14 resultados para Angular-Momentum
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1
Resumo:
In dieser Arbeit wird zum Erreichen hoher Kernspinpolarisationen die Methode des metastabilen optischen Pumpens benutzt. Das Verfahren beruht auf dem "Ubertrag des Drehimpulses absorbierter Photonen auf das hierbei angeregte Valenzelektron, welches durch Hyperfeinkopplung den Drehimpuls weiter auf den $^3$He-Kern transferiert. Da der Polarisationsprozess nur bei Dr"ucken von ca. 1~mbar effizient funktioniert, f"ur die meisten Anwendungen aber polarisiertes $^3$He bei einem Druck von $geq 1$~bar ben"otigt wird, muss das Gas nach der Aufpolarisation komprimiert werden. In unserer Arbeitsgruppe steht eine Maschine ("`Polarisator"') zur Verf"ugung, die das Gas polarisiert und anschlie"send komprimiert. Ziel dieser Dissertation ist, einerseits die Leistungsf"ahigkeit des Polarisators bez"uglich Maximalpolarisation und Gasfluss zu verbessern und andererseits den metastabilen Pumpprozess selbst genauer zu untersuchen.\ noindent Durch die Verwendung neuer Laser auf Basis der Fasertechnologie sowie einer systematischen Optimierung der optischen Komponenten konnten in abgeschlossenen Pumpzellen Rekord-Polarisationsgrade von $91pm 2$% erzielt werden.\ noindent Mit der Implementierung neuartiger Optiken und Laser am Mainzer Polarisator konnte die Leistungscharakteristik entscheidend verbessert werden. So wurde die erreichbare Polarisation bei identischer Produktionsrate um 20 Prozentpunkte gesteigert. Zurzeit sind maximale Polarisationsgrade von mehr als 75% im optischen Pumpvolumen erreichbar. Eine am Mainzer Triga-Reaktor durchgef"uhrte Polarisationsbestimmung ergab einen Wert von $72.7pm 0.7$%. Dies veranschaulicht die geringen Polarisationsverluste infolge der Gaskompression, des Transports und einer Lagerung "uber mehrere Stunden.\ noindent Zur Dynamik der geschwindigkeitsver"andernden St"o"se sowie zur Bestimmung der mittleren Photonen-Absorptionsrate wurde ein Modell entwickelt, welches auch experimentell best"atigt wurde. Damit konnte erstmalig das gemessene Absorptionsverhalten einer spektral schmalbandigen Laserdiode korrekt beschrieben werden.\ noindent Zudem stimmen die an so genannten abgeschlossenen Pumpzellen gemessenen extrem hohen Polarisationswerte mit theoretischen Vorhersagen "uberein, sofern der Druck im optischen Pumpvolumen geringer als 1~mbar ist und das $^3$He nicht durch Fremdgase verunreinigt ist. Bei derartigen Pumpzellen ist die gemessene Abh"angigkeit der Polarisation von Laserleistung, Metastabilendichte und falscher Zirkularkomponente mit der Theorie kompatibel.\
Resumo:
The aim of this work is to explore, within the framework of the presumably asymptotically safe Quantum Einstein Gravity, quantum corrections to black hole spacetimes, in particular in the case of rotating black holes. We have analysed this problem by exploiting the scale dependent Newton s constant implied by the renormalization group equation for the effective average action, and introducing an appropriate "cutoff identification" which relates the renormalization scale to the geometry of the spacetime manifold. We used these two ingredients in order to "renormalization group improve" the classical Kerr metric that describes the spacetime generated by a rotating black hole. We have focused our investigation on four basic subjects of black hole physics. The main results related to these topics can be summarized as follows. Concerning the critical surfaces, i.e. horizons and static limit surfaces, the improvement leads to a smooth deformation of the classical critical surfaces. Their number remains unchanged. In relation to the Penrose process for energy extraction from black holes, we have found that there exists a non-trivial correlation between regions of negative energy states in the phase space of rotating test particles and configurations of critical surfaces of the black hole. As for the vacuum energy-momentum tensor and the energy conditions we have shown that no model with "normal" matter, in the sense of matter fulfilling the usual energy conditions, can simulate the quantum fluctuations described by the improved Kerr spacetime that we have derived. Finally, in the context of black hole thermodynamics, we have performed calculations of the mass and angular momentum of the improved Kerr black hole, applying the standard Komar integrals. The results reflect the antiscreening character of the quantum fluctuations of the gravitational field. Furthermore we calculated approximations to the entropy and the temperature of the improved Kerr black hole to leading order in the angular momentum. More generally we have proven that the temperature can no longer be proportional to the surface gravity if an entropy-like state function is to exist.
