20 resultados para energy performance
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
The research activity described in this thesis is focused mainly on the study of finite-element techniques applied to thermo-fluid dynamic problems of plant components and on the study of dynamic simulation techniques applied to integrated building design in order to enhance the energy performance of the building. The first part of this doctorate thesis is a broad dissertation on second law analysis of thermodynamic processes with the purpose of including the issue of the energy efficiency of buildings within a wider cultural context which is usually not considered by professionals in the energy sector. In particular, the first chapter includes, a rigorous scheme for the deduction of the expressions for molar exergy and molar flow exergy of pure chemical fuels. The study shows that molar exergy and molar flow exergy coincide when the temperature and pressure of the fuel are equal to those of the environment in which the combustion reaction takes place. A simple method to determine the Gibbs free energy for non-standard values of the temperature and pressure of the environment is then clarified. For hydrogen, carbon dioxide, and several hydrocarbons, the dependence of the molar exergy on the temperature and relative humidity of the environment is reported, together with an evaluation of molar exergy and molar flow exergy when the temperature and pressure of the fuel are different from those of the environment. As an application of second law analysis, a comparison of the thermodynamic efficiency of a condensing boiler and of a heat pump is also reported. The second chapter presents a study of borehole heat exchangers, that is, a polyethylene piping network buried in the soil which allows a ground-coupled heat pump to exchange heat with the ground. After a brief overview of low-enthalpy geothermal plants, an apparatus designed and assembled by the author to carry out thermal response tests is presented. Data obtained by means of in situ thermal response tests are reported and evaluated by means of a finite-element simulation method, implemented through the software package COMSOL Multyphysics. The simulation method allows the determination of the precise value of the effective thermal properties of the ground and of the grout, which are essential for the design of borehole heat exchangers. In addition to the study of a single plant component, namely the borehole heat exchanger, in the third chapter is presented a thorough process for the plant design of a zero carbon building complex. The plant is composed of: 1) a ground-coupled heat pump system for space heating and cooling, with electricity supplied by photovoltaic solar collectors; 2) air dehumidifiers; 3) thermal solar collectors to match 70% of domestic hot water energy use, and a wood pellet boiler for the remaining domestic hot water energy use and for exceptional winter peaks. This chapter includes the design methodology adopted: 1) dynamic simulation of the building complex with the software package TRNSYS for evaluating the energy requirements of the building complex; 2) ground-coupled heat pumps modelled by means of TRNSYS; and 3) evaluation of the total length of the borehole heat exchanger by an iterative method developed by the author. An economic feasibility and an exergy analysis of the proposed plant, compared with two other plants, are reported. The exergy analysis was performed by considering the embodied energy of the components of each plant and the exergy loss during the functioning of the plants.
Resumo:
The general aim of this work is to contribute to the energy performance assessment of ventilated façades by the simultaneous use of experimental data and numerical simulations. A significant amount of experimental work was done on different types of ventilated façades with natural ventilation. The measurements were taken on a test building. The external walls of this tower are rainscreen ventilated façades. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to investigate the best summer thermal performance of rainscreen ventilated skin façade a study for different setups of rainscreen walls was made. In particular, influences of ventilation grills, air cavity thickness, skin colour, skin material, orientation of façade were investigated. It is shown that some types of rainscreen ventilated façade typologies are capable of lowering the cooling energy demand of a few percent points.
