb dessen mit einem erhöhten Ansprechen gerechnet werden kann. Für Levomethadon wurde bezüglich der Detoxifikationsbehandlung ein Zusammenhang in der prozentualen Reduktion des Plasmaspiegels und den objektiven und subjektiven Entzugssymptomen gefunden. rnDoch nicht nur die Wirkstoffe, sondern auch das Patientenmerkmal substanzbezogene Abhängigkeit wurde charakterisiert, zum einen bezüglich pharmakokinetischer Besonderheiten, zum anderen in Hinsicht auf die Therapietreue (Adhärenz). Für Patienten mit komorbider Substanzabhängigkeit konnte eine verminderte Adhärenz unabhängig von der Hauptdiagnose gezeigt werden. Die Betrachtung des Einflusses von veränderten Leberwerten zeigt für komorbide Patienten eine hohe Korrelation mit dem Metabolisiererstatus, nicht aber für Patienten ohne Substanzabhängigkeit.rnÜbergeordnetes Ziel von TDM ist die Erhöhung der Therapiesicherheit und die Steigerung der Therapieeffizienz. Dies ist jedoch nur möglich, wenn TDM im klinischen Alltag integriert ist und korrekt eingesetzt wird. Obwohl es klare Evidenz für TDM von psychiatrischer Medikation gibt, ist die Diskrepanz zwischen Laborempfehlung und der klinischen Umsetzung hoch. Durch Intensivierung der interdisziplinären Zusammenarbeit zwischen Ärzten und Labor, der Entwicklung von interaktivem TDM (iTDM), konnte die Qualität der Anwendung von TDM verbessert und das Risiko von unerwünschten Arzneimittelwirkungen vermindert werden. rnInsgesamt konnte durch die eigenen Untersuchungen gezeigt werden, dass TDM für die medikamentöse Einstellung von Patienten mit Abhängigkeitserkrankung sinnvoll ist und dass optimales TDM eine interdisziplinäre Zusammenarbeit erfordert.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) umfasst die Messung von Medikamentenspiegeln im Blut und stellt die Ergebnisse in Zusammenhang mit dem klinischen Erscheinungsbild der Patienten. Dabei wird angenommen, dass die Konzentrationen im Blut besser mit der Wirkung korrelieren als die Dosis. Dies gilt auch für Antidepressiva. Voraussetzung für eine Therapiesteuerung durch TDM ist die Verfügbarkeit valider Messmethoden im Labor und die korrekte Anwendung des Verfahrens in der Klinik. Ziel dieser Arbeit war es, den Einsatz von TDM für die Depressionsbehandlung zu analysieren und zu verbessern. Im ersten Schritt wurde für das neu zugelassene Antidepressivum Duloxetin eine hochleistungsflüssig-chromatographische (HPLC) Methode mit Säulenschaltung und spektrophotometrischer Detektion etabliert und an Patienten für TDM angewandt. Durch Analyse von 280 Patientenproben wurde herausgefunden, dass Duloxetin-Konzentrationen von 60 bis 120 ng/ml mit gutem klinischen Ansprechen und einem geringen Risiko für Nebenwirkungen einhergingen. Bezüglich seines Interaktionspotentials erwies sich Duloxetin im Vergleich zu anderen Antidepressiva als schwacher Inhibitor des Cytochrom P450 (CYP) Isoenzyms 2D6. Es gab keinen Hinweis auf eine klinische Relevanz. Im zweiten Schritt sollte eine Methode entwickelt werden, mit der möglichst viele unterschiedliche Antidepressiva einschließlich deren Metaboliten messbar sind. Dazu wurde eine flüssigchromatographische Methode (HPLC) mit Ultraviolettspektroskopie (UV) entwickelt, mit der die quantitative Analyse von zehn antidepressiven und zusätzlich zwei antipsychotischen Substanzen innerhalb von 25 Minuten mit ausreichender Präzision und Richtigkeit (beide über 85%) und Sensitivität erlaubte. Durch Säulenschaltung war eine automatisierte Analyse von Blutplasma oder –serum möglich. Störende Matrixbestandteile konnten auf einer Vorsäule ohne vorherige Probenaufbereitung