26 resultados para double source electron beam evaporation technology

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wurde die paritätsverletzende Asymmetrie in derrnquasielastischen Elektron-Deuteron-Streuung bei Q^2=0.23 (GeV/c)^2 mitrneinem longitudinal polarisierten Elektronstrahl bei einer Energie von 315rnMeV bestimmt. Die Messung erfolgte unter Rückwärtswinkeln. Der Detektor überdeckte einen polaren Streuwinkelbereichrnzwischen 140 und 150 deg. Das Target bestand aus flüssigemrnDeuterium in einer Targetzelle mit einer Länge von 23.4 cm. Dierngemessene paritätsverletzende Asymmetrie beträgt A_{PV}^d = (-20.11 pm 0.87_{stat} pm 1.03_{syst}), wobei der erste Fehler den statistischenrnFehlereitrag und der zweite den systematischen Fehlerbeitrag beschreibt. Ausrnder Kombination dieser Messung mit Messungen der paritätsverletzendenrnAsymmetrie in der elastischen Elektron-Proton-Streuung bei gleichem Q^2rnsowohl bei Vorwärts- als auch bei Rückwärtsmessungen können diernVektor-Strange-Formfaktoren sowie der effektive isovektorielle und isoskalarernVektorstrom des Protons, der die elektroschwachen radiativen Anapolkorrekturenrnenthält, bestimmt werden. Diese Arbeit umfasst ausserdem die Bestimmungrnder Asymmetrien bei einem transversal polarisierten Elektronstrahl sowohl beirneinem Proton- als auch einem Deuterontarget unter Rückwärtswinkeln beirnImpulsüberträgen von Q^2=0.10 (GeV/c)^2, Q^2=0.23 (GeV/c)^2rnund Q^2=0.35 (GeV/c)^2. Die im Experiment beobachteten Asymmetrien werdenrnmit theoretischen Berechnungen verglichen, welche den Imaginärteil der Zweiphoton-Austauschamplitude beinhalten.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to its high Curie temperature of 420K and band structure calculations predicting 100% spin polarisation, Sr2FeMoO6 is a potential candidate for spintronic devices. However, the preparation of good quality thin films has proven to be a non-trivial task. Epitaxial Sr2FeMoO6 thin films were prepared by pulsed laser deposition on different substrates. Differing from previous reports a post-deposition annealing step at low oxygen partial pressure (10-5 mbar) was introduced and enabled the fabrication of reproducible, high quality samples. According to the structural properties of the substrates the crystal structure and morphology of the thin films are modified. The close interrelation between the structural, magnetic and electronic properties of Sr2FeMoO6 was studied. A detailed evaluation of the results allowed to extract valuable information on the microscopic nature of magnetism and charge transport. Smooth films with a mean roughness of about 2 nm have been achieved, which is a pre-requisite for a possible inclusion of this material in future devices. In order to establish device-oriented sub-micron patterning as a standard technique, electron beam lithography and focussed ion beam etching facilities have been put into operation. A detailed characterisation of these systems has been performed. To determine the technological prospects of new spintronics materials, the verification of a high spin polarisation is of vital interest. A popular technique for this task is point contact Andreev reflection (PCAR). Commonly, the charge transport in a transparent metal-superconductor contact of nanometer dimensions is attributed solely to coherent transport. If this condition is not fulfilled, inelastic processes in the constriction have to be considered. PCAR has been applied to Sr2FeMoO6 and the Heusler compound Co2Cr0.6Fe0.4Al. Systematic deviations between measured spectra and the standard models of PCAR have been observed. Therefore existing approaches have been generalised, in order to include the influence of heating. With the extended model the measured data was successfully reproduced but the analysis has revealed grave implications for the determination of spin polarisation, which was found to break down completely in certain cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gegenstand dieser Arbeit ist die Untersuchung von Photokathoden mit negativer Elektronenaffinität (NEA) mittels zeitlich hochauflösender Vermessung der emittierten Ladungs- und Spinpolarisationsverteilungen nach Anregung mit einem ultrakurzen Laserpuls. Untersucht wurden uniaxial deformierte GaAsP-Photokathoden mit dünnen emittierenden Schichten (≤150nm), sowie undeformierte GaAs-Photokathoden mit unterschiedlichen Schichtdicken. Die Untersuchungen wurden an einer 