3 resultados para Retrial Inventory with BMAP and Servicc Time,
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
In this treatise we consider finite systems of branching particles where the particles move independently of each other according to d-dimensional diffusions. Particles are killed at a position dependent rate, leaving at their death position a random number of descendants according to a position dependent reproduction law. In addition particles immigrate at constant rate (one immigrant per immigration time). A process with above properties is called a branching diffusion withimmigration (BDI). In the first part we present the model in detail and discuss the properties of the BDI under our basic assumptions. In the second part we consider the problem of reconstruction of the trajectory of a BDI from discrete observations. We observe positions of the particles at discrete times; in particular we assume that we have no information about the pedigree of the particles. A natural question arises if we want to apply statistical procedures on the discrete observations: How can we find couples of particle positions which belong to the same particle? We give an easy to implement 'reconstruction scheme' which allows us to redraw or 'reconstruct' parts of the trajectory of the BDI with high accuracy. Moreover asymptotically the whole path can be reconstructed. Further we present simulations which show that our partial reconstruction rule is tractable in practice. In the third part we study how the partial reconstruction rule fits into statistical applications. As an extensive example we present a nonparametric estimator for the diffusion coefficient of a BDI where the particles move according to one-dimensional diffusions. This estimator is based on the Nadaraya-Watson estimator for the diffusion coefficient of one-dimensional diffusions and it uses the partial reconstruction rule developed in the second part above. We are able to prove a rate of convergence of this estimator and finally we present simulations which show that the estimator works well even if we leave our set of assumptions.
Resumo:
Der Einsatz von Penningfallen in der Massenspektrometrie hat zu einem einmaligen Genauigkeitssprung geführt. Dadurch wurden Massenwerte verschiedenster Atome zu wichtigen Eingangsparametern bei immer mehr physikalischen Fragestellungen. Die Massenspektrometrie mit Hilfe von Penningfallen basiert auf der Bestimmung der freien Zyklotronfrequenz eines Ions in einem homogenen Magnetfeld νc=qB/(2πm). Sie wird mit Flugzeitmethode (TOF-ICR) bestimmt, wobei eine relative Massenungenauigkeit δm/m von wenigen 10^-9 bei Nukliden mit Lebensdauern von <500 ms erreicht wird. Dies wurde durch die im Rahmen dieser Arbeit erstmals in der Penningfallen-Massenspektrometrie eingesetzten Ramsey-Methode möglich. Dabei werden zeitlich separierte, oszillierenden Feldern zur resonanten Ionenanregung genutzt, um die Frequenzmessung durch die Flugzeitmethode zu verbessern. Damit wurden am Penningfallenmassenspektrometer ISOLTRAP an ISOLDE/CERN die Massen der Nuklide 26,27Al und 38,39Ca bestimmt. Alle Massen wurden in die „Atomic Mass Evaluation“ eingebettet. Die Massenwerte von 26Al und 38Ca dienten insbesondere zu Tests des Standardmodells. Um mit Massenwerten fundamentale Symmetrien oder die Quantenelektrodynamik (QED) in extremen Feldern zu testen wurde ein neues Penningfallenprojekt (PENTATRAP) für hochpräzise Massenmessungen an hochgeladenen Ionen konzipiert. In dieser Doktorarbeit wurde vornehmlich die Entwicklung der Penningfallen betrieben. Eine Neuerung bei Penningfallenexperimenten ist dabei die permanente Beobachtung des Magnetfeldes B und seiner zeitlichen Fluktuationen durch so genannte „Monitorfallen“.
Resumo:
The behaviour of a polymer depends strongly on the length- and time scale as well as on the temperature rnat which it is probed. In this work, I describe investigations of polymer surfaces using scanning probe rnmicroscopy with heatable probes. With these probes, surfaces can be heated within seconds down to rnmicroseconds. I introduce experiments for the local and fast determination of glass transition and melting rntemperatures. I developed a method which allows the determination of glass transition and melting rntemperatures on films with thicknesses below 100 nm: A background measurement on the substrate was rnperformed. The resulting curve was subtracted from the measurement on the polymer film. The rndifferential measurement on polystyrene films with thicknesses between 35 nm and 160 nm showed rncharacteristic signals at 95 ± 1 °C, in accordance with the glass transition of polystyrene. Pressing heated rnprobes into polymer films causes plastic deformation. Nanometer sized deformations are currently rninvestigated in novel concepts for high density data storage. A suitable medium for such a storage system rnhas to be easily indentable on one hand, but on the other hand it also has to be very stable towards rnsurface induced wear. For developing such a medium I investigated a new approach: A comparably soft rnmaterial, namely polystyrene, was protected with a thin but very hard layer made of plasma polymerized rnnorbornene. The resulting bilayered media were tested for surface stability and deformability. I showed rnthat the bilayered material combines the deformability of polystyrene with the surface stability of the rnplasma polymer, and that the material therefore is a very good storage medium. In addition we rninvestigated the glass transition temperature of polystyrene at timescales of 10 µs and found it to be rnapprox. 220 °C. The increase of this characteristic temperature of the polymer results from the short time rnat which the polymer was probed and reflects the well-known time-temperature superposition principle. rnHeatable probes were also used for the characterization of silverazide filled nanocapsules. The use of rnheatable probes allowed determining the decomposition temperature of the capsules from few rnnanograms of material. The measured decomposition temperatures ranged from 180 °C to 225 °C, in rnaccordance with literature values. The investigation of small amounts of sample was necessary due to the rnlimited availability of the material. Furthermore, investigating larger amounts of the capsules using rnconventional thermal gravimetric analysis could lead to contamination or even damage of the instrument. rnBesides the analysis of material parameters I used the heatable probes for the local thermal rndecomposition of pentacene precursor material in order to form nanoscale conductive structures. Here, rnthe thickness of the precursor layer was important for complete thermal decomposition. rnAnother aspect of my work was the investigation of redox active polymers - Poly-10-(4-vinylbenzyl)-10H-rnphenothiazine (PVBPT)- for data storage. Data is stored by changing the local conductivity of the material rnby applying a voltage between tip and surface. The generated structures were stable for more than 16 h. It rnwas shown that the presence of water is essential for succesfull patterning.