abgetrennt werden. Das kosten- und zeiteffektive Verfahren war eine deutliche Verbesserung für die Bewältigung von Proben im Laboralltag und damit für das TDM von Antidepressiva. Durch Analyse des klinischen Einsatzes von TDM wurden eine Reihe von Anwendungsfehlern identifiziert. Es wurde deshalb versucht, die klinische Anwendung des TDM von Antidepressiva durch die Umstellung von einer weitgehend händischen Dokumentation auf eine elektronische Bearbeitungsweise zu verbessern. Im Rahmen der Arbeit wurde untersucht, welchen Effekt man mit dieser Intervention erzielen konnte. Dazu wurde eine Labor-EDV eingeführt, mit der der Prozess vom Probeneingang bis zur Mitteilung der Messergebnisse auf die Stationen elektronisch erfolgte und die Anwendung von TDM vor und nach der Umstellung untersucht. Die Umstellung fand bei den behandelnden Ärzten gute Akzeptanz. Die Labor-EDV erlaubte eine kumulative Befundabfrage und eine Darstellung des Behandlungsverlaufs jedes einzelnen Patienten inklusive vorhergehender Klinikaufenthalte. Auf die Qualität der Anwendung von TDM hatte die Implementierung des Systems jedoch nur einen geringen Einfluss. Viele Anforderungen waren vor und nach der Einführung der EDV unverändert fehlerhaft, z.B. wurden häufig Messungen vor Erreichen des Steady State angefordert. Die Geschwindigkeit der Bearbeitung der Proben war im Vergleich zur vorher händischen Ausführung unverändert, ebenso die Qualität der Analysen bezüglich Richtigkeit und Präzision. Ausgesprochene Empfehlungen hinsichtlich der Dosierungsstrategie der angeforderten Substanzen wurden häufig nicht beachtet. Verkürzt wurde allerdings die mittlere Latenz, mit der eine Dosisanpassung nach Mitteilung des Laborbefundes erfolgte. Insgesamt ist es mit dieser Arbeit gelungen, einen Beitrag zur Verbesserung des Therapeutischen Drug Monitoring von Antidepressiva zu liefern. In der klinischen Anwendung sind allerdings Interventionen notwendig, um Anwendungsfehler beim TDM von Antidepressiva zu minimieren.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aufbau einer kontinuierlichen, mehrdimensionalen Hochleistungs-flüssigchromatographie-Anlage für die Trennung von Proteinen und Peptiden mit integrierter größenselektiver ProbenfraktionierungEs wurde eine mehrdimensionale HPLC-Trennmethode für Proteine und Peptide mit einem Molekulargewicht von <15 kDa entwickelt.Im ersten Schritt werden die Zielanalyte von höhermolekularen sowie nicht ionischen Bestandteilen mit Hilfe von 'Restricted Access Materialien' (RAM) mit Ionenaustauscher-Funktionalität getrennt. Anschließend werden die Proteine auf einer analytischen Ionenaustauscher-Säule sowie auf Reversed-Phase-Säulen getrennt. Zur Vermeidung von Probenverlusten wurde ein kontinuierlich arbeitendes, voll automatisiertes System auf Basis unterschiedlicher Trenngeschwindigkeiten und vier parallelen RP-Säulen aufgebaut.Es werden jeweils zwei RP-Säulen gleichzeitig, jedoch mit zeitlich versetztem Beginn eluiert, um durch flache Gradienten ausreichende Trennleistungen zu erhalten. Während die dritte Säule regeneriert wird, erfolgt das Beladen der vierte Säule durch Anreicherung der Proteine und Peptide am Säulenkopf. Während der Gesamtanalysenzeit von 96 Minuten werden in Intervallen von 4 Minuten Fraktionen aus der 1. Dimension auf die RP-Säulen überführt und innerhalb von 8 Minuten getrennt, wobei 24 RP-Chromatogramme resultieren.Als Testsubstanzen wurden u.a. Standardproteine, Proteine und Peptide aus humanem Hämofiltrat sowie aus Lungenfibroblast-Zellkulturüberständen eingesetzt. Weiterhin wurden Fraktionen gesammelt und mittels MALDI-TOF Massenspektrometrie untersucht. Bei einer Injektion wurden in den 24 RP-Chromatogrammen mehr als 1000 Peaks aufgelöst. Der theoretische Wert der Peakkapazität liegt bei ungefähr 3000.