6 resultados para Inorganic drugs (Development)

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Iron deficiency is the most common deficiency disease worldwide with many patients who require intravenous iron. Within the last years new kind of parenteral iron complexes as well as generic preparations entered the market. There is a high demand for methods clarifying benefit to risk profiles of old and new iron complexes. It is also necessary to disclose interchangeability between originator and intended copies to avoid severe anaphylactic and anaphylactoid side reaction and assure equivalence of therapeutic effect.rnrnThe investigations presented in this work include physicochemical characterization of nine different parenteral iron containing non-biological complex drugs. rnWe developed an in-vitro assay, which allows the quantification of labile iron in the different complexes and thus it is a useful tool to estimate the pharmaclogical safety regarding iron related adverse drug events. This assay additionally allowed the estimation of complex stability by evaluation of degradation kinetics at the applied conditions.rnrnAn in-ovo study was performed to additionally compare different complexes in respect to body distribution. This in combination with complex stability information allowed the risk estimation of potential local acute and chronic reactions to iron overload.rnrnInformation obtained by the combination of the methods within this work are helpful to estimate the safety and efficacy profile of different iron containing non-biological complex drugs. rnrnPhysicochemical differences between the complexes were demonstrated in respect to size of the inorganic fraction, size and size distribution of the complete particles, structure of the inorganic iron fraction, morphology of the complexes and charge of the complexes. And furthermore significant differences in the biological behavior of different complexes were demonstrated. rnrnThe combination of complex stability and biodistribution as well as the combination of structure, size and stability represent helpful tools for the physicochemical characterization of iron containing non-biological complex drugs and for the estimation of pharmacological safety. This work thus represents an up to date summary of some relevant methods for the characterization of intravenous iron complex drugs in respect to pharmaceutical quality, pharmacological safety and aspects of efficacy. rnrnProspectively, it is worthwhile that the methods within this work will contribute to the development and/or characterization of iron containing nanoparticular formulations with beneficial efficacy and safety profiles.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die Dissertationsschrift beschäftigt sich mit der Entwicklung und Anwendung einer alternativen Probenzuführungstechnik für flüssige Proben in der Massenspektrometrie. Obwohl bereits einige Anstrengungen zur Verbesserung unternommen wurden, weisen konventionelle pneumatische Zerstäuber- und Sprühkammersysteme, die in der Elementspurenanalytik mittels induktiv gekoppeltem Plasma (ICP) standardmäßig verwendet werden, eine geringe Gesamteffizienz auf. Pneumatisch erzeugtes Aerosol ist durch eine breite Tropfengrößenverteilung gekennzeichnet, was den Einsatz einer Sprühkammer bedingt, um die Aerosolcharakteristik an die Betriebsbedingungen des ICPs anzupassen.. Die Erzeugung von Tropfen mit einer sehr engen Tropfengrößenverteilung oder sogar monodispersen Tropfen könnte die Effizienz des Probeneintrags verbessern. Ein Ziel dieser Arbeit ist daher, Tropfen, die mittels des thermischen Tintenstrahldruckverfahrens erzeugt werden, zum Probeneintrag in der Elementmassenspektrometrie einzusetzen. Das thermische Tintenstrahldruckverfahren konnte in der analytischen Chemie im Bereich der Oberflächenanalytik mittels TXRF oder Laserablation bisher zur gezielten, reproduzierbaren Deposition von Tropfen auf Oberflächen eingesetzt werden. Um eine kontinuierliche Tropfenerzeugung zu