14 resultados para Grating mirrors

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Efficient coupling of light to quantum emitters, such as atoms, molecules or quantum dots, is one of the great challenges in current research. The interaction can be strongly enhanced by coupling the emitter to the eva-nescent field of subwavelength dielectric waveguides that offer strong lateral confinement of the guided light. In this context subwavelength diameter optical nanofibers as part of a tapered optical fiber (TOF) have proven to be powerful tool which also provide an efficient transfer of the light from the interaction region to an optical bus, that is to say, from the nanofiber to an optical fiber. rnAnother approach towards enhancing light–matter interaction is to employ an optical resonator in which the light is circulating and thus passes the emitters many times. Here, both approaches are combined by experi-mentally realizing a microresonator with an integrated nanofiber waist. This is achieved by building a fiber-integrated Fabry-Pérot type resonator from two fiber Bragg grating mirrors with a stop-band near the cesium D2-line wavelength. The characteristics of this resonator fulfill the requirements of nonlinear optics, optical sensing, and cavity quantum electrodynamics in the strong-coupling regime. Together with its advantageous features, such as a constant high coupling strength over a large volume, tunability, high transmission outside the mirror stop band, and a monolithic design, this resonator is a promising tool for experiments with nanofiber-coupled atomic ensembles in the strong-coupling regime. rnThe resonator's high sensitivity to the optical properties of the nanofiber provides a probe for changes of phys-ical parameters that affect the guided optical mode, e.g., the temperature via the thermo-optic effect of silica. Utilizing this detection scheme, the thermalization dynamics due to far-field heat radiation of a nanofiber is studied over a large temperature range. This investigation provides, for the first time, a measurement of the total radiated power of an object with a diameter smaller than all absorption lengths in the thermal spectrum at the level of a single object of deterministic shape and material. The results show excellent agreement with an ab initio thermodynamic model that considers heat radiation as a volumetric effect and that takes the emitter shape and size relative to the emission wavelength into account. Modeling and investigating the thermalization of microscopic objects with arbitrary shape from first principles is of fundamental interest and has important applications, such as heat management in nano-devices or radiative forcing of aerosols in Earth's climate system. rnUsing a similar method, the effect of the TOF's mechanical modes on the polarization and phase of the fiber-guided light is studied. The measurement results show that in typical TOFs these quantities exhibit high-frequency thermal fluctuations. They originate from high-Q torsional oscillations that couple to the nanofiber-guided light via the strain-optic effect. An ab-initio opto-mechanical model of the TOF is developed that provides an accurate quantitative prediction for the mode spectrum and the mechanically induced polarization and phase fluctuations. These high-frequency fluctuations may limit the ultimate ideality of fiber-coupling into photonic structures. Furthermore, first estimations show that they may currently limit the storage time of nanofiber-based atom traps. The model, on the other hand, provides a method to design TOFs with tailored mechanical properties in order to meet experimental requirements. rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last three decades, sensors based on the phenomenon of surface plasmon resonance have proven particularly suitable for real time thin film characterization, gas detection, biomolecular interaction examination and to supplement electrochemical methods. Systems based on prism coupling have been combined with fluorescence detection under the name of surface plasmon fluorescence spectroscopy to increase sensitivity even further. Alternatively, metal gratings can be employed to match photons for plasmon resonance. The real time monitoring of binding reactions not yet been reported in the combination of fluorescence detection and grating coupling. Grating-based systems promise more competitive products, because of reduced operating costs, and offer benefits for device engineering. This thesis is comprised of a comprehensive study of the suitability of grating coupling for fluorescence based analyte detection. Fundamental properties of grating coupled surface plasmon fluorescence spectroscopy are described, as well as issues related to the commercial realization of the method. Several new experimental techniques are introduced and demonstrated in order to optimize performance in certain areas and improve upon capabilities in respect to prism-based systems. Holographically fabricated gratings are characterized by atomic force microscopy and optical methods, aided by simulations and profile parameters responsible for efficient coupling are analyzed. The directional emission of fluorophores immobilized on a grating surface is studied in detail, including the magnitude and geometry of the fluorescence emission pattern for different grating constants and polarizations. Additionally, the separation between the minimum of the reflected intensity and the maximum fluorescence excitation position is examined. One of the key requirements for the commercial feasibility of grating coupling is the cheap and faithful mass production of disposable samples from a given master grating. The replication of gratings is demonstrated by a simple hot embossing method with good reproducibility to address this matter. The in-situ fluorescence detection of analyte immobilization and affinity measurements using grating coupling are described for the first time. The physical factors related to the sensitivity of the technique are assessed and the lower limit of detection of the technique is determined for an exemplary assay. Particular attention is paid to the contribution of bulk fluorophores to the total signal in terms of magnitude and polarization of incident and emitted light. Emission from the bulk can be a limiting factor for experiments with certain assay formats. For that reason, a novel optical method, based on the modulation of both polarization and intensity of the incident beam, is introduced and demonstrated to be capable of eliminating this contribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental investigations of visible Smith-Purcell-radiation with a micro-focused high relativistic electron beam (E=855 MeV) are presented in the near region, in which the electron beam grazes the surface of the grating. The radiation intensity was measured as a function of the angle of observation and of the distance between electron beam axis and the surface of the grating simultaneously for two different wavelengths (360 nm, 546 nm).In the experiments Smith-Purcell-radiation was identified by the measured angular distribution fulfilling the characteristic coherence condition. By the observed distance dependence of the intensity two components of Smith-Purcell-radiation could be separated: one component with the theoretical predicted interaction length hint, which is produced by electrons passing over the surface of the grating, and an additional component in the near region leading to a strong enhancement of the intensity, which is produced by electrons hitting the surface. To describe the intensity of the observed additional radiation component a simple model for optical grating transition radiation, caused by the electrons passing through the grating structure, is presented. Taking into account the simple scalar model, the results of a Monte-Carlo calculation show that the additional radiation component could be explained by optical grating transition radiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Geometrie einer Metalloberfläche bestimmt die Wechselwirkung zwischen der Oberflächenplasmonenresonanz und