4 resultados para Photosynthetic electron rate

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis reports on the synthesis and characterisation of trans-(M)AB2C meso-substituted porphyrin amino acid esters (PAr) (M = 2H or Zn) with tunable electron donating and electron withdrawing Ar substituents at B positions (Ar = 4-C6H4OnBu, 4-C6H4OMe, 2,4,6-C6H2Me3, 4-C6H4Me, C6H5, 4-C6H4F, 4-C6H4CF3, C6F5). These porphyrins were used as key building blocks for photosynthetic LHC (LHC = light-harvesting antenna complex) and RC (RC = reaction center) model compounds.rnBased on free-base or zinc(II) porphyrin amino acid esters and porphyrin acids several amide linked free-base bis(porphyrins) PAr1-PAr2 (Ar1 = 2,4,6-C6H2Me3, C6F5 and Ar2 = 2,4,6-C6H2Me3, 4-C6H4F, 4-C6H4CF3, C6F5), mono metallated bis(porphyrin) PAr1-(Zn)PAr2 (Ar1 = 2,4,6-C6H2Me3 and Ar2 =4-C6H4F) and its doubly zincated complexes (Zn)PAr1-(Zn)PAr2 were prepared. In the fluorescence spectra of free-base bis(porphyrins) the porphyrin with the strongest electron donating power of Ar substituents at B positions is the light emitting unity. The emission of mono metallated bis(porphyrin) occurs only from the free-base porphyrin building block. This phenomenon is caused by an efficient energy transfer likely via the Dexter through-bond mechanism.rnLinking of anthraquinone (Q) as electron acceptor (A) to the N-terminus of porphyrin amino acid esters ((M)PAr) and aminoferrocene (Fc) as electron donor (D) to the C-terminus of the porphyrin resulting in Q-(M)PAr-Fc triads (M = 2H or Zn, Ar = 4-C6H4OnBu, 4-C6H4OMe, 2,4,6-C6H2Me3, 4-C6H4Me, C6H5, 4-C6H4F, 4-C6H4CF3, C6F5) with tunable electron density at the porphyrin chromophore. In these triads initial oxidative PET (Q←(M)PAr) and reductive PET ((M)PAr→Fc) (PET = photoinduced electron transfer) are possible. Both processes leads to an emission quenching of (M)PAr. The efficiency of the PET pathways occurring in the Marcus normal region is controlled by the specific porphyrin electron density.rnAmide-linked conjugates PAr-Fc (Ar = 2,4,6-C6H2Me3, C6F5) and Fmoc-Fc-PAr1 (N-Fmoc-Fc = N-Fmoc protected 1,1’-ferrocene amino acid; Ar1 = C6H5, 4-C6H4F, 4-C6H4CF3, C6F5) as well as hinges PAr2-Fc-PAr1 (Ar1 = C6H5, 4-C6H4F and Ar2 = 2,4,6-C6H2Me3) were studied with respect to the reductive PET. The PET driving force (−GET) in dyads increases with the increasing electron withdrawing character of Ar substituents. Additionally, intramolecular energy transfer between porphyrins PAr1 and PAr2 is feasible in the hinges via the Förster mechanism.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das Protein Cytochrom c Oxidase (CcO) ist ein Enzym der mitochondrialen Atmungskette. Als letzter Komplex (Komplex IV) einer Elektronentransportkette katalysiert sie die Reduktion von molekularem Sauerstoff zu Wasser. Hierbei werden Elektronen von Cytochrom c (Cc) in das Enzym geleitet. Die durch den Redoxprozess freiwerdende freie Enthalpie wird dazu genutzt, einen Protonengradienten über die innere Mitochondrien-Membran aufzubauen. Die zurückwandernden Protonen treiben in der ATP-Synthase die Produktion von Adenosintriphosphat (ATP) an, dem universellen Energieträger in lebenden Organismen. Gegenstand dieser Dissertation sind zeitaufgelöste ATR-FTIR-Messungen des direkten Elektronentransfers in die CcO. Das Protein wird hierzu orientiert auf einer Goldelektrode immobilisiert und in eine künstliche Membran rekonstituiert (Protein-tethered Bilayer Lipid Membrane, ptBLM). Das ptBLM-System wird hinsichtlich einer möglichst hohen Protein-Aktivität optimiert. Elektronen werden durch elektrochemische Anregung von der Elektrode in die CcO injiziert. Die Goldoberfläche wird auf die reflektierende Oberfläche eines Silizium-ATR-Kristalls aufgebracht. Durch die Präparation einer rauen Oberfläche (RMS-Rauigkeit ca. 5 nm) wird eine Verstärkung der IR-Absorption erreicht. Die mit den Ladungstransferprozessen einhergehenden Konformationsänderungen der die Redoxzentren umgebenden Gruppen (CONH-Gerüst und Aminosäure-Seitenketten) können durch Infrarot-Spektroskopie nachgewiesen werden. Phasensensitive Detektion (PSD) wird zur Rauschminderung eingesetzt, um Geschwindigkeitskonstanten für die Redox-Übergänge zu bestimmen. Im Bereich der Amid-I-Bande werden etliche Peaks identifiziert, die sich mit dem Redoxzustand des Proteins ändern. Für das CuA-Zentrum, welches als erstes der vier Redoxzentren der CcO reduziert wird, wird die schnellste Geschwindigkeitskonstante ks=4870/s ermittelt. Für das Häm a3-Zentrum wird eine Geschwindigkeitskonstante von ks=13,8/s ermittelt. Die Ergebnisse sind konsistent zu elektrochemischen und Raman-Spektroskopie-Experimenten, welche ebenfalls in unserer Gruppe durchgeführt wurden. Weitere Themen dieser Dissertation sind der Nachweis der Anwendbarkeit des ptBLM-Systems für andere Membranproteine (Beispiel: bakterielles photosynthetisches Reaktionszentrum) und der Einsatz des ATR-FTIR-Setups für verschiedene künstliche Membransysteme (Aktivitätsnachweis des OR5-Geruchsrezeptors in einer peptidgestützten Membran, Eigenschaften eines Oligoethylenglycol-Spacers).