6 resultados para Increasing failure rate

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Many of developing countries are facing crisis in water management due to increasing of population, water scarcity, water contaminations and effects of world economic crisis. Water distribution systems in developing countries are facing many challenges of efficient repair and rehabilitation since the information of water network is very limited, which makes the rehabilitation assessment plans very difficult. Sufficient information with high technology in developed countries makes the assessment for rehabilitation easy. Developing countries have many difficulties to assess the water network causing system failure, deterioration of mains and bad water quality in the network due to pipe corrosion and deterioration. The limited information brought into focus the urgent need to develop economical assessment for rehabilitation of water distribution systems adapted to water utilities. Gaza Strip is subject to a first case study, suffering from severe shortage in the water supply and environmental problems and contamination of underground water resources. This research focuses on improvement of water supply network to reduce the water losses in water network based on limited database using techniques of ArcGIS and commercial water network software (WaterCAD). A new approach for rehabilitation water pipes has been presented in Gaza city case study. Integrated rehabilitation assessment model has been developed for rehabilitation water pipes including three components; hydraulic assessment model, Physical assessment model and Structural assessment model. WaterCAD model has been developed with integrated in ArcGIS to produce the hydraulic assessment model for water network. The model have been designed based on pipe condition assessment with 100 score points as a maximum points for pipe condition. As results from this model, we can indicate that 40% of water pipeline have score points less than 50 points and about 10% of total pipes length have less than 30 score points. By using this model, the rehabilitation plans for each region in Gaza city can be achieved based on available budget and condition of pipes. The second case study is Kuala Lumpur Case from semi-developed countries, which has been used to develop an approach to improve the water network under crucial conditions using, advanced statistical and GIS techniques. Kuala Lumpur (KL) has water losses about 40% and high failure rate, which make severe problem. This case can represent cases in South Asia countries. Kuala Lumpur faced big challenges to reduce the water losses in water network during last 5 years. One of these challenges is high deterioration of asbestos cement (AC) pipes. They need to replace more than 6500 km of AC pipes, which need a huge budget to be achieved. Asbestos cement is subject to deterioration due to various chemical processes that either leach out the cement material or penetrate the concrete to form products that weaken the cement matrix. This case presents an approach for geo-statistical model for modelling pipe failures in a water distribution network. Database of Syabas Company (Kuala Lumpur water company) has been used in developing the model. The statistical models have been calibrated, verified and used to predict failures for both networks and individual pipes. The mathematical formulation developed for failure frequency in Kuala Lumpur was based on different pipeline characteristics, reflecting several factors such as pipe diameter, length, pressure and failure history. Generalized linear model have been applied to predict pipe failures based on District Meter Zone (DMZ) and individual pipe levels. Based on Kuala Lumpur case study, several outputs and implications have been achieved. Correlations between spatial and temporal intervals of pipe failures also have been done using ArcGIS software. Water Pipe Assessment Model (WPAM) has been developed using the analysis of historical pipe failure in Kuala Lumpur which prioritizing the pipe rehabilitation candidates based on ranking system. Frankfurt Water Network in Germany is the third main case study. This case makes an overview for Survival analysis and neural network methods used in water network. Rehabilitation strategies of water pipes have been developed for Frankfurt water network in cooperation with Mainova (Frankfurt Water Company). This thesis also presents a methodology of technical condition assessment of plastic pipes based on simple analysis. This thesis aims to make contribution to improve the prediction of pipe failures in water networks using Geographic Information System (GIS) and Decision Support System (DSS). The output from the technical condition assessment model can be used to estimate future budget needs for rehabilitation and to define pipes with high priority for replacement based on poor condition. rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this thesis, we investigated the evaporation of sessile microdroplets on different solid substrates. Three major aspects were studied: the influence of surface hydrophilicity and heterogeneity on the evaporation dynamics for an insoluble solid substrate, the influence of