100keV-Elektronenquelle durchgeführt, wie sie am Mainzer Mikrotron (MAMI) zur Erzeugung eines Spinpolarisierten Elektronenstrahls verwendet wird. Mit der Apparatur konnte eine Zeitauflösung von 2,5ps erreicht werden. Es zeigte sich, dass die tatsächliche Antwortzeit der Photokathoden die erreichte Zeitauflösung noch unterschreitet. Eine Depolarisation in den kurzen, wegen der Zeitauflösung auf 2,5ps begrenzten, Elektronenpulsen konnte aber nachgewiesen werden. Weiterhin wurde gezeigt, dass der Polarisationsverlust der emittierten Elektronen bei dünnen Schichten im Wesentlichen auf eine energiekorrelierte Depolarisation beim Durchqueren der Bandbiegungszone zurückzuführen ist. Als weiteres Resultat wird, für die GaAsP-Photokathoden mit einer Schichtdicke von 150nm, eine Obergrenze für die mittlere Emissionszeit von ≤1,25ps angegeben. Daraus ergibt sich nach dem hier verwendeten Diffusionsmodell eine Untergrenze für die Oberflächenrekombinationsgeschwindigkeit an der Bandbiegungszone von S≥1,2·10^7 cm/s.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Produktion eines spinpolarisierten Strahls mit hohem mittleren Strom ist sowohl für den Betrieb von existierenden polarisierten Quellen als auch in noch stärkerem Maße für geplante zukünftige Projekte wichtig. Die Betriebszeit solcher Quellen wird durch die Abnahme der Quantenausbeute der Photokathode mit der Zeit begrenzt. Die Problematik der Abnahme der Quantenausbeute konnte durch die Reaktion der Kathodenoberfläche mit sauerstoffhaltigen Molekülen sowie durch Ionenbombardement geklärt werden. Im Laufe dieser Arbeit wurden, teilweise zum ersten Mal, Mechanismen untersucht, die zur Entstehung der chemisch aktiven Moleküle und der Ionen beitragen und weitere Effekte, die die Betriebszeit der polarisierten Quellen reduzieren. Die Experimente wurden an einer genauen Kopie der an MAMI vorhandenen polarisierten Quelle durchgeführt. Es wurde demonstriert, dass Erwärmung der Photokathode, Ioneneinfang und Strahlverlust aufgrund der Raumladungskräfte die Kathodenlebensdauer begrenzen können. Der erste Effekt ist Erwärmung der Photokathode. Die Laserleistung wird fast vollständig in Wärmeleistung umgesetzt, was zur Absenkung der Verfügbarkeit der polarisierten Quellen führen kann, und zwar unabhängig davon, ob der Photostrom produziert wird oder nicht. Der zweite Effekt ist Ionenbombardement mit den sowohl in der Beschleunigungsstrecke als auch in der Strahlführung entstehenden Ionen. Es wurde demonstriert, dass der in der Strahlführung entstehende Ionenstrom sogar größer ist als der in der Kanone. Unter bestimmten Bedingungen können die gebildeten Ionen durch das Potenzial des Elektronenstrahls eingefangen werden und die Kanone erreichen und damit zusätzlich zur Zerstörung der negativen Elektronenaffinität beitragen. Der dritte Effekt ist Strahlverlust. Es wurde demonstriert, dass die relativen Strahlverluste kleiner als 1*10-6 sein sollten, um eine Lebensdauer von mehr als 1000 Stunden beim Strom von 100 A zu erreichen, was für die vorhandene Apparatur möglich ist. Zur Erzeugung extrem hoher Ströme wurde zum ersten Mal im Bereich der spinpolarisierten Quellen das Prinzip der „Energierückgewinnung“ eingesetzt. Experimente bei einer mittleren Stromstärke von 11.4 mA und einer Spitzenstromstärke von 57 mA bei 1% Tastverhältnis wurden bereits durchgeführt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work, the formation and migration of point defects induced by electron irradiation in carbon nanostructures, including carbon onions, nanotubes and graphene layers, were investigated by in-situ TEM. The mobility of carbon atoms normal to the layers in graphitic nanoparticles, the mobility of carbon interstitials inside SWCNTs, and the migration of foreign atoms in graphene layers or in layers of carbon nanotubes were studied. The diffusion of carbon atoms in carbon onions was investigated by annealing carbon onions and observing the relaxation of the compressed clusters in the temperature range of 1200 – 2000oC. An activation energy of 5.0±0.3 eV was obtained. This rather high activation energy for atom exchange between the layers not only prevents the exchange of carbon atoms between the layers at lower temperature but also explains the high morphological and mechanical stability of graphite nanostructures. The migration of carbon atoms in SWCNTs was investigated quantitatively by cutting SWCNT bundles repeatedly with a focused electron beam at different temperatures. A migration barrier of about 0.25 eV was obtained for the diffusion of carbon atoms inside SWCNTs. This is an experimental confirmation of the high mobility of interstitial atoms inside carbon nanotubes, which corroborates previously developed theoretical models of interstitial diffusivity. Individual Au and Pt atoms in one- or two-layered graphene planes and MWCNTs were monitored in real time at high temperatures by high-resolution TEM. The direct observation of the behavior of Au and Pt atoms in graphenic structures in a temperature range of 600 – 700°C allows us to determine the sites occupied by the metal atoms in the graphene layer and the diffusivities of the metal atoms. It was found that metal atoms were located in single or multiple carbon vacancies, not in off-plane positions, and diffused by site exchange with carbon atoms. Metal atoms showed a tendency to form clusters those were stable for a few seconds. An activation energy of around 2.5 eV was obtained for the in-plane migration of both Au and Pt atoms in graphene (two-dimensional diffusion). The rather high activation energy indicates covalent bonding between metal and carbon atoms. Metal atoms were also observed to diffuse along the open edge of graphene layers (one-dimensional diffusion) with a slightly lower activation energy of about 2.3 eV. It is also found that the diffusion of metal atoms in curved graphenic layers of MWCNTs is slightly faster than in planar graphene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mit der Erweiterung des Elektronenbeschleunigers MAMI um eine dritte Stufe ist es möglich geworden, am Institut für Kernphysik Teilchen mit offener Strangeness zu produzieren. Für deren Nachweis ist die Drei-Spektrometeranlage der Kollaboration A1 um das von der GSI in Darmstadt übernommene KAOS-Spektrometer erweitert worden. Untersucht wird damit die elementare Reaktion p(e,e' K+)Lambda/Sigma0 wobei das auslaufende Elektron und das Kaon nachgewiesen werden müssen. Wird als Target nicht Wasserstoff verwendet, besteht die Möglichkeit dass sich ein Hyperkern bildet. Spektroskopische Untersuchungen an diesen bieten die Möglichkeit das Potential von Hyperonen in Atomkernen und die Hyperon-Nukleon-Wechselwirkung zu untersuchen. Aufgrund der hervorragenden Strahlqualität bei der Elektroproduktion können hier Massenauflösungen von einigen hundert keV/c² erreicht werden. Mit Hilfe von GEANT4 wurden die Detektoren und die Abbildungseigenschaften des Spektrometers simuliert. Geeignete Ereignisgeneratoren wurden implementiert. Es wurde untersucht, wie mögliche Treffermuster in den Detektoren aussehen, die von einem Trigger auf FPGA-Basis selektiert werden müssen. Ebenso konnte hieraus eine erste Abbildung der Spurkoordinaten auf die Targetkoordinaten und den Teilchenimpuls gewonnen werden. Für das Hyperkernprogramm muss KAOS unter 0° Vorwärtsrichung betrieben werden und der Primärstrahl mit Hilfe einer Schikane durch den Dipol gelenkt werden. Die Simulation zeigt hier eine nur moderate Erhöhung der Strahlenbelastung, vor allem im Bereich des Strahlfängers. Somit ist es möglich, KAOS als doppelseitiges Spektrometer in der Spektrometerhalle zu betreiben. Im Rahmen dieser Arbeit wurden die für sämtliche Detektoren nötige Auslese- und Steuerungselektronik in das vorhandene Datenerfassungssystem und das Steuerungssystem eingebunden. In zwei Strahlzeiten im Herbst 2008 wurden Kaonen im Winkelbereich von 20°-40° mit Impulsen zwischen 400MeV/c und 600MeV/c nachgewiesen. Die aus der Simulation gewonnenen Daten zum Trigger und zur Abbildung kamen zum Einsatz. Es konnte die für eine gute Teilchenidentifikation nötige Zeitauflösung von ca. 1ns FWHM erreicht werden. Die erreichte Winkel- und Impulsauflösung war ausreichend um Lambda und Sigma0-Hyperonen im Spektrum der fehlenden Masse leicht trennen zu können.