33 resultados para degenerazioni, retiniche, protesi, retinali, semiconduttori, organici

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blue mould caused by Penicillium expansum Link is one of the most destructive rot of pome fruit in all growing areas (Snowdon, 1990; Jones and Aldwinckle, 1991; Tonini,1996) In the past, Penicillium rot has been controlled by fungicide postharvest treatment mainly by thiabendazole (TBZ) and benomyl (Hardenburg and Spalding, 1972), but their intense use produced the appearance of resistant strains with a great reduction of their activity The aims of the present study were to characterize the isolates of Pencillium sp causing blue mold on pear in Italy by physiological and biochemical parameters. In particular differencing also the behavior of isolates to relationship with sensitivity or resistance to TBZ treatments. We have examined the early stage of infection in relation to enzyme activity, local modulation of pH, production of organic acids, and to secondary metabolism of pathogen. The results described here confirm that the majority of P. expansum isolates from pears packing houses are resistant to TBZ, Among the TBZ-resistant isolates scored in this work, different isolates (RR) showed higher percentage of conidial germination on TBZ-amended medium compared to non amended medium. This may indicate a stimulatory effect of TBZ on conidial germination. Therefore TBZ treatments are not only ineffective for controlling P. expansum, but they may also increase the severity of blue mould on fruits. In the absence of fungicide, isolates showed a significant difference for infection severity, R and RR isolates are characterized by higher pathogenic fitness on fruits, producing larger lesions than S isolates. These data are supported by the study with laboratory-induced resistant isolates, which shows the lack of correlation between TBZ resistance and osmotic sensitivity, and highlights the association between TBZ resistance and infection severity (Baraldi et al 2003). Enzymatic screening gave a positive reaction to esterase, urease, pectinase activity, in addition, the pathogen is able to synthesize a complex enzyme act to degrade the main components of the cell wall especially pectin and cellulose. Isolated sensitive and resistant are characterized by a good activity of pectinase, especially from poligactoronase, which, as already reported by several studies (D'hallewin et al, 2004; Prusky et al, 2004), are the basis of degradative process of cell wall. Also, although the measure was minor also highlighted some activities of cellulase, but even note in the production of this kind of cellulase and hemicellulase P. Expansum were not targeted, studies have found no other source of information in this regard. Twenty isolates of Penicillium expansum, were tested in vitro ad in vivo for acid production ability and pH drop. We have found that modulation of pH and the organic acids extrusion were influence to various parameter:  Initial pH: in general, the greatest reduction of pH was observed in isolates grown at pH 7, except for four isolates that maintained the pH of the medium close to 7, the others significantly decreased the pH, ranging from 5.5 to 4.1.. In extreme acid condition (pH 3,0) growth and modulation of pH is most lower respect optimal condition (pH 5,0). Also isolates R and RR have showed a greater adaptation to environmental condition more than isolates S.  Time: although the acidification continues for some days, PH modulation is strongest in early hours (48-72 hours)of inoculation process. Time also affects the quality of organic acids, for example in vitro results showed an initial abundant production of succinc acid, followed to important production of galacturoinc acid.  Substrates: there are many differences for the type of acids produced in vitro and in vivo. Results showed in vivo an abundant production of galacturonic, malic, and citric acids and some unknown organic acids in smaller concentrations. Secondary metabolite analysis revealed intra-specific differences, and patulin was found in all isolates, but most significant reduction was observed between in vitro and in vivo samples. There was no correlation between the concentration of patulin, and the percentage of infected fruits, but sample with a lower infection severity of rotten area than the others, showed a significantly lower mycotoxin concentration than samples with a higher lesion diameter of rotten area. Beyond of patulin was detected the presence of another secondary metabolite, penitrem A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'attività di ricerca descritta in questa tesi