45 resultados para Electron volt spectrometer

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The beta-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient "a". A first test period (2005/ 2006) showed the “proof-of-principles”. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient "a" (publication: Baessler et al., 2008, Europhys. Journ. A, 38, p.17-26). A second measurement cycle (2007/ 2008) aimed to under-run the relative accuracy of previous experiments (Stratowa et al. (1978), Byrne et al. (2002)) da/a =5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to da/a(syst.)=0.61 %. The statistical accuracy of the analyzed measurements is da/a(stat.)=1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects will be discussed in the last chapter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das Time-of-Flight Aerosol Mass Spectrometer (ToF-AMS) der Firma Aerodyne ist eine Weiterentwicklung des Aerodyne Aerosolmassenspektrometers (Q-AMS). Dieses ist gut charakterisiert und kommt weltweit zum Einsatz. Beide Instrumente nutzen eine aerodynamische Linse, aerodynamische Partikelgrößenbestimmung, thermische Verdampfung und Elektronenstoß-Ionisation. Im Gegensatz zum Q-AMS, wo ein Quadrupolmassenspektrometer zur Analyse der Ionen verwendet wird, kommt beim ToF-AMS ein Flugzeit-Massenspektrometer zum Einsatz. In der vorliegenden Arbeit wird anhand von Laborexperimenten und Feldmesskampagnen gezeigt, dass das ToF-AMS zur quantitativen Messung der chemischen Zusammensetzung von Aerosolpartikeln mit hoher Zeit- und Größenauflösung geeignet ist. Zusätzlich wird ein vollständiges Schema zur ToF-AMS Datenanalyse vorgestellt, dass entwickelt wurde, um quantitative und sinnvolle Ergebnisse aus den aufgenommenen Rohdaten, sowohl von Messkampagnen als auch von Laborexperimenten, zu erhalten. Dieses Schema basiert auf den Charakterisierungsexperimenten, die im Rahmen dieser Arbeit durchgeführt wurden. Es beinhaltet Korrekturen, die angebracht werden müssen, und Kalibrationen, die durchgeführt werden müssen, um zuverlässige Ergebnisse aus den Rohdaten zu extrahieren. Beträchtliche Arbeit wurde außerdem in die Entwicklung eines zuverlässigen und benutzerfreundlichen Datenanalyseprogramms investiert. Dieses Programm kann zur automatischen und systematischen ToF-AMS Datenanalyse und –korrektur genutzt werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electromagnetic form factors of the proton are fundamental quantities sensitive to the distribution of charge and magnetization inside the proton. Precise knowledge of the form factors, in particular of the charge and magnetization radii provide strong tests for theory in the non-perturbative regime of QCD. However, the existing data at Q^2 below 1 (GeV/c)^2 are not precise enough for a hard test of theoretical predictions.rnrnFor a more precise determination of the form factors, within this work more than 1400 cross sections of the reaction H(e,e′)p were measured at the Mainz Microtron MAMI using the 3-spectrometer-facility of the A1-collaboration. The data were taken in three periods in the years 2006 and 2007 using beam energies of 180, 315, 450, 585, 720 and 855 MeV. They cover the Q^2 region from 0.004 to 1 (GeV/c)^2 with counting rate uncertainties below 0.2% for most of the data points. The relative luminosity of the measurements was determined using one of the spectrometers as a luminosity monitor. The overlapping acceptances of the measurements maximize the internal redundancy of the data and allow, together with several additions to the standard experimental setup, for tight control of systematic uncertainties.rnTo account for the radiative processes, an event generator was developed and implemented in the simulation package of the analysis software which works without peaking approximation by explicitly calculating the Bethe-Heitler and Born Feynman diagrams for each event.rnTo separate the form factors and to determine the radii, the data were analyzed by fitting a wide selection of form factor models directly to the measured cross sections. These fits also determined the absolute normalization of the different data subsets. The validity of this method was tested with extensive simulations. The results were compared to an extraction via the standard Rosenbluth technique.rnrnThe dip structure in G_E that was seen in the analysis of the previous world data shows up in a modified form. When compared to