5 resultados para 2-perfect Extended M-cycle Systems
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
Quantitative branch determination in polyolefins by solid- and melt-state 13C NMR has been investigated. Both methods were optimised toward sensitivity per unit time. While solid-state NMR was shown to give quick albeit only qualitative results, melt-state NMR allowed highly time efficient accurate branch quantification. Comparison of spectra obtained using spectrometers operating at 300, 500 and 700 MHz 1H Larmor frequency, with 4 and 7~mm MAS probeheads, showed that the best sensitivity was achieved at 500 MHz using a 7 mm 13C-1H optimised high temperature probehead. For materials available in large quantities, static melt-state NMR, using large diameter detection coils and high coil filling at 300 MHz, was shown to produce comparable results to melt-state MAS measurements in less time. While the use of J-coupling mediated polarisation transfer techniques was shown to be possible, direct polarisation via single-pulse excitation proved to be more suitable for branch quantification in the melt-state. Artificial line broadening, introduced by FID truncation, was able to be reduced by the use of π pulse-train heteronuclear dipolar decoupling. This decoupling method, when combined with an extended duty-cycle, allowed for significant improvement in resolution. Standard setup, processing and analysis techniques were developed to minimise systematic errors contributing to the measured branch contents. The final optimised melt-state MAS NMR method was shown to allow time efficient quantification of comonomer content and distribution in both polyethylene- and polypropylene-co-α-olefins. The sensitivity of the technique was demonstrated by quantifying branch concentrations of 8 branches per 100,000 CH2 for an industrial ‘linear’ polyethylene in only 13 hours. Even lower degrees of 3–8 long-chain branches per 100,000 carbons were able to be estimated in just 24 hours for a series of γ-irradiated polypropylene homopolymers.
Resumo:
Die beiden in dieser Arbeit betrachteten Systeme, wässrige Lösungen von Ionen und ionische Flüssigkeiten, zeigen vielfältige Eigenschaften und Anwendungsmöglichkeiten, im Gegensatz zu anderen Systemen. Man findet sie beinahe überall im normalen Leben (Wasser), oder ihre Bedeutung wächst (ioinische Flüssigkeiten). Der elektronische Anteil und der atomare Anteil wurden getrennt voneinander untersucht und im Zusammenhang analysiert. Mittels dieser Methode konnten die in dem jeweiligen System auftretenden Mechanismen genauer untersucht werden. Diese Methode wird "Multiscale Modeling" genannt, dabei werden die Untereinheiten eines Systems genauer betrachtet, wie in diesem Fall die elektronischen and atomaren Teilsystem. Die Ergebnisse, die aus den jeweiligen Betrachtungen hervorgehen, zeigen, dass, im Falle von hydratisierten Ionen die Wasser-Wasser Wechselwirkungen wesentlich stärker sind als die elektrostatischen Wechselwirkung zwischen Wasser und dem Ion. Anhand der Ergebnisse ergibt sich, dass normale nicht-polarisierbare Modelle ausreichen, um Ionen-Wasser Lösungen zu beschreiben. Im Falle der ionischen Flüssigkeiten betrachten wir die elektronische Ebene mittels sehr genauer post-Hartree-Fock Methoden und DFT, deren Ergebnisse dann mit denen auf molekularer Ebene (mithilfe von CPMD/klassischer MD) in Beziehung gesetzt werden. Die bisherigen Ergebnisse zeigen, dass die Wasserstoff-Brückenbindungen im Fall der ionischen Flüssigkeiten nicht vernachässigt werden können. Weiterhin hat diese Studie herausgefunden, dass die klassischen Kraftfelder die Elektrostatik (Dipol- und Quadrupolmomente) nicht genau genug beschreibt. Die Kombination des mikroskopischen Mechanismus und der molekularen Eigenschaften ist besonders sinnvoll um verschiedene Anhaltspunkte von Simualtionen (z.B. mit klassische Molekular-Dynamik) oder Experimenten zu liefern oder solche zu erklären.
Resumo:
In den westlichen Ländern nimmt die Zahl der Schlaganfall-Patienten stetig zu und zählt mittlerweilernzu einer der häufigsten Todesursachen. Derzeit ist die Rekanalisationstherapie mit demrnFibrinolytikum rt-PA die einzig zugelassene Therapie. Die Rekanalisationsrate ist oftmals inkomplettrnund aufgrund von möglichen Blutungskomplikationen die Therapie nicht bei allen Patientenrnmöglich. Daher ist es wichtig, Alternativtherapieansätze (z.B. Ultraschallthrombolyse) zurnentwickeln. Blutgerinnsel können mit Hilfe von Ultraschall in Schwingung gebracht und sornlysiert oder die Wirkung von rt-PA verstärkt werden. Die vorliegende Arbeit hatte die Evaluationrnvon Bioeffekten von 60 kHz Ultraschall an gesundem und ischämischem Hirngewebe zum Ziel.rnNeben tierexperimentellen Methoden kamen auch molekular-biologische Techniken zur Anwendung.rnDie erste Studie beschäftigte sich mit der Wirkung von 60 kHz (Intensität: 0,2 W/cm2 undrnDuty Cycle 50%) auf ischämisches Hirngewebe (permanent ischämisch und nach Reperfusion).rnLediglich nach Reperfusion und Ultraschallbehandlung war das Läsionsvolumen signifikantrnerhöht, so dass von einer besonderen Vulnerabilität des Hirngewebes nach Reperfusionrnauszugehen ist (Penumbraschädigung). In der neurologischen Beurteilung der Tiere zeigte sichrnbei allen Tieren mit permanenter Okklusion und etwa einem Drittel der Tiere nach Reperfusionrnund Ultraschallbehandlung eine Hörminderung. In der anschließenden Studie wurde diernUltraschallintensität erniedrigt und der Duty Cycle variiert. In einer publizierten in vitro Studiernkonnte die zunehmende Lyserate mit steigendem Duty Cycle nachgewiesen werden. DiernAuswertung ergab eine Abhängigkeit des Läsionsvolumens von der Länge des Duty Cycles. Derrndritte Teil der Arbeit befasst sich mit der Wirkung von Ultraschall auf die Genexpression. Hierzurnwurden gesunde Ratten mit Ultraschall verschiedener Frequenzen (60 kHz, 488 kHz und 3 MHz)rntranskraniell behandelt und 4 h bzw. 24 h nach der Behandlung getötet. Proben von ischämischenrnTieren dienten als positive Kontrollen. Aufgrund von Literaturrecherchen wurden mehrerernKandidatengene ermittelt. Die Messung der Ischämieproben ergab eine weitgehende Übereinstimmungrnmit der Literatur. Die Messungen an den mit 60 kHz behandelten Proben ergabenrnkaum Anzeichen für eine differenzielle Genregulation. Die Frequenz von 488 kHz zeigte diernmeisten Regulationen, gefolgt von der Behandlung mit 3 MHz. Dieses Ergebnis lässt vermuten,rndass es sich bei den detektierten Veränderungen um protektive Mechanismen handelt, da diesernFrequenzen bislang im Tierversuch als nebenwirkungsarm beschrieben wurden. Die Auswertungrnvon 60 kHz-Proben mit Affymetrix Arrays ergab lediglich einige wenige differentiell regulierternGene. Die Array-Experimente konnten nicht durch qPCR-Messungen bestätigt werden.
Resumo:
In this work the growth and the magnetic properties of the transition metals molybdenum, niobium, and iron and of the highly-magnetostrictive C15 Laves phases of the RFe2 compounds (R: Rare earth metals: here Tb, Dy, and Tb{0.3}Dy{0.7} deposited on alpha-Al2O3 (sapphire) substrates are analyzed. Next to (11-20) (a-plane) oriented sapphire substrates mainly (10-10) (m-plane) oriented substrates were used. These show a pronounced facetting after high temperature annealing in air. Atomic force microscopy (AFM) measurements reveal a dependence of the height, width, and angle of the facets with the annealing temperature. The observed deviations of the facet angles with respect to the theoretical values of the sapphire (10-1-2) and (10-11) surfaces are explained by cross section high resolution transmission electron microscopy (HR-TEM) measurements. These show the plain formation of the (10-11) surface while the second, energy reduced (10-1-2) facet has a curved shape given by atomic steps of (10-1-2) layers and is formed completely solely at the facet ridges and valleys. Thin films of Mo and Nb, respectively, deposited by means of molecular beam epitaxy (MBE) reveal a non-twinned, (211)-oriented epitaxial growth as well on non-faceted as on faceted sapphire m-plane, as was shown by X-Ray and TEM evaluations. In the case of faceted sapphire the two bcc crystals overgrow the facets homogeneously. Here, the bcc (111) surface is nearly parallel to the sapphire (10-11) facet and the Mo/Nb (100) surface is nearly parallel to the sapphire (10-1-2) surface. (211)-oriented Nb templates on sapphire m-plane can be used for the non-twinned, (211)-oriented growth of RFe2 films by means of MBE. Again, the quality of the RFe2 films grown on faceted sapphire is almost equal to films on the non-faceted substrate. For comparison thin RFe2 films of the established (110) and (111) orientation were prepared. Magnetic and magnetoelastic measurements performed in a self designed setup reveal a high quality of the samples. No difference between samples with undulated and flat morphology can be observed. In addition to the preparation of covering, undulating thin films on faceted sapphire m-plane nanoscopic structures of Nb and Fe were prepared by shallow incidence MBE. The formation of the nanostructures can be explained by a shadowing of the atomic beam due to the facets in addition to de-wetting effects of the metals on the heated sapphire surface. Accordingly, the nanostructures form at the facet ridges and overgrow them. The morphology of the structures can be varied by deposition conditions as was shown for Fe. The shape of the structures vary from pearl-necklet strung spherical nanodots with a diameter of a few 10 nm to oval nanodots of a few 100 nm length to continuous nanowires. Magnetization measurements reveal uniaxial magnetic anisotropy with the easy axis of magnetization parallel to the facet ridges. The shape of the hysteresis is depending on the morphology of the structures. The magnetization reversal processes of the spherical and oval nanodots were simulated by micromagnetic modelling and can be explained by the formation of magnetic vortices.
Resumo:
Die kollineare Laserspektroskopie hat sich in den vergangenen drei Jahrzehnten zur Bestimmung der Kernladungsradien mittelschwerer und schwerer kurzlebiger Atomkerne in ausgezeichneter Weise bewährt. Auf die Isotope sehr leichter Elemente konnte sie allerdings erst kürzlich erweitert werden. Dieser Bereich der Nuklidkarte ist von besonderem Interesse, denn die ersten ab-initio Modelle der Kernphysik, die den Aufbau eines Atomkerns basierend auf individuellen Nukleonen und realistischenWechselwirkungspotentialen beschreiben, sind gegenwärtig nur für die leichtesten Elemente anwendbar. Außerdem existiertrnin dieser Region eine besonders exotische Form von Atomkernen, die sogenanntenrnHalokerne. Die Isotopenkette der Berylliumisotope zeichnet sich durch das Auftreten des Ein-Neutronen Halokerns 11Be und des Zwei- oder Vier-Neutronen-Halos 14Be aus. Dem Isotop 12Be kommt durch seine Position zwischen diesen beiden Exoten und den im Schalenmodell erwarteten magischen Schalenabschluss N = 8 eine besondere Bedeutung zu.rnIm Rahmen dieser Arbeit wurden mehrere frequenzstabilisierte Lasersysteme für die kollineare Laserspektroskopie aufgebaut. An TRIGA-SPEC stehen nun unter anderem ein frequenzverdoppeltes Diodenlasersystem mit Trapezverstärker und frequenzkammstabilisierter Titan-Saphirlaser mit Frequenzverdopplungsstufe für die Spektroskopie an refraktären Elementen oberhalb von Molybdän zur Verfügung, die für erste Testexperimente eingesetzt wurden. Außerdem wurde die effiziente Frequenzvervierfachung eines Titan-Saphirlasers demonstriert. An ISOLDE/CERN wurde ein frequenzkammstabilisierter und ein jodstabilisierter Farbstofflaser installiert und für die Laserspektroskopie an 9,10,11,12Be eingesetzt. Durch das verbesserte Lasersystem und den Einsatz eines verzögerten Koinzidenznachweises für Photonen und Ionen gelang es die Empfindlichkeitrnder Berylliumspektroskopie um mehr als zwei Größenordnungen zu steigern und damit die früheren Messungen an 7−11Be erstmals auf das Isotop 12Be auszuweiten. Außerdem wurde die Genauigkeit der absoluten Übergangsfrequenzen und der Isotopieverschiebungen der Isotope 9,10,11Be signifikant verbessert.rnDurch den Vergleich mit Ergebnissen des Fermionic Molecular Dynamics Modells kann der Trend der Ladungsradien der leichteren Isotope durch die ausgeprägte Clusterstruktur der Berylliumkerne erklärt werden. Für 12Be wird ersichtlich, dass der Grundzustand durch eine (sd)2 Konfiguration statt der vom Schalenmodell erwarteten p2 Konfiguration dominiert wird. Dies ist ein klares Indiz für das bereits zuvor beobachtete Verschwinden des N = 8 Schalenabschlusses bei 12Be.