2 resultados para Parametric Linear System

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work seismic upgrading of existing masonry structures by means of hysteretic ADAS dampers is treated. ADAS are installed on external concrete walls, which are built parallel to the building, and then linked to the building's slab by means of steel rod connection system. In order to assess the effectiveness of the intervention, a parametric study considering variation of damper main features has been conducted. To this aim, the concepts of equivalent linear system (ELS) or equivalent viscous damping are deepen. Simplified equivalent linear model results are then checked respect results of the yielding structures. Two alternative displacement based methods for damper design are herein proposed. Both methods have been validated through non linear time history analyses with spectrum compatible accelerograms. Finally ADAS arrangement for the non conventional implementation is proposed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The seismic behaviour of one-storey asymmetric structures has been studied since 1970s by a number of researches studies which identified the coupled nature of the translational-to-torsional response of those class of systems leading to severe displacement magnifications at the perimeter frames and therefore to significant increase of local peak seismic demand to the structural elements with respect to those of equivalent not-eccentric systems (Kan and Chopra 1987). These studies identified the fundamental parameters (such as the fundamental period TL normalized eccentricity e and the torsional-to-lateral frequency ratio Ωϑ) governing the torsional behavior of in-plan asymmetric structures and trends of behavior. It has been clearly recognized that asymmetric structures characterized by Ωϑ >1, referred to as torsionally-stiff systems, behave quite different form structures with Ωϑ <1, referred to as torsionally-flexible systems. Previous research works by some of the authors proposed a simple closed-form estimation of the maximum torsional response of one-storey elastic systems (Trombetti et al. 2005 and Palermo et al. 2010) leading to the so called “Alpha-method” for the evaluation of the displacement magnification factors at the corner sides. The present paper provides an upgrade of the “Alpha Method” removing the assumption of linear elastic response of the system. The main objective is to evaluate how the excursion of the structural elements in the inelastic field (due to the reaching of yield strength) affects the displacement demand of one-storey in-plan asymmetric structures. The system proposed by Chopra and Goel in 2007, which is claimed to be able to capture the main features of the non-linear response of in-plan asymmetric system, is used to perform a large parametric analysis varying all the fundamental parameters of the system, including the inelastic demand by varying the force reduction factor from 2 to 5. Magnification factors for different force reduction factor are proposed and comparisons with the results obtained from linear analysis are provided.