Resumo:
Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.
Resumo:
Das in dieser Arbeit vorgestellte Experiment zur Messung des magnetischen Moments des Protons basiert auf der Messung des Verhältnisses von Zyklotronfrequenz und Larmorfrequenz eines einzelnen, in einer kryogenen Doppel-Penning Falle gespeicherten Protons. In dieser Arbeit konnten erstmalig zwei der drei Bewegungsfrequenzen des Protons gleichzeitig im thermischen Gleichgewicht mit entsprechenden hochsensitiven Nachweissystemen nicht-destruktiv detektiert werden, wodurch die Messzeit zur Bestimmung der Zyklotronfrequenz halbiert werden konnte. Ferner wurden im Rahmen dieser Arbeit erstmalig einzelne Spin-Übergänge eines einzelnen Protons detektiert, wodurch die Bestimmung der Larmorfrequenz ermöglicht wird. Mithilfe des kontinuierlichen Stern-Gerlach Effekts wird durch eine sogenannte magnetische Flasche das magnetische Moment an die axiale Bewegungsmode des Protons gekoppelt. Eine Änderung des Spinzustands verursacht folglich einen Frequenzsprung der axialen Bewegungsfrequenz, welche nicht-destruktiv gemessen werden kann. Erschwert wird die Detektion des Spinzustands dadurch, dass die axiale Frequenz nicht nur vom Spinmoment, sondern auch vom Bahnmoment abhängt. Die große experimentelle Herausforderung besteht also in der Verhinderung von Energieschwankungen in den radialen Bewegungsmoden, um die Detektierbarkeit von Spin-Übergängen zu gewährleisten. Durch systematische Studien zur Stabilität der axialen Frequenz sowie einer kompletten Überarbeitung des experimentellen Aufbaus, konnte dieses Ziel erreicht werden. Erstmalig kann der Spinzustand eines einzelnen Protons mit hoher Zuverlässigkeit bestimmt werden. Somit stellt diese Arbeit einen entscheidenden Schritt auf dem Weg zu einer hochpräzisen Messung des magnetischen Moments des Protons dar.
Resumo:
Die Drei-Spektrometer-Anlage am Mainzer Institut für Kernphysik wurde um ein zusätzliches Spektrometer ergänzt, welches sich durch seine kurze Baulänge auszeichnet und deshalb Short-Orbit-Spektrometer (SOS) genannt wird. Beim nominellen Abstand des SOS vom Target (66 cm) legen die nachzuweisenden Teilchen zwischen Reaktionsort und Detektor eine mittlere Bahnlänge von 165 cm zurück. Für die schwellennahe Pionproduktion erhöht sich dadurch im Vergleich zu den großen Spektrometern die Überlebenswahrscheinlichkeit geladener Pionen mit Impuls 100 MeV/c von 15% auf 73%. Demzufolge verringert sich der systematische Fehler ("Myon-Kontamination"), etwa bei der geplanten Messung der schwachen Formfaktoren G_A(Q²) und G_P(Q²), signifikant. Den Schwerpunkt der vorliegenden Arbeit bildet die Driftkammer des SOS. Ihre niedrige Massenbelegung (0,03% X_0) zur Reduzierung der Kleinwinkelstreuung ist auf den Nachweis niederenergetischer Pionen hin optimiert. Aufgrund der neuartigen Geometrie des Detektors musste eine eigene Software zur Spurrekonstruktion, Effizienzbestimmung etc. entwickelt werden. Eine komfortable Möglichkeit zur Eichung der Driftweg-Driftzeit-Relation, die durch kubische Splines dargestellt wird, wurde implementiert. Das Auflösungsvermögen des Spurdetektors liegt in der dispersiven Ebene bei 76 µm für die Orts- und 0,23° für die Winkelkoordinate (wahrscheinlichster Fehler) sowie entsprechend in der nicht-dispersiven Ebene bei 110 µm bzw. 0,29°. Zur Rückrechnung der Detektorkoordinaten auf den Reaktionsort wurde die inverse Transfermatrix des Spektrometers bestimmt. Hierzu wurden an Protonen im ¹²C-Kern quasielastisch gestreute Elektronen verwendet, deren Startwinkel durch einen Lochkollimator definiert wurden. Daraus ergeben sich experimentelle Werte für die mittlere Winkelauflösung am Target von sigma_phi = 1,3 mrad bzw. sigma_theta = 10,6 mrad. Da die Impulseichung des SOS nur mittels quasielastischer Streuung (Zweiarmexperiment) durchgeführt werden kann, muss man den Beitrag des Protonarms zur Breite des Piks der fehlenden Masse in einer Monte-Carlo-Simulation abschätzen und herausfalten. Zunächst lässt sich nur abschätzen, dass die Impulsauflösung sicher besser als 1% ist.
Resumo:
In dieser Arbeit werden die QCD-Strahlungskorrekturen in erster Ordnung der starken Kopplungskonstanten für verschiedene Polarisationsobservablen zu semileptonischen Zerfällen eines bottom-Quarks in ein charm-Quark und ein Leptonpaar berechnet. Im ersten Teil wird der Zerfall eines unpolarisierten b-Quarks in ein polarisiertes c-Quark sowie ein geladenes Lepton und ein Antineutrino im Ruhesystem des b-Quarks analysiert. Es werden die Strahlungskorrekturen für den unpolarisierten und den polarisierten Beitrag zur differentiellen Zerfallsrate nach der Energie des c-Quarks berechnet, wobei das geladene Lepton als leicht angesehen und seine Masse daher vernachlässigt wird. Die inklusive differentielle Rate wird durch zwei Strukturfunktionen in analytischer Form dargestellt. Anschließend werden die Strukturfunktionen und die Polarisation des c-Quarks numerisch ausgewertet. Nach der Einführung der Helizitäts-Projektoren befaßt sich der zweite Teil mit dem kaskadenartigen Zerfall eines polarisierten b-Quarks in ein unpolarisiertes c-Quark und ein virtuelles W-Boson, welches weiter in ein Paar leichter Leptonen zerfällt. Es werden die inklusiven Strahlungskorrekturen zu drei unpolarisierten und fünf polarisierten Helizitäts-Strukturfunktionen in analytischer Form berechnet, welche die Winkelverteilung für die differentielle Zerfallsrate nach dem Viererimpulsquadrat des W-Bosons beschreiben. Die Strukturfunktionen enthalten die Informationen sowohl über die polare Winkelverteilung zwischen dem Spinvektor des b-Quarks und dem Impulsvektor des W-Bosons als auch über die räumliche Winkelverteilung zwischen den Impulsen des W-Bosons und des Leptonpaars. Der Impuls und der Spinvektor des b-Quarks sowie der Impuls des W-Bosons werden im b-Ruhesystem analysiert, während die Impulse des Leptonpaars im W-Ruhesystem ausgewertet werden. Zusätzlich zu den genannten Strukturfunktionen werden noch die unpolarisierte und die polarisierte skalare Strukturfunktion angegeben, die in Anwendungen bei hadronischen Zerfällen eine Rolle spielen. Anschließend folgt eine numerische Auswertung aller berechneten Strukturfunktionen. Im dritten Teil werden die nichtperturbativen HQET-Korrekturen zu inklusiven semileptonischen Zerfällen schwerer Hadronen diskutiert, welche ein b-Quark enthalten. Sie beschreiben hadronische Korrekturen, die durch die feste Bindung des b-Quarks in Hadronen hervorgerufen werden. Es werden insgesamt fünf unpolarisierte und neun polarisierte Helizitäts-Strukturfunktionen in analytischer Form angegeben, die auch eine endliche Masse und den Spin des geladenen Leptons berücksichtigen. Die Strukturfunktionen werden sowohl in differentieller Form in Abhängigkeit des quadrierten Viererimpulses des W-Bosons als auch in integrierter Form präsentiert. Zum Schluß werden die zuvor erhaltenen Resultate auf die semi-inklusiven hadronischen Zerfälle eines polarisierten Lambda_b-Baryons oder eines B-Mesons in ein D_s- oder ein D_s^*-Meson unter Berücksichtigung der D_s^*-Polarisation angewandt. Für die zugehörigen Winkelverteilungen werden die inklusiven QCD- und die nichtperturbativen HQET-Korrekturen zu den Helizitäts-Strukturfunktionen in analytischer Form angegeben und anschließend numerisch ausgewertet.
Resumo:
In this thesis I concentrate on the angular correlations in top quark decays and their next--to--leading order (NLO) QCD corrections. I also discuss the leading--order (LO) angular correlations in unpolarized and polarized hyperon decays. In the first part of the thesis I calculate the angular correlation between the top quark spin and the momentum of decay products in the rest frame decay of a polarized top quark into a charged Higgs boson and a bottom quark in Two-Higgs-Doublet-Models: $t(uparrow)rightarrow b+H^{+}$. The decay rate in this process is split into an angular independent part (unpolarized) and an angular dependent part (polar correlation). I provide closed form formulae for the ${mathcal O}(alpha_{s})$ radiative corrections to the unpolarized and the polar correlation functions for $m_{b}neq 0$ and $m_{b}=0$. The results for the unpolarized rate agree with the existing results in the literature. The results for the polarized correlations are new. I found that, for certain values of $tanbeta$, the ${mathcal O}(alpha_s)$ radiative corrections to the unpolarized, polarized rates, and the asymmetry parameter can become quite large. In the second part I concentrate on the semileptonic rest frame decay of a polarized top quark into a bottom quark and a lepton pair: $t(uparrow) to X_b + ell^+ + nu_ell$. I analyze the angular correlations between the top quark spin and the momenta of the decay products in two different helicity coordinate systems: system 1a with the $z$--axis along the charged lepton momentum, and system 3a with the $z$--axis along the neutrino momentum. The decay rate then splits into an angular independent part (unpolarized), a polar angle dependent part (polar correlation) and an azimuthal angle dependent part (azimuthal correlation). I present closed form expressions for the ${mathcal O}(alpha_{s})$ radiative corrections to the unpolarized part and the polar and azimuthal correlations in system 1a and 3a for $m_{b}neq 0$ and $m_{b}=0$. For the unpolarized part and the polar correlation I agree with existing results. My results for the azimuthal correlations are new. In system 1a I found that the azimuthal correlation vanishes in the leading order as a consequence of the $(V-A)$ nature of the Standard Model current. The ${mathcal O}(alpha_{s})$ radiative corrections to the azimuthal correlation in system 1a are very small (around 0.24% relative to the unpolarized LO rate). In system 3a the azimuthal correlation does not vanish at LO. The ${mathcal O}(alpha_{s})$ radiative corrections decreases the LO azimuthal asymmetry by around 1%. In the last part I turn to the angular distribution in semileptonic hyperon decays. Using the helicity method I derive complete formulas for the leading order joint angular decay distributions occurring in semileptonic hyperon decays including lepton mass and polarization effects. Compared to the traditional covariant calculation the helicity method allows one to organize the calculation of the angular decay distributions in a very compact and efficient way. This is demonstrated by the specific example of the polarized hyperon decay $Xi^0(uparrow) to Sigma^+ + l^- + bar{nu}_l$ ,($l^-=e^-, mu^-$) followed by the nonleptonic decay $Sigma^+ to p + pi^0$, which is described by a five--fold angular decay distribution.
Resumo:
Mit der Erweiterung des Elektronenbeschleunigers MAMI um eine dritte Stufe ist es möglich geworden, am Institut für Kernphysik Teilchen mit offener Strangeness zu produzieren. Für deren Nachweis ist die Drei-Spektrometeranlage der Kollaboration A1 um das von der GSI in Darmstadt übernommene KAOS-Spektrometer erweitert worden. Untersucht wird damit die elementare Reaktion p(e,e' K+)Lambda/Sigma0 wobei das auslaufende Elektron und das Kaon nachgewiesen werden müssen. Wird als Target nicht Wasserstoff verwendet, besteht die Möglichkeit dass sich ein Hyperkern bildet. Spektroskopische Untersuchungen an diesen bieten die Möglichkeit das Potential von Hyperonen in Atomkernen und die Hyperon-Nukleon-Wechselwirkung zu untersuchen. Aufgrund der hervorragenden Strahlqualität bei der Elektroproduktion können hier Massenauflösungen von einigen hundert keV/c² erreicht werden. Mit Hilfe von GEANT4 wurden die Detektoren und die Abbildungseigenschaften des Spektrometers simuliert. Geeignete Ereignisgeneratoren wurden implementiert. Es wurde untersucht, wie mögliche Treffermuster in den Detektoren aussehen, die von einem Trigger auf FPGA-Basis selektiert werden müssen. Ebenso konnte hieraus eine erste Abbildung der Spurkoordinaten auf die Targetkoordinaten und den Teilchenimpuls gewonnen werden. Für das Hyperkernprogramm muss KAOS unter 0° Vorwärtsrichung betrieben werden und der Primärstrahl mit Hilfe einer Schikane durch den Dipol gelenkt werden. Die Simulation zeigt hier eine nur moderate Erhöhung der Strahlenbelastung, vor allem im Bereich des Strahlfängers. Somit ist es möglich, KAOS als doppelseitiges Spektrometer in der Spektrometerhalle zu betreiben. Im Rahmen dieser Arbeit wurden die für sämtliche Detektoren nötige Auslese- und Steuerungselektronik in das vorhandene Datenerfassungssystem und das Steuerungssystem eingebunden. In zwei Strahlzeiten im Herbst 2008 wurden Kaonen im Winkelbereich von 20°-40° mit Impulsen zwischen 400MeV/c und 600MeV/c nachgewiesen. Die aus der Simulation gewonnenen Daten zum Trigger und zur Abbildung kamen zum Einsatz. Es konnte die für eine gute Teilchenidentifikation nötige Zeitauflösung von ca. 1ns FWHM erreicht werden. Die erreichte Winkel- und Impulsauflösung war ausreichend um Lambda und Sigma0-Hyperonen im Spektrum der fehlenden Masse leicht trennen zu können.
Resumo:
Am COMPASS-Experiment am CERN-SPS wird die Spinsstruktur des Nukleons mit Hilfe der Streuung von polarisierten Myonen an polarisierten Nukleonen untersucht. Der in der inklusiven tiefinelastischen Streuung gemessene Beitrag der Quarks zum Nukleonspin reicht nicht aus, um den Spin des Nukleons zu erklären. Daher soll geklärt werden, wie die Gluonpolarisation und die Bahndrehimpulse von Quarks und Gluonen zum Gesamtspin des Nukleons beitragen. Da sich die Gluonpolarisation aus der $Q^{2}$-Abhängigkeit der Asymmetrien in der inklusiven Streuung nur abschätzen lässt, wird eine direkte Messung der Gluonpolarisation benötigt. Die COMPASS-Kollaboration bestimmt daher die Wirkungsquerschnittsasymmetrien für Photon-Gluon-Fusionprozesse, indem sie zum einen die offene Charmproduktion und zum anderen die Produktion von Hadronpaaren mit großen Transversalimpulsen verwendet. In dieser Arbeit wird die Messung der Gluonpolarisation mit den COMPASS-Daten der Jahre 2003 und 2004 vorgestellt. Für die Analyse werden die Ereignisse mit großem Impulsübertrag ($Q^{2}>1$ $GeV^{2}/c^{2}$) und mit Hadronpaaren mit großem Transversalimpuls ($p_{perp}>0.7$ $GeV/c$) verwendet. Die Photon-Nukleon-Asymmetrie wurde aus dem gewichteten Doppelverhältnis der selektierten Ereignisse bestimmt. Der Schnitt auf $p_{perp}>0.7$rn$GeV/c$ unterdrückt die Prozesse führender Ordnung und QCD-Compton Prozesse, so dass die Asymmetrie direkt mit der Gluonpolarisation über die Analysierstärke verknüpft ist. Der gemessene Wert ist sehr klein und verträglich mit einer verschwindenden Gluonpolarisation. Zur Vermeidung von falschen Asymmetrien aufgrund der Änderung der Detektorakzeptanz wurden Doppelverhältnisse untersucht, bei denen sich der Wirkungsquerschnitt aufhebt und nur die Detektorasymmetrien übrig bleiben. Es konnte gezeigt werden, dass das COMPASS-Spektrometer keine signifikante Zeitabhängigkeit aufweist. Für die Berechnung der Analysierstärke wurden Monte Carlo Ereignisse mit Hilfe des LEPTO-Generators und des COMGeant Software Paketes erzeugt. Dabei ist eine gute Beschreibung der Daten durch das Monte Carlo sehr wichtig. Dafür wurden zur Verbesserung der Beschreibung JETSET Parameter optimiert. Es ergab sich ein Wert von rn$frac{Delta G}{G}=0.054pm0.145_{(stat)}pm0.131_{(sys)}pm0.04_{(MC)}$ bei einem mittleren Impulsbruchteil von $langle x_{gluon}rangle=0.1$ und $langle Q^{2}rangle=1.9$ $GeV^{2}/c^{2}$. Dieses Ergebnis deutet auf eine sehr kleine Gluonpolarisation hin und steht im Einklang mit den Ergebnissen anderer Methoden, wie offene Charmproduktion und mit den Ergebnissen, die am doppelt polarisierten RHIC Collider am BNL erzielt wurden.
Resumo:
The beta-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient "a". A first test period (2005/ 2006) showed the “proof-of-principles”. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient "a" (publication: Baessler et al., 2008, Europhys. Journ. A, 38, p.17-26). A second measurement cycle (2007/ 2008) aimed to under-run the relative accuracy of previous experiments (Stratowa et al. (1978), Byrne et al. (2002)) da/a =5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to da/a(syst.)=0.61 %. The statistical accuracy of the analyzed measurements is da/a(stat.)=1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects will be discussed in the last chapter.
Resumo:
The availability of a high-intensity antiproton beam with momentum up to 15,GeV/c at the future FAIR will open a unique opportunity to investigate wide areas of nuclear physics with the $overline{P}$ANDA (anti{$overline{P}$}roton ANnihilations at DArmstadt) detector. Part of these investigations concern the Electromagnetic Form Factors of the proton in the time-like region and the study of the Transition Distribution Amplitudes, for which feasibility studies have been performed in this Thesis. rnMoreover, simulations to study the efficiency and the energy resolution of the backward endcap of the electromagnetic calorimeter of $overline{P}$ANDA are presented. This detector is crucial especially for the reconstruction of processes like $bar pprightarrow e^+ e^- pi^0$, investigated in this work. Different arrangements of dead material were studied. The results show that both, the efficiency and the energy resolution of the backward endcap of the electromagnetic calorimeter fullfill the requirements for the detection of backward particles, and that this detector is necessary for the reconstruction of the channels of interest. rnrnThe study of the annihilation channel $bar pprightarrow e^+ e^-$ will improve the knowledge of the Electromagnetic Form Factors in the time-like region, and will help to understand their connection with the Electromagnetic Form Factors in the space-like region. In this Thesis the feasibility of a measurement of the $bar pprightarrow e^+ e^-$ cross section with $overline{P}$ANDA is studied using Monte-Carlo simulations. The major background channel $bar pprightarrow pi^+ pi^-$ is taken into account. The results show a $10^9$ background suppression factor, which assure a sufficiently clean signal with less than 0.1% background contamination. The signal can be measured with an efficiency greater than 30% up to $s=14$,(GeV/c)$^2$. The Electromagnetic Form Factors are extracted from the reconstructed signal and corrected angular distribution. Above this $s$ limit, the low cross section will not allow the direct extraction of the Electromagnetic Form Factors. However, the total cross section can still be measured and an extraction of the Electromagnetic Form Factors is possible considering certain assumptions on the ratio between the electric and magnetic contributions.rnrnThe Transition Distribution Amplitudes are new non-perturbative objects describing the transition between a baryon and a meson. They are accessible in hard exclusive processes like $bar pprightarrow e^+ e^- pi^0$. The study of this process with $overline{P}$ANDA will test the Transition Distribution Amplitudes approach. This work includes a feasibility study for measuring this channel with $overline{P}$ANDA. The main background reaction is here $bar pprightarrow pi^+ pi^- pi^0$. A background suppression factor of $10^8$ has been achieved while keeping a signal efficiency above 20%.rnrnrnPart of this work has been published in the European Physics Journal A 44, 373-384 (2010).rn
Resumo:
Während der letzten Jahre wurde für Spinfilter-Detektoren ein wesentlicher Schritt in Richtung stark erhöhter Effizienz vollzogen. Das ist eine wichtige Voraussetzung für spinaufgelöste Messungen mit Hilfe von modernen Elektronensp ektrometern und Impulsmikroskopen. In dieser Doktorarbeit wurden bisherige Arbeiten der parallel abbildenden Technik weiterentwickelt, die darauf beruht, dass ein elektronenoptisches Bild unter Ausnutzung der k-parallel Erhaltung in der Niedrigenergie-Elektronenbeugung auch nach einer Reflektion an einer kristallinen Oberfläche erhalten bleibt. Frühere Messungen basierend auf der spekularen Reflexion an einerrnW(001) Oberfläche [Kolbe et al., 2011; Tusche et al., 2011] wurden auf einenrnviel größeren Parameterbereich erweitert und mit Ir(001) wurde ein neues System untersucht, welches eine sehr viel längere Lebensdauer der gereinigten Kristalloberfläche im UHV aufweist. Die Streuenergie- und Einfallswinkel-“Landschaft” der Spinempfindlichkeit S und der Reflektivität I/I0 von gestreuten Elektronen wurde im Bereich von 13.7 - 36.7 eV Streuenergie und 30◦ - 60◦ Streuwinkel gemessen. Die dazu neu aufgebaute Messanordnung umfasst eine spinpolarisierte GaAs Elektronenquellernund einen drehbaren Elektronendetektor (Delayline Detektor) zur ortsauflösenden Detektion der gestreuten Elektronen. Die Ergebnisse zeigen mehrere Regionen mit hoher Asymmetrie und großem Gütefaktor (figure of merit FoM), definiert als S2 · I/I0. Diese Regionen eröffnen einen Weg für eine deutliche Verbesserung der Vielkanal-Spinfiltertechnik für die Elektronenspektroskopie und Impulsmikroskopie. Im praktischen Einsatz erwies sich die Ir(001)-Einkristalloberfläche in Bezug auf längere Lebensdauer im UHV (ca. 1 Messtag), verbunden mit hoher FOM als sehr vielversprechend. Der Ir(001)-Detektor wurde in Verbindung mit einem Halbkugelanalysator bei einem zeitaufgelösten Experiment im Femtosekunden-Bereich am Freie-Elektronen-Laser FLASH bei DESY eingesetzt. Als gute Arbeitspunkte erwiesen sich 45◦ Streuwinkel und 39 eV Streuenergie, mit einer nutzbaren Energiebreite von 5 eV, sowie 10 eV Streuenergie mit einem schmaleren Profil von < 1 eV aber etwa 10× größerer Gütefunktion. Die Spinasymmetrie erreicht Werte bis 70 %, was den Einfluss von apparativen Asymmetrien deutlich reduziert. Die resultierende Messungen und Energie-Winkel-Landschaft zeigt recht gute Übereinstimmung mit der Theorie (relativistic layer-KKR SPLEED code [Braun et al., 2013; Feder et al.,rn2012])
Resumo:
The experiments at the Large Hadron Collider at the European Centre for Particle Physics, CERN, rely on efficient and reliable trigger systems for singling out interesting events. This thesis documents two online timing monitoring tools for the central trigger of the ATLAS experiment as well as the adaption of the central trigger simulation as part of the upgrade for the second LHC run. Moreover, a search for candidates for so-called Dark Matter, for which there is ample cosmological evidence, is presented. This search for generic weakly interacting massive particles (WIMPs) is based on the roughly 20/fb of proton-proton collisions at a centre-of-mass-energy of sqrt{s}=8 TeV recorded with the ATLAS detector in 2012. The considered signature are events with a highly energetic jet and large missing transverse energy. No significant deviation from the theory prediction is observed. Exclusion limits are derived on parameters of different signal models and compared to the results of other experiments. Finally, the results of a simulation study on the potential of the analysis at sqrt{s}=14 TeV are presented.