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis presents a new imaging technique for ultracold quantum gases. Since the first observation of Bose-Einstein condensation, ultracold atoms have proven to be an interesting system to study fundamental quantum effects in many-body systems. Most of the experiments use optical imaging rnmethods to extract the information from the system and are therefore restricted to the fundamental limitation of this technique: the best achievable spatial resolution that can be achieved is comparable to the wavelength of the employed light field. Since the average atomic distance and the length scale of characteristic spatial structures in Bose-Einstein condensates such as vortices and solitons is between 100 nm and 500 nm, an imaging technique with an adequate spatial resolution is needed. This is achieved in this work by extending the method of scanning electron microscopy to ultracold quantum gases. A focused electron beam is scanned over the atom cloud and locally produces ions which are subsequently detected. The new imaging technique allows for the precise measurement of the density distribution of a trapped Bose-Einstein condensate. Furthermore, the spatial resolution is determined by imaging the atomic distribution in one-dimensional and two-dimensional optical lattices. Finally, the variety of the imaging method is demonstrated by the selective removal of single lattice site. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit werden der experimentelle Aufbau und erste Messungen für die Bestimmung des g-Faktors des Elektrons gebunden in wasserstoff- und lithiumähnlichen mittelschweren Ionen beschrieben. Mit dem hochpräzisenWert des g-Faktors können theoretische Berechnungen der Quantenelektrodynamik gebundener Zustände überprüft werden. Die Messungen werden in einem Dreifach-Penningfallen-System durchgeführt. Dort wurden im Rahmen dieser Arbeit auch erstmals hochgeladene Ionen bis 28Si13+ in einer hierfür entwickelten Elektronenstrahl-Ionenquelle/-falle erzeugt. Für die Bestimmung des g-Faktors werden die freie Zyklotronfrequenz und die Larmorfrequenz benötigt. Erstere wird aus den drei Eigenfrequenzen des in der Präzisionsfalle gespeicherten Ions berechnet. Um das Ion bei den Messungen nicht zu verlieren, werden die Eigenfrequenzen des Ions durch Kopplung an einen radiofrequenten Nachweisschwingkreis nicht-destruktiv nachgewiesen. Die freie Zyklotronfrequenz konnte dabei mit einer relativen Genauigkeit von wenigen 10E−9 bestimmt werden. Zur Bestimmung der Larmorfrequenz ist die genaue Kenntnis der Spinrichtung des Elektrons im Magnetfeld notwendig. Diese wird durch den kontinuierlichen Stern-Gerlach-Effekt in der sogenannten Analysefalle bestimmt. Hierzu muss eine hohe Stabilität der axialen Frequenz des Ions erreicht werden. Um dies sowie die Hochpräzisionsmessungen in der Präzisionsfalle zu erreichen, wurden in dieser Arbeit beide Fallen hinsichtlich ihrer elektrischen und magnetischen Eigenschaften charakterisiert.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Elektronen in wasserstoff- und lithium-ähnlichen schweren Ionen sind den extrem starken elektrischen und magnetischen Feldern in der Umgebung des Kerns ausgesetzt. Die Laserspektroskopie der Hyperfeinaufspaltung im Grundzustand des Ions erlaubt daher einen sensitiven Test der Quantenelektrodynamik in starken Feldern insbesondere im magnetischen Sektor. Frühere Messungen an wasserstoffähnlichen Systemen die an einer Elektronenstrahl-Ionenfalle (EBIT) und am Experimentierspeicherring (ESR) der GSI Darmstadt durchgeführt wurden, waren in ihrer Genauigkeit durch zu geringe Statistik, einer starken Dopplerverbreiterung und der großen Unsicherheit in der Ionenenergie limitiert. Das ganze Potential des QED-Tests kann nur dann ausgeschöpft werden, wenn es gelingt sowohl wasserstoff- als auch lithium-ähnliche schwere Ionen mit einer um 2-3 Größenordnung gesteigerten Genauigkeit zu spektroskopieren. Um dies zu erreichen, wird gegenwärtig das neue Penningfallensystem SPECTRAP an der GSI aufgebaut und in Betrieb genommen. Es ist speziell für die Laserspektroskopie an gespeicherten hochgeladenen Ionen optimiert und wird in Zukunft von HITRAP mit nierderenergetischen hochgeladenen Ionen versorgt werden.rnrnSPECTRAP ist eine zylindrische Penningfalle mit axialem Zugang für die Injektion von Ionen und die Einkopplung eines Laserstrahls sowie einem radialen optischen Zugang für die Detektion der Fluoreszenz. Um letzteres zu realisieren ist der supraleitende Magnet als Helmholtz-Spulenpaar ausgelegt. Um die gewünschte Genauigkeit bei der Laserspektroskopie zu erreichen, muss ein effizienter und schneller Kühlprozess für die injizierten hochegeladenen Ionen realisiert werden. Dies kann mittels sympathetischer Kühlung in einer lasergekühlten Wolke leichter Ionen realisiert werden. Im Rahmen dieser Arbeit wurde ein Lasersystem und eine Ionenquelle für die Produktion einer solchen 24Mg+ Ionenwolke aufgebaut und erfolgreich an SPECTRAP in Betrieb genommen. Dazu wurde ein Festkörperlasersystem