7 resultados para Llasere frequency measurements

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10^(−10). Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10^(−9) contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes (6,7)^Li was performed in order to determine the absolute frequency of the 2S → 3S transition. The achieved relative accuracy of 2×10^(−10) is improved by one order of magnitude compared to previous measurements. The results provide an opportunity to determine the nuclear charge radius of the stable and short-lived isotopes in a pure optical way but this requires an improvement of the theoretical calculations by two orders of magnitude. The second experiment presented here was performed at ISOLDE/CERN, where the absolute transition frequencies of the D1 and D2 lines in beryllium ions for the isotopes (7,9,10,11)^Be were measured with an accuracy of about 1 MHz. Therefore, an advanced collinear laser spectroscopy technique involving two counter-propagating frequency-stabilized laser beams with a known absolute frequency was developed. The extracted isotope shifts were combined with recent accurate mass shift calculations and the root-mean square nuclear charge radii of (7,10)^Be and the one-neutron halo nucleus 11^Be were determined. Obtained charge radii are decreasing from 7^Be to 10^Be and increasing again for 11^Be. While the monotone decrease can be explained by a nucleon clustering inside the nucleus, the pronounced increase between 10^Be and 11^Be can be interpreted as a combination of two contributions: the center-of-mass motion of the 10^Be core and a change of intrinsic structure of the core. To disentangle these two contributions, the results from nuclear reaction measurements were used and indicate that the center-of-mass motion is the dominant effect. Additionally, the splitting isotope shift, i.e. the difference in the isotope shifts between the D1 and D2 fine structure transitions, was determined. This shows a good consistency with the theoretical calculations and provides a valuable check of the beryllium experiment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dieser Arbeit wird die bisher präziseste und erste direkte Hochpräzisionsmessung des g-Faktors eines einzelnen Protons präsentiert. Die Messung beruht auf der nicht-destruktiven Bestimmung der Zyklotronfrequenz und der Larmorfrequenz eines in einer Penning-Falle gespeicherten Protons. Zur Bestimmung der Larmorfrequenz wird die Spin-Flip-Wahrscheinlichkeit als Funktion einer externen Spin-Flip-Anregung aufgenommen. Zu diesem Zweck wird der kontinuierliche Stern-Gerlach Effekt verwendet, welcher zu einer Kopplung des Spin-Moments an die axiale Bewegung des Protons führt. Ein Spin-Flip zeigt sich dabei in einem Sprung der axialen Bewegungsfrequenz. Die Schwierigkeit besteht darin, diesen Frequenzsprung auf einem Hintergrund axialer Frequenzfluktuationen zu detektieren. Um diese Herausforderung zu bewältigen, wurden neuartige Methoden und Techniken angewandt. Zum einen wurden supraleitende Nachweise mit höchster Empfindlichkeit entwickelt, welche schnelle und damit präzise Frequenzmessungen erlauben. Zum anderen wurde eine auf dem statistischen Bayes Theorem basierende Spin-Flip-Analyse-Methode angewandt. Mit diesen Verbesserungen war es möglich, einzelne Spin-Flips eines einzelnen Protons zu beobachten. Dies wiederum ermöglichte die Anwendung der sogenannten Doppelfallen-Methode, und damit die eingangs erwähnte Messung des g-Faktors mit einer Präzision von 4.3 10^-9.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamische Messungen mit Quarzresonatoren Die Resonanzfrequenz von Quarzoszillatoren liegt im MHz-Bereich. Die Resonanzen haben hohe Gueten und sind somit empfindlich auf kleine Aenderungen an der Resonatoroberflaeche. 1. Es wurde ein Aufbau entwickelt, um Reibung bei hohen Oberflaechengeschwindigkeiten zu messen (v = 1 m/s). Bei Annaeherung einer Kugel steigen Resonanzfrequenz sowie -breite des Schwingquarzes an. Für groeßere Normalkraefte entsteht ein elastischer Kontakt, der die Frequenzerhoehung erklaert. Kurz vor Eintreten dieses Kontaktes durchlaeuft die Daempfung ein Maximum, das charakteristisch ist für das Auftreten von Reibung. Bei Erhoehung der Schichtdicke (0,4-2,5 nm) einer Schmiermittelbeschichtung (Perfluoropolyether) verringern sich sowohl die Hoehe als auch die Breite dieses Maximums. Es verschwindet mit vollstaendiger Belegung mit einer Monolage (ca. 2 nm). Dies wird durch einen intermittierenden Kontakt der beiden Oberflaechen erklaert. 