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eisbohrkerne stellen wertvolle Klimaarchive dar, da sie atmosphärisches Aerosol konservieren. Die Analyse chemischer Verbindungen als Bestandteil atmosphärischer Aerosole in Eisbohrkernen liefert wichtige Informationen über Umweltbedingungen und Klima der Vergangenheit. Zur Untersuchung der α-Dicarbonyle Glyoxal und Methylglyoxal in Eis- und Schneeproben wurde eine neue, sensitive Methode entwickelt, die die Stir Bar Sorptive Extraction (SBSE) mit der Hochleistungsflüssigchromatographie-Massenspektrometrie (HPLC-MS) kombiniert. Zur Analyse von Dicarbonsäuren in Eisbohrkernen wurde eine weitere Methode entwickelt, bei der die Festphasenextraktion mit starkem Anionenaustauscher zum Einsatz kommt. Die Methode erlaubt die Quantifizierung aliphatischer Dicarbonsäuren (≥ C6), einschließlich Pinsäure, sowie aromatischer Carbonsäuren (wie Phthalsäure und Vanillinsäure), wodurch die Bestimmung wichtiger Markerverbindungen für biogene und anthropogene Quellen ermöglicht wurde. Mit Hilfe der entwickelten Methoden wurde ein Eisbohrkern aus den Schweizer Alpen analysiert. Die ermittelten Konzentrationsverläufe der Analyten umfassen die Zeitspanne von 1942 bis 1993. Mittels einer Korrelations- und Hauptkomponentenanalyse konnte gezeigt werden, dass die organischen Verbindungen im Eis hauptsächlich durch Waldbrände und durch vom Menschen verursachte Schadstoffemissionen beeinflusst werden. Im Gegensatz dazu sind die Konzentrationsverläufe einiger Analyten auf den Mineralstaubtransport auf den Gletscher zurückzuführen. Zusätzlich wurde ein Screening der Eisbohrkernproben mittels ultrahochauflösender Massenspektrometrie durchgeführt. Zum ersten Mal wurden in diesem Rahmen auch Organosulfate und Nitrooxyorganosulfate in einem Eisbohrkern identifiziert.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

n this work, three Cypraea species (C. talpa, C. tigris and C. zebra) were exhaustively studied. The shells have been separated in the structural layers. The mineralogy, ultra- and micro-structure of each layer were analyzed by Confocal Laser Scanning Microscopy (CLSM), Scanning Electron Microscopy (SEM), X-Ray Diffractometry (XRD) and Raman Spectroscopy (RS). The presence of biologically relevant trace metals (Mn, Co, Fe, Zn, Cr, etc.) has been investigated using Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma – Mass Spectrometry (ICP-MS) as detection tool. A new method has been developed and optimized to extract and analyze the soluble organic matrix (SOM) of the shell. Although the molecular nature of the SOM is not really known, it contains at least large protein fraction, if not only consists of proteins. The extracted matrices were compared between layers and species using Size Exclusion High Performance Liquid Chromatography coupled with Ultra Violet Spectrometry (SE-HPLC-UV), Gel electrophoresis (GE) and protein quantification tests. For the first time to our knowledge the association of trace elements to the protein in the SOM of the shell was studied using hyphenated on line as well as combined off line techniques and validated through inter-comparison tests between the different methods applied. Interesting correlations between the trace element concentration, the microstructure and the protein content were directly and indirectly detected. The metals Cu, Ni, Co and Zn have shown to bind to the SOM extracted from C. talpa, C. tigris and C. zebra shells. Within the conclusions of this work it was demonstrated that these protein-metal-complexes (or metal containing proteins) change from one layer to the other and are different between the three snails analyzed. In addition, the complexes are clearly related only to certain protein fractions of the SOM, and not to the whole SOM observed. These fractions and show not to be very metal-specific (i.e. some of these fractions bind two or three different metals).