19 resultados para Argon ion lasers
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
This doctoral thesis describes the extension of the resonance ionization laser ion source RILIS at CERN/ISOLDE by the addition of an all-solid state tunable titanium:sapphire (Ti:Sa) laser system to complement the well-established system of dye lasers. Synchronous operation of the so called Dual RILIS system of Ti:Sa and dye lasers was investigated and the potential for increased ion beam intensity, reliability, and reduced setup time has been demonstrated. In-source resonance ionization spectroscopy was performed at ISOLDE/CERN and at ISAC/TRIUMF radioactive ion beam facilities to develop an efficient and selective three-colour ionization scheme for the purely radioactive element astatine. A LabVIEW based monitoring, control and measurement system was conceived which enabled, in conjunction with Dual RILIS operation, the spectroscopy of high lying Rydberg states, from which the ionization potential of the astatine atom was determined for the first time experimentally.
Resumo:
Resonante Laserionisations-Massenspektrometrie an Gadolinium zur Isotopenhäufigkeitsanalyse mit geringsten Mengen Die selektive Spuren- und Ultraspurenanalyse des Erdalkalielements Gadolinium eröffnet eine Vielzahl von Anwendungen in der Biomedizin und Kosmochemie. Zum Erreichen der hohen Anforderungen bezüglich Isotopen- und Isobarenselektivität von S>10^7 sowie Gesamteffizienz von e>10^-6 wurde der Einsatz der resonanten Laserionisations-Massenspektrometrie untersucht. Dazu erfolgte die Weiterentwicklung und Anpassung des existierenden Diodenlaser-Quadrupolmassenspektrometersystems. Durch Ionenflugbahn-Simulationsrechnungen wurde für das Quadrupol-Massenspektrometer die erreichbare Nachbarmassenunterdrückung und Transmission in Abhängigkeit von der Auflösung theoretisch vorhergesagt. Die Werte wurden experimentell bestätigt. Aus der beobachteten Peakstruktur erfolgte die Ableitung einer Methode zur Bestimmung der Energieunschärfe des eingesetzten Ionisationsprozesses. Zum Auffinden eines effizienten dreifach resonanten Anregungsschemas wurden die Isotopieverschiebungen und Hyperfeinstrukturen aller stabilen Gadoliniumisotope in zahlreichen Übergängen für die einfach, zweifach und dreifach resonante Ionisation präzise vermessen. Das aufgenommene Spektrum autoionisierender Resonanzen zeigte etwa 150 bislang unbekannter Zustände mit Resonanzüberhöhungen von bis zu fünf Größenordnungen im Ionisationswirkungsquerschnitt. Die entwickelte Methode der Hyperfeinzustandsselektion ermöglichte die Bestimmung der Drehimpulsquantenzahl J der autoionisierenden Resonanzen. Die analytische Charakterisierung der dreistufig resonanten Ionisation von Gadolinium ergab eine Isotopen- und Isobarenselektivität von S(Isotop)>10^12 und S(Isobar)>10^7. Die mit dem Diodenlasersystem erreichte Nachweiseffizienz von e=1-3x10^-6 mit einer untergrundlimitierten Nachweisgrenze von wenigen 10^9 Atomen Gd-158 erlaubte erste Demonstrationsmessungen an medizinischen Gewebeproben.
Resumo:
REX-ISOLDE ist ein Pilotexperiment zur Nachbeschleunigung radioaktiver Ionenstrahlen am on-line Massenseparator ISOLDE am CERN. Ein wichtiges Teilprojekt war die Realisierung der effizienten Umwandlung des kontinuierlichen niederenergetischen Ionenstrahles in kurze Ionenpulse hoher Qualität. Zu diesem Zweck wurde im Rahmen dieser Arbeit REXTRAP, eine gasgefüllte Penningfalle entwickelt, in Betrieb genommen und systematisch untersucht.
Resumo:
Die Resonanzionisations-Massenspektrometrie (RIMS) ist sowohl für spektroskopische Untersuchungen seltener Isotope als auch für den Ultraspurennachweis langlebiger radioaktiver Elemente einsetzbar. Durch die mehrstufige resonante Anregung atomarer Energieniveaus mit anschließender Ionisation mit Laserlicht wird eine sehr hohe Elementselektivität und Ionisationseffizienz erreicht. Der nachfolgende massenselektive Ionennachweis liefert eine gute Isotopenselektivität zusammen mit einer effektiven Untergrundunterdrückung. Ein wichtiger Bestandteil der RIMS-Apparatur ist ein zuverlässig arbeitendes, leistungsstarkes Lasersystem für die Resonanzionisation. Im Rahmen dieser Arbeit wurde ein von einem hochrepetierenden Nd:YAG-Laser gepumptes, aus drei Titan-Saphir-Lasern bestehendes System fertig aufgebaut und in den Routinebetrieb überführt. Die Titan-Saphir-Laser liefern im Durchstimmbereich von 730 - 880 nm eine mittlere Leistung von bis zu 3 W pro Laser bei einer Linienbreite von 2 - 3 GHz. Sie lassen sich computergesteuert in ihren Wellenlängen durchstimmen. Die mittels Resonanzionisation erzeugten Ionen werden dann in einem Flugzeit-Massenspektrometer entsprechend ihrer Masse aufgetrennt und mit einem Kanalplattendetektor nachgewiesen.Als Voraussetzung für die isotopenselektive Ultraspurenanalyse von Plutonium wurden mit diesem Lasersystem die Isotopieverschiebungen eines effizienten, dreistufigen Anregungsschema für Plutonium bestimmt. Die Laserleistungen reichen zur vielfachen Sättigung der ersten beiden Anregungsschritte und zur zweifachen Sättigung des dritten Anregungsschritts aus.Außerdem wurden die Ionisationsenergien von Pu-239 und Pu-244 zur Untersuchung ihrer Isotopenabhängigkeit bestimmt. Die beiden Ionisationsenergien sind im Rahmen der erreichten Genauigkeit bei einem Meßwert von IP239-IP244 = 0,24(82) cm^-1 gleich.Die Nachweiseffizienz der RIMS-Apparatur für Plutonium wurde in Effizienzmessungen zu 10^-5 bestimmt. Durch die gute Untergrundunterdrückung ergab sich daraus eine Nachweisgrenze von 10^6 Atomen bei der Messung eines Plutoniumisotops. Die Bestimmung der Isotopenverhältnisse von Proben mit einer zertifizierten Isotopenzusammensetzung lieferte eine gute Übereinstimmung der Meßwerte mit den angegebenen Zusammensetzungen.Die RIMS-Apparatur wurde zur Bestimmung des Gehalts und der Isotopenzusammensetzung von Plutonium in Meerwasser- und Staubproben eingesetzt.Auf Grund der Isotopenzusammensetzung konnte gezeigt werden, daß das Plutonium bei den meisten Proben aus dem Fallout von oberirdischen Kernwaffentests stammte. Des weiteren wurde Plutonium in Urinproben bestimmt. Die Nachweisgrenzen lagen bei diesen Umweltproben bei 10^6 bis 10^7 Atomen Plutonium und damit um zwei Größenordnungen niedriger als die Nachweisgrenze für Pu-239 bei der alpha-Spektroskopie, der Standardmethode für den Plutoniumnachweis.
Resumo:
Die differentielle Hyperfeinanomalie beschreibt den Isotopieeffekt der magnetischen Hyperfeinwechselwirkung und stellt eine Testmöglichkeit für Kernmodelle dar. Nachdem in einer Reihe von Messungen die A-Faktoren der Hyperfeinwechselwirkung im Grundzustand von zwei stabilen und fünf instabilen Europium-Isotopen bestimmt wurden, sollen nun die Kern-g-Faktoren der gleichen Isotope bestimmt werden.Um die Kern-g-Faktoren zu bestimmen, wurden zunächst die Termschemata des Grundzustandesder stabilen Isotope 151,153Eu+ simuliert. Wegen der hohen Kern- und Hüllenspins I=5/2, J=4 ergeben sich 54 Zeemanzustände und ein komplexes optisches Spektrum.Etwa 10^6 Ionen der beiden stabilen Isotope 151,153Eu+ werden in einer Penningfalle beieinem Magnetfeld von ca. 1.5T gespeichert. Durch Puffergas und Anregung einer Seitenbandfrequenzder Ionenbewegung wird optisches Pumpen in metastabile D-Zustände bei gleichzeitiger Kühlung der Ionenwolke verhindert.Bei Verstimmung eines frequenzverdoppelten Ti:Sa-Lasers wurde die Ionenfluoreszenz aufgenommen. Durch die Simulation der optischen Spektren gelang es, einzelne Übergänge des Isotopes 151Eu+ zu identifizieren. Mit Laser/Mikrowellen-Doppelresonanzmessungen erhält man ein in erster Ordnung dopplerfreies Mikrowellenspektren eines Überganges zwischen zwei Zeemanzuständen im Grundzustand.Durch Messung der Übergangsfrequenzen von insgesamt fünf Delta mI=+1 Übergängen und Bestimmung des Magnetfeldes durch Messung der Zyklotronfrequenz gespeicherter Elektronen konnte der gI-Faktor des Isotopes151Eu zu 151gI = 1.37734(6) bestimmt werden.
Resumo:
In Experimenten an lasergekühlten, in einer linearen Paulfalle gespeicherten $Ca^+$-Ionen wurde dieLebensdauer des metastabilen $3D_{5/2}$-Niveaus durch Beobachtung von Quantensprüngen einzelner Ionen zu 1100(18)msbestimmt. Systematische Fehler durch quenchende Stöße oder Stark-Mischen durch das Speicherfeld liegen unterhalb dererreichten Genauigkeit. Abweichungen von früheren Messungen konnten durch eine vernachlässigte Abhängigkeit derLebensdauer von der Laserleistung des Rückpumplasers erklärt werden. Das Endergebnis zeigt gute Übereinstimmung mitneueren theoretischen Werten. In weiteren Messungen an zehn Ionen wurde in einigen Messreihen eine deutliche Reduktionder Lebensdauer gegenüber einem einzelnen Ion festgestellt. Dabei wurden mehr koinzidente Zerfälle von zwei und dreiIonen beobachtet als für unabhängige Teilchen zu erwarten. In einem Ionenkristall wurde eine räumliche Trennung atomarer Zustände erreicht. Dabei wurde ein Teil der Ionen einesKristalls aus einigen hundert Ionen in den metastabilen Zustand gepumpt, der von den Kühllasern vollständig entkoppeltist. Durch sympathetische Kühlung werden diese Ionen weiterhin gekühlt und der Kristall schmilzt nicht. Durch denLichtdruck, den die Kühllaser ausgeüben, werden die Ionen nach atomaren Zuständen sortiert, weil die lasergekühltenIonen einen Rückstoß erfahren, die übrigen aber nicht. Für zukünftige Experimente wurden Verbesserungen des experimentellen Aufbaus auf den Weg gebracht. So wurden Methodenund Komponenten für eine verbesserte Frequenzstabilisierung der Diodenlaser entwickelt.
Resumo:
Untersuchungen zu ionenchemischen Reaktionen und Mobilitätsmessungen an schweren Elementen in einer Puffergaszelle Die vorgelegte Arbeit beschreibt vorbereitende Untersuchungen zu ionenchemischen Reaktionen und Mobilitätsmessungen schwerer Elemente (Z>100) in einer mit Argon gefüllten Puffergaszelle. Dazu wurden am Element Erbium (Z=68), dem chemischen Homolog von Fermium (Z=100), zunächst in einem Fourier-Transformations-Massenspektrometer (FT/MS) Reaktionen mit Sauerstoff (O2), Methan (CH4) und Butylen (C4H8) untersucht und deren Reaktionskonstanten zu k(Er+O2)=(3,6±0,3)10-10cm3/s, k(Er+C4H8)=(1,3±0,1)10-10cm3/s gemessen. Für die Reaktion Er++CH4 wurde eine Obergrenze der Reaktionskonstante von k(Er+CH4)?,310-15cm3/s bestimmt. Dieselben Reaktionen wurden anschließend in einer mit 60 mbar Argon gefüllten Puffergaszelle am Tandembeschleuniger des Max-Planck-Instituts für Kernphysik in Heidelberg studiert.Das in die Zelle eingeschossene Erbium wurde nach der Thermalisierung in einem zweistufigen Laserprozess resonant ionisiert. Diese Messungen führten zu gleichen Ergebnissen wie die FT/MS-Messungen (k(Er+O2)=3,3±0,4)10-10cm3/s, k(Er+CH4)?210-17cm3/s). Die Reaktion von Erbium mit Butylen wurde ebenfalls beobachtet, eine Reaktionskonstante konnte jedoch nicht bestimmt werden. Die Reaktion von Erbium mit Sauerstoff wurde auch mit den direkt in die Puffergaszelle eingeschossenen Ionen ohne Laserionisation untersucht. Eine reproduzierbare Reaktionskonstante konnte nicht bestimmt werden, mögliche Ursachen werden diskutiert.Aus der Driftzeit der Ionen im Puffergas können Ionenmobilitäten bestimmt werden. Dies erlaubt Rückschlüsse auf die Ionenradien und damit auch auf Bindungslängen in Molekülen. Zwischen Plutonium und Americium wurde bei einer Driftzeit von (1,88±0,01) ms ein Driftzeitunterschied von (0,07±0,02) ms gemessen und daraus eine relative Verringerung des Ionenradius von Americium gegenüber dem von Plutonium um (3,1±1,3)% bestimmt. Relativistische Rechnungen sagen für den atomaren Radius von Americium gegenüber Plutonium eine Kontraktion in gleicher Größenordnung voraus; für Ionenradien existieren zur Zeit noch keine Rechnungen. Aus den gemessenen Driftzeiten des Plutoniums von (1,85±0,01) ms und Plutoniumoxids von (2,38±0,01) ms wurde eine Zunahme des Ionenradius des Plutoniumoxids gegenüber dem Plutonium um (28±2)% bestimmt.Außerdem wurden Reaktionen von Ruthenium (Z=44) und Osmium (Z=76), beides chemische Homologe von Hassium (Z=108), mit Sauerstoff in der FT/MS-Apparatur untersucht, mit dem Ziel widersprüchliche Messungen der Reaktionskonstanten aufzuklären.
Resumo:
Im Rahmen der vorliegenden Arbeit wurde erstmals Laser-Atomspektroskopie an einem Element durchgeführt, für das bisher keine atomaren Niveaus bekannt waren. Die Experimente wurden am Element Fermium mit der Ordnungszahl Z=100 mit der Resonanzionisationsspektroskopie (RIS) in einer Puffergaszelle durchgeführt. Verwendet wurde das Isotop 255Fm mit einer Halbwertszeit von 20.1 h, das im Hochflusskernreaktor des ORNL, Oak Ridge, USA, hergestellt wurde. Die von einem elektrochemischen Filament in das Argon-Puffergas bei einer Temperatur von 960(20)°C abgedampften Fm-Atome wurden mit Lasern in einem Zweistufenprozess resonant ionisiert. Dazu wurde das Licht eines Excimerlaser gepumpten Farbstofflasers für den ersten Anregungsschritt um die Wellenlänge 400 nm durchgestimmt. Ein Teil des Excimer (XeF) Laser Pumplichtes mit den Wellenlänge 351/353 nm wurde für die nicht-resonante Ionisation verwendet. Die Ionen wurden mit Hilfe elektrischer Felder aus der optischen Zelle extrahiert und nach einem Quadrupol Massenfilter mit einem Channeltron-Detektor massenselektiv nachgewiesen. Trotz der geringen Probenmenge von 2.7 x 10^10 eingesetzten Atomen wurden zwei atomare Resonanzen bei Energien von 25099.8(2) cm-1 und 25111.8(2) cm-1 gefunden und das Sättigungsverhalten dieser Linien gemessen. Es wurde ein theoretisches Modell entwickelt, dass sowohl das spektrale Profil der sättigungsverbreiterten Linien als auch die Sättigungskurven beschreibt. Durch Anpassung an die Messdaten konnten die partiellen Übergangsraten in den 3H6 Grundzustand Aki=3.6(7) x 10^6/s und Aki=3.6(6) x 10^6/s bestimmt werden. Der Vergleich der Niveauenergien und Übergangsraten mit Multikonfigurations Dirac-Fock Rechnungen legt die spektroskopische Klassifizierung der beobachteten Niveaus als 5f12 7s7p 5I6 und 5G6 Terme nahe. Weiterhin wurde ein Übergang bei 25740 cm-1 gefunden, der aufgrund der beobachteten Linienbreite von 1000 GHz als Rydbergzustand Zustand mit der Niveauenergie 51480 cm-1 interpretiert wurde und über einen Zweiphotonen Prozess angeregt werden kann. Basierend auf dieser Annahme wurde die Obergrenze für die Ionisationsenergie IP = 52140 cm-1 = 6.5 eV abgeschätzt. In den Messungen wurden Verschiebungen in den Zeitverteilungsspektren zwischen den mono-atomaren Ionen Fm+ und Cf+ und dem Molekül-Ion UO+ festgestellt und auf Driftzeitunterschiede im elektrischen Feld der gasgefüllten optischen Zelle zurückgeführt. Unter einfachen Modellannahmen wurde daraus auf die relativen Unterschiede Delta_r(Fm+,Cf+)/r(Cf+) -0.2 % und Delta_r(UO+,Cf+)/r(Cf+) 20 % in den Ionenradien geschlossen. Über die Bestimmung der Abnahme der Fm-a Aktivität des Filamentes auf der einen Seite und die Messung der Resonanzzählrate auf der anderen Seite, wurde die Nachweiseffizienz der Apparatur zu 4.5(3) x 10^-4 bestimmt. Die Nachweisapparatur wurde mit dem Ziel weiterentwickelt, Laserspektroskopie am Isotop 251Fm durchzuführen, das über die Reaktion 249Cf(a,2n)251Fm direkt in der optischen Zelle erzeugt werden soll. Das Verfahren wurde am chemischen Homolog Erbium getestet. Dabei wurde das Isotop 163Er über die Reaktion 161Dy(a,2n)163Er erzeugt und nach Resonanzionisation nachgewiesen. Die Nachweiseffizienz der Methode wurde zu 1 x 10^-4 bestimmt.
Resumo:
The separator membrane in batteries and fuel cells is of crucial importance for the function of these devices. In lithium ion batteries the separator membrane as well as the polymer matrix of the electrodes consists of polymer electrolytes which are lithium ion conductors. To overcome the disadvantage of currently used polymer electrolytes which are highly swollen with liquids and thus mechanically and electrochemically unstable, the goal of this work is a new generation of solid polymer electrolytes with a rigid backbone and a soft side chain structure. Moreover the novel material should be based on cheap substrates and its synthesis should not be complicated aiming at low overall costs. The new materials are based on hydroxypropylcellulose and oligoethyleneoxide derivatives as starting materials. The grafting of the oligoethyleneoxide side chains onto the cellulose was carried out following two synthetic methods. One is based on a bromide derivative and another based on p-toluolsulfonyl as a leaving group. The side chain reagents were prepared form tri(ethylene glycol) monoethyl ether. In order to improve the mechanical properties the materials were crosslinked. Two different conceptions have been engaged based on either urethane chemistry or photosensitive dimethyl-maleinimide derivatives. PEO - graft - cellulose derivatives with a high degree of substitution between 2,9 and 3,0 were blended with lithium trifluoromethane-sulfonate, lithium bis(trifluorosulfone)imide and lithium tetrafluoroborate. The molar ratios were in the range from 0,02 to 0,2 [Li]/[O]. The products have been characterized with nuclear magnetic resonance (NMR), gel permeation chromatography (GPC) and laserlight scattering (LS) with respect to their degree of substitution and molecular weight. The effect of salt concentration on ionic conductivity, thermal behaviour and morphology has been investiga-ted with impedance spectroscopy, differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). The crosslinking reactions were controlled with dynamic mechanical analysis (DMS). The degree of substitution of our products is varying between 2,8 and 3,0 as determined by NMR. PEO - graft - cellulose derivatives are highly viscous liquids at room temperature with glass transition temperatures around 215 K. The glass transition temperature for the Lithium salt complexes of PEO - graft - cellulose deri-vatives increase with increasing salt content. The maximum conductivity at room temperature is about 10-4 and at 100°C around 10-3 Scm-1. The presence of lithium salt decreases the thermal stability of the complexes in comparison to pure PEO - graft - cellulose derivatives. Complexes heated over 140 – 150°C completely lose their ionic conductivity. The temperature dependence of the conductivity presented as Arrhenius-type plots for all samples is similar in shape and follows a VTF behaviour. This proofs that the ionic transport is closely related to the segmental motions of the polymer chains. Novel cellulose derivatives with grafted oligoethylen-oxide side chains with well-defined chemical structure and high side chain grafting density have been synthesized. Cellulose was chosen as stiff, rod like macromolecule for the backbone while oligoethylen-oxides are chosen as flexible side chains. A maximum grafting density of 3.0 have been obtained. The best conductivity reaches 10-3 Scm-1 at 100°C for a Li-triflate salt complex with a [Li]/[O] ratio of 0.8. The cross-linked complexes containing the lithium salts form elastomeric films with convenient mechanical stability. Our method of cellulose modification is based on relatively cheap and commercially available substrates and as such appears to be a promising alternative for industrial applications.
Resumo:
Im Rahmen dieser Arbeit wurde eine neue Methode für einen empfindlichen und isotopenselektiven Elementnachweis entwickelt. Unter Einsatz von Laserablation geschieht der Probenaufschluß direkt und mit einer Ortsauflösung von unter 30 m. Hierzu wurde ein hochauflösendes MALDI-TOF-Massenspektrometer, welches üblicherweise für biochemische Fragestellungen eingesetzt wird, mit einem spektroskopischen Aufbau zur resonanten Ionisation von Elementgehalten modifiziert. Die Methode ist somit insbesondere für die Untersuchung von Elementspuren in Festkörperproben mit mikroskopischer Struktur konzipiert. Methodische Entwicklungsarbeiten wurden anhand des Elements Gadolinium durchgeführt. Durch die Verwendung gepulster Farbstofflaser stehen ausreichend hohe Laserfelder zur Verfügung, um unabhängig von Hyperfeinstruktur und Isotopieverschiebung Übergänge aller Isotope im Rahmen des Resonanzionisations-Verfahrens zu sättigen. Darauf konnte eine Isotopenverhältnisanalyse mit einer Genauigkeit im Prozentbereich verwirklicht werden. Verschiedene Anregungsleitern wurden untersucht, und mit elementspezifischen Resonanzüberhöhungen bis zu zwei Größenordnungen über dem nicht-resonant gebildeten Untergrund konnte eine Nachweiseffizienz von über 10-4 (entsprechend sub-fg/g-Niveau) erzielt werden. Dazu wurden Simulationsrechnungen zum atomaren Sättigungsverhalten in starken resonanten Laserfeldern durchgeführt. Erste Anwendungen des Laserablationsverfahrens waren Proben kosmologischer Herkunft. Der physikalische Prozeß der Laserablation bei Metallen wurde unter Hochvakuum-Bedingung systematisch in Abhängigkeit der Laserfluenz untersucht. In der ablatierten Plasmaphase erwies sich der Neutralanteil als besonders geeignet für geschwindigkeitsselektive Laserionisations-Messungen. Eine bimodale Struktur wurde beobachtet, bestehend aus einer thermischen und einer schockwellen-induzierten Komponente. Der ionische Anteil der ablatierten Dampfphase konnte über variable elektrische Feldpulse untersucht werden. Laserablation unter Atmosphärenbedingung wurde an einem beschichteten Messingtarget untersucht. Dabei wurde die Entstehung von permanenten Oberflächenstrukturen beobachtet, welche sich durch Nichtgleichgewichts-Prozesse in der Dampfphase erklären lassen.
Resumo:
Die resonante Laserionisation hat sich als ein universales Verfahren für eine Vielzahl von Anwendungen etabliert, die eine selektive Ionisation bei hoher Effizienz erfordern. Hierzu wurden zwei Lasersysteme mit unterschiedlichen Zielsetzungen und Schwerpunkten entwickelt und in dieser Arbeit angewendet. Im ersten Teil der Arbeit wird die Entwicklung der hochauflösenden Resonanzionisations-Massenspektrometrie zum Ultraspurennachweis von 41Ca vorgestellt. Hierzu wurden drei kontinuierliche Diodenlaser mit einem Quadrupolmassenspektrometer kombiniert. Bei einer Nachweiseffizienz von 1 × 10^−5 konnte eine Nachweisgrenze von 2 × 10^-13 41Ca/totCa erreicht werden. Das in den Routinebetrieb überführte Meßverfahren ermöglichte die Teilnahme an einem interdisziplinären Netzwerk zur Osteoporose-Forschung. In Vergleichsmessungen der Resonanzionisations-Massenspektrometrie mit allen derzeit existierenden Meßverfahren zum 41Ca-Ultraspurennachweis konnte eine sehr gute Übereinstimmung erzielt werden. Der zweite Teil der Arbeit beinhaltet die Adaption eines durchstimmbaren, hochrepetierenden Titan:Saphir-Lasersystem für den Einsatz an Laserionenquellen zur selektiven Erzeugung radioaktiver Ionenstrahlen. Das entwickelte Lasersystem ermöglicht eine effiziente, resonante Anregung des Großteils der Elemente im Periodensystem. Hierzu wurde eine kombinierte Frequenzverdopplungs- und Frequenzverdreifachungseinheit zur Erzeugung höherer Harmonischer aufgebaut. Die Anwendbarkeit eines solchen reinen Festkörper-Lasersystems wurde in zahlreichen off-line Testmessungen sowohl in Mainz als auch an den ISOL Einrichtungen am TRIUMF und ORNL gezeigt und führte zum ersten on-line Einsatz am TRIUMF.
Resumo:
Die vorliegende Dissertation beschreibt die Realisation des neuartigen Konzepts der Laserionenquellenfalle für die on-line Produktion exotischer Nuklide und für den Nachweis von Spurenisotopen in Proben mit starken Isobarenkontaminationen. Ziel dieser Entwicklung ist eine wesentliche Steigerung der Isobarenselektivität einer herkömmlichen Laserionenquelle, sowie die Erzeugung zeitlich kontrollierter Ionenpulse mit hervorragender Strahlqualität. Es konnte die prizipielle Funktionsfähigkeit des Systems in Kombination mit einem Titan:Saphir-Lasersystem für die Elemente Gallium, Calcium und Nickel demonstriert und Ionenpulse mit einer minimalen Pulslänge von 1 µs erzeugt werden. Nach ersten Abschätzungen ist die Effizienz des Systems etwa einen Faktor 2500 geringer als die einer herkömmlichen Laserionenquelle. Der zweite Teil der Arbeit beschäftigt sich mit dem spurenanalytischen Nachweis von 99-Tc, mit dem Ziel, das Verhalten von 99-Tc in der Umgebung eines möglichen Endlagers für nukleare Abfälle studieren zu können. Hier wurden erste Studien mit dem kurzlebigen Isomer 99m-Tc zur Wechselwirkung von Tc(VII) mit Huminsäure und Kaolinit durchgeführt. Für den Einsatz der Laserionenquellenfalle in der Ultraspurenanalyse, wurde ein effizientes Anregungsschema für Titan:Saphir-Laser entwickelt und 99-Tc in einer herkömmlichen Ionenquelle nachgewiesen. Der letzte Teil der Arbeit beschreibt Machbarkeitsstudien zum Aufbau einer Laserionenquelle auf Basis eines Titan:Sahphir-Lasersystems, die parallel zu oben genannten Entwicklungen am Oak Ridge National Laboratory durchgeführt wurden. Im Rahmen dieser Messungen wurden Anregungsschemata für die resonante Anregung und Ionisation von Kupfer und Palladium für Titan:Saphir-Laser getestet. Dabei konnte zum ersten Mal frequenzvervierfachtes Laserlicht in einer Laserionenquelle eingesetzt werden. Am ORNL wurden Studien zur Zeitstruktur von Laserionenpulsen, sowie Emittanzmessungen von Laser- und Oberflächenionenstrahlen durchgeführt werden.
Resumo:
Mixed tethered bilayer lipid membranes (tBLMs) are described based on the self-assembly of a monolayer on template stripped gold, of an archea analogue thiolipid, 2,3-di-o-phytanyl-sn-glycerol-1-tetraethylene glycol-D,L--lipoic acid ester lipid (DPTL), and a newly designed dilution molecule, tetraethylene glycol-D,L--lipoic acid ester (TEGL). The usage of spacer and addition of extra dilution molecules between the substrate and the bilayer is that this architecture provides an ionic reservoir underneath the membrane, avoiding direct contact of the embedded membrane proteins with the gold electrodes and increasing the lateral diffusion of the bilayer, thus allowing for the incorporation of complex channels proteins which are failed in non-diluted systems. The tBLM is completed by fusion of liposomes made from a mixture of 1,2-diphythanolyl-sn-glycero-3-phosphocholine (DPhyPC), cholesterol, and 1,2-diphytanoyl-sn-Glycero-3-phosphate (DPhyPG) in a molar ratio of 6:3:1. Varying the mixing ratio, the optimum mixing ratio was obtained at a dilution factor of DPTL and TEGL at 90%:10%. Only under these conditions, the mixed tBLM showed electrical properties, as shown by EIS, which are comparable to a BLM. With higher dilution factors, a defect-free lipid bilayer was not formed. Formation of bilayers have been characterized by different techniques, such as surface plasmon resonance (SPR), electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), and quartz crystal microbalance (QCM). Different proteins such as hemolysin, melittin, gramicidin, M2, Maxi-K, nAChR and bacteriohodopsin are incorporated into these tBLMs as shown by SPR and EIS studies. Ionic conductivity at 0 V vs. Ag|AgCl, 3M KCl were measured by EIS measurements. Our results indicate that these proteins have been successfully incorporated into a very stable tBLM environment in a functionally active form. Therefore, we conclude that the mixed tBLMs have been successfully designed as a general platform for biosensing and screening purposes of membrane proteins.
Abscheidung und Charakterisierung von Plasmapolymerschichten auf Fluorkohlenstoff- und Siloxan-Basis
Resumo:
In dieser Arbeit wurden Fluorkohlenstoff-basierte und siliziumorganische Plasmapolymerfilme hergestellt und hinsichtlich ihrer strukturellen und funktionalen Eigenschaften untersucht. Beide untersuchten Materialsysteme sind in der Beschichtungstechnologie von großem wissenschaftlichen und anwendungstechnischen Interesse. Die Schichtabscheidung erfolgte mittels plasmachemischer Gasphasenabscheidung (PECVD) an Parallelplattenreaktoren. Bei den Untersuchungen zur Fluorkohlenstoff-Plasmapolymerisation stand die Herstellung ultra-dünner, d. h. weniger als 5 nm dicker Schichten im Vordergrund. Dies wurde durch gepulste Plasmaanregung und Verwendung eines Gasgemisches aus Trifluormethan (CHF3) und Argon realisiert. Die Bindungsstruktur der Schichten wurden in Abhängigkeit der eingespeisten Leistung, die den Fragmentationsgrad der Monomere im Plasma bestimmt, analysiert. Hierzu wurden die Röntgen-Photoelektronenspektroskopie (XPS), Rasterkraftmikroskopie (AFM), Flugzeit-Sekundärionenmassenspektrometrie (ToF-SIMS) und Röntgenreflektometrie (XRR) eingesetzt. Es zeigte sich, dass die abgeschiedenen Schichten ein homogenes Wachstumsverhalten und keine ausgeprägten Interfacebereiche zum Substrat und zur Oberfläche hin aufweisen. Die XPS-Analysen deuten darauf hin, dass Verkettungsreaktionen von CF2-Radikalen im Plasma eine wichtige Rolle für den Schichtbildungsprozess spielen. Weiterhin konnte gezeigt werden, dass der gewählte Beschichtungsprozess eine gezielte Reduzierung der Benetzbarkeit verschiedener Substrate ermöglicht. Dabei genügen Schichtdicken von weniger als 3 nm zur Erreichung eines teflonartigen Oberflächencharakters mit Oberflächenenergien um 20 mN/m. Damit erschließen sich neue Applikationsmöglichkeiten ultra-dünner Fluorkohlenstoffschichten, was anhand eines Beispiels aus dem Bereich der Nanooptik demonstriert wird. Für die siliziumorganischen Schichten unter Verwendung des Monomers Hexamethyldisiloxan (HMDSO) galt es zunächst, diejenigen Prozessparameter zu identifizieren, die ihren organischen bzw. glasartigen Charakter bestimmen. Hierzu wurde der Einfluss von Leistungseintrag und Zugabe von Sauerstoff als Reaktivgas auf die Elementzusammensetzung der Schichten untersucht. Bei niedrigen Plasmaleistungen und Sauerstoffflüssen werden vor allem kohlenstoffreiche Schichten abgeschieden, was auf eine geringere Fragmentierung der Kohlenwasserstoffgruppen zurückgeführt wurde. Es zeigte sich, dass die Variation des Sauerstoffanteils im Prozessgas eine sehr genaue Steuerbarkeit der Schichteigenschaften ermöglicht. Mittels Sekundär-Neutralteilchen-Massenspektrometrie (SNMS) konnte die prozesstechnische Realisierbarkeit und analytische Quantifizierbarkeit von Wechselschichtsystemen aus polymerartigen und glasartigen Lagen demonstriert werden. Aus dem Intensitätsverhältnis von Si:H-Molekülen zu Si-Atomen im SNMS-Spektrum ließ sich der Wasserstoffgehalt bestimmen. Weiterhin konnte gezeigt werden, dass durch Abscheidung von HMDSO-basierten Gradientenschichten eine deutliche Reduzierung von Reibung und Verschleiß bei Elastomerbauteilen erzielt werden kann.
A new double laser pulse pumping scheme for transient collisionally excited plasma soft X-ray lasers
Resumo:
Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn