9 resultados para 10-HZ REPETITION RATE

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent developments in the theory of plasma-based collisionally excited x-ray lasers (XRL) have shown an optimization potential based on the dependence of the absorption region of the pumping laser on its angle of incidence on the plasma. For the experimental proof of this idea, a number of diagnostic schemes were developed, tested, qualified and applied. A high-resolution imaging system, yielding the keV emission profile perpendicular to the target surface, provided positions of the hottest plasma regions, interesting for the benchmarking of plasma simulation codes. The implementation of a highly efficient spectrometer for the plasma emission made it possible to gain information about the abundance of the ionization states necessary for the laser action in the plasma. The intensity distribution and deflection angle of the pump laser beam could be imaged for single XRL shots, giving access to its refraction process within the plasma. During a European collaboration campaign at the Lund Laser Center, Sweden, the optimization of the pumping laser incidence angle resulted in a reduction of the required pumping energy for a Ni-like Mo XRL, which enabled the operation at a repetition rate of 10 Hz. Using the experiences gained there, the XRL performance at the PHELIX facility, GSI Darmstadt with respect to achievable repetition rate and at wavelengths below 20 nm was significantly improved, and also important information for the development towards multi-100 eV plasma XRLs was acquired. Due to the setup improvements achieved during the work for this thesis, the PHELIX XRL system now has reached a degree of reproducibility and versatility which is sufficient for demanding applications like the XRL spectroscopy of heavy ions. In addition, a European research campaign, aiming towards plasma XRLs approaching the water-window (wavelengths below 5 nm) was initiated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Resonanzionisations-Massenspektrometrie (RIMS) ist sowohl für spektroskopische Untersuchungen seltener Isotope als auch für den Ultraspurennachweis langlebiger radioaktiver Elemente einsetzbar. Durch die mehrstufige resonante Anregung atomarer Energieniveaus mit anschließender Ionisation mit Laserlicht wird eine sehr hohe Elementselektivität und Ionisationseffizienz erreicht. Der nachfolgende massenselektive Ionennachweis liefert eine gute Isotopenselektivität zusammen mit einer effektiven Untergrundunterdrückung. Ein wichtiger Bestandteil der RIMS-Apparatur ist ein zuverlässig arbeitendes, leistungsstarkes Lasersystem für die Resonanzionisation. Im Rahmen dieser Arbeit wurde ein von einem hochrepetierenden Nd:YAG-Laser gepumptes, aus drei Titan-Saphir-Lasern bestehendes System fertig aufgebaut und in den Routinebetrieb überführt. Die Titan-Saphir-Laser liefern im Durchstimmbereich von 730 - 880 nm eine mittlere Leistung von bis zu 3 W pro Laser bei einer Linienbreite von 2 - 3 GHz. Sie lassen sich computergesteuert in ihren Wellenlängen durchstimmen. Die mittels Resonanzionisation erzeugten Ionen werden dann in einem Flugzeit-Massenspektrometer entsprechend ihrer Masse aufgetrennt und mit einem Kanalplattendetektor nachgewiesen.Als Voraussetzung für die isotopenselektive Ultraspurenanalyse von Plutonium wurden mit diesem Lasersystem die Isotopieverschiebungen eines effizienten, dreistufigen Anregungsschema für Plutonium bestimmt. Die Laserleistungen reichen zur vielfachen Sättigung der ersten beiden Anregungsschritte und zur zweifachen Sättigung des dritten Anregungsschritts aus.Außerdem wurden die Ionisationsenergien von Pu-239 und Pu-244 zur Untersuchung ihrer Isotopenabhängigkeit bestimmt. Die beiden Ionisationsenergien sind im Rahmen der erreichten Genauigkeit bei einem Meßwert von IP239-IP244 = 0,24(82) cm^-1 gleich.Die Nachweiseffizienz der RIMS-Apparatur für Plutonium wurde in Effizienzmessungen zu 10^-5 bestimmt. Durch die gute Untergrundunterdrückung ergab sich daraus eine Nachweisgrenze von 10^6 Atomen bei der Messung eines Plutoniumisotops. Die Bestimmung der Isotopenverhältnisse von Proben mit einer zertifizierten Isotopenzusammensetzung lieferte eine gute Übereinstimmung der Meßwerte mit den angegebenen Zusammensetzungen.Die RIMS-Apparatur wurde zur Bestimmung des Gehalts und der Isotopenzusammensetzung von Plutonium in Meerwasser- und Staubproben eingesetzt.Auf Grund der Isotopenzusammensetzung konnte gezeigt werden, daß das Plutonium bei den meisten Proben aus dem Fallout von oberirdischen Kernwaffentests stammte. Des weiteren wurde Plutonium in Urinproben bestimmt. Die Nachweisgrenzen lagen bei diesen Umweltproben bei 10^6 bis 10^7 Atomen Plutonium und damit um zwei Größenordnungen niedriger als die Nachweisgrenze für Pu-239 bei der alpha-Spektroskopie, der Standardmethode für den Plutoniumnachweis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die resonante Laserionisation hat sich als ein universales Verfahren für eine Vielzahl von Anwendungen etabliert, die eine selektive Ionisation bei hoher Effizienz erfordern. Hierzu wurden zwei Lasersysteme mit unterschiedlichen Zielsetzungen und Schwerpunkten entwickelt und in dieser Arbeit angewendet. Im ersten Teil der Arbeit wird die Entwicklung der hochauflösenden Resonanzionisations-Massenspektrometrie zum Ultraspurennachweis von 41Ca vorgestellt. Hierzu wurden drei kontinuierliche Diodenlaser mit einem Quadrupolmassenspektrometer kombiniert. Bei einer Nachweiseffizienz von 1 × 10^−5 konnte eine Nachweisgrenze von 2 × 10^-13 41Ca/totCa erreicht werden. Das in den Routinebetrieb überführte Meßverfahren ermöglichte die Teilnahme an einem interdisziplinären Netzwerk zur Osteoporose-Forschung. In Vergleichsmessungen der Resonanzionisations-Massenspektrometrie mit allen derzeit existierenden Meßverfahren zum 41Ca-Ultraspurennachweis konnte eine sehr gute Übereinstimmung erzielt werden. Der zweite Teil der Arbeit beinhaltet die Adaption eines durchstimmbaren, hochrepetierenden Titan:Saphir-Lasersystem für den Einsatz an Laserionenquellen zur selektiven Erzeugung radioaktiver Ionenstrahlen. Das entwickelte Lasersystem ermöglicht eine effiziente, resonante Anregung des Großteils der Elemente im Periodensystem. Hierzu wurde eine kombinierte Frequenzverdopplungs- und Frequenzverdreifachungseinheit zur Erzeugung höherer Harmonischer aufgebaut. Die Anwendbarkeit eines solchen reinen Festkörper-Lasersystems wurde in zahlreichen off-line Testmessungen sowohl in Mainz als auch an den ISOL Einrichtungen am TRIUMF und ORNL gezeigt und führte zum ersten on-line Einsatz am TRIUMF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray laser fluorescence spectroscopy of the 2s-2p transition in Li-like ions is promising to become a widely applicable tool to provide information on the nuclear charge radii of stable and radioactive isotopes. For performing such experiments at the Experimental Storage Ring ESR, and the future NESR within the FAIR Project, a grazing incidence pumped (GRIP) x-ray laser (XRL) was set up at GSI Darmstadt using PHELIX (Petawatt High Energy Laser for heavy Ions eXperiments). The experiments demonstrated that lasing using the GRIP geometry could be achieved with relatively low pump energy, a prerequisite for higher repetition rate. In the first chapter the need of a plasma XRL is motivated and a short history of the plasma XRL is presented. The distinctive characteristic of the GRIP method is the controlled deposition of the pump laser energy into the desired plasma density region. While up to now the analysis performed were mostly concerned with the plasma density at the turning point of the main pump pulse, in this thesis it is demonstrated that also the energy deposition is significantly modified for the GRIP method, being sensitive in different ways to a large number of parameters. In the second chapter, the theoretical description of the plasma evolution, active medium and XRL emission properties are reviewed. In addition an innovative analysis of the laser absorption in plasma which includes an inverse Bremsstrahlung (IB) correction factor is presented. The third chapter gives an overview of the experimental set-up and diagnostics, providing an analytical formula for the average and instantaneous traveling wave speed generated with a tilted, on-axis spherical mirror, the only focusing system used up to now in GRIP XRL. The fourth chapter describes the experimental optimization and results. The emphasis is on the effect of the incidence angle of the main pump pulse on the absorption in plasma and on output and gain in different lasing lines. This is compared to the theoretical results for two different incidence angles. Significant corrections for the temperature evolution during the main pump pulse due to the incidence angle are demonstrated in comparison to a simple analytical model which does not take into account the pumping geometry. A much better agreement is reached by the model developed in this thesis. An interesting result is also the appearance of a central dip in the spatially resolved keV emission which was observed in the XRL experiments for the first time and correlates well with previous near field imaging and plasma density profile measurements. In the conclusion also an outlook to the generation of shorter wavelength XRL’s is given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordinated patterns of electrical activity are important for the early development of sensory systems. The spatiotemporal dynamics of these early activity patterns and the role of the peripheral sensory input for their generation are essentially unknown. There are two projects in this thesis. In project1, we performed extracellular multielectrode recordings in the somatosensory cortex of postnatal day 0 to 7 rats in vivo and observed three distinct patterns of synchronized oscillatory activity. (1) Spontaneous and periphery-driven spindle bursts of 1–2 s in duration and ~10 Hz in frequency occurred approximately every 10 s. (2) Spontaneous and sensory-driven gamma oscillations of 150–300 ms duration and 30–40 Hz in frequency occurred every 10–30 s. (3) Long oscillations appeared only every ~20 min and revealed the largest amplitude (250–750 µV) and longest duration (>40 s). These three distinct patterns of early oscillatory activity differently synchronized the neonatal cortical network. Whereas spindle bursts and gamma oscillations did not propagate and synchronized a local neuronal network of 200–400 µm in diameter, long oscillations propagated with 25–30 µm/s and synchronized 600-800 µm large ensembles. All three activity patterns were triggered by sensory activation. Single electrical stimulation of the whisker pad or tactile whisker activation elicited neocortical spindle bursts and gamma activity. Long oscillations could be only evoked by repetitive sensory stimulation. The neonatal oscillatory patterns in vivo depended on NMDAreceptor-mediated synaptic transmission and gap junctional coupling. Whereas spindle bursts and gamma oscillations may represent an early functional columnar-like pattern, long oscillations may serve as a propagating activation signal consolidating these immature neuronal networks. In project2, Using voltage-sensitive dye imaging and simultaneous multi-channel extracellular recordings in the barrel cortex and somatosensory thalamus of newborn rats in vivo, we found that spontaneous and whisker stimulation induced activity patterns were restricted to functional cortical columns already at the day of birth. Spontaneous and stimulus evoked cortical activity consisted of gamma oscillations followed by spindle bursts. Spontaneous events were mainly generated in the thalamus or by spontaneous whisker movements. Our findings indicate that during early developmental stages cortical networks self-organize in ontogenetic columns via spontaneous gamma oscillations triggered by the thalamus or sensory periphery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die vorliegende klinische Studie hatte zum Ziel, die mikrovaskuläre Endothelfunktion retinaler und dermaler Gefäße von Insulinresistenten und Typ 2- Diabetikern ohne Zeichen einer diabetischen Retinopathie mit einer gesunden insulinsensitiven nicht-diabetischen Kontrollgruppe hinsichtlich früher morphologischer und funktioneller Veränderungen zu vergleichen.rnrnMethode:rnEs wurden 54 Patienten ohne Nachweis einer diabetischen Retinopathie eingeschlossen und in 3 Gruppen entsprechend ihren metabolischen Ergebnissen eingeteilt: 1.) Gruppe K (Kontrollgruppe) setzte sich aus gesunden, nicht-diabetischen, insulin-sensitiven rn(HOMA ≤ 2) Probanden mit einem BMI ≤ 28 kg/m2 zusammen; 2.) Gruppe IR bestand aus den nicht-diabetischen, insulin-resistenten (HOMAs > 2), übergewichtigen Patienten mit einem BMI > 28 kg/m2 und 3.) Gruppe DM war definiert als Patienten mit einem manifesten Typ 2-Diabetes mellitus.rnrnDie mikrovaskuläre Funktion der Retina wurde mittels eines Laserdoppler-Verfahrens (Heidelberg Retina Flowmeter) untersucht und hierbei der retinale Blutfluss und das Verhältnis der Gefäßwand zum Lumen (WLR, wall-to-lumen-ratio) basal und nach Flickerlicht-Stimulation (10 Hz, Photo Stimulator 750) gemessen. Letzterer gilt als Marker für vaskuläre Schädigung. rnZusätzlich wurde die dermale Mikrozirkulation (Blutfluss, O2-Sättigung) als weiterer Faktor der mikrovaskulären Endothelfunktion in den 3 Studiengruppen untersucht und miteinander verglichen.rnErgebnisse:rnEs zeigte sich kein signifikanter Unterschied des retinalen Blutflusses zwischen den 3 Gruppen weder basal noch nach Flickerlicht-Stimulation. Es zeigte sich keine Korrelation zwischen der mikrovaskulären Funktion der Haut und der Retina. rnDie arterielle WLR zeigte nur geringe Unterscheide zwischen den 3 Gruppen.rnrnMit zunehmendem Grad der Insulinresistenz wurde jedoch eine Reduktion des basalen als auch des flickerlicht-stimulierten retinalen Blutflusses deutlich, dabei zeigte sich unerwarteter Weise eine Abnahme der WLR.rnrnDer (prä-ischämische) muskuläre Blutfluss war in der IR-Gruppe signifikant geringer als in der K-Gruppe. Auch war die postischämische dermale O2-Sättigung in der DM und IR-Gruppe signifikant niedriger im Vergleich zur K-Gruppe. Jedoch war die postischämische hyperämische dermale Reaktion in der IR und DM-Gruppe nur geringgradig weniger als in der K-Gruppe. rnrnSchlussfolgerung:rnEine Korrelation zwischen der Entwicklung der Insulinresistenz und retinaler sowie dermaler mikrovaskulärer endothelialer Funktion wurde bei der Studie deutlich. Mithilfe des neuen Verfahrens der Laser Scanner Flowmeter zur Messung der retinalen Endothelfunktion lassen sich sehr frühe morphologische Veränderungen des mikrovaskulären Blutflusses erfassen. rnDie fehlende Korrelation zwischen retinaler und dermaler mikrovaskulärer Funktion als auch die geringen Unterschiede der WLR sollte Gegenstand weiterer Studien seinrn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atmosphärische Aerosolpartikel wirken in vielerlei Hinsicht auf die Menschen und die Umwelt ein. Eine genaue Charakterisierung der Partikel hilft deren Wirken zu verstehen und dessen Folgen einzuschätzen. Partikel können hinsichtlich ihrer Größe, ihrer Form und ihrer chemischen Zusammensetzung charakterisiert werden. Mit der Laserablationsmassenspektrometrie ist es möglich die Größe und die chemische Zusammensetzung einzelner Aerosolpartikel zu bestimmen. Im Rahmen dieser Arbeit wurde das SPLAT (Single Particle Laser Ablation Time-of-flight mass spectrometer) zur besseren Analyse insbesondere von atmosphärischen Aerosolpartikeln weiterentwickelt. Der Aerosoleinlass wurde dahingehend optimiert, einen möglichst weiten Partikelgrößenbereich (80 nm - 3 µm) in das SPLAT zu transferieren und zu einem feinen Strahl zu bündeln. Eine neue Beschreibung für die Beziehung der Partikelgröße zu ihrer Geschwindigkeit im Vakuum wurde gefunden. Die Justage des Einlasses wurde mithilfe von Schrittmotoren automatisiert. Die optische Detektion der Partikel wurde so verbessert, dass Partikel mit einer Größe < 100 nm erfasst werden können. Aufbauend auf der optischen Detektion und der automatischen Verkippung des Einlasses wurde eine neue Methode zur Charakterisierung des Partikelstrahls entwickelt. Die Steuerelektronik des SPLAT wurde verbessert, so dass die maximale Analysefrequenz nur durch den Ablationslaser begrenzt wird, der höchsten mit etwa 10 Hz ablatieren kann. Durch eine Optimierung des Vakuumsystems wurde der Ionenverlust im Massenspektrometer um den Faktor 4 verringert.rnrnNeben den hardwareseitigen Weiterentwicklungen des SPLAT bestand ein Großteil dieser Arbeit in der Konzipierung und Implementierung einer Softwarelösung zur Analyse der mit dem SPLAT gewonnenen Rohdaten. CRISP (Concise Retrieval of Information from Single Particles) ist ein auf IGOR PRO (Wavemetrics, USA) aufbauendes Softwarepaket, das die effiziente Auswertung der Einzelpartikel Rohdaten erlaubt. CRISP enthält einen neu entwickelten Algorithmus zur automatischen Massenkalibration jedes einzelnen Massenspektrums, inklusive der Unterdrückung von Rauschen und von Problemen mit Signalen die ein intensives Tailing aufweisen. CRISP stellt Methoden zur automatischen Klassifizierung der Partikel zur Verfügung. Implementiert sind k-means, fuzzy-c-means und eine Form der hierarchischen Einteilung auf Basis eines minimal aufspannenden Baumes. CRISP bietet die Möglichkeit die Daten vorzubehandeln, damit die automatische Einteilung der Partikel schneller abläuft und die Ergebnisse eine höhere Qualität aufweisen. Daneben kann CRISP auf einfache Art und Weise Partikel anhand vorgebener Kriterien sortieren. Die CRISP zugrundeliegende Daten- und Infrastruktur wurde in Hinblick auf Wartung und Erweiterbarkeit erstellt. rnrnIm Rahmen der Arbeit wurde das SPLAT in mehreren Kampagnen erfolgreich eingesetzt und die Fähigkeiten von CRISP konnten anhand der gewonnen Datensätze gezeigt werden.rnrnDas SPLAT ist nun in der Lage effizient im Feldeinsatz zur Charakterisierung des atmosphärischen Aerosols betrieben zu werden, während CRISP eine schnelle und gezielte Auswertung der Daten ermöglicht.