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eine Voraussetzung für die Entwicklung neuer immunmodulatorischer Therapieverfahren ist die Kenntnis immunogener Tumorantigene, die von tumorreaktiven T-Zellen erkannt werden. In der vorliegenden Arbeit wurden tumorreaktive CD8+ zytotoxische T-Lymphozyten (CTL, cytotoxic T-lymphocytes) aus dem Blut eines HLA (human leukocyte antigen)-kompatiblen Fremdspenders generiert. Methodisch wurden hierzu CD8-selektionierte periphere Blutlymphozyten repetitiv mit der klarzelligen Nierenzellkarzinomlinie MZ1851-RCC (RCC, renal cell carcinoma) in einer allogenen gemischten Lymphozyten-Tumorzell Kultur (MLTC, mixed lymphocyte tumor cell culture) stimuliert. Aus den Responderlymphozyten wurden mit Hilfe des Grenzverdünnungsverfahrens klonale zytotoxische T-Zellen generiert und expandiert. Die CTL-Klone wurden anschließend phänotypisch mittels Durchflußzytometrie sowie funktionell mittels HLA-Antikörper-Blockadeexperimenten und Kreuzreaktivitätstests detailliert charakterisiert. Dabei konnte gezeigt werden, daß aus dem Blut eines allogenen gesunden Spenders CD8+ T-Zellen isoliert werden können, welche Reaktivität gegen Nierenzellkarzinome (NZK) aufweisen und über verschiedene HLA-Klasse-I-Allele restringiert sind. Die von den einzelnen CTL-Klonen erkannten Zielstrukturen zeigten entweder ubiquitäre (z.B. HLA-Cw*0704-reaktiver CTL-Klon E77) oder eine tumorspezifische (z.B. HLA-B*0702-restringierter CTL-Klon A4) Gewebeexpression. Zur Identifizierung der natürlich prozessierten Peptidliganden wurden die HLA-B/C-Allele unter Verwendung des monoklonalen Antikörpers B123.2 aus einem zuvor hergestellten Detergenslysat der Nierenzellkarzinomlinie MZ1851-RCC immunchromatographisch aufgereinigt. Aus den so isolierten HLA-Peptid-Komplexen wurden die tumorassoziierten Peptidliganden nach Säureeluation und Filtration abgespalten und über eine „reverse phase“-HPLC (high performance liquid chromatography) fraktioniert. Die Überprüfung der einzelnen HPLC-Fraktionen auf Bioaktivität erfolgte mit den korrespondierenden CTL-Klonen in 51Cr-Zytotoxizitätstests. Dabei wurde eine HPLC-Fraktion identifiziert, die die lytische Funktion des HLA-B*0702-restringierten CTL-Klons A4 auslösen konnte. Die bioaktive HPLC-Fraktion wurde dazu durch eine zweite (second dimension) Kapillar-Flüssigkeitschromatographie (Cap-LC, capillar liquid chromatography) in Subfraktionen geringerer Komplexität aufgetrennt und die darin enthaltenen Peptidepitope durch das MALDI-TOF/TOF (matrix assisted laser desorption/ionization- time of flight/time of flight)-Analyseverfahren sequenziert. Innerhalb dieser HPLC-Fraktion wurden eine Vielzahl von HLA-B/C-assoziierten Peptidliganden erfolgreich sequenziert, was die Effektivität dieser Verfahrenstechnik zur Identifizierung natürlich prozessierter HLA-Klasse-I-bindender Peptide unter Beweis stellt. Leider war es mit dieser Methode bisher nicht möglich, das von CTL-Klon A4 detektierte Peptidepitop zu sequenzieren. Dies liegt möglicherweise in der unzureichenden Konzentration des Peptidepitops in der bioaktiven HPLC-Fraktion begründet. In Folgearbeiten soll nun mit erhöhter Probenmenge beziehungsweise verbesserter Analytik der erneute Versuch unternommen werden, das Zielantigen des CTL-Klons A4 zu identifizieren. Die Kenntnis von Antigenen, die tumorspezifisch exprimiert und von CD8+ CTL aus gesunden Spendern erkannt werden, eröffnet neue therapeutische Möglichkeiten, das spezifische Immunsystem des Stammzellspenders nach allogener Blutstammzelltransplantation gezielt zur Steigerung von Tumorabstoßungsreaktionen (z.B. durch Vakzinierung oder adoptivem T-Zelltransfer) zu nutzen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) ist eine Maßnahme, bei der durch Messung der Medikamentenspiegel im Blut die Dosis ermittelt wird, bei der mit höchster Wahrscheinlichkeit mit Therapieansprechen gerechnet werden kann. Dabei wird angenommen, dass die Konzentrationen im Blut mit denen im Wirkkompartiment korrelieren. Für Antipsychotika wurde gezeigt, dass die Konzentrationen im Blut direkt mit denen im Gehirn korrelieren, die Verteilung zwischen den beiden Kompartimenten ist jedoch für die verschiedenen Antipsychotika sehr unterschiedlich. Die Distribution von Arzneistoffen zwischen Blut und Gehirn wird durch Effluxtransporter in der Blut-Hirn-Schranke kontrolliert. Welche Rolle dabei P-Glykoprotein (P-gp) für die Verteilung von atypischen Antipsychotika spielt und wie die Pharmakokinetik und –dynamik durch diesen Transporter beeinflusst werden, sollte in dieser Arbeit untersucht werden. Für die Messung des neu eingeführten Antipsychotikums Aripiprazol, sowie für seinen aktiven Metaboliten Dehydroaripiprazol, wurde eine hochleistungsflüssigchromatographische (HPLC) Methode mit Säulenschaltung und spektrophotometrischer Detektion etabliert. Die Methode wurde für die Messung von Serumproben schizophrener Patienten eingesetzt, um einen therapeutischen Bereich für Aripiprazol zu ermitteln. Aus der Analyse von 523 Patientenproben wurde herausgefunden, dass Aripiprazol-Serumkonzentrationen von 150 bis 300 ng/ml mit gutem klinischen Ansprechen und einem geringen Risiko für Nebenwirkungen einhergingen. Weiterhin wurde festgestellt, dass die Serumspiegel bei gleichzeitiger Gabe von Inhibitoren und Induktoren der Cytochrom P450 (CYP) Isoenzyme CYP2D6 und CYP3A4 erhöht bzw. gesenkt wurden. Am Modell der P-gp Knockout Maus im Vergleich zu FVB Wildtyp Mäusen wurden Konzentrationsverläufe von Antipsychotika nach i.p. Gabe von Amisulprid, Aripiprazol, Dehydroaripiprazol, Clozapin, Desmethylclozapin, Haloperidol, Olanzapin, Quetiapin, Risperidon und 9-Hydroxyrisperidon sowie der Kontrollsubstanz Domperidon im Gehirn und Blut über 24 Stunden mittels HPLC-Methoden gemessen. Welchen Einfluss eine verminderte Expression von P-gp auf die Pharmakodynamik hat, wurde in zwei Verhaltenstests untersucht. Mit Hilfe des Rotarods wurden motorische Effekte der Arzneistoffe erfasst und mittels Radial Arm Water Maze kognitive Fähigkeiten. Risperidon und sein aktiver Metabolit 9-Hydroxyrisperidon waren die stärksten Substrate von P-gp. 10-fach höhere Konzentrationen im Gehirn der P-gp Knockout Mäuse führten zu 10-fach stärkeren Beeinträchtigungen in den pharmakodynamischen Untersuchungen im Vergleich zu Wildtyp Tieren. Amisulprid, Aripiprazol, Dehydroaripiprazol, Desmethylclozapin und Quetiapin konnten ebenfalls als Substrate von P-gp identifiziert werden. Olanzapin, Haloperidol und Clozapin wurden durch P-gp wenig bzw. nicht in ihrer Pharmakokinetik und –dynamik beeinflusst. Da P-gp von Nagern und Menschen nach derzeitiger Kenntnis in ihren Substrateigenschaften weitgehend übereinstimmen, muss bei einer Behandlung von schizophrenen Patienten mit Antipsychotika, die als Substrate von P-gp identifiziert wurden, davon ausgegangen werden, dass eine Veränderung der Expression oder Aktivität von P-gp, genetisch verursacht oder durch Medikamente bedingt, für das Therapieansprechen oder das Auftreten von Nebenwirkungen bedeutsam sind.