the standard-dipole form factor as a smooth curve, the extracted G_E exhibits a strong change of the slope around 0.1 (GeV/c)^2, and in the magnetic form factor a dip around 0.2 (GeV/c)^2 is found. This may be taken as indications for a pion cloud. For higher Q^2, the fits yield larger values for G_M than previous measurements, in agreement with form factor ratios from recent precise polarized measurements in the Q2 region up to 0.6 (GeV/c)^2.rnrnThe charge and magnetic rms radii are determined as rn⟨r_e⟩=0.879 ± 0.005(stat.) ± 0.004(syst.) ± 0.002(model) ± 0.004(group) fm,rn⟨r_m⟩=0.777 ± 0.013(stat.) ± 0.009(syst.) ± 0.005(model) ± 0.002(group) fm.rnThis charge radius is significantly larger than theoretical predictions and than the radius of the standard dipole. However, it is in agreement with earlier results measured at the Mainz linear accelerator and with determinations from Hydrogen Lamb shift measurements. The extracted magnetic radius is smaller than previous determinations and than the standard-dipole value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aSPECT spectrometer has been constructed to measure, with high precision, the integral proton spectrum of the free neutron decay. From this spectrum the neutrino electron angular correlation coefficient a can be inferred. The coefficient a is involved in several Standard Model tests, like the unitarity test of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. aSPECT has been designed to determine the coefficient a with an accuracy better than 3×10−4, that is, one order of magnitude better than the best current accuracy. First measurements with neutron beam with the aSPECT spectrometer were performed in the Forschungsneutronenquelle Heinz Maier-Leibnitz, in Munich. A study of the data taken in this period is presented in this thesis, demonstrating the proof of principle of the spectrometer. However, the observation of situation and time-dependent background instabilities impedes the report of a new value of the coefficient a. A thorough data analysis is carried out to identify sources of these background instabilities in order to improve the aSPECT experiment for future beam times. The investigation indicates that trapped particles are most likely the reason for the background problems. Furthermore, it has been observed that measurements containing less trapped particles provide a-values closer to the currently Particle Data Group value. Based on this findings, different measures are proposed to eliminate potential traps in the spectrometer. Indeed, with the proposed modifications realized for the following beam-times, the observed background instabilities were greatly reduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das aSPECT Spektrometer wurde entworfen, um das Spektrum der Protonen beimrnZerfall freier Neutronen mit hoher Präzision zu messen. Aus diesem Spektrum kann dann der Elektron-Antineutrino Winkelkorrelationskoeffizient "a" mit hoher Genauigkeit bestimmt werden. Das Ziel dieses Experiments ist es, diesen Koeffizienten mit einem absoluten relativen Fehler von weniger als 0.3% zu ermitteln, d.h. deutlich unter dem aktuellen Literaturwert von 5%.rnrnErste Messungen mit dem aSPECT Spektrometer wurden an der Forschungsneutronenquelle Heinz Maier-Leibnitz in München durchgeführt. Jedoch verhinderten zeitabhängige Instabilitäten des Meßhintergrunds eine neue Bestimmung von "a".rnrnDie vorliegende Arbeit basiert hingegen auf den letzten Messungen mit dem aSPECTrnSpektrometer am Institut Laue-Langevin (ILL) in Grenoble, Frankreich. Bei diesen Messungen konnten die Instabilitäten des Meßhintergrunds bereits deutlich reduziert werden. Weiterhin wurden verschiedene Veränderungen vorgenommen, um systematische Fehler zu minimieren und um einen zuverlässigeren Betrieb des Experiments sicherzustellen. Leider konnte aber wegen zu hohen Sättigungseffekten der Empfängerelektronik kein brauchbares Ergebnis gemessen werden. Trotzdem konnten diese und weitere systematische Fehler identifiziert und verringert, bzw. sogar teilweise eliminiert werden, wovon zukünftigernStrahlzeiten an aSPECT profitieren werden.rnrnDer wesentliche Teil der vorliegenden Arbeit befasst sich mit der Analyse und Verbesserung der systematischen Fehler, die durch das elektromagnetische Feld aSPECTs hervorgerufen werden. Hieraus ergaben sich vielerlei Verbesserungen, insbesondere konnten die systematischen Fehler durch das elektrische Feld verringert werden. Die durch das Magnetfeld verursachten Fehler konnten sogar soweit minimiert werden, dass nun eine Verbesserung des aktuellen Literaturwerts von "a" möglich ist. Darüber hinaus wurde in dieser Arbeit ein für den Versuch maßgeschneidertes NMR-Magnetometer entwickelt und soweit verbessert, dass nun Unsicherheiten bei der Charakterisierung des Magnetfeldes soweit reduziert wurden, dass sie für die Bestimmung von "a" mit einer Genauigkeit von mindestens 0.3% vernachlässigbar sind.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology. In this thesis, a measurement of the proton recoil spectrum with the spectrometer aSPECT is described. From this spectrum the antineutrino-electron angular correlation coefficient a can be derived. In our first beam time at the FRM II in Munich, background instabilities prevented us from presenting a new value for a. In the latest beam time at the ILL in Grenoble, the background has been reduced sufficiently. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The aim of the latest beam time was a new value for a with an error well below the present literature value of 4%. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, too high to determine a meaningful result. This thesis focused on the investigation of different systematic effects. With the knowledge of the systematics gained in this thesis, we are able to improve aSPECT to perform a 1% measurement of a in a further beam time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The upgrade of the Mainz Mikrotron (MAMI) electron accelerator facility in 2007 which raised the beam energy up to 1.5,GeV, gives the opportunity to study strangeness production channels through electromagnetic process. The Kaon Spectrometer (KAOS) managed by the A1 Collaboration, enables the efficient detection of the kaons associated with strangeness electroproduction. Used as a single arm spectrometer, it can be combined with the existing high-resolution spectrometers for exclusive measurements in the kinematic domain accessible to them.rnrnFor studying hypernuclear production in the ^A Z(e,e'K^+) _Lambda ^A(Z-1) reaction, the detection of electrons at very forward angles is needed. Therefore, the use of KAOS as a double-arm spectrometer for detection of kaons and the electrons at the same time is mandatory. Thus, the electron arm should be provided with a new detector package, with high counting rate capability and high granularity for a good spatial resolution. To this end, a new state-of-the-art scintillating fiber hodoscope has been developed as an electron detector.rnrnThe hodoscope is made of two planes with a total of 18432 scintillating double-clad fibers of 0.83 mm diameter. Each plane is formed by 72 modules. Each module is formed from a 60deg slanted multi-layer bundle, where 4 fibers of a tilted column are connected to a common read out. The read-out is made with 32 channels of linear array multianode photomultipliers. Signal processing makes use of newly developed double-threshold discriminators. The discriminated signal is sent in parallel to dead-time free time-to-digital modules and to logic modules for triggering purposes.rnrnTwo fiber modules were tested with a carbon beam at GSI, showing a time resolution of 220 ps (FWHM) and a position residual of 270 microm m (FWHM) with a detection efficiency epsilon>99%.rnrnThe characterization of the spectrometer arm has been achieved through simulations calculating the transfer matrix of track parameters from the fiber detector focal plane to the primary vertex. This transfer matrix has been calculated to first order using beam transport optics and has been checked by quasielastic scattering off a carbon target, where the full kinematics is determined by measuring the recoil proton momentum. The reconstruction accuracy for the emission parameters at the quasielastic vertex was found to be on the order of 0.3 % in first test realized.rnrnThe design, construction process, commissioning, testing and characterization of the fiber hodoscope are presented in this work which has been developed at the Institut für Kernphysik of the Johannes Gutenberg - Universität Mainz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Das Detektorsystem des Spektrometers Ader Drei-Spektrometer-Anlage am MainzerElektronenbeschleuniger MAMI wurde im Rahmen dieser Arbeitum ein Fokalebenen-Proton-Polarimeter (FPP) ergänzt.Dazu wurden zwei Horizontale Doppeldriftkammern entworfenund zusammen mit einem Kohlenstoffanalysator hinter derFokalebene des Spektrometers aufgebaut.Zur Berechnung der Spin-Präzession in den inhomogenenMagnetfeldern des Spektrometers wurde das Programm QSPINerstellt und damit eine Spin-Transfer-Matrix (STM) erzeugt,mit der über eine Fitprozedur die Polarisationskomponentender Protonen in der Streuebene an die im FPP gemessenenangepaßt werden können.Mit elastischen Elektron-Proton-Streuexperimenten wurdenfalsche Asymmetrien im FPP untersucht, die berechnete STMbestätigt, die inklusive Proton-Kohlenstoff-Analysierstärkeauf einen größeren Streuwinkelbereich erweitert und dasVerhältnis zwischen dem elektrischen und dem magnetischenSachs-Formfaktor des Protons gemessen.Zur Untersuchung der Coulomb-Quadrupol-Übergangsamplitudebei der Anregung des Nukleons zur Delta(1232)-Resonanzwurden in einem Pion-Elektroproduktions-Experiment am Protonmit dem FPP die Komponenten der Polarisation derRückstoßprotonen in paralleler Kinematik gemessen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hinweise auf die innere Struktur des Nukleons, dessenbeobachtbares Quadrupolmoment verschwindet, lassen sich u.a.durch die Untersuchung des N->Delta(1232)-Übergangsgewinnen. Dieser wird von der magnetischen Dipolanregung M1- einem Spinflip-Übergang - dominiert. In der Reaktion (gamma(lin. pol.) p -> p pi0) gelingt es mittels der Photonasymmetrie Sigma, das Signal der kleinen elektrischen Quadrupolamplitude E2 in einem Interferenztermmit der M1-Amplitude zu verstärken und das VerhältnisREM=E2/M1 des betrachteten Übergangs zu bestimmen. DieE2-Amplitude des N->Delta-Übergangs läßt auf eineDeformation des Nukleons und/oder der Delta-Resonanzschließen. Das zugehörige Experiment wurde am MainzerElektronenbeschleuniger MAMI durchgeführt. Durch kohärenteBremsstrahlung der Elektronen an einem Diamantradiatorstanden im Bereich der Delta(1232)-Resonanz linear polarisierte Photonen zur Verfügung. Insgesamt wurden reellePhotonen im Bereich Egamma=(200-790) MeV von derA2-Photonenmarkierungsanlage (Glasgow--Tagger)energiemarkiert. Mit dem Photonenspektrometer TAPS wurden die pi0-Mesonen über ihre beiden Zerfallsphotonennachgewiesen. Die gewählte Anordnung der 504BaF2-Einzelkristalle um ein Flüssigwasserstofftargeterlaubte den pi0-Nachweis im vollen Polarwinkelbereich. Die Datenbasis zur pi0-Photoproduktion am Proton konntehinsichtlich der Wirkungsquerschnitte und Photonasymmetriendurch Datenpunkte über den gesamten Polarwinkelbereichhinweg nachdrücklich erweitert werden.Eine weiterführende Multipolanalyse der neuen(Proton-pi0)-Daten ermöglichte im Energiebereich derDelta-Resonanz die Bestimmung der s- und p-WellenIsospinamplituden von E0+, M1-, E1+ und M1+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Dreispektrometeranlage der A1-Kollaboration am MainzerElektronenbeschleuniger MAMI wurde im Rahmen dieser Arbeitverwendet, um die Elektrodisintegration des Deuteronsmit Hilfe der Reaktion d(e,e'p)n zu untersuchen. Im ersten Teil der Untersuchungen wurde die longitudinaleund transversale Strukturfunktion aus denWirkungsquerschnitten extrahiert. Die Zentralwerte derkinematischen Parameter waren dabei wie folgt eingestellt:1) Der Impulsübertrag wurde für alle Messungen auf 450 MeV/c festgelegt.2) Das Proton wurde in Richtung des Impulsübertrags nachgewiesen (parallele Kinematik).3) Vier Einstellungen des Energieübertrags, und damit korrespondierend des fehlenden Impulses, wurden gemessen: Energieübertrag / MeV : 128, 226, 289, 360. Fehlender Impuls / (MeV/c): 50, 200, 275, 350.4) Für jede dieser vier Kinematiken wurden mindestens drei verschiedene Einschußenergien bzw. Elektronenstreuwinkel eingestellt, um die Strukturfunktionen mit Hilfe der Rosenbluth-Separation zu bestimmen. Im zweiten Teil der Untersuchungen wurde derWirkungsquerschnitt für hohe fehlende Impulse bestimmt.Dessen Zentralwerte wurden von 30 MeV/c bis 906 MeV/cvariiert, wobei für die hohen fehlenden Impulse das Protonweit außerhalb der Richtung des Impulsübertragesnachzuweisen war. Der Energieübertrag lag dabei zwischen180 MeV und 600 MeV und der Impulsübertrag zwischen608 MeV/c und 698 MeV/c.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An der Drei-Spektrometer-Anlage am Beschleuniger MAMI wurde ein Elektronpolarimeter aufgebaut, das die longitudinale Spinpolarisation für Strahlenergien von 500-880 MeV bestimmt. Messprinzip ist die Møller-Streuung. Weiterhin wird ein Experiment zur Bestimmung der Strahlhelizitäts-Asymmetrie in resonanter Elektroproduktion neutraler Pionen am Proton vorgestellt. Diese Observable bietet Zugang zu nichtresonanten Untergrundamplituden in der Nukleon-Delta-Anregung, die im Hinblick auf die Extraktion der Quadrupolamplituden in diesem Übergang wichtig sind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In dieser Arbeit wurde ein zweidimensionales Kopplungssystem zur Bestimmung von leichtflüchtigen bromierten und iodierten Kohlenwasserstoffen (LHKW) in Wasser- und Luftproben entwickelt. Hierzu wurde ein Gaschromatograph mit einem Elektroneneinfangdetektor (ECD) on-line an ein elementselektives induktiv gekoppeltes Plasma-Massenspektrometer (ICPMS) gekoppelt. Dieses extrem nachweisstarke Analysensystem ermöglicht eine simultane Identifizierung unbekannter und koeluierender Peaks sowie eine vereinfachte Quantifizierung mittels ICPMS. Beim Vergleich des GC-ECD-ICPMS-Kopplungssystem mit den herkömmlichen Detektionsmethoden wie dem Massenspektrometer mit Elektronenstoss-Ionisation und dem Atomemissionsdetektor mit mikrowelleninduziertem Plasma schnitt das neu entwickelte Kopplungssystem ausgezeichnet ab. Für die Isolierung der LHKW aus Meerwasserproben wurde die Purge und Trap Technik verwendet, Luftproben wurden durch Besaugung auf Adsorptionsmaterial angereichert. Im Rahmen des BMBF-Teilprojektes ReHaTrop/AFOHAL wurden im August 2001 und im April/Mai 2002 an der Deutschen Nordseeküste Probenahmen durchgeführt. Die Konzentrationen der Wasserproben lagen im Bereich von 0,1-158 ng L-1, die der Luftproben im Bereich von 0,01-470 pptv. Die Messungen bestätigen die wichtige Rolle von Makroalgen im Zusammenhang mit der Produktion von halogenierten Kohlenwasserstoffen. Die Konzentration der iodierten und bromierten Kohlenwasserstoffe war immer höher in Proben, die direkten Kontakt mit Makroalgen hatten. Inkubationsexperimente zeigen für verschiedene braune und grüne Makroalgen individuelle „Fingerprints“ der biogenen LHKW-Produktion. Bei den Messungen an der Nordseeküste wurden Abhängigkeiten zwischen den LHKW und meteorologischen Parametern gefunden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Drei-Spektrometer-Anlage am Mainzer Institut für Kernphysik wurde um ein zusätzliches Spektrometer ergänzt, welches sich durch seine kurze Baulänge auszeichnet und deshalb Short-Orbit-Spektrometer (SOS) genannt wird. Beim nominellen Abstand des SOS vom Target (66 cm) legen die nachzuweisenden Teilchen zwischen Reaktionsort und Detektor eine mittlere Bahnlänge von 165 cm zurück. Für die schwellennahe Pionproduktion erhöht sich dadurch im Vergleich zu den großen Spektrometern die Überlebenswahrscheinlichkeit geladener Pionen mit Impuls 100 MeV/c von 15% auf 73%. Demzufolge verringert sich der systematische Fehler ("Myon-Kontamination"), etwa bei der geplanten Messung der schwachen Formfaktoren G_A(Q²) und G_P(Q²), signifikant. Den Schwerpunkt der vorliegenden Arbeit bildet die Driftkammer des SOS. Ihre niedrige Massenbelegung (0,03% X_0) zur Reduzierung der Kleinwinkelstreuung ist auf den Nachweis niederenergetischer Pionen hin optimiert. Aufgrund der neuartigen Geometrie des Detektors musste eine eigene Software zur Spurrekonstruktion, Effizienzbestimmung etc. entwickelt werden. Eine komfortable Möglichkeit zur Eichung der Driftweg-Driftzeit-Relation, die durch kubische Splines dargestellt wird, wurde implementiert. Das Auflösungsvermögen des Spurdetektors liegt in der dispersiven Ebene bei 76 µm für die Orts- und 0,23° für die Winkelkoordinate (wahrscheinlichster Fehler) sowie entsprechend in der nicht-dispersiven Ebene bei 110 µm bzw. 0,29°. Zur Rückrechnung der Detektorkoordinaten auf den Reaktionsort wurde die inverse Transfermatrix des Spektrometers bestimmt. Hierzu wurden an Protonen im ¹²C-Kern quasielastisch gestreute Elektronen verwendet, deren Startwinkel durch einen Lochkollimator definiert wurden. Daraus ergeben sich experimentelle Werte für die mittlere Winkelauflösung am Target von sigma_phi = 1,3 mrad bzw. sigma_theta = 10,6 mrad. Da die Impulseichung des SOS nur mittels quasielastischer Streuung (Zweiarmexperiment) durchgeführt werden kann, muss man den Beitrag des Protonarms zur Breite des Piks der fehlenden Masse in einer Monte-Carlo-Simulation abschätzen und herausfalten. Zunächst lässt sich nur abschätzen, dass die Impulsauflösung sicher besser als 1% ist.