ermöglichen, wurde ein elektronischer Mikrokontroller entwickelt, der eine Dosiereinheit unabhängig von der Hard- und Software des Druckers steuern kann. Dabei sind alle zur Tropfenerzeugung relevanten Parameter (Frequenz, Heizpulsenergie) unabhängig voneinander einstellbar. Die Dosiereinheit, der "drop-on-demand" Aerosolgenerator (DOD), wurde auf eine Aerosoltransportkammer montiert, welche die erzeugten Tropfen in die Ionisationsquelle befördert. Im Bereich der anorganischen Spurenanalytik konnten durch die Kombination des DOD mit einem automatischen Probengeber 53 Elemente untersucht und die erzielbare Empfindlichkeiten sowie exemplarisch für 15 Elemente die Nachweisgrenzen und die Untergrundäquivalentkonzentrationen ermittelt werden. Damit die Vorteile komfortabel genutzt werden können, wurde eine Kopplung des DOD-Systems mit der miniaturisierten Fließinjektionsanalyse (FIA) sowie miniaturisierten Trenntechniken wie der µHPLC entwickelt. Die Fließinjektionsmethode wurde mit einem zertifizierten Referenzmaterial validiert, wobei für Vanadium und Cadmium die zertifizierten Werte gut reproduziert werden konnten. Transiente Signale konnten bei der Kopplung des Dosiersystems in Verbindung mit der ICP-MS an eine µHPLC abgebildet werden. Die Modifikation der Dosiereinheit zum Ankoppeln an einen kontinuierlichen Probenfluss bedarf noch einer weiteren Reduzierung des verbleibenden Totvolumens. Dazu ist die Unabhängigkeit von den bisher verwendeten, kommerziell erhältlichen Druckerpatronen anzustreben, indem die Dosiereinheit selbst gefertigt wird. Die Vielseitigkeit des Dosiersystems wurde mit der Kopplung an eine kürzlich neu entwickelte Atmosphärendruck-Ionisationsmethode, die "flowing atmospheric-pressure afterglow" Desorptions/Ionisations Ionenquelle (FAPA), aufgezeigt. Ein direkter Eintrag von flüssigen Proben in diese Quelle war bislang nicht möglich, es konnte lediglich eine Desorption von eingetrockneten Rückständen oder direkt von der Flüssigkeitsoberfläche erfolgen. Die Präzision der Analyse ist dabei durch die variable Probenposition eingeschränkt. Mit dem Einsatz des DOD-Systems können flüssige Proben nun direkt in die FAPA eingetragen, was ebenfalls das Kalibrieren bei quantitativen Analysen organischer Verbindungen ermöglicht. Neben illegalen Drogen und deren Metaboliten konnten auch frei verkäufliche Medikamente und ein Sprengstoffanalogon in entsprechend präpariertem reinem Lösungsmittel nachgewiesen werden. Ebenso gelang dies in Urinproben, die mit Drogen und Drogenmetaboliten versetzt wurden. Dabei ist hervorzuheben, dass keinerlei Probenvorbereitung notwendig war und zur Ermittlung der NWG der einzelnen Spezies keine interne oder isotopenmarkierte Standards verwendet wurden. Dennoch sind die ermittelten NWG deutlich niedriger, als die mit der bisherigen Prozedur zur Analyse flüssiger Proben erreichbaren. Um im Vergleich zu der bisher verwendeten "pin-to-plate" Geometrie der FAPA die Lösungsmittelverdampfung zu beschleunigen, wurde eine alternative Elektrodenanordnung entwickelt, bei der die Probe länger in Kontakt mit der "afterglow"-Zone steht. Diese Glimmentladungsquelle ist ringförmig und erlaubt einen Probeneintrag mittels eines zentralen Gasflusses. Wegen der ringförmigen Entladung wird der Name "halo-FAPA" (h-FAPA) für diese Entladungsgeometrie verwendet. Eine grundlegende physikalische und spektroskopische Charakterisierung zeigte, dass es sich tatsächlich um eine FAPA Desorptions/Ionisationsquelle handelt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fine powders commonly have poor flowability and dispersibility due to interparticle adhesion that leads to formation of agglomerates. Knowing about adhesion in particle collectives is indispensable to gain a deeper fundamental understanding of particle behavior in powders. Especially in pharmaceutical industry a control of adhesion forces in powders is mandatory to improve the performance of inhalation products. Typically the size of inhalable particles is in the range of 1 - 5 µm. In this