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Der Erfolg einer Schizophrenie-Behandlung ist zum größten Teil abhängig vom Ansprechen des Patienten auf seine antipsychotische Medikation. Welches Medikament und welche Dosis bei einem individuellen Patienten wirksam sind, kann derzeit erst nach mehrwöchiger Behandlung beurteilt werden. Ein Grund für variierendes Therapieansprechen sind variable Plasmakonzentrationen der Antipsychotika. Ziel dieser Arbeit war es, zu untersuchen, in wieweit der Therapieerfolg zu einem frühen Zeitpunkt der Behandlung durch objektive Symptomerfassung vorhersagbar ist und welche Faktoren die hohe Variabilität der Antipsychotikaspiegel im Blut beeinflussen. rnEine 18-monatige naturalistische klinische Studie an schizophrenen Patienten wurde durchgeführt, um folgende Fragen zu beantworten: Kann man das Therapieansprechen prädizieren und welche Instrumente sind dafür geeignet? Die Psychopathologie wurde anhand zweier Messskalen (Brief Psychiatric Rating Scale, BPRS und Clinical Global Impressions, CGI) wöchentlich ermittelt, um die Besserung der Krankheitssymptome im Verlauf von 8 Wochen zu bewerten. Therapiebegleitend wurden noch die Serum-Konzentrationen der Antipsychotika gemessen. Objektive Symptomerfassung durch BPRS oder CGI waren als Messinstrumente geeignet, Therapieansprechen vorherzusagen. Bezogen auf den Behandlungsbeginn war eine Verminderung der Symptome hoch prädiktiv für späteres Therapieversagen oder -ansprechen. Eine Verminderung um mehr als 36,5% auf der BPRS Skala in Woche 2 wurde als signifikanter Schwellenwert für Nichtansprechen ermittelt. Patienten, deren Symptombesserung unterhalb des Schwellenwertes lag, hatten eine 11,2-fach höhere Wahrscheinlichkeit, am Ende der Studie nicht auf ihre medikamentöse Therapie anzusprechen als die Patienten, die sich um mindestens 36,5% verbesserten. Andere Faktoren, wie Alter, Geschlecht, Dauer der Erkrankung oder Anzahl der stationären Aufenthalte hatten keinen Einfluss auf die Prädiktion des Therapieansprechens. Therapeutische Antipsychotika-Spiegel übten einen positiven Einfluss auf die Ansprechrate aus. Bei Patienten mit therapeutischen Spiegeln war das Ansprechen rascher und die Ansprechrate größer als unter denjenigen deren Spiegel außerhalb der therapeutisch üblichen Bereiche lag. rnEine wichtige Voraussetzung für den Einsatz von TDM ist das Vorhandensein einer präzisen, reproduzierbaren, zeit- und kostensparenden analytischen Methode zur quantitativen Bestimmung der untersuchten Substanzen. Die Entwicklung und Validierung einer solchen geeigneten Methode wurde für den Nachweis von Haloperidol vorgenommen. Eine HPLC-Methode mit Säulenschaltung erwies sich für TDM geeignet. rnBasierend auf den Ergebnissen der eigenen klinischen Studie zur Response Prädiktion wurde untersucht, welche Faktoren die Variabilität der Pharmakokinetik von Antipsychotika beeinflussen. Die Variabilität der Pharmakokinetik ist ein Grund für fehlendes oder unzureichendes Ansprechen. Es wurde zum einen der Einfluss der galenischen Formulierung auf die Freisetzung und zum anderen der Einfluss von entzündlichen Prozessen auf die Metabolisierung eines Antipsychotikums untersucht. Dazu wurden Patientendaten