external process parameters and intrinsic material properties on microstructuring of soluble polymer substrates and the influence of an increased area to volume ratio in a microfluidic capillary, when evaporation is hindered. In the first part, the evaporation dynamics of pure sessile water drops on smooth self-assembled monolayers (SAMs) of thiols or disulfides on gold on mica was studied. With increasing surface hydrophilicity the drop stayed pinned longer. Thus, the total evaporation time of a given initial drop volume was shorter, since the drop surface, through which the evaporation occurs, stays longer large. Usually, for a single drop the volume decreased linearly with t1.5, t being the evaporation time, for a diffusion-controlled evaporation process. However, when we measured the total evaporation time, ttot, for multiple droplets with different initial volumes, V0, we found a scaling of the form V0 = attotb. The more hydrophilic the substrate was, the more showed the scaling exponent a tendency to an increased value up to 1.6. This can be attributed to an increasing evaporation rate through a thin water layer in the vicinity of the drop. Under the assumption of a constant temperature at the substrate surface a cooling of the droplet and thus a decreased evaporation rate could be excluded as a reason for the different scaling exponent by simulations performed by F. Schönfeld at the IMM, Mainz. In contrast, for a hairy surface, made of dialkyldisulfide SAMs with different chain lengths and a 1:1 mixture of hydrophilic and hydrophobic end groups (hydroxy versus methyl group), the scaling exponent was found to be ~ 1.4. It increased to ~ 1.5 with increasing hydrophilicity. A reason for this observation can only be speculated: in the case of longer hydrophobic alkyl chains the formation of an air layer between substrate and surface might be favorable. Thus, the heat transport to the substrate might be reduced, leading to a stronger cooling and thus decreased evaporation rate. In the second part, the microstructuring of polystyrene surfaces by drops of toluene, a good solvent, was investigated. For this a novel deposition technique was developed, with which the drop can be deposited with a syringe. The polymer substrate is lying on a motorized table, which picks up the pendant drop by an upward motion until a liquid bridge is formed. A consecutive downward motion of the table after a variable delay, i.e. the contact time between drop and polymer, leads to the deposition of the droplet, which can evaporate. The resulting microstructure is investigated in dependence of the processes parameters, i.e. the approach and the retraction speed of the substrate and the delay between them, and in dependence of the intrinsic material properties, i.e. the molar mass and the type of the polymer/solvent system. The principal equivalence with the microstructuring by the ink-jet technique was demonstrated. For a high approach and retraction speed of 9 mm/s and no delay between them, a concave microtopology was observed. In agreement with the literature, this can be explained by a flow of solvent and the dissolved polymer to the rim of the pinned droplet, where polymer is accumulated. This effect is analogue to the well-known formation of ring-like stains after the evaporation of coffee drops (coffee-stain effect). With decreasing retraction speed down to 10 µm/s the resulting surface topology changes from concave to convex. This can be explained with the increasing dissolution of polymer into the solvent drop prior to the evaporation. If the polymer concentration is high enough, gelation occurs instead of a flow to the rim and the shape of the convex droplet is received. With increasing delay time from below 0 ms to 1s the depth of the concave microwells decreases from 4.6 µm to 3.2 µm. However, a convex surface topology could not be obtained, since for longer delay times the polymer sticks to the tip of the syringe. Thus, by changing the delay time a fine-tuning of the concave structure is accomplished, while by changing the retraction speed a principal change of the microtopolgy can be achieved. We attribute this to an additional flow inside the liquid bridge, which enhanced polymer dissolution. Even if the pendant drop is evaporating about 30 µm above the polymer surface without any contact (non-contact mode), concave structures were observed. Rim heights as high as 33 µm could be generated for exposure times of 20 min. The concave structure exclusively lay above the flat polymer surface outside the structure even after drying. This shows that toluene is taken up permanently. The increasing rim height, rh, with increasing exposure time to the solvent vapor obeys a diffusion law of rh = rh0  tn, with n in the range of 0.46 ~ 0.65. This hints at a non-Fickian swelling process. A detailed analysis showed that the rim height of the concave structure is modulated, unlike for the drop deposition. This is due to the local stress relaxation, which was initiated by the increasing toluene concentration in the extruded polymer surface. By altering the intrinsic material parameters i.e. the polymer molar mass and the polymer/solvent combination, several types of microstructures could be formed. With