anderen Energieformen wie Photonen, anderen Oberflächenplasmonen und molekularen Anregungen. In dieser Arbeit wird der Einfluss dieser Effekte auf die optischen Eigenschaften von metallischen Reliefgittern untersucht.Aufgrund von Modellrechungen werden auf tiefen Gitterstrukturen Resonanzen erwartet, die sich als selbstgekoppelte Oberflächenplasmonen interpretieren lassen. Diese Resonanzen wurden aufgrund der Symmetrie des elektromagnetischen Feldes klassifiziert. Es wurden tiefe Gitter mit unterschiedlichen Profilformen hergestellt, die die experimentelle Beobachtung von drei gekoppelten Resonanzen erlauben. Variationen in der Tiefe und Asymmetrie der Gitter sowie in der experimentellen Geometrie zeigen die theoretisch vorausgesagten Effekte.Fluoreszenzfarbstoffe können mit elektromagnetischen Oberflächenresonanzen Energie austauschen. Die Lokalisierung des elektrischen Feldes von gekoppelten Resonanzen führt zu einer Ortsabhängigkeit der Kopplung, die bei 'freien' Oberflächenplasmonen nicht beobachtet wird. Ein theoretisches Modell ist in der Lage, die experimentellen Befunde weitgehend zu beschreiben. Die Ortsabhägigkeit der photochemischen Zerstörungsrate erlaubt die Anwendung dieses Effektes zur Messung von Diffusionsphänomenen in dünnen Filmen.Des weiteren wurde die Polarisationsabhängigkeit der Anregung von Oberflächenplasmonen wurde in konischer Reflexionsgeometrie und die Rolle der Oberflächenplasmonen in der thermisch induzierten Lichtemission untersucht. Ferner wurde eine vereinfachte Auswertungsroutine zur Anwendung von Gittern in der Untersuchung von dünnen dielektrischen Filmen entwickelt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSIONS The focus of this work was the investigation ofanomalies in Tg and dynamics at polymer surfaces. Thethermally induced decay of hot-embossed polymer gratings isstudied using laser-diffraction and atomic force microscopy(AFM). Monodisperse PMMA and PS are selected in the Mwranges of 4.2 to 65.0 kg/mol and 3.47 to 65.0 kg/mol,respectively. Two different modes of measurement were used:the one mode uses temperature ramps to obtain an estimate ofthe near-surface glass temperature, Tdec,0; the other modeinvestigates the dynamics at a constant temperature aboveTg. The temperature-ramp experiments reveal Tdec,0 valuesvery close to the Tg,bulk values, as determined bydifferential scanning calorimetry (DSC). The PMMA of65.0 kg/mol shows a decreased value of Tg, while the PS samples of 3.47 and 10.3 kg/mol (Mwgrating constants and AFM did not show achange in the near-surface Tdec,0. Decay experiments were performed at a variety ofconstant temperatures. Master plots are produced by shifting the decay curves, on the logarithmic time scale,with respect to a reference curve at Tref. From thisprocedure shift factors were extracted. An Arrhenius analysis of the shift factors reveals adecreasing non-Arrhenius (fragile) behavior with molecular weight for PMMA. PS is fragile for all Mw asexpected for linear polymers. Non-Arrhenius behavior allowsone to fit the shift factors to the William-Landel-Ferry(WLF) equation. The WLF parameters for the varying molecular weights ofPMMA and PS were extracted and compared to the values frombulk rheology measurements. Assuming cg1=16+/-2 at Tg, assuggested by Angell, the glass temperature was determinedfrom the dynamic decay experiments. Within the experimentalerrors, the values for Tg,surf(c1=16) and T_g,bulk(c1=16)tend to be smaller than Tdec,0 and Tg,bulk fromtemperature-ramp and DSC measurements, but confirm thecourse of the values with increasing Mw. The comparison of the fragilities (temperaturedependence of the polymer properties at Tg) near the surfaceand in the bulk shows a higher fragility for PS near thesurface, a lower one for PMMA with molecular weights of 4.2and 65.0 kg/mol. The different surface behavior of PS istraced back to a lower degree of cooperation and a largerfree volume fraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, thin functional conducting polyaniline (PANI) films, either doped or undoped, patterned or unpatterned, were prepared