retrospektiv ausgewertet.rnDie Analyse von 247 Serumspiegeln von Patienten, die mit Paliperidon in OROS®Formulierung, einer neu eingeführten Retardform, behandelt wurden, zeigte, dass die intraindividuelle Variabilität der Talspiegel (Vk) von Paliperidon 35% betrug. Er war damit vergleichbar wie für nicht retardiertes Risperidon 32% (p=n.s.). Die Retardierung hatte demnach keinen Varianz mindernden Effekt auf die Talspiegel des Antipsychotikums. Der Wirkstoff-Konzentrations-Bereich lag bei 21-55 ng/ml und entsprach ebenfalls nahezu dem therapeutischen Bereich von Risperidon (20-60 ng/ml). rnEntzündliche Prozesse können die Metabolisierung von Medikamenten verändern. Dies wurde bisher für Medikamente nachgewiesen, die über CYP1A2 abgebaut werden. Durch die eigene Analyse von 84 Patienten-Serumspiegeln konnte festgestellt werden, dass die Metabolisierung von Quetiapin während eines entzündlichen Prozesses beeinträchtigt war, wahrscheinlich durch Hemmung von CYP3A4. Dies sprach dafür, dass auch Wirkstoffe, die über CYP3A4 abgebaut werden, während eines entzündlichen Prozesses im Körper in ihrer Pharmakokinetik beeinträchtigt sein können. Aus diesem Grund sollte während einer Infektion unter der Therapie mit Quetiapin besonders auf die Nebenwirkungen geachtet werden und der Serumspiegel sollte in dieser Zeit überwacht werden, um den Patienten vor eventuellen Nebenwirkungen oder sogar Intoxikationen zu schützen. rnDie Befunde dieser Arbeit zeigen, dass bei einer Behandlung schizophrener Patienten mit Antipsychotika die Messung der Psychopathologie zur Vorhersage des Therapieansprechens und die Messung der Blutspiegel zur Identifizierung von Faktoren, die die pharmakokinetische Variabilität bedingen, geeignet sind. Objektive Symptomerfassung und Therapeutisches Drug Monitoring sind demnach Instrumente, die für die Steuerung der antipsychotischen Pharmakotherapie genutzt werden sollten.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wasserlösliche organische Verbindungen (WSOCs) sind Hauptbestandteile atmosphärischer Aerosole, die bis zu ~ 50% und mehr der organischen Aerosolfraktion ausmachen. Sie können die optischen Eigenschaften sowie die Hygroskopizität von Aerosolpartikeln und damit deren Auswirkungen auf das Klima beeinflussen. Darüber hinaus können sie zur Toxizität und Allergenität atmosphärischer Aerosole beitragen.In dieser Studie wurde Hochleistungsflüssigchromatographie gekoppelt mit optischen Diodenarraydetektion und Massenspektrometrie (HPLC-DAD-MS und HPLC-MS/MS) angewandt, um WSOCs zu analysieren, die für verschiedene Aerosolquellen und -prozesse charakteristisch sind. Niedermolekulare Carbonsäuren und Nitrophenole wurden als Indikatoren für die Verbrennung fossiler Brennstoffe und die Entstehung sowie Alterung sekundärer organischer Aerosole (SOA) aus biogenen Vorläufern untersucht. Protein-Makromoleküle wurden mit Blick auf den Einfluss von Luftverschmutzung und Nitrierungsreaktionen auf die Allergenität primärer biologischer Aerosolpartikel – wie Pollen und Pilzsporen – untersucht.rnFilterproben von Grob- und Feinstaubwurden über ein Jahr hinweg gesammelt und auf folgende WSOCs untersucht: die Pinen-Oxidationsprodukte Pinsäure, Pinonsäure und 3-Methyl-1,2,3-Butantricarbonsäure (3-MBTCA) sowie eine Vielzahl anderer Dicarbonsäuren und Nitrophenole. Saisonale Schwankungen und andere charakteristische Merkmale werden mit Blick auf Aerosolquellen und -senken im Vergleich zu Daten anderen Studien und Regionen diskutiert. Die Verhätlnisse von Adipinsäure und Phthalsäure zu Azelainsäure deuten darauf hin, dass die