2 resultados para SENSITIVE DETERMINATION
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
It has been demonstrated that iodine does have an important influence on atmospheric chemistry, especially the formation of new particles and the enrichment of iodine in marine aerosols. It was pointed out that the most probable chemical species involved in the production or growth of these particles are iodine oxides, produced photochemically from biogenic halocarbon emissions and/or iodine emission from the sea surface. However, the iodine chemistry from gaseous to particulate phase in the coastal atmosphere and the chemical nature of the condensing iodine species are still not understood. A Tenax / Carbotrap adsorption sampling technique and a thermo-desorption / cryo-trap / GC-MS system has been further developed and improved for the volatile organic iodine species in the gas phase. Several iodo-hydrocarbons such as CH3I, C2H5I, CH2ICl, CH2IBr and CH2I2 etc., have been measured in samples from a calibration test gas source (standards), real air samples and samples from seaweeds / macro-algae emission experiments. A denuder sampling technique has been developed to characterise potential precursor compounds of coastal particle formation processes, such as molecular iodine in the gas phase. Starch, TMAH (TetraMethylAmmonium Hydroxide) and TBAH (TetraButylAmmonium Hydroxide) coated denuders were tested for their efficiencies to collect I2 at the inner surface, followed by a TMAH extraction and ICP/MS determination, adding tellurium as an internal standard. The developed method has been proved to be an effective, accurate and suitable process for I2 measurement in the field, with the estimated detection limit of ~0.10 ng∙L-1 for a sampling volume of 15 L. An H2O/TMAH-Extraction-ICP/MS method has been developed for the accurate and sensitive determination of iodine species in tropospheric aerosol particles. The particle samples were collected on cellulose-nitrate filters using conventional filter holders or on cellulose nitrate/tedlar-foils using a 5-stage Berner impactor for size-segregated particle analysis. The water soluble species as IO3- and I- were separated by anion exchanging process after water extraction. Non-water soluble species including iodine oxide and organic iodine were digested and extracted by TMAH. Afterwards the triple samples were analysed by ICP/MS. The detection limit for particulate iodine was determined to be 0.10~0.20 ng•m-3 for sampling volumes of 40~100 m3. The developed methods have been used in two field measurements in May 2002 and September 2003, at and around the Mace Head Atmospheric Research Station (MHARS) located at the west coast of Ireland. Elemental iodine as a precursor of the iodine chemistry in the coastal atmosphere, was determined in the gas phase at a seaweed hot-spot around the MHARS, showing I2 concentrations were in the range of 0~1.6 ng∙L-1 and indicating a positive correlation with the ozone concentration. A seaweed-chamber experiment performed at the field measurement station showed that the I2 emission rate from macro-algae was in the range of 0.019~0.022 ng•min-1•kg-1. During these experiments, nanometer-particle concentrations were obtained from the Scanning Mobility Particle Sizer (SMPS) measurements. Particle number concentrations were found to have a linear correlation with elemental iodine in the gas phase of the seaweeds chamber, showing that gaseous I2 is one of the important precursors of the new particle formation in the coastal atmosphere. Iodine contents in the particle phase were measured in both field campaigns at and around the field measurement station. Total iodine concentrations were found to be in the range of 1.0 ~ 21.0 ng∙m-3 in the PM2.5 samples. A significant correlation between the total iodine concentrations and the nanometer-particle number concentrations was observed. The particulate iodine species analysis indicated that iodide contents are usually higher than those of iodate in all samples, with ratios in the range of 2~5:1. It is possible that those water soluble iodine species are transferred through the sea-air interface into the particle phase. The ratio of water soluble (iodate + iodide) and non-water soluble species (probably iodine oxide and organic iodine compounds) was observed to be in the range of 1:1 to 1:2. It appears that higher concentrated non-water soluble species, as the products of the photolysis from the gas phase into the particle phase, can be obtained in those samples while the nucleation events occur. That supports the idea that iodine chemistry in the coastal boundary layer is linked with new particle formation events. Furthermore, artificial aerosol particles were formed from gaseous iodine sources (e.g. CH2I2) using a laboratory reaction-chamber experiment, in which the reaction constant of the CH2I2 photolysis was calculated to be based upon the first order reaction kinetic. The end products of iodine chemistry in the particle phase were identified and quantified.
Resumo:
An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.