by different approaches. The properties of the obtained PANI films were investigated in detail by a combination of electrochemistry with several other techniques, such as SPR, QCM, SPFS, diffraction, etc. The sensing applications (especially biosensing applications) of the prepared PANI films were explored. Firstly, the pure PANI films were prepared by the electropolymerisation method and their doping/dedoping properties in acidic conditions were investigated in detail by a combination of electrochemistry with SPR and QCM. Dielectric constants of PANI at different oxidation states were obtained quantitatively. The results obtained here laid a good foundation for the following investigations of PANI films in neutral pH conditions. Next, PANI multilayer films doped by a variety of materials were prepared by the layer-by-layer method in order to explore their biosensing applications, because of the loss of redox activity of pure PANI in neutral pH conditions. The dopants used include not only the traditionally used linear polyelectrolytes, but also, for the first tim, some other novel materials, like modified gold nanoparticles or modified carbon nanotubes. Our results showed that all the used dopants could form stable multilayer films with PANI. All the obtained PANI multilayer films showed good redox activity in a neutral pH environment, which makes them feasible for bioassays. We found that all the prepared PANI multilayer films can electrocatalyze the oxidation of NADH in neutral conditions at a low potential, although their catalytic efficiencies are different. Among them, PANI/carbon nanotube system showed the highest catalytic efficiency toward the oxidation of NADH, which makes it a good candidate as a NADH sensor. Besides, because some of the prepared PANI multilayer systems were end-terminated with –COOH groups (like PANI/Au nanoparticles system), which can be utilized to easily link biomolecules for biosensing applications. Here, we demonstrated, for the first time, to use the prepared PANI multilayer films for the DNA hybridisation detection. The detection event was monitored either by direct electrochemical method, or by enzyme-amplified electrochemical method, or by surface plasmon enhanced fluorescence spectroscopic method. All the methods can effectively differentiate non-complementary DNA from the complementary ones, even at the single-base mismatch level. It should also be noted that, our success in fabricating PANI multilayer films with modified Au nanoparticles or carbon nanotubes also offered another novel method for incorporating such novel materials into (conducting) polymers. Because of the unique electrochemical and optical properties of each component of the obtained PANI multilayer films, they should also find potential applications in many other fields such as microelectronics, or for electrochromic and photovoltaic devices. Finally, patterned PANI films were fabricated by the combination of several patterning techniques, such as the combination of electrocopolymerization with micromolding in capillaries (EP-MIMIC), the combination of microcontact printing with the layer-by-layer technique (µCP-LBL), and the polystyrene (PS) template induced electropolymerisation method. Using the obtained stripe-shaped PANI/PSS film, a redox-switchable polymer grating based on the surface-plasmon-enhanced mode was constructed and its application in the field of biosensing was explored. It was found that the diffraction efficiency (DE) of the grating was very sensitive to the applied potential (i.e. redox state of the film) as well as the pH environment of the dielectric medium. Moreover, the DE could also be effectively tuned by an electrocatalytic event, such as the electrocatalytic oxidation of NADH by the grating film. By using PS colloidal crystal assemblies as templates, well-ordered 3D interconnected macroporous PANI arrays (PANI inverse opals) were fabricated via electropolymerisation method. The quality of the obtained inverse opals was much higher than those reported by chemical synthesis method. By electrochemical