untersuchten Aerosolproben hauptsächlich durch biogene Quellen beeinflusst werden. Eine ausgeprägte Arrhenius-artige Korrelation wurde zwischen der 3-MBTCA-¬Konzentration und der inversen Temperatur beobachtet (R2 = 0.79, Ea = 126±10 kJ mol-1, Temperaturbereich 275–300 K). Modellrechnungen zeigen, dass die Temperaturabhängigkeit auf eine Steigerung der photochemischen Produktionsraten von 3-MBTCA durch erhöhte OH-Radikal-Konzentrationen bei erhöhten Temperaturen zurückgeführt werden kann. Im Vergleich zur chemischen Reaktionskinetik scheint der Einfluss von Gas-Partikel-Partitionierungseffekten nur eine untergeordnete Rolle zu spielen. Die Ergebnisse zeigen, dass die OH-initiierte Oxidation von Pinosäure der geschwindigkeitsbestimmende Schritt der Bildung von 3-MBTCA ist. 3-MBTCA erscheint somit als Indikator für die chemische Alterung von biogener sekundärer organischer Aerosole (SOA) durch OH-Radikale geeignet. Eine Arrhenius-artige Temperaturabhängigkeit wurde auch für Pinäure beobachtet und kann durch die Temperaturabhängigkeit der biogenen Pinen-Emissionen als geschwindigkeitsbestimmender Schritt der Pinsäure-Bildung erklärt werden (R2 = 0.60, Ea = 84±9 kJ mol-1).rn rnFür die Untersuchung von Proteinnitrierungreaktionen wurde nitrierte Protein¬standards durch Flüssigphasenreaktion von Rinderserumalbumin (BSA) und Ovalbumin (OVA) mit Tetranitromethan (TNM) synthetisiert.Proteinnitrierung erfolgt vorrangig an den Resten der aromatischen Aminosäure Tyrosin auf, und mittels UV-Vis-Photometrie wurde der Proteinnnitrierungsgrad (ND) bestimmt. Dieser ist definiert als Verhältnis der mittleren Anzahl von Nitrotyrosinresten zur Tyrosinrest-Gesamtzahl in den Proteinmolekülen. BSA und OVA zeigten verschiedene Relationen zwischen ND und TNM/Tyrosin-Verhältnis im Reaktionsgemisch, was vermutlich auf Unterschiede in den Löslichkeiten und den molekularen Strukturen der beiden Proteine zurück zu führen ist.rnDie Nitrierung von BSA und OVA durch Exposition mit einem Gasgemisch aus Stickstoffdioxid (NO2) und Ozon (O3) wurde mit einer neu entwickelten HPLC-DAD-¬Analysemethode untersucht. Diese einfache und robuste Methode erlaubt die Bestimmung des ND ohne Hydrolyse oder Verdau der untersuchten Proteine und ernöglicht somit eine effiziente Untersuchung der Kinetik von Protein¬nitrierungs-Reaktionen. Für eine detaillierte Produktstudien wurden die nitrierten Proteine enzymatisch verdaut, und die erhaltenen Oligopeptide wurden mittels HPLC-MS/MS und Datenbankabgleich mit hoher Sequenzübereinstimmung analysiert. Die Nitrierungsgrade individueller Nitrotyrosin-Reste (NDY) korrelierten gut mit dem Gesamt-Proteinnitrierungsgrad (ND), und unterschiedliche Verhältnisse von NDY zu ND geben Aufschluss über die Regioselektivität der Reaktion. Die Nitrierungmuster von BSA und OVA nach Beahndlung mit TNM deuten darauf hin, dass die Nachbarschaft eines negativ geladenen Aminosäurerestes die Tyrosinnitrierung fördert. Die Behandlung von BSA durch NO2 und O3 führte zu anderend Nitrierungemustern als die Behandlung mit TNM, was darauf hindeutet, dass die Regioselektivität der Nitrierung vom Nitrierungsmittel abhängt. Es zeigt sich jedoch, dass Tyrosinreste in Loop-Strukturen bevorzugt und unabhängig vom Reagens nitriert werden.Die Methoden und Ergebnisse dieser Studie bilden eine Grundlage für weitere, detaillierte Untersuchungen der Reaktionskinetik sowie der Produkte und Mechanismen von Proteinnitrierungreaktionen. Sie sollen helfen, die Zusammenhänge zwischen verkehrsbedingten Luftschadstoffen wie Stickoxiden und Ozon und der Allergenität von Luftstaub aufzuklären.rn