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electromagnetic form factors of the proton are fundamental quantities sensitive to the distribution of charge and magnetization inside the proton. Precise knowledge of the form factors, in particular of the charge and magnetization radii provide strong tests for theory in the non-perturbative regime of QCD. However, the existing data at Q^2 below 1 (GeV/c)^2 are not precise enough for a hard test of theoretical predictions.rnrnFor a more precise determination of the form factors, within this work more than 1400 cross sections of the reaction H(e,e′)p were measured at the Mainz Microtron MAMI using the 3-spectrometer-facility of the A1-collaboration. The data were taken in three periods in the years 2006 and 2007 using beam energies of 180, 315, 450, 585, 720 and 855 MeV. They cover the Q^2 region from 0.004 to 1 (GeV/c)^2 with counting rate uncertainties below 0.2% for most of the data points. The relative luminosity of the measurements was determined using one of the spectrometers as a luminosity monitor. The overlapping acceptances of the measurements maximize the internal redundancy of the data and allow, together with several additions to the standard experimental setup, for tight control of systematic uncertainties.rnTo account for the radiative processes, an event generator was developed and implemented in the simulation package of the analysis software which works without peaking approximation by explicitly calculating the Bethe-Heitler and Born Feynman diagrams for each event.rnTo separate the form factors and to determine the radii, the data were analyzed by fitting a wide selection of form factor models directly to the measured cross sections. These fits also determined the absolute normalization of the different data subsets. The validity of this method was tested with extensive simulations. The results were compared to an extraction via the standard Rosenbluth technique.rnrnThe dip structure in G_E that was seen in the analysis of the previous world data shows up in a modified form. When compared to the standard-dipole form factor as a smooth curve, the extracted G_E exhibits a strong change of the slope around 0.1 (GeV/c)^2, and in the magnetic form factor a dip around 0.2 (GeV/c)^2 is found. This may be taken as indications for a pion cloud. For higher Q^2, the fits yield larger values for G_M than previous measurements, in agreement with form factor ratios from recent precise polarized measurements in the Q2 region up to 0.6 (GeV/c)^2.rnrnThe charge and magnetic rms radii are determined as rn⟨r_e⟩=0.879 ± 0.005(stat.) ± 0.004(syst.) ± 0.002(model) ± 0.004(group) fm,rn⟨r_m⟩=0.777 ± 0.013(stat.) ± 0.009(syst.) ± 0.005(model) ± 0.002(group) fm.rnThis charge radius is significantly larger than theoretical predictions and than the radius of the standard dipole. However, it is in agreement with earlier results measured at the Mainz linear accelerator and with determinations from Hydrogen Lamb shift measurements. The extracted magnetic radius is smaller than previous determinations and than the standard-dipole value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Future experiments in nuclear and particle physics are moving towards the high luminosity regime in order to access rare processes. In this framework, particle detectors require high rate capability together with excellent timing resolution for precise event reconstruction. In order to achieve this, the development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging and expensive. Thus, a current trend in R&D is towards flexible FEE that can be easily adapted to a great variety of detectors, without impairing the required high performance. This thesis reports on a novel FEE for two different detector types: imaging Cherenkov counters and plastic scintillator arrays. The former requires high sensitivity and precision for detection of single photon signals, while the latter is characterized by slower and larger signals typical of scintillation processes. The FEE design was developed using high-bandwidth preamplifiers and fast discriminators which provide Time-over-Threshold (ToT). The use of discriminators allowed for low power consumption, minimal dead-times and self-triggering capabilities, all fundamental aspects for high rate applications. The output signals of the FEE are readout by a high precision TDC system based on FPGA. The performed full characterization of the analogue signals under realistic conditions proved that the ToT information can be used in a novel way for charge measurements or walk corrections, thus improving the obtainable timing resolution. Detailed laboratory investigations proved the feasibility of the ToT method. The full readout chain was investigated in test experiments at the Mainz Microtron: high counting rates per channel of several MHz were achieved, and a timing resolution of better than 100 ps after walk correction based on ToT was obtained. Ongoing applications to fast Time-of-Flight counters and future developments of FEE have been also recently investigated.