2. Die Schwingquarzoberfläche wurde mit Polymerbuersten verschiedener Schichtdicken (12-230 nm) beschichtet. Der Loesungsmittelgehalt in diesen Filmen variiert mit dem Dampfdruck der umgebenden Toluolatmosphaere. Bei Trocknung durchlaufen die Filme einen loesungsmittelinduzierten Glasuebergang. Die Sorptionskurven (Loesungsmittelgehalt gegen Dampfdruck) zeigen eine Knick beim Glasuebergang, ihre Ableitungen dagegen eine Stufe. Fuer duenner werdende Schichten verschiebt sich diese Stufe zu niedrigerem Dampfdruck sowie geringerem Loesungsmittelgehalt. Außerdem wird sie breiter und ihre Hoehe nimmt ab.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Der Einsatz von Penningfallen in der Massenspektrometrie hat zu einem einmaligen Genauigkeitssprung geführt. Dadurch wurden Massenwerte verschiedenster Atome zu wichtigen Eingangsparametern bei immer mehr physikalischen Fragestellungen. Die Massenspektrometrie mit Hilfe von Penningfallen basiert auf der Bestimmung der freien Zyklotronfrequenz eines Ions in einem homogenen Magnetfeld νc=qB/(2πm). Sie wird mit Flugzeitmethode (TOF-ICR) bestimmt, wobei eine relative Massenungenauigkeit δm/m von wenigen 10^-9 bei Nukliden mit Lebensdauern von <500 ms erreicht wird. Dies wurde durch die im Rahmen dieser Arbeit erstmals in der Penningfallen-Massenspektrometrie eingesetzten Ramsey-Methode möglich. Dabei werden zeitlich separierte, oszillierenden Feldern zur resonanten Ionenanregung genutzt, um die Frequenzmessung durch die Flugzeitmethode zu verbessern. Damit wurden am Penningfallenmassenspektrometer ISOLTRAP an ISOLDE/CERN die Massen der Nuklide 26,27Al und 38,39Ca bestimmt. Alle Massen wurden in die „Atomic Mass Evaluation“ eingebettet. Die Massenwerte von 26Al und 38Ca dienten insbesondere zu Tests des Standardmodells. Um mit Massenwerten fundamentale Symmetrien oder die Quantenelektrodynamik (QED) in extremen Feldern zu testen wurde ein neues Penningfallenprojekt (PENTATRAP) für hochpräzise Massenmessungen an hochgeladenen Ionen konzipiert. In dieser Doktorarbeit wurde vornehmlich die Entwicklung der Penningfallen betrieben. Eine Neuerung bei Penningfallenexperimenten ist dabei die permanente Beobachtung des Magnetfeldes B und seiner zeitlichen Fluktuationen durch so genannte „Monitorfallen“.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das Penningfallen-Massenspektrometer SHIPTRAP wurde gebaut um HochprÄazi-rnsionsmassenmessungen an schweren Radionukliden durchzufÄuhren, die in Fusions-rnreaktionen produziert und vom Geschwindigkeitsfilter SHIP vom Primärstrahl sepa-rnriert werden. Es besteht aus einer Gaszelle zur Abbremsung der hochenergetis-rnchen Reaktionsprodukte, einem RFQ-Kühler und Buncher zur Kühlung und Akku-rnmulation der Ionen und einem Doppel-Penningfallen-System um Massenmessungenrndurchzuführen. Die Masse wird durch die Messungen der Zyklotronfrequenz desrnentsprechenden Ions in einem starken homogenen Magnetfeld bestimmt. Diese Fre-rnquenz wird mit der Frequenz eines wohlbekannten Referenzions verglichen. Mitrndieser Methode können relative Fehler in der Größenordnung von 10^-8 erreicht werden. Kürzlich konnten die Massen der Nobeliumisotope 252-254No (Z=102) und desrnLawrenciumisotops 255Lr (Z=103) erstmals erfolgreich gemessen werden. Dies warenrndie ersten direkten Massenmessungen an Transuranen. Die Produktionrate dieserrnAtome lag bei etwa eins pro Sekunde und weniger. Die Ergebnisse der Massenmes-rnsungen an Nobelium bestätigen die früheren Massenwerte, die aus Q_alpha-Messungenrnabgeleitet wurden. Im Fall von 255Lr wurde der Massenexzess, der bis dahin nur ausrnsystematischen Trends abgeschätzt wurde, zum ersten Mal direkt bestimmt. DiesernErgebnisse sind ein erster Schritt für die an SHIPTRAP geplante Erforschung derrnRegion der Transurane. Das Hauptziel ist hierbei die Bestimmung der