method, the structures of the prepared inverse opals can be easily controlled. To explore the possible biosensing applications of PANI inverse opals, efforts were also done toward the fabrication of PANI composite inverse opals. By selecting proper dopants, high quality inverse opals of PANI composites were fabricated for the first time. And the obtained opaline films remained redox-active in neutral pH conditions, pointing to their possible applications for electrobioassays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diese Arbeit beschäftigt sich mit Strukturbildung im schlechten Lösungsmittel bei ein- und zweikomponentigen Polymerbürsten, bei denen Polymerketten durch Pfropfung am Substrat verankert sind. Solche Systeme zeigen laterale Strukturbildungen, aus denen sich interessante Anwendungen ergeben. Die Bewegung der Polymere erfolgt durch Monte Carlo-Simulationen im Kontinuum, die auf CBMC-Algorithmen sowie lokalen Monomerverschiebungen basieren. Eine neu entwickelte Variante des CBMC-Algorithmus erlaubt die Bewegung innerer Kettenteile, da der bisherige Algorithmus die Monomere in Nähe des Pfropfmonomers nicht gut relaxiert. Zur Untersuchung des Phasenverhaltens werden mehrere Analysemethoden entwickelt und angepasst: Dazu gehören die Minkowski-Maße zur Strukturuntersuchung binären Bürsten und die Pfropfkorrelationen zur Untersuchung des Einflusses von Pfropfmustern. Bei einkomponentigen Bürsten tritt die Strukturbildung nur beim schwach gepfropften System auf, dichte Pfropfungen führen zu geschlossenen Bürsten ohne laterale Struktur. Für den graduellen Übergang zwischen geschlossener und aufgerissener Bürste wird ein Temperaturbereich bestimmt, in dem der Übergang stattfindet. Der Einfluss des Pfropfmusters (Störung der Ausbildung einer langreichweitigen Ordnung) auf die Bürstenkonfiguration wird mit den Pfropfkorrelationen ausgewertet. Bei unregelmäßiger Pfropfung sind die gebildeten Strukturen größer als bei regelmäßiger Pfropfung und auch stabiler gegen höhere Temperaturen. Bei binären Systemen bilden sich Strukturen auch bei dichter Pfropfung aus. Zu den Parametern Temperatur, Pfropfdichte und Pfropfmuster kommt die Zusammensetzung der beiden Komponenten hinzu. So sind weitere Strukturen möglich, bei gleicher Häufigkeit der beiden Komponenten bilden sich streifenförmige, lamellare Muster, bei ungleicher Häufigkeit formt die Minoritätskomponente Cluster, die in der Majoritätskomponente eingebettet sind. Selbst bei gleichmäßig gepfropften Systemen bildet sich keine langreichweitige Ordnung aus. Auch bei binären Bürsten hat das Pfropfmuster großen Einfluss auf die Strukturbildung. Unregelmäßige Pfropfmuster führen schon bei höheren Temperaturen zur Trennung der Komponenten, die gebildeten Strukturen sind aber ungleichmäßiger und etwas größer als bei gleichmäßig gepfropften Systemen. Im Gegensatz zur self consistent field-Theorie berücksichtigen die Simulationen Fluktuationen in der Pfropfung und zeigen daher bessere Übereinstimmungen mit dem Experiment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physicochemical experimental techniques combined with the specificity of a biological recognition system have resulted in a variety of new analytical devices known as biosensors. Biosensors are under intensive development worldwide because they have many potential applications, e.g. in the fields of clinical diagnostics, food analysis, and environmental monitoring. Much effort is spent on the development of highly sensitive sensor platforms to study interactions on the molecular scale. In the first part, this thesis focuses on exploiting the biosensing application of nanoporous gold (NPG) membranes. NPG with randomly distributed nanopores (pore sizes less than 50 nm) will be discussed here. The NPG membrane shows unique plasmonic features, i.e. it supports both propagating and localized surface plasmon resonance modes (p SPR and l-SPR, respectively), both offering sensitive probing of the local refractive index variation on/in NPG. Surface refractive index sensors have an inherent advantage over fluorescence optical biosensors that require a chromophoric group or other luminescence label to transduce the binding event. In the second part, gold/silica composite inverse opals with macroporous structures were investigated with bio- or chemical sensing applications in mind. These samples combined the advantages of a larger available gold surface area with a regular and highly ordered grating structure. The signal of the plasmon was less noisy in these ordered substrate structures compared to the random pore structures of the NPG samples. In the third part of the thesis, surface plasmon resonance (SPR) spectroscopy was applied to probe the protein-protein interaction of the calcium binding protein centrin with the heterotrimeric G-protein transducin on a newly designed sensor platform. SPR spectroscopy was intended to elucidate how the binding of centrin to transducin is regulated towards understanding centrin functions in photoreceptor cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Am Mainzer Mikrotron MAMI wurde ein neuartiges Interferometer entwickelt und getestet, mit dem magneto-optische Effekte an dünnen, freitragenden Folien von 3d-Übergangsmetallen wie Eisen, Kobalt oder Nickel an den L_{2,3}-Absorptionskanten (im Spektralbereich der weichen Röntgenstrahlung) gemessen werden können. Es handelt sich um eine Weiterentwicklung eines an MAMI erprobten Interferometers, das im wesentlichen aus einer kollinearen Anordnung zweier identischer Undulatoren, zwischen die die dünne Probefolie eingebracht wird, und einem Gitterspektrometer besteht. Aus den als Funktion des Abstands der Undulatoren beobachtbaren Intensitätsoszillation lassen sich das Dekrement des Realteils δ und der Absorptionskoeffizient β des komplexen Brechungsindex bestimmen.rnIm Rahmen der vorliegenden Arbeit wurde die Apparatur derart weiterentwickelt, dass auch die magnetisch zirkulare Doppelbrechung Δδ und der magnetisch zirkulare Dichroismus Δβ an den L_{2,3}-Absorptionskanten von Übergangsmetallen gemessen werden können. Der zweite Undulator wurde um die Elektronenstrahlachse um den Winkel Ψ = ±107° drehbar gemacht. Damit dient er auch als Analysator der aus der Folie austretenden elliptisch polarisierten weichen Röntgenstrahlung, für die - wie bei der Faraday-Rotation - die Polarisationsebene gedreht ist. Weiterhin kann die Spaltbreite der 10-poligen Hybrid-Undulatoren mit einer Periodenlänge von 12 mm und damit der Undulatorparameter über eine Antriebsmechanik kontinuierlich variiert werden, wodurch eine optimale Anpassung der Amplituden der Undulatorstrahlung aus den beiden Undulatoren möglich wird. Der maximale Undulatorparameter beträgt K = 1.1. Auch das Spektrometer, das auf einem selbstfokussierenden Gitter mit variierter Liniendichte (im Mittel 1400 Linien / mm) basiert, wurde weiterentwickelt. Als Detektor kommt jetzt eine fensterlose CCD mit 1024 x 1024 Pixeln und einer Pixelgröße von 13 μm x 13 μm zum Einsatz, die im Bildmodus betrieben wird, was die gleichzeitige Messung eines Energieintervalls von ca. 50 eV ermöglicht. Die totale Linienbreite wurde bei einer vertikalen Strahlfleckausdehnung von σ_y = 70 μm (rms) am Neon 1s-3p Übergang bei (867.18 ±0.02) eV zu Δħω = (0.218 ±0.002) eV (FWHM) gemessen. Das hohe Auflösungsvermögen von 4000 und die Möglichkeit der Eichung gegen den 1s-3p Übergang von Neon wurden ausgenutzt, um die Energie der Maxima an den Absorptionskanten von Nickel (weiße Linien) neu zu bestimmen. Die Ergebnisse E_{L_2}=(869.65_{-0.16}^{+0.27}) eV und E_{L_3}=(852.37_{-0.11}^{+0.16}) eV stellen eine Verbesserung früherer Messungen dar, die große Streuungen aufwiesen.rnAus systematischen Messungen als Funktion des Abstandes der Undulatoren und des Drehwinkels Ψ wurden die magnetisch zirkulare Doppelbrechung Δδ im Energiebereich 834 eV ≤ ħω ≤ 885 eV an einer freitragenden, bis zur Sättigung magnetisierten Nickelfolie der Dicke von (96.4 ±2.7) nm gemessen. Sowohl das Auflösungsvermögen als auch die Genauigkeit der Messungen für Δδ übersteigen bekannte Literaturangaben signifikant, so dass eine bisher nicht bekannte Feinstruktur gefunden werden konnte. Außerdem wurde der Betrag des magnetisch zirkularen Dichroismus |Δβ| im Bereich des Maximums an der L_3-Absorptionskante mit hoher Genauigkeit gemessen.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Das VHL-Syndrom umfasst Erkrankungen, die mit einem Funktionsverlust von VHL einhergehen. Das Tumorspektrum umfasst retinale und zerebrale Hämangioblastome, Nierenzysten und klarzellige Nierenkarzinome, Zysten und Tumore des Pankreas, Phäochromocytome, Adenome der Hoden und Tumore des Mittelohrs. Obwohl aufgrund klinischer Studien bekannt ist, welche VHL-Mutation mit welchen Neoplasien assoziiert werden können, konnte bisher kein VHL-Mausmodell das Krankheitsbild des VHL-Syndroms widerspiegeln. Daher ist vermutlich eine zusätzliche Fehlregulation weiterer Gene nötig ist, um die Tumorgenese in den verschiedenen Geweben zu induzieren. In mehreren klarzelligen Nierenkarzinomen konnte bereits eine PTEN-Defizienz nachgewiesen werden, der Verlust von PTEN wird außerdem auch mit der Tumorgenese von Phäochromocytomen assoziiert. Möglicherweise wirken VHL und PTEN also in der Tumorsuppression in der Niere und der Nebenniere zusammen.rnIm Rahmen dieser Arbeit konnte erstmals eine VHL-vermittelte Stabilisierung der PTEN-Konzentration sowohl in embryonalen als auch in Tumor-Zellen der Niere nachgewiesen werden. Die Analyse des Regulationsmechanismus ergab erstens eine Hypoxie-abhängige Abnahme der Transkription von PTEN. Des Weiteren konnte eine VHL-vermittelte Ubiquitinylierung von NEDD4-1, welches als E3-Ligase von PTEN dessen Degradation und Kerntransport reguliert, ermittelt werden. rnIn Nierenkarzinom-Zellen wurde weiterhin eine VHL- bzw. PTEN-Restitution induziert, um die Auswirkungen der beiden Tumorsuppressoren auf das Zellverhalten in vitro und in vivo zu untersuchen. Sowohl VHL als auch PTEN hatten dieselben Effekte lediglich in unterschiedlicher Intensität auf das Verhalten der Zellen. So konnte VHL- und PTEN-abhängig eine Verstärkung der Adhäsion, eine Inhibierung der Migration und eine Verminderung der Überlebens- und Metastasierungsfähigkeit nachgewiesen werden. Des Weiteren wurden Mausmodelle mit einem ubiquitären, heterozygoten Pten-Verlust generiert, die teilweise eine zusätzliche Haploinsuffizienz von Vhl bzw. eine heterozygote VHL Typ II-Mutation (V2B oder V2C) trugen. Sporadisch entwickelten diese Mäuse Vhl-abhängig Lebertumore und Pten-abhängig Lymphome und Ovarialkarzinome. Einige Mäuse mit einer kombinierten Vhl- und Pten-Defizienz bildeten zusätzlich Nierenzysten aus, die teilweise das gesamte Volumen der Niere einnahmen. Besonders häufig entstanden in Pten-haploinsuffizienten Mäusen Phäochromocytome, die durch eine zusätzliche V2B- oder V2C-Mutation in gleichaltrigen Mäusen deutlich weiterentwickelt waren. Demnach induziert erst der gemeinsame Verlust von Vhl und Pten die Bildung von Nierenzysten und Phäochromocytomen, welche dem Krankheitsbild des VHL-Syndroms zugeordnet werden.rnDie Untersuchungen innerhalb dieser Arbeit zeigen erstmalig die Interaktion und Kooperation von VHL und PTEN in der Tumorsuppression. Die Resultate bieten außerdem die Grundlage für weitere Analysen der Auswirkung der VHL-vermittelten PTEN-Stabilisierung und für detailliertere Untersuchungen der durch die kombinierte Vhl- und Pten-Defizienz induzierten Neoplasien der Niere und der Nebennieren-Tumore in in vivo Mausmodellen.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synästhetiker schmecken Berührungen, sehen Farben und Formen, wenn sie Musik hören oder einen Duft riechen. Es wurden auch so außergewöhnliche Formen wie Wochentage-Farben-, Berührung-Geruch- oder Schmerz-Farben-Synästhesien gefunden. Die von Neuro- wissenschaftlern und Philosophen als „Bindung“ genannte Fähigkeit mehrere Reize, die in verschiedenen Hirnarealen verarbeitet werden, miteinander zu koppeln und zu einer einheitlichen Repräsentation bzw. erfahrenen Einheit des Bewusstseins zusammenzufassen, betrifft jeden gesunden Mensch. Synästhetiker sind aber Menschen, deren Gehirne zur „Hyperbindung“ oder zum hyperkohärentem Erleben befähigt sind, da bei ihnen wesentlich