11 resultados para Absolute quantification

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis focused on the polymer’s influence on the interaction of polymeric NPs with epithelial cells. Furthermore, the measurement of single submicron nanoparticles in a commercially available flow cytometer was established, to provide a new method in the toolbox for nanoparticle-cell studies. This gave way to develop a routine for the absolute quantification of intracellular NPs via flow cytometry. rnThe cellular uptake of poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(L-lactide) (PLLA) nanoparticles was investigated via flow cytometry. PLLA-NPs were internalized the most efficiently. But upon co-incubation of PS and PLLA particles with cells, the two particles mutually influenced their uptake, slightly shifting the relative uptake efficiencies. This phenomenon should be based on specific properties of the different polymer materials. The findings indicated a competition (which is strongly influenced by properties of the respective polymeric material) for the uptake into the cells, allegedly due to competition for specific coatings with serum components that enhances the NPs’ cellular uptake. The fluorescence of single 150 nm particles was determined with a benchtop cytometer, breaching the machine’s detection limit but yielding precise NP fluorescence standardization factors. Up to now, these standardization factors are mostly determined by spectroscopic analysis of the particles’ dye content. Finally a flow cytometric routine for absolute particle counting in cells was devised. This quantitation revealed a low uptake efficiency for un-functionalized PMMA NPs of less than 150 NPs (approx. 0,001 % of added) per cell.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die regionale Bestimmung der Durchblutung (Perfusion) ermöglicht differenzierte Aussagen über den Gesundheitszustand und die Funktionalität der Lunge. Durch neue Messverfahren ermöglicht die Magnetresonanztomographie (MRT) eine nicht-invasive und strahlungsfreie Untersuchung der Perfusion. Obwohl die Machbarkeit qualitativer MRT-Durchblutungsmessungen bereits gezeigt wurde, fehlt bisher eine validierte quantitative Methode. Ziel dieser Arbeit war eine Optimierung der bestehenden Messprotokolle und mathematischen Modelle zur Absolutquantifizierung der Lungenperfusion mit Magnetresonanztomographie. Weiterhin sollte die Methodik durch Vergleich mit einem etablierten Referenzverfahren validiert werden. Durch Simulationen und Phantommessungen konnten optimale MRT-Messparameter und ein standardisiertes Protokoll festgelegt werden. Des Weiteren wurde eine verallgemeinerte Bestimmung der Kontrastmittelkonzentration aus den gemessenen Signalintensitäten vorgestellt, diskutiert und durch Probandenmessungen validiert. Auf der Basis dieser Entwicklungen wurde die MRT-Durchblutungsmessung der Lunge tierexperimentell mit der Positronenemissionstomographie (PET) intraindividuell verglichen und validiert. Die Ergebnisse zeigten nur kleine Abweichungen und eine statistisch hochsignifikante, stark lineare Korrelation. Zusammenfassend war es durch die Entwicklungen der vorgestellten Arbeit möglich, die kontrastmittelgestützte MRT-Durchblutungsmessung der Lunge zu optimieren und erstmals zu validieren.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ZusammenfassungrnDie häufigsten Todesfälle weltweit sind auf Herzerkrankungen zurückzuführen. Bei der koronaren Herzkrankheit (KHK) sammeln sich über Jahre arteriosklerotische Ablagerungen in den Herzkranzgefäßen an und führen so zu einer verminderten Durchblutung und Versorgung des Herzmuskelgewebes mit Sauerstoff und Nährstoffen. Zur nuklearmedizinischen Bildgebung finden am häufigsten das SPECT-Nuklid 201Tl sowie die beiden 99mTc-Radiopharmaka Sestamibi und Tetrofosmin Anwendung. Die PET-Technik ist der SPECT-Technik in Bezug auf absolute Quantifizierung sowie Auflösung überlegen. Ziel der vorliegenden Arbeit war es, ein mögliches PET-Radiopharmakon zur Diagnostik der KHK zu entwickeln. Um eine dem 99mTc-Nuklid vergleichbare Verfügbarkeit im klinischen Alltag zu erreichen, sollte als Basis des neuen Radiopharmakons das mittels Radionuklid-Generator verfügbare 68Ga dienen. Schiff’sche Basen-Verbindungen zeigten nach Komplexierung mit 67/68Ga eine deutliche Aufnahme in die Herzmuskelzellen. Auf dieser Grundlage wurden verschiedene Schiff’sche Basen-Strukturen synthetisiert. Diese unterscheiden sich einerseits durch das Substitutionsmuster der verwendeten Aldehyde und andererseits durch das verwendete Rückgrat. Alle synthetisierten Chelatoren wurden erfolgreich mit 68Ga radioaktiv markiert und konnten anschließend aufgereinigt werden. Die Evaluierung dieser Substanzen in vitro zeigte, dass sie in unterschiedlichen Medien stabil ist. Die Lipophilie der 68Ga-Verbindungen (log D) lag zwischen 0,87±0,24 und 2,72±0,14. Die Ladung der Verbindungen wurde mittels Papierelektrophorese bei pH= 7 als kationisch bestimmt. Zusätzlich fanden in vitro-Untersuchungen zur Bestimmung der Aufnahme der Komplexe in HL-1 Herzzellen statt. Um den Einfluss des Zellmembranpotentials bzw. des Mitochondrienmembranpotentials zu untersuchen, wurde ein Teil der Zellen dafür mit Valinomycin (Ionophor, zerstört das Potential) behandelt. Mittels ex vivo-Biodistributionen wurde die Organverteilung von zwei Schiff’schen Basen (68Ga-BADED-2 und 68Ga-BAPDMEN-2) mit dem routinemäßig in der Klinik eingesetzten Derivat 99mTc-Sestamibi sowie dem 18F-Flurpiridaz in Ratten verglichen. Alle Verbindungen zeigten dabei eine deutliche Herzaufnahme von mehr als 2 % der injizierten Dosis pro Gramm Gewebe. Durch in vivo-PET-Aufnahmen wurden die Zeit-Aktivitätskurven der 68Ga-Verbindungen sowie zum Vergleich des 18F-Flurpiridaz bestimmt. Die Aufnahmen lagen im Bereich von 0,63±0,15 für 68Ga-BAPEN-3 bis 2,72±0,86 für 68Ga-BADED-8.In dem zweiten Teil der Arbeit wurden die Vorteile des hochaffinen Herztracers Flurpiridaz mit dem lipophilen, positiv-geladenen Ga-Schiff’sche Base-Chelator kombiniert. Hierzu wurde zunächst das Insektizid Flurpiridaz synthetisiert und mit dem BAPEN-Rückgrat gekoppelt. Die entstandene Verbindung wurde erstmals mit 68Ga radioaktiv markiert und muss in weiterführenden Arbeiten evaluiert werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Zusammenfassung:In dieser Studie werden Deformationsprozesse im mesozoischen Torlesse Akkretionskeil (Neuseeland) quantifiziert, um Aufschluß über die Dynamik in Akkretionskeilen zu erhalten. Absolute und relative Verformungsmessungen zeigen sowohl im lokalen als auch regionalen Maßstab eine stark heterogene Deformation des Torlesse Keils. Die regionale Deformation wurde mit Hilfe einer Tensordurchschnittsberechnung, unter Benutzung einzelner lokaler Verformungsdaten, als uniaxiale Verkürzung entlang einer subvertikalen, maximalen Verkürzungsachse charakterisiert. Absolute Verformungsmessungen an niedriggradigen Metasandsteinen belegen darüber hinaus durchschnittliche Volumenverluste von ca. 20% SiO2. Volumenveränderungen in tieferkrustalen Aufschlüssen wurden mittels einer geochemischen Massenbilanzanalyse abgeschätzt. Chemische Zusammensetzungen höhergradiger Zonen weichen je nach Grad der Volumenverformung von der Protolitzusammensetzung ab und zeigen somit Verluste von 15% SiO2 an. Da Speicherorte für das gelöste Material nicht bekannt sind, muss angenommen werden, dass das Material aus dem Keil abtransportiert wurde. Die Verformungsergebnisse geben weiterhin Aufschluß über den Grad der Kopplung zwischen Akkretionskeil und subduzierter Platte. Die ermittelten Scherwerte in den Gesteinen liegen deutlich unter den zu erwartenden Scherwerten, die mittels eines einfachen Modells berechnet wurden, das sowohl verschiedene Konvergenzgeschwindigkeiten als auch Exhumierungsraten berücksichtigt. Dies belegt, dass der Torlesse Keil stark von der subduzierten pazifischen Platte entkoppelt war und die Deformation hauptsächlich durch den Fluß der Sedimente in und aus dem Keil bestimmt wurde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) wird zur individuellen Dosiseinstellung genutzt, um die Effizienz der Medikamentenwirkung zu steigern und das Auftreten von Nebenwirkungen zu senken. Für das TDM von Antipsychotika und Antidepressiva besteht allerdings das Problem, dass es mehr als 50 Medikamente gibt. Ein TDM-Labor muss dementsprechend über 50 verschiedene Wirkstoffe und zusätzlich aktive Metaboliten messen. Mit der Flüssigchromatographie (LC oder HPLC) ist die Analyse vieler unterschiedlicher Medikamente möglich. LC mit Säulenschaltung erlaubt eine Automatisierung. Dabei wird Blutserum oder -plasma mit oder ohne vorherige Proteinfällung auf eine Vorsäule aufgetragen. Nach Auswaschen von störenden Matrixbestandteilen werden die Medikamente auf einer nachgeschalteten analytischen Säule getrennt und über Ultraviolettspektroskopie (UV) oder Massenspektrometrie (MS) detektiert. Ziel dieser Arbeit war es, LC-Methoden zu entwickeln, die die Messung möglichst vieler Antipsychotika und Antidepressiva erlaubt und die für die TDM-Routine geeignet ist. Eine mit C8-modifiziertem Kieselgel gefüllte Säule (20 µm 10x4.0 mm I.D.) erwies sich in Vorexperimenten als optimal geeignet bezüglich Extraktionsverhalten, Regenerierbarkeit und Stabilität. Mit einer ersten HPLC-UV-Methode mit Säulenschaltung konnten 20 verschiedene Psychopharmaka einschließlich ihrer Metabolite, also insgesamt 30 verschiedene Substanzen quantitativ erfasst werden. Die Analysenzeit betrug 30 Minuten. Die Vorsäule erlaubte 150 Injektionen, die analytische Säule konnte mit mehr als 300 Plasmainjektionen belastet werden. Abhängig vom Analyten, musste allerdings das Injektionsvolumen, die Flussrate oder die Detektionswellenlänge verändert werden. Die Methode war daher für eine Routineanwendung nur eingeschränkt geeignet. Mit einer zweiten HPLC-UV-Methode konnten 43 verschiedene Antipsychotika und Antidepressiva inklusive Metaboliten nachgewiesen werden. Nach Vorreinigung über C8-Material (10 µm, 10x4 mm I.D.) erfolgte die Trennung auf Hypersil ODS (5 µm Partikelgröße) in der analytischen Säule (250x4.6 mm I.D.) mit 37.5% Acetonitril im analytischen Eluenten. Die optimale Flussrate war 1.5 ml/min und die Detektionswellenlänge 254 nm. In einer Einzelprobe, konnten mit dieser Methode 7 bis 8 unterschiedliche Substanzen gemessen werden. Für die Antipsychotika Clozapin, Olanzapin, Perazin, Quetiapin und Ziprasidon wurde die Methode validiert. Der Variationskoeffizient (VK%) für die Impräzision lag zwischen 0.2 und 6.1%. Im erforderlichen Messbereich war die Methode linear (Korrelationskoeffizienten, R2 zwischen 0.9765 und 0.9816). Die absolute und analytische Wiederfindung lagen zwischen 98 und 118 %. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Für Olanzapin betrug sie 5 ng/ml. Die Methode wurde an Patienten für das TDM getestet. Sie erwies sich für das TDM als sehr gut geeignet. Nach retrospektiver Auswertung von Patientendaten konnte erstmalig ein möglicher therapeutischer Bereich für Quetiapin (40-170 ng/ml) und Ziprasidon (40-130 ng/ml) formuliert werden. Mit einem Massenspektrometer als Detektor war die Messung von acht Neuroleptika und ihren Metaboliten möglich. 12 Substanzen konnten in einem Lauf bestimmt werden: Amisulprid, Clozapin, N-Desmethylclozapin, Clozapin-N-oxid, Haloperidol, Risperidon, 9-Hydroxyrisperidon, Olanzapin, Perazin, N-Desmethylperazin, Quetiapin und Ziprasidon. Nach Vorreinigung mit C8-Material (20 µm 10x4.0 mm I.D.) erfolgte die Trennung auf Synergi MAX-RP C12 (4 µm 150 x 4.6 mm). Die Validierung der HPLC-MS-Methode belegten einen linearen Zusammenhang zwischen Konzentration und Detektorsignal (R2= 0,9974 bis 0.9999). Die Impräzision lag zwischen 0.84 bis 9.78%. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Es gab keine Hinweise auf das Auftreten von Ion Suppression durch Matrixbestandteile. Die absolute und analytische Wiederfindung lag zwischen 89 und 107 %. Es zeigte sich, dass die HPLC-MS-Methode ohne Modifikation erweitert werden kann und anscheinend mehr als 30 verschiedene Psychopharmaka erfasst werden können. Mit den entwickelten flüssigchromatographischen Methoden stehen neue Verfahren für das TDM von Antipsychotika und Antidepressiva zur Verfügung, die es erlauben, mit einer Methode verschiedene Psychopharmaka und ihre aktiven Metabolite zu messen. Damit kann die Behandlung psychiatrischer Patienten insbesondere mit Antipsychotika verbessert werden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative branch determination in polyolefins by solid- and melt-state 13C NMR has been investigated. Both methods were optimised toward sensitivity per unit time. While solid-state NMR was shown to give quick albeit only qualitative results, melt-state NMR allowed highly time efficient accurate branch quantification. Comparison of spectra obtained using spectrometers operating at 300, 500 and 700 MHz 1H Larmor frequency, with 4 and 7~mm MAS probeheads, showed that the best sensitivity was achieved at 500 MHz using a 7 mm 13C-1H optimised high temperature probehead. For materials available in large quantities, static melt-state NMR, using large diameter detection coils and high coil filling at 300 MHz, was shown to produce comparable results to melt-state MAS measurements in less time. While the use of J-coupling mediated polarisation transfer techniques was shown to be possible, direct polarisation via single-pulse excitation proved to be more suitable for branch quantification in the melt-state. Artificial line broadening, introduced by FID truncation, was able to be reduced by the use of π pulse-train heteronuclear dipolar decoupling. This decoupling method, when combined with an extended duty-cycle, allowed for significant improvement in resolution. Standard setup, processing and analysis techniques were developed to minimise systematic errors contributing to the measured branch contents. The final optimised melt-state MAS NMR method was shown to allow time efficient quantification of comonomer content and distribution in both polyethylene- and polypropylene-co-α-olefins. The sensitivity of the technique was demonstrated by quantifying branch concentrations of 8 branches per 100,000 CH2 for an industrial ‘linear’ polyethylene in only 13 hours. Even lower degrees of 3–8 long-chain branches per 100,000 carbons were able to be estimated in just 24 hours for a series of γ-irradiated polypropylene homopolymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In der Vergangenheit wurde die Wichtigkeit von Iodverbindungen im Bezug auf die Aerosolbildung in Küstennähe wiederholt bestätigt. Durch Photolyse von flüchtigen iodorganischen Verbindungen (VOIs) können in der Atmosphäre Iodatome gebildet werden. Diese hochreaktiven Radikale wiederum können mit Ozon und/oder OH-Radikalen reagieren. Es werden so unter anderem schwerflüchtige Iodoxide gebildet, die in die Partikelphase übergehen können. Um ein Verständnis für die Mechanismen und chemischen Reaktionen zu bekommen, die zur Bildung von iodhaltigen Aerosolpartikeln führen, müssen auch Vorläufersubstanzen qualitativ und quanitativ bestimmt werden. Ob diese Reaktionen und chemischen Verbindungen auch über dem offenen Ozean einen Beitrag zu Aerosolbildung und somit zur Beeinflussung des weltweitem Klimas leisten, soll in dem EU-Projekt MAP geklärt werden, diese Arbeit ist Teil dieses Projekts. Im Rahmen dieser Arbeit wurde eine Methode entwickelt, die es zum einen möglich macht, anorganisches Iod in Meerwasser zu bestimmen. Zum anderen sollte eine Methode entwickelt werden, um elementares Iod in der maritimen Atmosphäre zu bestimmen. Es wurde eine Derivatisierungsmethode entwickelt, die es möglich macht elementares Iod in Anwesenheit von Stärke, a-Cyclodextrin oder RAMEA zu derivatisieren. Die Derivatisierung erfolgt zu 4-Iodo-N,N-Dimethylanilin. Durch Extraktion wird der Analyt in die organische Phase überführt. Die Quantifizierung erfolgt anschließend über die Analyse mit GC/MS und externer Kalibrierung. Die absolute Nachweisgrenze für Iod in Wasser beträgt 0,57nmol, für Iodid 0,014nmol und für Iodat 0,115nmol. Die absoluten Nachweisgrenzen für Iod in Anwesenheit eines Absorptionsmittel betragen für Stärke 0,24nmol, für a-Cyclodextrin 0,9nmol und für RAMEA 0,35nmol. Die Analysenmethoden wurden zunächst im Labor entwickelt und anschließend zur Analyse von Realproben verwendet. An verschiedenen Orten wurden Meerwasserproben (auf der Celtic Explorer und in der Nähe der Mace Head Messstation) genommen und deren Iod-, Iodid- und Iodatgehalt bestimmt. Keine der Proben enthielt elementares Iod. Iodid konnte in allen Proben detektiert werden. In Proben, die auf dem offenen Ozean an Bord der Celtic Explorer genommen wurden variierte die Menge zwischen 12µg/L und 90µg/L. Auffällig war hierbei, dass die Proben, die in Küstennähe genommen wurden höhere Iodidkonzentrationen aufwiesen. Ein Einfluss der Küste und der dort vorhandenen Makroalgen ist sehr wahrscheinlich. Meerwasserproben, die in der Nähe der MHARS genommen wurden wiesen höhere Konzentrationen und einen größeren dynamischen Bereich der Iodidkonzentrationen auf. Die Konzentrationen variierten von 29µg/L bis 630 µg/L. Der Iodatgehalt der Meerwasserproben wurde ebenfalls bestimmt. 1µg/L bis 90µg/L Iodat konnte in den Proben vom offenen Ozean detektiert werden. Die Küstenproben wiesen mit 150µg/L bis 230µg/L deutlich höhere Iodatkonzentrationen auf. Es konnte kein Zusammenhang zwischen der Tageszeit und den Iodid- oder Iodatkonzentrationen gefunden werden. Es konnte ebenso kein Zusammenhang zwischen der Fluoreszenz des Meerwassers und den Iodid- oder Iodatkonzentrationen gefunden werden. Auf der Celtic Explorer, wie auch in Mace Head wurden außerdem beschichtete Denuder zur Anreicherung von elementarem Iod aus Luft eingesetzt. Die Denuder, die auf dem Schiff verwendet wurden waren mit Stärke bzw. mit a-CD beschichtet. Die mit Stärke beschichteten Denuder geben so einen Überblick über die Iodkonzentration in Luft über einen längeren Zeitraum (ca. 2-3h), während die mit Cyclodextrin beschichteten Denuder die Iodkonzentration in der letzten halben Stunde der Probennahme widerspiegeln. In fast allen Denudern, die mit Stärke beschichtet waren, konnte mehr Iod nachgewiesen werden, als in denen, die mit a-CD beschichtet waren. Im Allgemeinen konnten in den Proben höhere Iodkonzentrationen gefunden werden, die nachts genommen wurden. Der Grund hierfür liegt in der sehr hohen Photolyserate des elementaren Iods während des Tages. Ein Zusammenhang zwischen der Konzentration von VOIs und dem Iodgehalt konnte nicht gefunden werden. Anhand der genommen Denuderproben von Mace Head konnte festgestellt werden, dass die Iodkonzentration in Denudern, deren Probenahme während Ebbe beendet wurde hoch deutlich höher sind, als die in anderen Denudern. Das lässt sich dadurch erklären, dass Makroalgen während Ebbe in direktem Kontakt zur Luft sind und somit mehr Iod in der Luft zu finden ist. Eine wichtige Frage, die im Zusammenhang mit der Iodchemie in maritimer Umgebung steht konnte im Rahmen dieser Arbeit geklärt werden. In der maritimen Grenzschicht über dem Nordatlantik konnte elementares Iod detektiert werden, d.h. es deutet sich an, dass Iod auch auf dem offenen Ozean einen Beitrag zur Partikelbildung liefern kann und es sich nicht ausschließlich um einen Küsteneffekt handelt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herz-Kreislauf-Erkrankungen zählen weltweit zu den Hauptursachen, die zu frühzeitigem Tod führen. Pathophysiologisch liegt eine Gefäßwandverdickung durch Ablagerung arteriosklerotischer Plaques (Arteriosklerose) vor. Die molekulare Bildgebung mit den nuklearmedizinischen Verfahren SPECT und PET zielt darauf ab, minderperfundierte Myokardareale zu visualisieren, um den Krankheitsverlauf durch frühzeitige Therapie abschwächen zu können. Routinemäßig eingesetzt werden die SPECT-Perfusionstracer [99mTc]Sestamibi und [99mTc]Tetrofosmin. Zum Goldstandard für die Quantifizierung der Myokardperfusion werden allerdings die PET-Tracer [13N]NH3 und [15O]H2O, da eine absolute Bestimmung des Blutflusses in mL/min/g sowohl in der Ruhe als auch bei Belastung möglich ist. 2007 wurde [18F]Flurpiridaz als neuer Myokardtracer vorgestellt, dessen Bindung an den MC I sowohl in Ratten, Hasen, Primaten als auch in ersten klinischen Humanstudien eine selektive Myokardaufnahme zeigte. Um eine Verfügbarkeit des Radionuklids über einen Radionuklidgenerator gewährleisten zu können, sollten makrozyklische 68Ga-Myokard-Perfusionstracer auf Pyridaben-Basis synthetisiert und evaluiert werden. Die neue Tracer-Klasse setzte sich aus dem makrozyklischen Chelator, einem Linker und dem Insektizid Pyridaben als Targeting-Vektor zusammen. Struktur-Affinitätsbeziehungen konnten auf Grund von Variation des Linkers (Länge und Polarität), der Komplexladung (neutral und einfach positiv geladen), des Chelators (DOTA, NODAGA, DO2A) sowie durch einen Multivalenzansatz (Monomer und Dimer) aufgestellt werden. Insgesamt wurden 16 neue Verbindungen synthetisiert. Ihre 68Ga-Markierung wurde hinsichtlich pH-Wert, Temperatur, Vorläufermenge und Reaktionszeit optimiert. Die DOTA/NODAGA-Pyridaben-Derivate ließen sich mit niedrigen Substanzmengen (6 - 25 nmol) in 0,1 M HEPES-Puffer (pH 3,4) bei 95°C innerhalb 15 min mit Ausbeuten > 95 % markieren. Für die DO2A-basierenden Verbindungen bedurfte es einer mikrowellengestützen Markierung (300 W, 1 min, 150°C), um vergleichbare Ausbeuten zu erzielen. Die in vitro-Stabilitätstests aller Verbindungen erfolgten in EtOH, NaCl und humanem Serum. Es konnten keine Instabilitäten innerhalb 80 min bei 37°C festgestellt werden. Unter Verwendung der „shake flask“-Methode wurden die Lipophilien (log D = -1,90 – 1,91) anhand des Verteilungs-quotienten in Octanol/PBS-Puffer ermittelt. Die kalten Referenzsubstanzen wurden mit GaCl3 hergestellt und zur Bestimmung der IC50-Werte (34,1 µM – 1 µM) in vitro auf ihre Affinität zum MC I getestet. In vivo-Evaluierungen erfolgten mit den zwei potentesten Verbindungen [68Ga]VN160.MZ und [68Ga]VN167.MZ durch µ-PET-Aufnahmen (n=3) in gesunden Ratten über 60 min. Um die Organverteilung ermitteln zu können, wurden ex vivo-Biodistributionsstudien (n=3) vorgenommen. Sowohl die µ-PET-Untersuchungen als auch die Biodistributionsstudien zeigten, dass es bei [68Ga]VN167.MZ zwar zu einer Herzaufnahme kam, die jedoch eher perfusionsabhängig ist. Eine Retention des Tracers im Myokard konnte in geringem Umfang festgestellt werden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eisbohrkerne stellen wertvolle Klimaarchive dar, da sie atmosphärisches Aerosol konservieren. Die Analyse chemischer Verbindungen als Bestandteil atmosphärischer Aerosole in Eisbohrkernen liefert wichtige Informationen über Umweltbedingungen und Klima der Vergangenheit. Zur Untersuchung der α-Dicarbonyle Glyoxal und Methylglyoxal in Eis- und Schneeproben wurde eine neue, sensitive Methode entwickelt, die die Stir Bar Sorptive Extraction (SBSE) mit der Hochleistungsflüssigchromatographie-Massenspektrometrie (HPLC-MS) kombiniert. Zur Analyse von Dicarbonsäuren in Eisbohrkernen wurde eine weitere Methode entwickelt, bei der die Festphasenextraktion mit starkem Anionenaustauscher zum Einsatz kommt. Die Methode erlaubt die Quantifizierung aliphatischer Dicarbonsäuren (≥ C6), einschließlich Pinsäure, sowie aromatischer Carbonsäuren (wie Phthalsäure und Vanillinsäure), wodurch die Bestimmung wichtiger Markerverbindungen für biogene und anthropogene Quellen ermöglicht wurde. Mit Hilfe der entwickelten Methoden wurde ein Eisbohrkern aus den Schweizer Alpen analysiert. Die ermittelten Konzentrationsverläufe der Analyten umfassen die Zeitspanne von 1942 bis 1993. Mittels einer Korrelations- und Hauptkomponentenanalyse konnte gezeigt werden, dass die organischen Verbindungen im Eis hauptsächlich durch Waldbrände und durch vom Menschen verursachte Schadstoffemissionen beeinflusst werden. Im Gegensatz dazu sind die Konzentrationsverläufe einiger Analyten auf den Mineralstaubtransport auf den Gletscher zurückzuführen. Zusätzlich wurde ein Screening der Eisbohrkernproben mittels ultrahochauflösender Massenspektrometrie durchgeführt. Zum ersten Mal wurden in diesem Rahmen auch Organosulfate und Nitrooxyorganosulfate in einem Eisbohrkern identifiziert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderne ESI-LC-MS/MS-Techniken erlauben in Verbindung mit Bottom-up-Ansätzen eine qualitative und quantitative Charakterisierung mehrerer tausend Proteine in einem einzigen Experiment. Für die labelfreie Proteinquantifizierung eignen sich besonders datenunabhängige Akquisitionsmethoden wie MSE und die IMS-Varianten HDMSE und UDMSE. Durch ihre hohe Komplexität stellen die so erfassten Daten besondere Anforderungen an die Analysesoftware. Eine quantitative Analyse der MSE/HDMSE/UDMSE-Daten blieb bislang wenigen kommerziellen Lösungen vorbehalten. rn| In der vorliegenden Arbeit wurden eine Strategie und eine Reihe neuer Methoden zur messungsübergreifenden, quantitativen Analyse labelfreier MSE/HDMSE/UDMSE-Daten entwickelt und als Software ISOQuant implementiert. Für die ersten Schritte der Datenanalyse (Featuredetektion, Peptid- und Proteinidentifikation) wird die kommerzielle Software PLGS verwendet. Anschließend werden die unabhängigen PLGS-Ergebnisse aller Messungen eines Experiments in einer relationalen Datenbank zusammengeführt und mit Hilfe der dedizierten Algorithmen (Retentionszeitalignment, Feature-Clustering, multidimensionale Normalisierung der Intensitäten, mehrstufige Datenfilterung, Proteininferenz, Umverteilung der Intensitäten geteilter Peptide, Proteinquantifizierung) überarbeitet. Durch diese Nachbearbeitung wird die Reproduzierbarkeit der qualitativen und quantitativen Ergebnisse signifikant gesteigert.rn| Um die Performance der quantitativen Datenanalyse zu evaluieren und mit anderen Lösungen zu vergleichen, wurde ein Satz von exakt definierten Hybridproteom-Proben entwickelt. Die Proben wurden mit den Methoden MSE und UDMSE erfasst, mit Progenesis QIP, synapter und ISOQuant analysiert und verglichen. Im Gegensatz zu synapter und Progenesis QIP konnte ISOQuant sowohl eine hohe Reproduzierbarkeit der Proteinidentifikation als auch eine hohe Präzision und Richtigkeit der Proteinquantifizierung erreichen.rn| Schlussfolgernd ermöglichen die vorgestellten Algorithmen und der Analyseworkflow zuverlässige und reproduzierbare quantitative Datenanalysen. Mit der Software ISOQuant wurde ein einfaches und effizientes Werkzeug für routinemäßige Hochdurchsatzanalysen labelfreier MSE/HDMSE/UDMSE-Daten entwickelt. Mit den Hybridproteom-Proben und den Bewertungsmetriken wurde ein umfassendes System zur Evaluierung quantitativer Akquisitions- und Datenanalysesysteme vorgestellt.