fornisce linee guida per la progettazione di arti protesici inferiori, con particolare riferimento alla progettazione di protesi a basso costo. La necessità di efficienti protesi a basso costo risulta infatti sentita nei Paesi in via di sviluppo ma anche dalle fasce meno abbienti dei paesi occidentali. Al fine di comprendere le strategie adottate dall'apparato locomotorio per muoversi con le protesi sono analizzati il cammino fisiologico, le protesi presenti sul mercato ed infine le modalità con cui le loro prestazioni sono valutate. Con il presente lavoro, dopo aver osservato la presenza di una scarsa strutturazione della metodologia di progettazione che riguarda specialmente il settore del basso costo, si propone una metodologia il più possibile oggettiva e ripetibile tesa ad individuare quali sono gli aspetti essenziali di una protesi per garantire al paziente una buona qualità di vita. Solo questi aspetti dovranno essere selezionati al fine di ottenere la massima semplificazione della protesi e ridurre il più possibile i costi. Per la simulazione delle attività di locomozione, in particolare del cammino, è stato elaborato un apposito modello spaziale del cammino. Il modello proposto ha 7 membri rigidi (corrispondenti a piedi, tibie, femori e bacino) e 24 gradi di libertà. Le articolazioni e l'appoggio dei piedi al suolo sono modellati con giunti sferici. La pianta del piede consente tre possibili punti di appoggio. I criteri di realizzazione delle simulazioni possono comprendere aspetti energetici, cinematici e dinamici considerati come obiettivo dall'apparato locomotorio. In questa tesi vengono trattati in particolare gli aspetti cinematici ed è mostrata un'applicazione della procedura nella quale vengono dapprima identificati i riferimenti fisiologici del cammino e quindi simulato il cammino in presenza di una menomazione al ginocchio (eliminazione della flessione in fase di appoggio). Viene quindi lasciato a sviluppi futuri il completamento della procedura e la sua implementazione in un codice di calcolo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’attività della tesi riguarda le protesi mioelettriche, gli arti protesici maggiormente diffusi, le quali sono descrivibili come arti robotici in cui i segmenti artificiali sono attuati da giunti elettromeccanici alimentati da batterie ricaricabili ed attivati mediante segnali elettromiografici (segnali elettrici generati dalla contrazione dei muscoli). Tali protesi di arto superiore attualmente disponibili in commercio potrebbero essere inadeguate per una riabilitazione soddisfacente di alcuni pazienti con una amputazione di alto livello che richiedono una elevata funzionalità nella vita quotidiana. In questo contesto si inserisce l’attività di ricerca del Centro Protesi INAIL di Budrio di Vigorso, Bologna, e dell’Università di Bologna i quali stanno sviluppando nuovi arti protesici con il progetto a lungo termine di rendere disponibili svariate soluzioni di protesi di arto superiore in grado di soddisfare la maggior parte delle richieste degli amputati. Lo scopo di questa tesi è l’introduzione di un nuovo rotatore omerale attivo da integrare alla protesi di arto superiore disponibile presso i nostri laboratori. Per ottenere questo risultato è stata utilizzata una procedura di progettazione già consolidata in attività precedenti per lo sviluppo di una protesi di spalla a due gradi di libertà. Differenti modelli cinematici sono stati studiati tramite analisi cinematiche per determinare l’incremento delle prestazioni a seguito dell’introduzione del nuovo rotatore omerale attivo. Sono state inoltre condotte analisi cinetostatiche per definire le specifiche tecniche di riferimento (in termini di carichi agenti sul rotatore omerale) e per guidare il dimensionamento della catena di trasmissione di potenza del nuovo dispositivo protesico. Ulteriori specifiche tecniche sono state considerate per garantire l’irreversibilità spontanea del moto sotto carichi esterni (quando i giunti attivi della protesi non sono alimentati), per salvaguardare l’incolumità del paziente in caso di caduta, per misurare la posizione angolare del rotatore omerale (in modo da implementare strategie di controllo in retroazione) e per limitare i consumi e la rumorosità del dispositivo. Uno studio di fattibilità ha permesso la selezione della architettura ottimale della catena di trasmissione di potenza per il nuovo rotatore omerale. I criteri di scelta sono stati principalmente la limitazione del peso e dell’ingombro del nuovo dispositivo protesico. Si è quindi proceduto con la progettazione di dettaglio alla quale è seguita la costruzione di un prototipo del nuovo rotatore omerale