für die Erzeugung von Licht bei 279.6 nm entworfen und aufgebaut. Es besteht aus einem Faserlaser bei 1118 nm der in zwei aufeinanderfolgenden Frequenzverdopplungsstufen frequenzvervierfacht wird. Die Verdopplerstufen sind als aktiv stabilisierte Resonantoren mit nichtlinearen Kristallen ausgelegt. Das Lasersystem liefert unter optimalen Bedingeungen bis zu 15 mW bei der ultravioletten Wellenlänge und erwies sich während der Teststrahlzeiten an SPECTRAP als ausgesprochen zuverlässig. Desweiteren wurde eine Ionequelle für die gepulste Injektion von Mg+ Ionen in die SPECTRAP Falle entwickelt. Diese basiert auf der Elektronenstoßionisation eines thermischen Mg-Atomstrahls und liefert in der gepulsten Extraktion Ionenbündel mit einer kleinen Impuls- und Energieverteilung. Unter Nutzung des Lasersystems konnten damit an SPECTRAP erstmals Ionenwolken mit bis zu 2600 lasergekühlten Mg Ionen erzeugt werden. Der Nachweis erfolgte sowohl mittels Fluoreszenz als auch mit der FFT-ICR Technik. Aus der Analyse des Fluoreszenz-Linienprofils lässt sich sowohl die Sensitivität auf einzelne gespeicherte Ionen als auch eine erreichte Endtemperatur in der Größenordnung von ≈ 100 mK nach wenigen Sekunden Kühlzeit belegen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Institut für Kernphysik der Universität Mainz betreibt seit 1990 eine weltweit einzigartige Beschleunigeranlage für kern- und teilchenphysikalische Experimente – das Mainzer Mikrotron (MAMI-B). Diese Beschleunigerkaskade besteht aus drei Rennbahn-Mikrotrons (RTMs) mit Hochfrequenzlinearbeschleunigern bei 2.45 GHz, mit denen ein quasi kontinuierlicher Elektronenstrahl von bis zu 100 μA auf 855MeV beschleunigt werden kann.rnrnIm Jahr 1999 wurde die Umsetzung der letzten Ausbaustufe – ein Harmonisches Doppelseitiges Mikrotron (HDSM, MAMI-C) – mit einer Endenergie von 1.5 GeV begonnen. Die Planung erforderte einige mutige Schritte, z.B. Umlenkmagnete mit Feldgradient und ihren daraus resultierenden strahloptischen Eigenschaften, die einen großen Einfluss auf die Longitudinaldynamik des Beschleunigers haben. Dies erforderte die Einführung der „harmonischen“ Betriebsweise mit zwei Frequenzen der zwei Linearbeschleuniger.rnrnViele Maschinenparameter (wie z.B. HF-Amplituden oder -Phasen) wirken direkt auf den Beschleunigungsprozess ein, ihre physikalischen Größen sind indes nicht immer auf einfache Weise messtechnisch zugänglich. Bei einem RTM mit einer verhältnismäßig einfachen und wohldefinierten Strahldynamik ist das im Routinebetrieb unproblematisch, beim HDSM hingegen ist schon allein wegen der größeren Zahl an Parametern die Kenntnis der physikalischen Größen von deutlich größerer Bedeutung. Es gelang im Rahmen dieser Arbeit, geeignete Methoden der Strahldiagnose zu entwickeln, mit denen diese Maschinenparameter überprüft und mit den Planungsvorgaben verglichen werden können.rnrnDa die Anpassung des Maschinenmodells an eine einzelne Phasenmessung aufgrund der unvermeidlichen Messfehler nicht immer eindeutige Ergebnisse liefert, wird eine Form der Tomographie verwendet. Der longitudinale Phasenraum wird dann in Form einer Akzeptanzmessung untersucht. Anschließend kann ein erweitertes Modell an die gewonnene Datenvielfalt angepasst werden, wodurch eine größere Signifikanz der Modellparameter erreicht wird.rnrnDie Ergebnisse dieser Untersuchungen zeigen, dass sich der Beschleuniger als Gesamtsystem im Wesentlichen wie vorhergesagt verhält und eine große Zahl unterschiedlicher Konfigurationen zum Strahlbetrieb möglich sind – im Routinebetrieb wird dies jedoch vermieden und eine bewährte Konfiguration für die meisten Situationen eingesetzt. Das führt zu einer guten Reproduzierbarkeit z.B. der Endenergie oder des Spinpolarisationswinkels an den Experimentierplätzen.rnrnDie Erkenntnisse aus diesen Untersuchungen wurden teilweise automatisiert, so dass nun den Operateuren zusätzliche und hilfreiche Diagnose zur Verfügung steht, mit denen der Maschinenbetrieb noch zuverlässiger durchgeführt werden kann.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structure characterization of nanocrystalline intermediates and metastable phases is of primary importance for a deep understanding of synthetic processes undergoing solid-to-solid state phase transitions. Understanding the evolution from the first nucleation stage to the final synthetic product supports not only the optimization of existing processes, but might assist in tailoring new synthetic paths. A systematic investigation of intermediates and metastable phases is hampered because it is impossible to produce large crystals and only in few cases a pure synthetic product can be obtained. Structure investigation by X-ray powder diffraction methods is still challenging on nanoscale, especially when the sample is polyphasic. Electron diffraction has the advantage to collect data from single nanoscopic crystals, but is limited by data incompleteness, dynamical effects and fast deterioration of the sample under the electron beam. Automated diffraction tomography (ADT), a recently developed technique, making possible to collect more complete three-dimensional electron diffraction data and to reduce at the same time dynamical scattering and beam damage, thus allowing to investigate even beam sensitive materials (f.e. hydrated phases and organics). At present, ADT is the only technique able to deliver complete three-dimensional structural information from single nanoscopic grains, independently from other surrounding phases. Thus, ADT is an ideal technique for the study of on-going processes where different phases exist at the same time and undergo several structural transitions. In this study ADT was used as the main technique for structural characterization for three different systems and combined subsequently with other techniques, among which high-resolution transmission electron microscopy (HRTEM), cryo-TEM imaging, X-ray powder diffraction (XRPD) and energy disperse X-ray spectroscopy (EDX).rnAs possible laser host materials, i.e. materials with a broad band emission in the near-infrared region, two unknown phases were investigated in the ternary oxide system M2O-Al2O3-WO3 (M = K, Na). Both phases exhibit low purity as well as non-homogeneous size distribution and particle morphology. The structures solved by ADT are also affected by pseudo-symmetry. rnSodium titanate nanotubes and nanowires are both intermediate products in the synthesis of TiO2 nanorods which are used as additives to colloidal TiO2 film for improving efficiency of dye-sensitized solar cells (DSSC). The structural transition from nantubes to nanowires was investigated in a step by step time-resolved study. Nanowires were discovered to consist of a hitherto unknown phase of sodium titanate. This new phase, typically affected by pervasive defects like mutual layer shift, was structurally determined ab-initio on the basis of ADT data. rnThe third system is related with calcium carbonate nucleation and early crystallization. The first part of this study is dedicated to the extensive investigations of calcium carbonate formation in a step by step analysis, up to the appearance of crystalline individua. The second part is dedicated to the structure determination by ADT of the first-to-form anhydrated phase of CaCO3: vaterite. An exhaustive structure analysis of vaterite had previously been hampered by diffuse scattering, extra periodicities and fast deterioration of the material under electron irradiation. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental investigations of visible Smith-Purcell-radiation with a micro-focused high relativistic electron beam (E=855 MeV) are presented in the near region, in which the electron beam grazes the surface of the grating. The radiation intensity was measured as a function of the angle of observation and of the distance between electron beam axis and the surface of the grating simultaneously for two different wavelengths (360 nm, 546 nm).In the experiments Smith-Purcell-radiation was identified by the measured angular distribution fulfilling the characteristic coherence condition. By the observed distance dependence of the intensity two components of Smith-Purcell-radiation could be separated: one component with the theoretical predicted interaction length hint, which is produced by electrons passing over the surface of the grating, and an additional component in the near region leading to a strong enhancement of the intensity, which is produced by electrons hitting the surface. To describe the intensity of the observed additional radiation component a simple model for optical grating transition radiation, caused by the electrons passing through the grating structure, is presented. Taking into account the simple scalar model, the results of a Monte-Carlo calculation show that the additional radiation component could be explained by optical grating transition radiation.