40 resultados para nanowire transistor
Resumo:
Metal nanowires (NWs) - nanostructures 20-100 nm in diameter and up to tens of micrometers long - behave as waveguides when irradiated with light with wavelength much greater than their diameter. This is due to collective excitations of free electrons (plasmons) in the metal which couple to light and travel on the surface of the nanowire. This effect can be used to efficiently absorb laser pulses to produce dense and hot plasma on special nanostructured targets with metal nanowires vertically aligned on the surface. In this thesis work, nanostructured targets with different parameters (length, diameter, metal and fabrication process) have been irradiated with infrared laser light. X-ray flux emitted by the cooling plasma is measured during irradiation, and the depth of craters formed on the target is measured later. This data is used to choose which target parameters are best for plasma production. Different targets are compared with each other and against a control, non-nanostructured (bulk) target. As will be shown, highly significant (> 5 sigma) differences are found between targets with different nanostructures, and between nanostructured and bulk target. This differences are very difficult to explain whithout accounting for the nanostructures in the targets. Therefore, data collected and analized in this thesis work supports the hypotesys that nanostructured targets perform better than bulk targets for laser plasma production purposes, and provides useful indications for optimization of NWS' parameters.
Resumo:
Oggigiorno, a causa dell’aumento delle emissioni gassose di ammoniaca, occorre far fronte alla necessità di salvaguardare l’ambiente e la salute degli esseri viventi. A tale scopo, stanno acquisendo sempre più interesse dispositivi portatili che forniscano quantificazioni accurate. Grazie alle interessanti prestazioni esibite dai transistor elettrochimici organici (OECTs) a base di PEDOT:PSS, per la quantificazione di analiti in ambiente acquoso, nasce l’idea di realizzare un sensore elettrochimico ad essi ispirato e in grado di effettuare determinazioni in fase gas. Si vuole realizzare una tipologia di sensore a due terminali che unisca l’elettronica di lettura semplificata, l’amplificazione del segnale e il basso apporto di energia necessario garantito dagli OECTs, ad una geometria adeguata anche per applicazioni non convenzionali. Tale dispositivo viene modificato tramite elettrodeposizione di particelle di IrO2 per rendere il canale polimerico sensibile alle variazioni di pH e sottoposto a dip coating in un idrogel semi-solido per garantire la presenza di un’interfaccia efficace tra il materiale sensibile e l’aria circostante in cui si vuole quantificare ammoniaca. Questo lavoro di tesi ha comportato una prima fase di progettazione del sensore, dove vengono valutati i parametri di deposizione e caratterizzazione delle particelle sintetizzate e del materiale composito finale, la corretta formulazione del substrato gel per un’interfaccia solido-gas efficace ed una seconda, dove l’attenzione è invece volta all’ottimizzazione della risposta elettrochimica e delle prestazioni del sensore, con particolare riguardo verso ripetibilità, riproducibilità delle misure, tempo di risposta e limite di rivelabilità. Al termine del lavoro si raggiunge l’ottimizzazione di un sensore elettrochimico a due terminali per la quantificazione di ammoniaca gassosa che, grazie alla sua geometria, si presta anche ad applicazioni wearable nel campo dei materiali intelligenti.
Resumo:
I moderni processori multi-core ad elevate prestazioni sono alimentati da regolatori di tensione integrati direttamente sul chip. Questi regolatori forniscono a ciascun power domain la tensione ottimale sulla base della sua attività, monitorata da una Power Control Unit. Questo consente da un lato di ottenere una riduzione dei consumi, dall'altro di avere un boost delle prestazioni in particolari contesti. Tali regolatori integrati sul die sono affetti da guasti e fenomeni di aging, che possono compromettere il corretto funzionamento del circuito. Questi problemi non sono tollerabili in contesti caratterizzati da esigenze di elevata reliability, come l'autonomous driving. Dunque, è stato sviluppato un monitor per rivelare on-line eventuali guasti che possono verificarsi durante il normale funzionamento sul campo. In caso di guasto il monitor è in grado di dare un'indicazione d'errore, che può essere utilizzata per attivare delle procedure di recovery. La soluzione proposta, basata su un approccio completamente differente rispetto a quello suggerito dallo standard ISO 26262, beneficia, rispetto a quest'ultima, di costi nettamente inferiori e prestazioni superiori. Il monitor può essere calibrato automaticamente per compensare le variazioni dei parametri di processo ed i fenomeni di aging che possono affliggere il monitor stesso. È stata verificata la self-checking ability del monitor rispetto a guasti di tipo transistor stuck-on, transistor stuck-open e bridging resistivo, risultando Totally Self-Checking rispetto all'insieme di guasti considerato.
Resumo:
Conductive polymers (CPS) are a class of carbon-based materials, capable of conducting electric current, characterized by metallic properties in combination with the intrinsic properties of conventional polymers. The structural model of the CP consists of a system of double π-conjugated on the backbone (polyene structure) which can easily undergo reversible doping reaching a wide range of conductivity. Thanks to their versatility and peculiar properties (mechanical flexibility, biocompatibility, transparency, ease of chemical functionalization, high thermal stability), CPS have revolutionized the science of materials giving rise to Organic Bioelectronics, the discipline resulting from the convergence between biology and electronics. The Poly (3,4-ethylenedioxythiophene) : poly (styrenesulfonate) (PEDOT: PSS), complex polyelectrolyte, in the form of a thin film, currently represents the reference standard in applications concerning Bioelectronics. In this project, two types of electrochemical sensors ink-jet printed on a flexible polymeric substrate, the polyethylene terephthalate, have been developed and characterized. The Drop on Demand (DOD) inkjet technology has allowed to control the positioning of fluid volumes of the order of picoliters with an accuracy of ± 25μm. This resulted in the creation of amperometric sensors and organic electrochemical transistors (OECT) all-PEDOT: PSS with high reproducibility. The sensors have been used for the determination of Ascorbic Acid (AA) which is currently considered an important benchmark in the field of sensors. In Cyclic Voltammetry, the amperometric sensor has detected AA at potentials less than 0.2 V vs. SCE thanks to the electrocatalytic properties of the PEDOT: PSS. On the other hand, the OECT detected AA concentrations equal to 10 nanomolar in Chronoamperometry. Furthermore, a promising new generation of all-printed OECTS, consisting of silver metal contacts, has been created. Preliminary results are presented.
Resumo:
Amorphous semiconductors are important materials as they can be deposited by physical deposition techniques on large areas and even on plastic substrates. Therefore, they are crucial for transistors in large active matrices for imaging and transparent wearable electronics. The most widely applied candidate for amorphous thin film transistors production is Indium Gallium Zinc Oxide (IGZO). It is attracting much interest because of its optical transparency, facile processing by sputtering deposition and notable improved charge carrier mobility with respect to hydrogenated amorphous silicon a-Si:H. Degradation of the device and long-term performance issues have been observed if IGZO thin film transistors are subjected to electrical stress, leading to a modification of IGZO channel properties and subthreshold slope. Therefore, it is of great interest to have a reliable and precise method to study the conduction band tail, and the density of states in amorphous semiconductors. The aim of this thesis is to develop a local technique using Kelvin Probe Force Microscopy to study the evolution of IGZO DOS properties. The work is divided into three main parts. First, solutions to the non-linear Poisson-Boltzmann equation of a metal-insulator-semiconductor junction describing the charge accumulation and its relation to DOS properties are elaborated. Second macroscopic techniques such as capacitance voltage (CV) measurements and photocurrent spectroscopy are applied to obtain a non-local estimate of band-tail DOS properties in thin film transistor samples. The third part of my my thesis is dedicated to the KPFM measurements. By fitting the data to the developed numerical model, important parameters describing the amorphous conduction band tail are obtained. The results are in excellent agreement with the macroscopic characterizations. KPFM result is comparable also with non-local optoelectronic characterizations, such as photocurrent spectroscopy.
Resumo:
Lo scopo del presente progetto di ricerca è quello di dimostrare quelli che potrebbero essere i miglioramenti nell’adottare tecnologie GaN nei convertitori di potenza, soffermandosi sull’ambito Automotive. Si è dunque progettato, simulato ed infine analizzato un sistema di conversione bidirezionale DC-DC. Le prestazioni ottime sono state poi raggiunte attraverso l’introduzione di un sistema di controllo in grado di garantire, in ogni condizione, il miglior funzionamento possibile che garantisca il soddisfacimento delle richieste da parte del veicolo. Questo consentirà quindi di gestire il funzionamento del convertitore sia nelle fasi di scarica che in quelle di rigenerazione (regenerative braking). Al convertitore, è stato introdotto anche un controllo adattivo per la ricerca del dead-time ottimo dei segnali di pilotaggio dei transistor.
Resumo:
Fino a 15 anni fa, era possibile aumentare il numero di transistor su un singolo chip e contemporaneamente la sua frequenza di clock mantenendo la densità di potenza costante. Tuttavia dal 2004 non è più possibile mantenere invariata la potenza dissipata per unità d’area a causa di limitazioni fisiche. Al fine di aumentare le performance dei processori e di impedire una diminuzione delle frequenze di clock, i processori moderni integrano on-die dei Power Controller Subsystems (PCS) come risorsa hardware dedicata che implementa complesse strategie di gestione di temperatura e potenza. In questo progetto di tesi viene progettata l'architettura dell'interfaccia di comunicazione di ControlPULP, un PCS basato su ISA RISC-V, per la connessione verso un processore HPC. Tale interfaccia di comunicaione integra il supporto hardware per lo scambio di messaggi secondo la specifica SCMI. L'interfaccia sviluppata viene successivamente validata attraverso simulazione ed emulazione su supporto hardware FPGA. Tale supporto hardware viene inoltre utilizzato per la caratterizzazione dell'utilizzo di risorse dell'architettura progettata. Oltre allo sviluppo dell'interfaccia hardware viene sviluppato e caratterizzato un firmware per la decodifica dei messaggi SCMI conforme ai requisiti di esecuzione su un sistema real-time.
Resumo:
I sensori indossabili rappresentano una frontiera della ricerca scientifica e, allo stesso tempo, a livello commerciale sono un nuovo mercato emergente. La possibilità di studiare diversi parametri fisiologici con dispositivi versatili e di dimensioni ridotte è importante per raggiungere una comprensione più profonda dei diversi fenomeni che avvengono nel nostro corpo. In maniera simile, la composizione dell’essudato di una ferita è finemente legata all’evoluzione del processo di guarigione, che comporta diversi meccanismi di rigenerazione del tessuto connettivo e dell’epitelio. Grazie ai dispositivi indossabili, si apre la possibilità di monitorare i componenti chiave di questi processi. I wearable devices costituiscono quindi sia uno strumento diagnostico, che uno strumento clinico per l’identificazione e la valutazione di strategie terapeutiche più efficienti. Il mio lavoro di tirocinio si è incentrato sulla fabbricazione, caratterizzazione e sperimentazione delle performance di transistor elettrochimici a base organica (OECT) tessili per la misurazione dei livelli di pH ed acido urico. L’obbiettivo del gruppo di ricerca è quello di realizzare un cerotto intelligente che abbia due diversi elementi sensibili, uno per l’acido urico e l’altro per la concentrazione idrogenionica. Per il raggiungimento di tale scopo, si è sfruttato uno dei semiconduttori organici più utilizzati e studiati nell’ultimo periodo, il PEDOT, ovvero il poli(3,4-etilen-diossi-tiofene), che risulta anche uno dei materiali principalmente impiegati nella ricerca sui sensori tessili.
Resumo:
Wearable biosensors are attracting interest due to their potential to provide continuous, real-time physiological information via dynamic, non-invasive measurements of biochemical markers in biofluids, such as interstitial fluid (ISF). One notable example of their applications is for glycemic monitoring in diabetic patients, which is typically carried out either by direct measurement of blood glucose via finger pricking or by wearable sensors that can continuously monitor glucose in ISF by sampling it from below the skin with a microneedle. In this context, the development of a new and minimally invasive multisensing tattoo-based platform for the monitoring of glucose and other analytes in ISF extracted through reverse iontophoresis in proposed by the GLUCOMFORT project. This elaborate describes the in-vitro development of flexible electrochemical sensors based on inkjet-printed PEDOT:PSS and metal inks that are capable of determining glucose and chloride at biologically relevant concentrations, making them good candidates for application in the GLUCOMFORT platform. In order to make PEDOT:PSS sensitive to glucose at micromolar concentrations, a biocompatible functionalization based on immobilized glucose oxidase and electrodeposited platinum was developed. This functionalization was successfully applied to bulk and flexible amperometric devices, the design of which was also optimized. Using the same strategy, flexible organic electrochemical transistors (OECTs) for glucose sensing were also made and successfully tested. For the sensing of chloride ions, an organic charge-modulated field-effect transistor (OCMFET) featuring a silver/silver chloride modified floating gate electrode was developed and tested.
Resumo:
Una sempre crescente quantità di informazione digitale viene condivisa tra miliardi di dispositivi connessi in ogni angolo del pianeta. Per riuscire a sfruttare una banda più ampia ed aumentare la velocità di trasmissione dei dati, i prossimi standard di telecomunicazioni wireless dovranno adoperare frequenze operative sempre più alte, cercando di rispettare stringenti specifiche in termini di affidabilità ed efficienza energetica. In generale, le prestazioni di un transistor dipenderanno dalle terminazioni a cui esso è collegato. In un setup di caratterizzazione e test, è possibile, tramite un metodo noto come load pull attivo, sintetizzare un determinato valore di impedenza ad uno o più piani di riferimento all'interno di un circuito. Questa strategia si basa in generale sulla manipolazione del rapporto tra onde entranti ed uscenti da un piano di riferimento del dispositivo. Se da una parte tecniche di load pull attivo a banda larga a radiofrequenza hanno ricevuto un notevole interesse sia commerciale che accademico, dall'altra le strategie per la sintesi di impedenze presenti al terminale di alimentazione dell'amplificatore, sono state meno investigate. Questo elaborato si propone di introdurre un algoritmo per il load pull attivo a banda base per amplificatori per applicazioni RF. Dopo un'introduzione sui modelli comportamentali degli amplificatori, è stato considerato il problema degli effetti di memoria. È stata poi descritta la tecnica per l'emulazione di impedenze. Dapprima, è stato considerato il caso lineare. Poi, tramite il design di un amplificatore di potenza per applicazioni a radio frequenza usato come device under test (DUT), sono stati affrontati due esempi in presenza di non linearità, verificando la correttezza della tecnica proposta tramite l'uso di simulazioni.