thesis, a new method was developed to measure adhesion forces of particles as an alternative to the established colloidal probe and centrifuge technique, which are both experimentally demanding, time consuming and of limited practical applicability. The new method is based on detachment of individual particles from a surface due to their inertia. The required acceleration in the order of 500 000 g is provided by a Hopkinson bar shock excitation system and measured via laser vibrometry. Particle detachment events are detected on-line by optical video microscopy. Subsequent automated data evaluation allows obtaining a statistical distribution of particle adhesion forces. To validate the new method, adhesion forces for ensembles of single polystyrene and silica microspheres on a polystyrene coated steel surface were measured under ambient conditions. It was possible to investigate more than 150 individual particles in one experiment and obtain adhesion values of particles in a diameter range of 3 - 13 µm. This enables a statistical evaluation while measuring effort and time are considerably lower compared to the established techniques. Measured adhesion forces of smaller particles agreed well with values from colloidal probe measurements and theoretical predictions. However, for the larger particles a stronger increase of adhesion with diameter was observed. This discrepancy might be induced by surface roughness and heterogeneity that influence small and large particles differently. By measuring adhesion forces of corrugated dextran particles with sizes down to 2 µm it was demonstrated that the Hopkinson bar method can be used to characterize more complex sample systems as well. Thus, the new device will be applicable to study a broad variety of different particle-surface combinations on a routine basis, including strongly cohesive powders like pharmaceutical drugs for inhalation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to multiple immune evasion mechanisms of cancer cells, novel therapy approaches are required to overcome the limitations of existing immunotherapies. Bispecific antibodies are potent anti-cancer drugs, which redirect effector T cells for specific tumor cell lysis, thus enabling the patient’s immune system to fight cancer cells. The antibody format used in this proof of concept study–bispecific ideal monoclonal antibodies termed BiMAB–is a tailor-made recombinant protein, which consists of two fused scFv antibodies recognizing different antigens. Both are arranged in tandem on a single peptide chain and the individual variable binding domains are separated by special non-immunogenic linkers. The format is comprised of a scFv targeting CLDN18.2–a gastric cancer tumor associated antigen (TAA) –while the second specificity binds the CD3 epsilon (CD3ε) subunit of the T cell receptor (TCR) on T cells. For the first time, we compared in our IMAB362-based BiMAB setting, four different anti-CD3-scFvs, respectively derived from the mAbs TR66, CLB-T3, as well as the humanized and the murine variant of UCHT1. In addition, we investigated the impact of an N- versus a C-terminal location of the IMAB362-derived scFv and the anti-CD3-scFvs. Thus, nine CLDN18.2 specific BiMAB proteins were generated, of which all showed a remarkably high cytotoxicity towards CLDN18.2-positive tumor cells. Because of its promising effectiveness, 1BiMAB emerged as the BiMAB prototype. The selectivity of 1BiMAB for its TAA and CD3ε, with affinities in the nanomolar range, has been confirmed by in vitro assays. Its dual binding depends on the design of an N-terminally positioned IMAB362 scFv and the consecutive C-terminally positioned TR66 scFv. 1BiMAB provoked a concentration and target cell dependent T cell activation, proliferation, and upregulation of the cytolytic protein Granzyme B, as well as the consequent elimination of target cells. Our results demonstrate that 1BiMAB is able to activate T cells independent of elements that are usually involved in the T cell recognition program, like antigen presentation, MHC restriction, and co-stimulatory effector molecules. In the first in vivo studies using a subcutaneous xenogeneic tumor mouse model in immune incompetent NSG mice, we could prove a significant therapeutic effect of 1BiMAB with partial or complete tumor elimination. The initial in vitro RIBOMAB experiments correspondingly showed encouraging results. The electroporation of 1BiMAB IVT-RNA into target or effector cells was feasible, while the functionality of translated 1BiMAB was proven by induced T cell activation and target cell lysis. Accordingly, we could show that the in vitro RIBOMAB approach was applicable for all nine BiMABs, which proves the RIBOMAB concept. Thus, the CLDN18.2-BiMAB strategy offers great potential for the treatment of cancer. In the future, administered either as protein or as IVT-RNA, the BiMAB format will contribute towards finding solutions to raise and sustain tumor-specific cellular responses elicited by engaged and activated endogenous T cells. This will potentially enable us to overcome immune evasion mechanisms of tumor cells, consequently supporting current solid gastric cancer therapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In der Form von Nanokapseln (AmB-HST), Nanoemulsion beziehungsweise multilamellaren Vesikeln (MLV) wurden drei Amphotericin-B-Formulierungen für die orale Applikation entwickelt, charakterisiert und verglichen. Die neuartige homogene Nanokapsel-Formulierung des hydrophoben Polyen-Antimykotikums Amphotericin B wurde in Analogie zu einem für Simvastatin und andere Arzneistoffe etablierten Prozess aus der Reinsubstanz, Lezithin und Gelatine mit Hilfe des HST-Verfahrens hergestellt. Photometrische Untersuchungen zeigten, dass das Endprodukt aus Monomeren aufgebaut ist. Mittels Mikroskopie ließen sich die Aggregate vor der Umhüllung mit Lezithin und Gelatine im Ausgangsmaterial als individuelle kugelförmige Arzneistoffpartikel darstellen. Strukturuntersuchungen mit dynamischer licht streuung (DLS) zeigten eine enge Größenverteilung der verkapselten Partikel von ca. 1 µm. Die Struktur der Hülle der HST-Partikel wurde erstmalig mit Neutronenstreuung unter Verwendung der Deuterium-basierten Lösungsmittel kontrastmethode aufgeklärt. Durch die teilweise Kontrastmaskierung des Partikelkerns bei der Neutronenstreuung konnte die Lezithin-Gelatine-Hülle als eine dünne, 5,64 ± 0.18 nm dicke Schicht aufgelöst werden, welche der biologischen Lipidmembran ähnlich, im Vergleich aber geringfügig größer ist. Dieses Resultat eröffnet Wege für die Optimierung der Formulierung von pharmazeutischen Nanopartikeln, z.B. durch Oberflächenmodifizierungen. Weitere Untersuchungen mittels Kleinwinkelneutronenstreuung unter Verwendung der D-Kontrastvariation deuten darauf hin, dass die Komponenten der Nanokapseln nicht den gleichen Masseschwerpunkt haben, sondern asymmetrisch aufgebaut sind und dass die stärker streuenden Domänen weiter außen liegen. Die Partikel sind im Vergleich zu Liposomen dichter. In-Vitro Freisetzungsstudien belegen das Solubilisierungsvermögen des HST-Systems, wonach die Freisetzung des Arzneistoffes aus der Formulierung zu allen gemessenen Zeitpunkten höher als diejenige der Reinsubstanz war. rnDie Nanoemulsion-Formulierung von Amphotericin B wurde mit einem Öl und Tensid system, jedoch mit unterschiedlichen Co-Solvenzien, erfolgreich entwickelt. Gemäß der Bestimmung der Löslichkeit in verschiedenen Hilfsstoffen erwies sich der Arzneistoff Amphotericin B als nicht-lipophil, gleichzeitig aber auch als nicht-hydrophil. Die zur Ermittlung der für die Emulsionsbildung notwendigen Hilfstoffkonzentrationen erstellten ternären Diagramme veranschaulichten, dass hohe Öl- und Tensidgehalte zu keiner Emulsionsbildung führten. Dementsprechend betrug der höchste Ölgehalt 10%. Die Tröpfchengröße wuchs mit zunehmender Tensidkonzentration, wobei die Co-Solventmenge der Propylenglykol-haltigen Nanoemulsion indirekt verringert wurde. Für die Transcutol®P-haltige Nanoemulsion hingegen wurde das Gegenteil beobachtet, nämlich eine Abnahme der Tröpfchengröße bei steigenden Tensidkonzentrationen. Durch den Einschluss des Arzneistoffes wurde nicht die Viskosität der Formulierung, sondern die Tröpfchengröße beeinflusst. Der Wirkstoffeinschluss führte zu höheren Tröpfchengrößen. Mit zunehmender Propylenglykolkonzentration wurde der Wirkstoffgehalt erhöht, mit zunehmender Transcutol®P-Konzentration dagegen vermindert. UV/VIS-spektroskopische Analysen deuten darauf hin, dass in beiden Formulierungen Amphotericin B als Monomer vorliegt. Allerdings erwiesen sich die Formulierungen Caco-2-Zellen und humanen roten Blutkörperchen gegenüber als toxisch. Da die Kontrollproben eine höhere Toxizität als die wirkstoffhaltigen Formulierungen zeigten, ist die Toxizität nicht nur auf Amphotericin, sondern auch auf die Hilfsstoffe zurückzuführen. Die solubilisierte Wirkstoffmenge ist in beiden Formulierungen nicht ausreichend im Hinblick auf die eingesetzte Menge an Hilfsstoff nach WHO-Kriterien. Gemäß diesen Untersuchungen erscheinen die Emulsions-Formulierungen für die orale Gabe nicht geeignet. Dennoch sind Tierstudien notwendig, um den Effekt bei Tieren sowie die systemisch verfügbare Wirkstoffmenge zu ermitteln. Dies wird bestandskräftige Schlussfolgerungen bezüglich der Formulierung und Aussagen über mögliche Perspektiven erlauben. Nichtsdestotrotz sind die Präkonzentrate sehr stabil und können bei Raumtemperatur gelagert werden.rnDie multilamellar-vesikulären Formulierungen von Amphotericin B mit ungesättigten und gesättigten neutralen Phospholipiden und Cholesterin wurden erfolgreich entwickelt und enthielten nicht nur Vesikel, sondern auch zusätzliche Strukturen bei zunehmender Cholesterinkonzentration. Mittels Partikelgrößenanalyse wurden bei den Formulierungen mit gesättigten Lipiden Mikropartikel detektiert, was abhängig von der Alkylkettenlänge war. Mit dem ungesättigten Lipid (DOPC) konnten hingegen Nanopartikel mit hinreichender Verkapselung und Partikelgrößenverteilung gebildet werden. Die Ergebnisse der thermischen und FTIR-spektroskopischen Analyse, welche den Einfluss des Arzneistoffes ausschließen ließen, liefern den Nachweis für die mögliche, bereits in der Literatur beschriebene Einlagerung des Wirkstoffs in lipid- und/oder cholesterinreiche Membranen. Mit Hilfe eines linearen Saccharosedichtegradienten konnte die Formulierung in Vesikel und Wirkstoff-Lipid-Komplexe nach bimodaler Verteilung aufgetrennt werden, wobei der Arzneistoff stärker mit den Komplexen als mit den Vesikeln assoziiert ist. Bei den Kleinwinkelneutronenstreu-Experimenten wurde die Methode der Kontrastvariation mit Erfolg angewendet. Dabei konnte gezeigt werden, dass Cholesterol in situ einen Komplex mit Amphotericin B bildet. Diesen Sachverhalt legt unter anderem die beobachtete Differenz in der äquivalenten Streulängendichte der Wirkstoff-Lipid- und Wirkstoff-Lipid-Cholesterin-haltigen kleinen unilamellaren Vesikeln nahe. Das Vorkommen von Bragg-Peaks im Streuprofil weist auf Domänen hin und systematische Untersuchungen zeigten, dass die Anzahl der Domänen mit steigendem Cholesteringehalt zunimmt, ab einem bestimmten Grenzwert jedoch wieder abnimmt. Die Domänen treten vor allem nahe der Außenfläche der Modellmembran auf und bestätigen, dass der Wirkstoff in den Cholesterinreichen Membranen vertikal eingelagert ist. Die Formulierung war sowohl Caco-2-Zellen als auch humanen roten Blutkörperchen gegenüber nicht toxisch und erwies sich unter Berücksichtigung der Aufnahme in Caco-2-Zellen als vielversprechend für die orale Applikation. Die Formulierung zeigt sich somit aussichtsreich und könnte in Tabletten weiterverarbeitet werden. Ein Filmüberzug würde den Wirkstoff gegen die saure Umgebung im Magen schützen. Für die Bestimmung der systemischen Verfügbarkeit der Formulierung sind Tierstudien notwendig. Die entwickelten multilamellaren Formulierungen einschließlich der Wirkstoff-Cholesterin-Komplexe bieten somit gute Aussichten auf die mögliche medizinische Anwendung. rnrn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biorelevante Medien sind entwickelt worden, um die Bedingungen im Magen-Darm-Trakt vor und nach der Mahlzeit zu imitieren. Mit FaSSIF und FeSSIF wurden Medien eingeführt, die nicht nur die pH- und Puffer-Kapazität des Dünndarms widerspiegeln, sondern auch Lipid und physiologische Tensid-Arten enthalten. Diese Medien (FaSSIF-V2 und FaSSlFmod6.5) wurden für Bioverfügbarkeitstudien in der Medikamentenentwicklung im Laufe der Jahre kontinuierlich weiterentwickelt. Dennoch sind die auf dem Markt verfügbaren Medien immer noch nicht in der Lage, die realen physiologischen Bedingungen zu simulieren. In der jetzigen Zusammensetzung sind nicht alle Kompetenten enthalten, welche natürlicher Weise im Duodenum vorkommen. Darüber hinaus wird nur eine 1:5 Verdünnung von FeSSIF zu FaSSIF angenommen, die individuelle Wasserzufuhr bei Medikamentengabe wird hierdurch jedoch nur eingeschränkt simuliert, obwohl diese von Patient zu Patient schwanken kann. rnZiel dieser Dissertation war die Verbesserung der Vorhersage der Auflösung und Absorption lipophiler Arzneistoffe durch Simulation der Bedingungen im zweiten Teil des Zwölffingerdarms mit neuen biorelevanten Medien, sowie unter Einwirkung zusätzlicher Detergention als Wirkstoffträger. rnUm den Effekt der Verdünnungsrate und Zeit im Dünndarm zu untersuchen, wurde die Entwicklung der Nanopartikel in der Magen-Darm-Flüssigkeit FaSSIFmod6.5 zu verschiedenen Zeitpunkten und Wassergehalten untersucht. Dafür wurden kinetische Studien an verschieden konzentrierten Modellmedien nach Verdünnungssprung untersucht. Das Modell entspricht der Vermischung der Gallenflüssigkeit mit dem Darminhalt bei variablem Volumen. Die Ergebnisse zeigen, dass Art und Größe der Nanopartikel stark von Verdünnung und Einirkungszeit abhängen. rnrnDie menschliche Darmflüssigkeit enthält Cholesterin, welches in allen früheren Modellmedien fehlt. Daher wurden biokompatible und physiologische Modellflüssigkeiten, FaSSIF-C, entwickelt. Der Cholesteringehalt von FaSSIF - 7C entspricht der Gallenflüssigkeit einer gesunden Frau, FaSSIF - 10C der einer gesunden männlichen Person und FaSSIF - 13C der in einigen Krankheitszuständen. Die intestinale Teilchen-Struktur-Untersuchung mit dynamische Lichtstreuung (DLS) und Neutronen-Kleinwinkelstreuung (SANS) ergab, dass die Korngröße von Vesikeln mit zunehmender Cholesterin-Konzentration abnahm. Zu hohe Cholesterin-Konzentration bewirkte zusätzlich sehr große Partikel, welche vermutlich aus Cholesterin-reichen “Disks“ bestehen. Die Löslichkeiten einiger BCS Klasse II Wirkstoffe (Fenofibrat, Griseofulvin, Carbamazepin, Danazol) in diesen neuen Medien zeigten, dass die Löslichkeit in unterschiedlicher Weise mit der Cholesteringehalt zusammen hing und dieser Effekt selektiv für die Droge war. rnDarüber hinaus wurde die Wirkung von einigen Tensiden auf die kolloidale Struktur und Löslichkeit von Fenofibrat in FaSSIFmod6.5 und FaSSIF -7C untersucht. Struktur und Löslichkeit waren Tensid- und Konzentrations-abhängig. Im Falle von FaSSIFmod6.5 zeigten die Ergebnisse eine dreifache Verzweigung der Lösungswege. Im Bereich mittlerer Tensidkonzentration wurde eine Löslichkeitslücke der Droge zwischen der Zerstörung der Galle-Liposomen und der Bildung von Tensid-reichen Mizellen beobachtet. In FaSSIF - 7C, zerstörten Tenside in höherer Konzentration die Liposomenstruktur trotz der allgemeinen Stabilisierung der Membranen durch Cholesterin. rnDie in dieser Arbeit vorgestellten Ergebnisse ergeben, dass die Anwesenheit von Cholesterin als eine fehlende Komponente der menschlichen Darmflüssigkeit in biorelevanten Medien wichtig ist und dazu beitragen kann, das in vivo Verhalten schwerlöslicher Arzneistoffe im Körper besser vorhersagen zu können. Der Verdünnungsgrad hat einen Einfluss auf die Nanopartikel-Struktur und Tenside beeinflussen die Löslichkeit von Medikamenten in biorelevanten Medien: Dieser Effekt ist sowohl von der Konzentration das Tensids abhängig, als auch dessen Typ.rnrn