Endpunkternder alpha-Zerfallsketten, die in superschweren Elementen in der Nähe der vorhergesagtenrnStabilitätsinsel ihren Ursprung nehmen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ozon (O3) ist ein wichtiges Oxidierungs- und Treibhausgas in der Erdatmosphäre. Es hat Einfluss auf das Klima, die Luftqualität sowie auf die menschliche Gesundheit und die Vegetation. Ökosysteme, wie beispielsweise Wälder, sind Senken für troposphärisches Ozon und werden in Zukunft, bedingt durch Stürme, Pflanzenschädlinge und Änderungen in der Landnutzung, heterogener sein. Es ist anzunehmen, dass diese Heterogenitäten die Aufnahme von Treibhausgasen verringern und signifikante Rückkopplungen auf das Klimasystem bewirken werden. Beeinflusst wird der Atmosphären-Biosphären-Austausch von Ozon durch stomatäre Aufnahme, Deposition auf Pflanzenoberflächen und Böden sowie chemische Umwandlungen. Diese Prozesse zu verstehen und den Ozonaustausch für verschiedene Ökosysteme zu quantifizieren sind Voraussetzungen, um von lokalen Messungen auf regionale Ozonflüsse zu schließen.rnFür die Messung von vertikalen turbulenten Ozonflüssen wird die Eddy Kovarianz Methode genutzt. Die Verwendung von Eddy Kovarianz Systemen mit geschlossenem Pfad, basierend auf schnellen Chemilumineszenz-Ozonsensoren, kann zu Fehlern in der Flussmessung führen. Ein direkter Vergleich von nebeneinander angebrachten Ozonsensoren ermöglichte es einen Einblick in die Faktoren zu erhalten, die die Genauigkeit der Messungen beeinflussen. Systematische Unterschiede zwischen einzelnen Sensoren und der Einfluss von unterschiedlichen Längen des Einlassschlauches wurden untersucht, indem Frequenzspektren analysiert und Korrekturfaktoren für die Ozonflüsse bestimmt wurden. Die experimentell bestimmten Korrekturfaktoren zeigten keinen signifikanten Unterschied zu Korrekturfaktoren, die mithilfe von theoretischen Transferfunktionen bestimmt wurden, wodurch die Anwendbarkeit der theoretisch ermittelten Faktoren zur Korrektur von Ozonflüssen bestätigt wurde.rnIm Sommer 2011 wurden im Rahmen des EGER (ExchanGE processes in mountainous Regions) Projektes Messungen durchgeführt, um zu einem besseren Verständnis des Atmosphären-Biosphären Ozonaustauschs in gestörten Ökosystemen beizutragen. Ozonflüsse wurden auf beiden Seiten einer Waldkante gemessen, die einen Fichtenwald und einen Windwurf trennt. Auf der straßenähnlichen Freifläche, die durch den Sturm "Kyrill" (2007) entstand, entwickelte sich eine Sekundärvegetation, die sich in ihrer Phänologie und Blattphysiologie vom ursprünglich vorherrschenden Fichtenwald unterschied. Der mittlere nächtliche Fluss über dem Fichtenwald war -6 bis -7 nmol m2 s-1 und nahm auf -13 nmol m2 s-1 um die Mittagszeit ab. Die Ozonflüsse zeigten eine deutliche Beziehung zur Pflanzenverdunstung und CO2 Aufnahme, was darauf hinwies, dass während des Tages der Großteil des Ozons von den Pflanzenstomata aufgenommen wurde. Die relativ hohe nächtliche Deposition wurde durch nicht-stomatäre Prozesse verursacht. Die Deposition über dem Wald war im gesamten Tagesverlauf in etwa doppelt so hoch wie über der Freifläche. Dieses Verhältnis stimmte mit dem Verhältnis des Pflanzenflächenindex (PAI) überein. Die Störung des Ökosystems verringerte somit die Fähigkeit des Bewuchses, als Senke für troposphärisches Ozon zu fungieren. Der deutliche Unterschied der Ozonflüsse der beiden Bewuchsarten verdeutlichte die Herausforderung bei der Regionalisierung von Ozonflüssen in heterogen bewaldeten Gebieten.rnDie gemessenen Flüsse wurden darüber hinaus mit Simulationen verglichen, die mit dem Chemiemodell MLC-CHEM durchgeführt wurden. Um das Modell bezüglich der Berechnung von Ozonflüssen zu evaluieren, wurden gemessene und modellierte Flüsse von zwei Positionen im EGER-Gebiet verwendet. Obwohl die Größenordnung der Flüsse übereinstimmte, zeigten die Ergebnisse eine signifikante Differenz zwischen gemessenen und modellierten Flüssen. Zudem gab es eine klare Abhängigkeit der Differenz von der relativen Feuchte, mit abnehmender Differenz bei zunehmender Feuchte, was zeigte, dass das Modell vor einer Verwendung für umfangreiche Studien des Ozonflusses weiterer Verbesserungen bedarf.rn