increasing molar mass from 20.9 kDa to 1.44 MDa the resulting microstructure changed from convex, to a structure with a dimple in the center, to concave, to finally an irregular structure. This observation can be explained if one assumes that the microstructuring is dominated by two opposing effects, a decreasing solubility with increasing polymer molar mass, but an increasing surface tension gradient leading to instabilities of Marangoni-type. Thus, a polymer with a low molar mass close or below the entanglement limit is subject to a high dissolution rate, which leads to fast gelation compared to the evaporation rate. This way a coffee-rim like effect is eliminated early and a convex structure results. For high molar masses the low dissolution rate and the low polymer diffusion might lead to increased surface tension gradients and a typical local pile-up of polymer is found. For intermediate polymer masses around 200 kDa, the dissolution and evaporation rate are comparable and the typical concave microtopology is found. This interpretation was supported by a quantitative estimation of the diffusion coefficient and the evaporation rate. For a different polymer/solvent system, polyethylmethacrylate (PEMA)/ethylacetate (EA), exclusively concave structures were found. Following the statements above this can be interpreted with a lower dissolution rate. At low molar masses the concentration of PEMA in EA most likely never reaches the gelation point. Thus, a concave instead of a convex structure occurs. At the end of this section, the optically properties of such microstructures for a potential application as microlenses are studied with laser scanning confocal microscopy. In the third part, the droplet was confined into a glass microcapillary to avoid evaporation. Since here, due to an increased area to volume ratio, the surface properties of the liquid and the solid walls became important, the influence of the surface hydrophilicity of the wall on the interfacial tension between two immiscible liquid slugs was investigated. For this a novel method for measuring the interfacial tension between the two liquids within the capillary was developed. This technique was demonstrated by measuring the interfacial tensions between slugs of pure water and standard solvents. For toluene, n-hexane and chloroform 36.2, 50.9 and 34.2 mN/m were measured at 20°C, which is in a good agreement with data from the literature. For a slug of hexane in contact with a slug of pure water containing ethanol in a concentration range between 0 and 70 (v/v %), a difference of up to 6 mN/m was found, when compared to commercial ring tensiometry. This discrepancy is still under debate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

IceCube, ein Neutrinoteleskop, welches zur Zeit am Südpol aufgebaut und voraussichtlich 2011 fertiggestellt sein wird, kann galaktische Kernkollaps-Supernovae mit hoher Signifikanz und unübertroffener statistischer Genauigkeit der Neutrinolichtkurve detektieren. Derartige Supernovae werden begleitet von einem massiven Ausbruch niederenergetischer Neutrinos aller Flavour. Beim Durchfliegen des Detektormediums Eis entstehen Positronen und Elektronen, welche wiederum lokale Tscherenkowlichtschauer produzieren, die in ihrer Summe das gesamte Eis erleuchten. Ein Nachweis ist somit, trotz der Optimierung IceCubes auf hochenergetische Teilchenspuren, über eine kollektive Rauschratenerhöhung aller optischen Module möglich. Die vorwiegende Reaktion ist der inverse Betazerfall der Antielektronneutrinos, welcher über 90,% des gesamten Signals ausmacht.rnrnDiese Arbeit beschreibt die Implementierung und Funktionsweise der Supernova-Datennahme-Software sowie der Echtzeitanalyse, mit welcher die oben genannte Nachweismethode seit August 2007 realisiert ist. Die Messdaten der ersten zwei Jahre wurden ausgewertet und belegen ein extrem stabiles Verhalten des Detektors insgesamt sowie fast aller Lichtsensoren, die eine gemittelte Ausfallquote von lediglich 0,3,% aufweisen. Eine Simulation der Detektorantwort nach zwei unterschiedlichen Supernova-Modellen ergibt eine Sichtweite IceCubes, die im besten Falle bis zur 51,kpc entfernten Großen Magellanschen Wolke reicht. Leider ist der Detektor nicht in der Lage, die Deleptonisierungsspitze aufzulösen, denn Oszillationen der Neutrinoflavour innerhalb des Sterns modifizieren die Neutrinospektren ungünstig. Jedoch können modellunabhängig anhand des frühesten Signalanstiegs die inverse Massenhierarchie sowie $sin^2 2theta_{13} > 10^{-3}$ etabliert werden, falls die Entfernung zur Supernova $leq$,6,kpc beträgt. Gleiches kann durch Auswertung eines möglichen Einflusses der Erdmaterie auf die Neutrinooszillation mit Hilfe der Messung eines zweiten Neutrinodetektors erreicht werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Im Rahmen der vorliegenden Dissertation wurden 106 Minipins bei 62 Patienten (29 Männer und 33 Frauen)untersucht.rnÜberlebensrate betrug 76,4%. Misserfolge, die zum Verlust der Minipins führten wie Mukositis, Lockerung oder Wurzelperforation, stellten sich in 23,7 % (n=25) der Fälle ein. Dabei gingen beim Auftreten von Mukositis 9 von 14 (8,5 %), bei der Lockerung der Minischrauben 8 von 10 (7,5 %) der Minischrauben