Resumo:
Il presente studio si colloca all’interno di una ricerca più ampia volta alla definizione di criteri progettuali finalizzati all’ottimizzazione delle prestazioni energetiche delle cantine di aziende vitivinicole, di dimensioni produttive medio - piccole. Nello specifico la ricerca riguarda la riqualificazione di fabbricati rurali esistenti di modeste dimensioni, da convertire a magazzini per la conservazione del vino in bottiglia. Lo studio si pone come obiettivo la definizione di criteri di analisi per la valutazione di interventi di retrofit di tali fabbricati, volto sia al miglioramento delle prestazioni energetiche dell’involucro edilizio, sia alla riduzione del fabbisogno energetico legato al funzionamento di eventuali impianti di controllo termico. La ricerca è stata condotta mediante l’utilizzo del software di simulazione termica Energy Plus, per ottenere i valori simulati di temperatura interna relativi ai diversi scenari migliorativi ipotizzati, e mediante la successiva definizione di indicatori che esplicitino l’influenza delle principali variabili progettuali sull’andamento delle temperature interne dei locali di conservazione e sul fabbisogno energetico del fabbricato necessario a garantire l’intervallo di temperatura di comfort del vino. Tra tutti gli interventi possibili per il miglioramento della prestazione energetica degli edifici, quelli analizzati in questo studio prevedono l’aggiunta di un isolamento a cappotto delle pareti esterne, l’isolamento della copertura e l’aggiunta di una struttura ombreggiante vegetale esterna. I risultati ottenuti danno una prima indicazione sugli interventi più efficaci in termini di miglioramento energetico e mettono in luce l’utilità del criterio proposto nell’evidenziare le criticità degli interventi migliorativi ipotizzati. Il metodo definito nella presente ricerca risulta quindi un valido strumento di valutazione a supporto della progettazione degli interventi di retrofit dei fabbricati rurali da convertire a magazzini per la conservazione del vino.
Resumo:
In this Thesis a series of numerical models for the evaluation of the seasonal performance of reversible air-to-water heat pump systems coupled to residential and non-residential buildings are presented. The exploitation of the energy saving potential linked to the adoption of heat pumps is a hard task for designers due to the influence on their energy performance of several factors, like the external climate variability, the heat pump modulation capacity, the system control strategy and the hydronic loop configuration. The aim of this work is to study in detail all these aspects. In the first part of this Thesis a series of models which use a temperature class approach for the prediction of the seasonal performance of reversible air source heat pumps are shown. An innovative methodology for the calculation of the seasonal performance of an air-to-water heat pump has been proposed as an extension of the procedure reported by the European standard EN 14825. This methodology can be applied not only to air-to-water single-stage heat pumps (On-off HPs) but also to multi-stage (MSHPs) and inverter-driven units (IDHPs). In the second part, dynamic simulation has been used with the aim to optimize the control systems of the heat pump and of the HVAC plant. A series of dynamic models, developed by means of TRNSYS, are presented to study the behavior of On-off HPs, MSHPs and IDHPs. The main goal of these dynamic simulations is to show the influence of the heat pump control strategies and of the lay-out of the hydronic loop used to couple the heat pump to the emitters on the seasonal performance of the system. A particular focus is given to the modeling of the energy losses linked to on-off cycling.
Resumo:
Power-to-Gas storage systems have the potential to address grid-stability issues that arise when an increasing share of power is generated from sources that have a highly variable output. Although the proof-of-concept of these has been promising, the behaviour of the processes in off-design conditions is not easily predictable. The primary aim of this PhD project was to evaluate the performance of an original Power-to-Gas system, made up of innovative components. To achieve this, a numerical model has been developed to simulate the characteristics and the behaviour of the several components when the whole system is coupled with a renewable source. The developed model has been applied to a large variety of scenarios, evaluating the performance of the considered process and exploiting a limited amount of experimental data. The model has been then used to compare different Power-to-Gas concepts, in a real scenario of functioning. Several goals have been achieved. In the concept phase, the possibility to thermally integrate the high temperature components has been demonstrated. Then, the parameters that affect the energy performance of a Power-to-Gas system coupled with a renewable source have been identified, providing general recommendations on the design of hybrid systems; these parameters are: 1) the ratio between the storage system size and the renewable generator size; 2) the type of coupled renewable source; 3) the related production profile. Finally, from the results of the comparative analysis, it is highlighted that configurations with a highly oversized renewable source with respect to the storage system show the maximum achievable profit.