mehr solcher Kopplungen entstehen. Das Phänomen der Synästhesie ist schon seit mehreren Jahrhunderten bekannt, aber immer noch ein Rätsel. Bisher glaubten Forscher, solche Phänomene beruhten bloß auf überdurchschnittlich dichten neuronalen Verdrahtungen zwischen sensorischen Hirnregionen. Aus der aktuellen Forschung kann man jedoch schließen, dass die Ursache der Synästhesie nicht allein eine verstärkte Verbindung zwischen zwei Sinneskanälen ist. Laut eigener Studien ist der Sinnesreiz selbst sowie seine fest verdrahteten sensorischen Pfade nicht notwendig für die Auslösung des synästhetischen Erlebens. Eine grundlegende Rolle spielt dabei dessen Bedeutung für einen Synästhetiker. Für die Annahme, dass die Semantik für die synästhetische Wahrnehmung das Entscheidende ist, müssten synästhetische Assoziationen ziemlich flexibel sein. Und genau das wurde herausgefunden, nämlich, dass normalerweise sehr stabile synästhetische Assoziationen unter bestimmten Bedingungen sich auf neue Auslöser übertragen lassen. Weitere Untersuchung betraf die neu entdeckte Schwimmstil-Farbe-Synästhesie, die tritt hervor nicht nur wenn Synästhetiker schwimmen, aber auch wenn sie über das Schwimmen denken. Sogar die Namen dieser charakteristischen Bewegungen können ihre Farbempfindungen auslösen, sobald sie im stimmigen Kontext auftauchen. Wie man von anderen Beispielen in der Hirnforschung weiß, werden häufig benutzte neuronale Pfade im Laufe der Zeit immer stärker ausgebaut. Wenn also ein Synästhetiker auf bestimmte Stimuli häufig stoßt und dabei eine entsprechende Mitempfindung bekommt, kann das mit der Zeit auch seine Hirnanatomie verändern, so dass die angemessenen strukturellen Verknüpfungen entstehen. Die angebotene Erklärung steht also im Einklang mit den bisherigen Ergebnissen. Die vorliegende Dissertation veranschaulicht, wie einheitlich und kohärent Wahrnehmung, Motorik, Emotionen und Denken (sensorische und kognitive Prozesse) im Phänomen der Synästhesie miteinander zusammenhängen. Das synästhetische nicht-konzeptuelle Begleiterlebnis geht mit dem konzeptuellen Inhalt des Auslösers einher. Ähnlich schreiben wir übliche, nicht-synästhetische phänomenale Eigenschaften den bestimmten Begriffen zu. Die Synästhesie bringt solche Verschaltungen einfach auf beeindruckende Weise zum Ausdruck und lässt das mannigfaltige Erleben stärker integrieren.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die vorliegende Arbeit befasste sich mit der kompletten Bandbreite eines chemischen Sensors.rnIn einem ersten Schritt wurde die Desensibilisierung der Quarzmikrowaagen (QCM) gegenüber Störeinflüssen untersucht. Ausgehend von vorangegangenen Arbeiten konnte gezeigt werden, dass eine fluorige Modifikation der QCM-Elektroden die Affinität zu omnipräsenten Substanzen wie Wasser oder Alkanen stark herabsetzt. Neben der Desensibilisierung bewirkt die Schicht darüber hinaus vermutlich eine veränderte Ausrichtung der Affinitätsmaterialien auf der Oberfläche. Dies konnte durch die Anwendung auf einen TATP-Sensorsystem gezeigt werden.rnIm zweiten Teil der Arbeit wurden die vorherrschenden Arten supramolekularer Wechselwirkungen in Wirt-Gast-Systemen anhand gravimetrischer Messungen identifiziert. In Kooperation mit unterschiedlichen Forschergruppen konnte nachgewiesen werden, dass es möglich ist, diese Wechselwirkungen in einem gewissen Rahmen zu beeinflussen und damit die Sensorantworten zu steuern. Effekte wie die Hohlraumzugänglichkeit, die Hohlraumgröße sowie das chemische Milieu im Hohlraum wurden genauer untersucht.rnNeben dem Screening auf neue Affinitätsmaterialien konnten erste Erfolge bei der Übertragung der Erkenntnisse der letzten Jahre auf ein neues Sensorsystem erzielt werden. Zum Einsatz kam hierbei ein optisches Sensor-System basierend auf planaren Bragg-Gittern. Neben der Entwicklung einer geeigneten Messzelle wurde eine Beschichtung der Sensoren mit verschiedenen Cyclodextrin-Derivaten entwickelt.rnIm vierten Teil der Arbeit wurden Studien zur Synthese zweier Tetraphenylenderivate durchgeführt.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn