7 resultados para DISPLACEMENT PILE

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the work is: define and calculate a factor of collapse related to traditional method to design sheet pile walls. Furthermore, we tried to find the parameters that most influence a finite element model representative of this problem. The text is structured in this way: from chapter 1 to 5, we analyzed a series of arguments which are usefull to understanding the problem, while the considerations mainly related to the purpose of the text are reported in the chapters from 6 to 10. In the first part of the document the following arguments are shown: what is a sheet pile wall, what are the codes to be followed for the design of these structures and what they say, how can be formulated a mathematical model of the soil, some fundamentals of finite element analysis, and finally, what are the traditional methods that support the design of sheet pile walls. In the chapter 6 we performed a parametric analysis, giving an answer to the second part of the purpose of the work. Comparing the results from a laboratory test for a cantilever sheet pile wall in a sandy soil, with those provided by a finite element model of the same problem, we concluded that:in modelling a sandy soil we should pay attention to the value of cohesion that we insert in the model (some programs, like Abaqus, don’t accept a null value for this parameter), friction angle and elastic modulus of the soil, they influence significantly the behavior of the system (structure-soil), others parameters, like the dilatancy angle or the Poisson’s ratio, they don’t seem influence it. The logical path that we followed in the second part of the text is reported here. We analyzed two different structures, the first is able to support an excavation of 4 m, while the second an excavation of 7 m. Both structures are first designed by using the traditional method, then these structures are implemented in a finite element program (Abaqus), and they are pushed to collapse by decreasing the friction angle of the soil. The factor of collapse is the ratio between tangents of the initial friction angle and of the friction angle at collapse. At the end, we performed a more detailed analysis of the first structure, observing that, the value of the factor of collapse is influenced by a wide range of parameters including: the value of the coefficients assumed in the traditional method and by the relative stiffness of the structure-soil system. In the majority of cases, we found that the value of the factor of collapse is between and 1.25 and 2. With some considerations, reported in the text, we can compare the values so far found, with the value of the safety factor proposed by the code (linked to the friction angle of the soil).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Progetto di riqualificazione urbana di un'area industriale attraverso il riordino del verde. Inserimento di laboratori di ricerca e incubatori d'impresa e coworking e riorganizzazione degli impianti sportivi preesistenti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descrizione dei vantaggi della tecnologia delle fondazioni da pozzo per le pile da ponte. Analisi dei carichi di un viadotto esistente a struttura mista e studio agli stati limite delle più svantaggiose condizioni di carico. Analisi sismica della pila. Progetto e verifica della pila, del plinto e del pozzo nelle diverse fasi di realizzazione e per le combinazioni di carico considerate. Verifiche del terreno, con riferimento ai criteri di dimensionamento del Prof. Jamiolkowski. Analisi tenso-deformativa del terreno con software Plaxis2D e Midas-GTS (3D). Confronti fra il metodo analitico adottato nelle verifiche ed i risultati numerici. Norme di riferimento: NTC2008, Istruzione N°I/SC/PS-OM/2298, Ordinanza 3274 come modificato dall'OPCM 3431

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laterally loaded piles are a typical situation for a large number of cases in which deep foundations are used. Dissertation herein reported, is a focus upon the numerical simulation of laterally loaded piles. In the first chapter the best model settings are largely discussed, so a clear idea about the effects of interface adoption, model dimension, refinement cluster and mesh coarseness is reached. At a second stage, there are three distinct parametric analyses, in which the model response sensibility is studied for variation of interface reduction factor, Eps50 and tensile cut-off. In addition, the adoption of an advanced soil model is analysed (NGI-ADP). This was done in order to use the complex behaviour (different undrained shear strengths are involved) that governs the resisting process of clay under short time static loads. Once set a definitive model, a series of analyses has been carried out with the objective of defining the resistance-deflection (P-y) curves for Plaxis3D (2013) data. Major results of a large number of comparisons made with curves from API (America Petroleum Institute) recommendation are that the empirical curves have almost the same ultimate resistance but a bigger initial stiffness. In the second part of the thesis a simplified structural preliminary design of a jacket structure has been carried out to evaluate the environmental forces that act on it and on its piles foundation. Finally, pile lateral response is studied using the empirical curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valutazione di metori per la progettazione di isolatori da ponte mediante DDBD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questo studio concerne uno studio di fattibilità per l'applicazione dei "positive displacement motors" in ambienti ambienti fortemente critici, soggetti ad alta pressione e alta temperatura. Tali motori sono utilizzati nell'industria Oil & Gas per la perforazione di pozzi petroliferi. L’analisi è stata portata a termine attraverso definizione dell’intervallo di temperatura per cui le performance degli strumenti in commercio presenta il maggior numero di failures, compreso tra i 175°C e i 225°C , e per il quale si vuole riuscire a limitare i rischi connessi e le criticità associate, garantendo così il raggiungimento dei target con un maggior grado di affidabilità e disponibilità del PDM utilizzato. Analizzando le sollecitazioni agenti sul motore durante le fasi di utilizzo, è stato possibile rilevare le principali cause di rottura e malfunzionamento che, nella maggior parte dei casi, possono essere attribuite al rigonfiamento e alla degradazione del materiale elastomerico che costituisce lo statore della power section. Investigando in merito alle differenze e alle proprietà di resistenza di numerosi materiali elastomerici a diversi range di temperatura, sono stati evidenziati dei margini di ottimizzazione in particolare relativi alla potenziale riduzione e totale sostituzione della superficie elastomerica con materiale metallico. Ciò ha fatto si che fosse necessario un approfondimento sulle caratteristiche degli acciai e delle leghe metalliche, in termini di resistenza a corrosione, costo del materiale, resistenza meccanica e della capacità di mantenere elevate proprietà meccaniche con l’aumento della temperatura, al fine di individuare i migliori “candidati” per sostituire interamente il materiale elastomerico dello statore in materiale metallico e risolvere così il problema dell’applicazione dei PDM in ambienti HT-HP.