Resumo:
La questione energetica ha assunto, negli ultimi anni, un ruolo centrale nel dibattito mondiale in relazione a quattro fattori principali: la non riproducibilità delle risorse naturali, l’aumento esponenziale dei consumi, gli interessi economici e la salvaguardia dell'equilibrio ambientale e climatico del nostro Pianeta. E’ necessario, dunque, cambiare il modello di produzione e consumo dell’energia soprattutto nelle città, dove si ha la massima concentrazione dei consumi energetici. Per queste ragioni, il ricorso alle Fonti Energetiche Rinnovabili (FER) si configura ormai come una misura necessaria, opportuna ed urgente anche nella pianificazione urbanistica. Per migliorare la prestazione energetica complessiva del sistema città bisogna implementare politiche di governo delle trasformazioni che escano da una logica operativa “edificio-centrica” e ricomprendano, oltre al singolo manufatto, le aggregazioni di manufatti e le loro relazioni/ interazioni in termini di input e output materico-energetiche. La sostituzione generalizzata del patrimonio edilizio esistente con nuovi edifici iper-tecnologici, è improponibile. In che modo quindi, è possibile ridefinire la normativa e la prassi urbanistica per generare tessuti edilizi energeticamente efficienti? La presente ricerca propone l’integrazione tra la nascente pianificazione energetica del territorio e le più consolidate norme urbanistiche, nella generazione di tessuti urbani “energy saving” che aggiungano alle prestazioni energetico-ambientali dei singoli manufatti quelle del contesto, in un bilancio energetico complessivo. Questo studio, dopo aver descritto e confrontato le principali FER oggi disponibili, suggerisce una metodologia per una valutazione preliminare del mix di tecnologie e di FER più adatto per ciascun sito configurato come “distretto energetico”. I risultati di tale processo forniscono gli elementi basilari per predisporre le azioni necessarie all’integrazione della materia energetica nei Piani Urbanistici attraverso l’applicazione dei principi della perequazione nella definizione di requisiti prestazionali alla scala insediativa, indispensabili per un corretto passaggio alla progettazione degli “oggetti” e dei “sistemi” urbani.
Resumo:
La recente Direttiva 31/2010 dell’Unione Europea impone agli stati membri di riorganizzare il quadro legislativo nazionale in materia di prestazione energetica degli edifici, affinchè tutte le nuove costruzioni presentino dal 1° gennaio 2021 un bilancio energetico tendente allo zero; termine peraltro anticipato al 1° gennaio 2019 per gli edifici pubblici. La concezione di edifici a energia “quasi” zero (nZEB) parte dal presupposto di un involucro energeticamente di standard passivo per arrivare a compensare, attraverso la produzione preferibilmente in sito di energia da fonti rinnovabili, gli esigui consumi richiesti su base annuale. In quest’ottica la riconsiderazione delle potenzialità dell’architettura solare individua degli strumenti concreti e delle valide metodologie per supportare la progettazione di involucri sempre più performanti che sfruttino pienamente una risorsa inesauribile, diffusa e alla portata di tutti come quella solare. Tutto ciò in considerazione anche della non più procrastinabile necessità di ridurre il carico energetico imputabile agli edifici, responsabili come noto di oltre il 40% dei consumi mondiali e del 24% delle emissioni di gas climalteranti. Secondo queste premesse la ricerca pone come centrale il tema dell’integrazione dei sistemi di guadagno termico, cosiddetti passivi, e di produzione energetica, cosiddetti attivi, da fonte solare nell’involucro architettonico. Il percorso sia analitico che operativo effettuato si è posto la finalità di fornire degli strumenti metodologici e pratici al progetto dell’architettura, bisognoso di un nuovo approccio integrato mirato al raggiungimento degli obiettivi di risparmio energetico. Attraverso una ricognizione generale del concetto di architettura solare e dei presupposti teorici e terminologici che stanno alla base della stessa, la ricerca ha prefigurato tre tipologie di esito finale: una codificazione delle morfologie ricorrenti nelle realizzazioni solari, un’analisi comparata del rendimento solare nelle principali aggregazioni tipologiche edilizie e una parte importante di verifica progettuale dove sono stati applicati gli assunti delle categorie precedenti
Resumo:
Il presente studio si colloca nell’ambito di una ricerca il cui obiettivo è la formulazione di criteri progettuali finalizzati alla ottimizzazione delle prestazioni energetiche delle cantine di aziende vitivinicole con dimensioni produttive medio-piccole. Nello specifico la ricerca si pone l’obiettivo di individuare degli indicatori che possano valutare l’influenza che le principali variabili progettuali hanno sul fabbisogno energetico dell’edificio e sull’andamento delle temperature all’interno dei locali di conservazione ed invecchiamento del vino. Tali indicatori forniscono informazioni sulla prestazione energetica dell’edificio e sull’idoneità dei locali non climatizzati finalizzata alla conservazione del vino Essendo la progettazione una complessa attività multidisciplinare, la ricerca ha previsto l’ideazione di un programma di calcolo in grado di gestire ed elaborare dati provenienti da diversi ambiti (ingegneristici, architettonici, delle produzioni agroindustriali, ecc.), e di restituire risultati sintetici attraverso indicatori allo scopo individuati. Il programma è stato applicato su un caso-studio aziendale rappresentativo del settore produttivo. Sono stati vagliati gli effetti di due modalità di vendemmia e di quattro soluzioni architettoniche differenti. Le soluzioni edilizie derivano dalla combinazione di diversi isolamenti termici e dalla presenza o meno di locali interrati. Per le analisi sul caso-studio ci si è avvalsi di simulazioni energetiche in regime dinamico, supportate e validate da campagne di monitoraggio termico e meteorologico all’interno dell’azienda oggetto di studio. I risultati ottenuti hanno evidenziato come il programma di calcolo concepito nell’ambito di questo studio individui le criticità dell’edificio in termini energetici e di “benessere termico” del vino e consenta una iterativa revisione delle variabili progettuale indagate. Esso quindi risulta essere uno strumento informatizzato di valutazione a supporto della progettazione, finalizzato ad una ottimizzazione del processo progettuale in grado di coniugare, in maniera integrata, gli obiettivi della qualità del prodotto, della efficienza produttiva e della sostenibilità economica ed ambientale.
Resumo:
Embedding intelligence in extreme edge devices allows distilling raw data acquired from sensors into actionable information, directly on IoT end-nodes. This computing paradigm, in which end-nodes no longer depend entirely on the Cloud, offers undeniable benefits, driving a large research area (TinyML) to deploy leading Machine Learning (ML) algorithms on micro-controller class of devices. To fit the limited memory storage capability of these tiny platforms, full-precision Deep Neural Networks (DNNs) are compressed by representing their data down to byte and sub-byte formats, in the integer domain. However, the current generation of micro-controller systems can barely cope with the computing requirements of QNNs. This thesis tackles the challenge from many perspectives, presenting solutions both at software and hardware levels, exploiting parallelism, heterogeneity and software programmability to guarantee high flexibility and high energy-performance proportionality. The first contribution, PULP-NN, is an optimized software computing library for QNN inference on parallel ultra-low-power (PULP) clusters of RISC-V processors, showing one order of magnitude improvements in performance and energy efficiency, compared to current State-of-the-Art (SoA) STM32 micro-controller systems (MCUs) based on ARM Cortex-M cores. The second contribution is XpulpNN, a set of RISC-V domain specific instruction set architecture (ISA) extensions to deal with sub-byte integer arithmetic computation. The solution, including the ISA extensions and the micro-architecture to support them, achieves energy efficiency comparable with dedicated DNN accelerators and surpasses the efficiency of SoA ARM Cortex-M based MCUs, such as the low-end STM32M4 and the high-end STM32H7 devices, by up to three orders of magnitude. To overcome the Von Neumann bottleneck while guaranteeing the highest flexibility, the final contribution integrates an Analog In-Memory Computing accelerator into the PULP cluster, creating a fully programmable heterogeneous fabric that demonstrates end-to-end inference capabilities of SoA MobileNetV2 models, showing two orders of magnitude performance improvements over current SoA analog/digital solutions.
Resumo:
Waste management represents an important issue in our society and Waste-to-Energy incineration plants have been playing a significant role in the last decades, showing an increased importance in Europe. One of the main issues posed by waste combustion is the generation of air contaminants. Particular concern is present about acid gases, mainly hydrogen chloride and sulfur oxides, due to their potential impact on the environment and on human health. Therefore, in the present study the main available technological options for flue gas treatment were analyzed, focusing on dry treatment systems, which are increasingly applied in Municipal Solid Wastes (MSW) incinerators. An operational model was proposed to describe and optimize acid gas removal process. It was applied to an existing MSW incineration plant, where acid gases are neutralized in a two-stage dry treatment system. This process is based on the injection of powdered calcium hydroxide and sodium bicarbonate in reactors followed by fabric filters. HCl and SO2 conversions were expressed as a function of reactants flow rates, calculating model parameters from literature and plant data. The implementation in a software for process simulation allowed the identification of optimal operating conditions, taking into account the reactant feed rates, the amount of solid products and the recycle of the sorbent. Alternative configurations of the reference plant were also assessed. The applicability of the operational model was extended developing also a fundamental approach to the issue. A predictive model was developed, describing mass transfer and kinetic phenomena governing the acid gas neutralization with solid sorbents. The rate controlling steps were identified through the reproduction of literature data, allowing the description of acid gas removal in the case study analyzed. A laboratory device was also designed and started up to assess the required model parameters.
Resumo:
In the last years the attentions on the energy efficiency on historical buildings grows, as different research project took place across Europe. The attention on combining, the need of the preservation of the buildings, their value and their characteristic, with the need of the reduction of energy consumption and the improvements of indoor comfort condition, stimulate the discussion of two points of view that are usually in contradiction, buildings engineer and Conservation Institution. The results are surprising because a common field is growing while remains the need of balancing the respective exigencies. From these experience results clear that many questions should be answered also from the building physicist regarding the correct assessment: on the energy consumption of this class of buildings, on the effectiveness of the measures that could be adopted, and much more. This thesis gives a contribution to answer to these questions developing a procedure to analyse the historic building. The procedure gives a guideline of the energy audit for the historical building considering the experimental activities to dial with the uncertainty of the estimation of the energy balance. It offers a procedure to simulate the energy balance of building with a validated dynamic model considering also a calibration procedure to increase the accuracy of the model. An approach of design of energy efficiency measures through an optimization that consider different aspect is also presented. All the process is applied to a real case study to give to the reader a practical understanding.
Resumo:
High Energy efficiency and high performance are the key regiments for Internet of Things (IoT) end-nodes. Exploiting cluster of multiple programmable processors has recently emerged as a suitable solution to address this challenge. However, one of the main bottlenecks for multi-core architectures is the instruction cache. While private caches fall into data replication and wasting area, fully shared caches lack scalability and form a bottleneck for the operating frequency. Hence we propose a hybrid solution where a larger shared cache (L1.5) is shared by multiple cores connected through a low-latency interconnect to small private caches (L1). However, it is still limited by large capacity miss with a small L1. Thus, we propose a sequential prefetch from L1 to L1.5 to improve the performance with little area overhead. Moreover, to cut the critical path for better timing, we optimized the core instruction fetch stage with non-blocking transfer by adopting a 4 x 32-bit ring buffer FIFO and adding a pipeline for the conditional branch. We present a detailed comparison of different instruction cache architectures' performance and energy efficiency recently proposed for Parallel Ultra-Low-Power clusters. On average, when executing a set of real-life IoT applications, our two-level cache improves the performance by up to 20% and loses 7% energy efficiency with respect to the private cache. Compared to a shared cache system, it improves performance by up to 17% and keeps the same energy efficiency. In the end, up to 20% timing (maximum frequency) improvement and software control enable the two-level instruction cache with prefetch adapt to various battery-powered usage cases to balance high performance and energy efficiency.
Resumo:
The relation between the intercepted light and orchard productivity was considered linear, although this dependence seems to be more subordinate to planting system rather than light intensity. At whole plant level not always the increase of irradiance determines productivity improvement. One of the reasons can be the plant intrinsic un-efficiency in using energy. Generally in full light only the 5 – 10% of the total incoming energy is allocated to net photosynthesis. Therefore preserving or improving this efficiency becomes pivotal for scientist and fruit growers. Even tough a conspicuous energy amount is reflected or transmitted, plants can not avoid to absorb photons in excess. The chlorophyll over-excitation promotes the reactive species production increasing the photoinhibition risks. The dangerous consequences of photoinhibition forced plants to evolve a complex and multilevel machine able to dissipate the energy excess quenching heat (Non Photochemical Quenching), moving electrons (water-water cycle , cyclic transport around PSI, glutathione-ascorbate cycle and photorespiration) and scavenging the generated reactive species. The price plants must pay for this equipment is the use of CO2 and reducing power with a consequent decrease of the photosynthetic efficiency, both because some photons are not used for carboxylation and an effective CO2 and reducing power loss occurs. Net photosynthesis increases with light until the saturation point, additional PPFD doesn’t improve carboxylation but it rises the efficiency of the alternative pathways in energy dissipation but also ROS production and photoinhibition risks. The wide photo-protective apparatus, although is not able to cope with the excessive incoming energy, therefore photodamage occurs. Each event increasing the photon pressure and/or decreasing the efficiency of the described photo-protective mechanisms (i.e. thermal stress, water and nutritional deficiency) can emphasize the photoinhibition. Likely in nature a small amount of not damaged photosystems is found because of the effective, efficient and energy consuming recovery system. Since the damaged PSII is quickly repaired with energy expense, it would be interesting to investigate how much PSII recovery costs to plant productivity. This PhD. dissertation purposes to improve the knowledge about the several strategies accomplished for managing the incoming energy and the light excess implication on photo-damage in peach. The thesis is organized in three scientific units. In the first section a new rapid, non-intrusive, whole tissue and universal technique for functional PSII determination was implemented and validated on different kinds of plants as C3 and C4 species, woody and herbaceous plants, wild type and Chlorophyll b-less mutant and monocot and dicot plants. In the second unit, using a “singular” experimental orchard named “Asymmetric orchard”, the relation between light environment and photosynthetic performance, water use and photoinhibition was investigated in peach at whole plant level, furthermore the effect of photon pressure variation on energy management was considered on single leaf. In the third section the quenching analysis method suggested by Kornyeyev and Hendrickson (2007) was validate on peach. Afterwards it was applied in the field where the influence of moderate light and water reduction on peach photosynthetic performances, water requirements, energy management and photoinhibition was studied. Using solar energy as fuel for life plant is intrinsically suicidal since the high constant photodamage risk. This dissertation would try to highlight the complex relation existing between plant, in particular peach, and light analysing the principal strategies plants developed to manage the incoming light for deriving the maximal benefits as possible minimizing the risks. In the first instance the new method proposed for functional PSII determination based on P700 redox kinetics seems to be a valid, non intrusive, universal and field-applicable technique, even because it is able to measure in deep the whole leaf tissue rather than the first leaf layers as fluorescence. Fluorescence Fv/Fm parameter gives a good estimate of functional PSII but only when data obtained by ad-axial and ab-axial leaf surface are averaged. In addition to this method the energy quenching analysis proposed by Kornyeyev and Hendrickson (2007), combined with the photosynthesis model proposed by von Caemmerer (2000) is a forceful tool to analyse and study, even in the field, the relation between plant and environmental factors such as water, temperature but first of all light. “Asymmetric” training system is a good way to study light energy, photosynthetic performance and water use relations in the field. At whole plant level net carboxylation increases with PPFD reaching a saturating point. Light excess rather than improve photosynthesis may emphasize water and thermal stress leading to stomatal limitation. Furthermore too much light does not promote net carboxylation improvement but PSII damage, in fact in the most light exposed plants about 50-60% of the total PSII is inactivated. At single leaf level, net carboxylation increases till saturation point (1000 – 1200 μmolm-2s-1) and light excess is dissipated by non photochemical quenching and non net carboxylative transports. The latter follows a quite similar pattern of Pn/PPFD curve reaching the saturation point at almost the same photon flux density. At middle-low irradiance NPQ seems to be lumen pH limited because the incoming photon pressure is not enough to generate the optimum lumen pH for violaxanthin de-epoxidase (VDE) full activation. Peach leaves try to cope with the light excess increasing the non net carboxylative transports. While PPFD rises the xanthophyll cycle is more and more activated and the rate of non net carboxylative transports is reduced. Some of these alternative transports, such as the water-water cycle, the cyclic transport around the PSI and the glutathione-ascorbate cycle are able to generate additional H+ in lumen in order to support the VDE activation when light can be limiting. Moreover the alternative transports seems to be involved as an important dissipative way when high temperature and sub-optimal conductance emphasize the photoinhibition risks. In peach, a moderate water and light reduction does not determine net carboxylation decrease but, diminishing the incoming light and the environmental evapo-transpiration request, stomatal conductance decreases, improving water use efficiency. Therefore lowering light intensity till not limiting levels, water could be saved not compromising net photosynthesis. The quenching analysis is able to partition absorbed energy in the several utilization, photoprotection and photo-oxidation pathways. When recovery is permitted only few PSII remained un-repaired, although more net PSII damage is recorded in plants placed in full light. Even in this experiment, in over saturating light the main dissipation pathway is the non photochemical quenching; at middle-low irradiance it seems to be pH limited and other transports, such as photorespiration and alternative transports, are used to support photoprotection and to contribute for creating the optimal trans-thylakoidal ΔpH for violaxanthin de-epoxidase. These alternative pathways become the main quenching mechanisms at very low light environment. Another aspect pointed out by this study is the role of NPQ as dissipative pathway when conductance becomes severely limiting. The evidence that in nature a small amount of damaged PSII is seen indicates the presence of an effective and efficient recovery mechanism that masks the real photodamage occurring during the day. At single leaf level, when repair is not allowed leaves in full light are two fold more photoinhibited than the shaded ones. Therefore light in excess of the photosynthetic optima does not promote net carboxylation but increases water loss and PSII damage. The more is photoinhibition the more must be the photosystems to be repaired and consequently the energy and dry matter to allocate in this essential activity. Since above the saturation point net photosynthesis is constant while photoinhibition increases it would be interesting to investigate how photodamage costs in terms of tree productivity. An other aspect of pivotal importance to be further widened is the combined influence of light and other environmental parameters, like water status, temperature and nutrition on peach light, water and phtosyntate management.
Resumo:
During the last decade advances in the field of sensor design and improved base materials have pushed the radiation hardness of the current silicon detector technology to impressive performance. It should allow operation of the tracking systems of the Large Hadron Collider (LHC) experiments at nominal luminosity (1034 cm-2s-1) for about 10 years. The current silicon detectors are unable to cope with such an environment. Silicon carbide (SiC), which has recently been recognized as potentially radiation hard, is now studied. In this work it was analyzed the effect of high energy neutron irradiation on 4H-SiC particle detectors. Schottky and junction particle detectors were irradiated with 1 MeV neutrons up to fluence of 1016 cm-2. It is well known that the degradation of the detectors with irradiation, independently of the structure used for their realization, is caused by lattice defects, like creation of point-like defect, dopant deactivation and dead layer formation and that a crucial aspect for the understanding of the defect kinetics at a microscopic level is the correct identification of the crystal defects in terms of their electrical activity. In order to clarify the defect kinetic it were carried out a thermal transient spectroscopy (DLTS and PICTS) analysis of different samples irradiated at increasing fluences. The defect evolution was correlated with the transport properties of the irradiated detector, always comparing with the un-irradiated one. The charge collection efficiency degradation of Schottky detectors induced by neutron irradiation was related to the increasing concentration of defects as function of the neutron fluence.
Resumo:
The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.