verloren. Eine Wurzelperforation trat in einem Fall auf. rnDie einzige lingual im Unterkiefer implantierte Schraube ging verloren. Implantation palatinal im Oberkiefer führte in zwei von vier Fällen zum Verlust. rnDie Sofortbelastung der kieferorthopädischen Kortikalisschrauben erscheint ein praktikables Belastungskonzept zu sein.rnDie Verlustraten bei der vestibulären Implantation betrugen 3,8 % (n=4) für den Oberkiefer und 15,1 % (n=16) für den Unterkiefer.rnBei der Implantation in befestigte bzw. unbefestigte Mukosa betrug die Überlebensrate entsprechend 83,3 % (n=72) und 62,3 % (n=22). rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die Molekularbiologie von Menschen ist ein hochkomplexes und vielfältiges Themengebiet, in dem in vielen Bereichen geforscht wird. Der Fokus liegt hier insbesondere auf den Bereichen der Genomik, Proteomik, Transkriptomik und Metabolomik, und Jahre der Forschung haben große Mengen an wertvollen Daten zusammengetragen. Diese Ansammlung wächst stetig und auch für die Zukunft ist keine Stagnation absehbar. Mittlerweile aber hat diese permanente Informationsflut wertvolles Wissen in unüberschaubaren, digitalen Datenbergen begraben und das Sammeln von forschungsspezifischen und zuverlässigen Informationen zu einer großen Herausforderung werden lassen. Die in dieser Dissertation präsentierte Arbeit hat ein umfassendes Kompendium von humanen Geweben für biomedizinische Analysen generiert. Es trägt den Namen medicalgenomics.org und hat diverse biomedizinische Probleme auf der Suche nach spezifischem Wissen in zahlreichen Datenbanken gelöst. Das Kompendium ist das erste seiner Art und sein gewonnenes Wissen wird Wissenschaftlern helfen, einen besseren systematischen Überblick über spezifische Gene oder funktionaler Profile, mit Sicht auf Regulation sowie pathologische und physiologische Bedingungen, zu bekommen. Darüber hinaus ermöglichen verschiedene Abfragemethoden eine effiziente Analyse von signalgebenden Ereignissen, metabolischen Stoffwechselwegen sowie das Studieren der Gene auf der Expressionsebene. Die gesamte Vielfalt dieser Abfrageoptionen ermöglicht den Wissenschaftlern hoch spezialisierte, genetische Straßenkarten zu erstellen, mit deren Hilfe zukünftige Experimente genauer geplant werden können. Infolgedessen können wertvolle Ressourcen und Zeit eingespart werden, bei steigenden Erfolgsaussichten. Des Weiteren kann das umfassende Wissen des Kompendiums genutzt werden, um biomedizinische Hypothesen zu generieren und zu überprüfen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Zur Verbesserung der Sicherheit und Effektivität der Phenprocoumon-Therapie wurden drei unterschiedliche Untersuchungen durchgeführt.rnZunächst wurde auf Grundlage bekannter Datenbanken und Informationsquellen zu Arznei-mittelinteraktionen (Drugdex, Abda Datenbank, Marcumar® Fachinformation, Coumarin-Interaktionsliste der Federatie van Nederlandse Trombosediensten, Review zu Warfarin-Interaktionen) eine handlungsorientierte Interaktionsdatenbank für Phenprocoumon erstellt. Dazu wurden in einer Übersichtstabelle relevante Informationen zu potentiellen Interaktionen für insgesamt 375 Arzneimittel zusammengestellt. Diese Tabelle wurde durch ein dreiköpfiges Expertenteam begutachtet und die potentiellen Interaktionspartner fünf verschiedenen Schweregraden und Stufen klinischer Relevanz zugeordnet. Für fast 50% der potentiellen Interaktionspartner wurden Handlungen als nicht erforderlich erachtet. Für die restlichen potentiellen Interaktionspartner wurden Handlungen zum klinischen Management der Interaktion in Abhängigkeit vom zeitlichen Zusammenhang mit der Phenprocoumon-Einnahme festgelegt. rnAnschließend wurde in einer Anwendungsbeobachtung der Zusammenhang zwischen der zusätzlichen Einnahme potentiell interagierender Arzneimittel (in der entwickelten Datenbank eingestuft mit dem Schweregrad „hoch“ und „sehr hoch“) und der Häufigkeit von Änderungen der Phenprocoumon-Wochendosis an 116 Patienten untersucht. Das relative Risiko für eine Dosisanpassung war bei Patienten in der Interaktions-Gruppe (n=23) signifikant erhöht (RR=1,9; p<0,001). Als weitere potentielle Einflussfaktoren stellten sich zunehmendes Alter (Alter 80-85 Jahre: RR=2; p<0,05), vielfache Komorbiditäten (4 Komorbiditäten: RR=2,1; p<0,05) und eingeschränkte Nieren- (RR=1,47; p>0,05) und Leberfunktion (RR=1,3; p>0,05) heraus.rnZur Untersuchung der Betreuungsqualität von VKA-Patienten im Thrombosedienst Mainz wurden retrospektiv die Daten von 118 Patienten ausgewertet. Als Qualitätsparameter wurden die prozentuale Häufigkeit von INR-Werten im Zielbereich, die TTR (Time in Therapeutic Range), die Dauer der NMH-Therapie, die Zeit bis zum Erreichen des Zielbereichs und der durchschnittliche Abstand zwischen zwei Kontrollterminen ermittelt. Im Median lag jeder Patient mit 73% der gemessenen INR-Werte und im individuellen Zielbereich. Die TTR betrug im Median 80%. Die Patienten benötigten 7 Tage zum Erreichen des Zielbereiches. Die NMH-Therapie wurde über 8 Tage durchgeführt. Die Patienten kamen im Median alle 11 Tage zu einem Kontrolltermin. Im Benchmark zu international publizierten Qualitätskenn-zahlen zur VKA-Therapie ist die Betreuungsqualität im Thrombosedienst Mainz als sehr gut einzustufen.rn