presso i nostri laboratori. La tesi tratta infine una attività preliminare di sperimentazione che ha permesso di fare considerazioni sulle prestazioni del prototipo ed osservazioni importanti per le successive attività di revisione ed ottimizzazione del progetto del rotatore omerale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sono stati studiati gli effetti tossici dell’esposizione cronica a cobalto e cromo. In passato, questa tossicità, che colpiva lavoratori esposti per ragioni occupazionali, è stata un problema molto sentito. Tuttavia, recenti pubblicazioni hanno descritto una specifica tossicità mediata da elevati livelli di cobalto e cromo, anche in pazienti portatori di protesi metalliche, quali gli impianti d’anca. Anche se sintomi clinici tra cui, cecità, sordità e neuropatia periferica, suggeriscono uno specifico neurotropismo, ancora poco è conosciuto delle basi neuropatologiche di questo processo ed oltretutto non ne è ancora stata apportata un’evidenza sperimentale. In questo progetto di ricerca, quindi, si è voluto approfondire il meccanismo patogenetico da cui scaturiscono tali sintomi neurologici, utilizzando come modello sperimentale il coniglio. Conigli New Zealand White sono stati trattati con dosi endovenose ripetute di cobalto e cromo, inoculati singolarmente od in associazione tra loro. Nessuna evidente alterazione clinica o patologica è stata associata alla somministrazione di solo cromo, nonostante gli elevati livelli in sangue e tessuti, mentre i trattati con cobalto-cromo o solo cobalto hanno mostrato segni clinici gravanti sul sistema vestibolo-cocleare; il cobalto, quindi, è stato identificato come il maggiore elemento scatenante neurotossicità. Inoltre all’esame istopatologico gli animali hanno mostrato severa deplezione delle cellule gangliari retiniche e cocleari, assieme a danno al nervo ottico e perdita di cellule sensitive capellute dell’orecchio. È risultato infine evidente che la gravità delle alterazioni è stata correlata al dosaggio ed al tempo di esposizione; dati questi che confermano, quindi, le precedenti osservazioni fatte su pazienti umani esposti a rilascio abnorme di cobalto e cromo da usura di protesi d’anca. È stato ipotizzato che il cobalto agisca sui mitocondri provocando l’incremento di produzione di specie reattive dell’ossigeno e il rilascio di fattori proapoptotici, causando sulle cellule neuronali un danno proporzionale al loro fabbisogno energetico e grado di mielinizzazione.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lo scopo di questo studio è stato quello di determinare se a lungo termine le concentrazioni sieriche di ioni nei pazienti con protesi di rivestimento d’anca metallo-metallo (MOM-HR, metal-on-metal hip resurfacing) fossero differenti da quelle valutate nei pazienti con protesi totale d’anca metallo-metallo e testa del diametro di 28 mm (MOM-THA, metal-on-metal total hip arthroplasty); inoltre è stato valutato se le concentrazioni ioniche fossero al di sopra dei valori di riferimento e se fosse possibile stabilire l’esistenza di una relazione tra sesso e concentrazioni di ioni con riferimento al tipo di impianto. Il gruppo MOM-HR era costituito da 25 pazienti mentre il gruppo MOM-THA era di 16 pazienti. Per poter ricavare i valori di riferimento sono stati reclutati 48 donatori sani. La misurazione delle concentrazioni degli ioni cobalto (Co), cromo (Cr), nickel (Ni) e molibdeno (Mo) è stata effettuata utilizzando la spettrofotometria ad assorbimento atomico su fornace di grafite. A parte il Ni, le concentrazioni di ioni nei pazienti con MOM-HR erano più elevate rispetto ai controlli. Il rilascio di ioni Cr e Co nei pazienti con MOM-HR è risultato superiore rispetto ai soggetti con MOM-THA. Da un’analisi basata sul sesso, è emerso che nelle femmine con MOM-HR i livelli di ioni Cr e Co sono risultati significativamente aumentati rispetto alle femmine con MOM-THA. Indipendentemente dal tipo di impianto, gli accoppiamenti metallo-metallo (MOM) producono concentrazioni di ioni metallici significativamente più alte a follow-up a lungo termine rispetto a quelle osservate nei soggetti sani. Un fattore che deve essere attentamente considerato nella scelta dell’impianto, e in particolar modo nei soggetti giovani, è il cospicuo rilascio di ioni Cr e Co nella popolazione femminile con MOM-HR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’attività di dottorato qui descritta ha riguardato inizialmente lo sviluppo di biosensori elettrochimici semplificati per la rilevazione di DNA e successivamente lo studio di dispositivi organici ad effetto di campo per la stimolazione e il rilevamento dell’attività bioelettrica di cellule neuronali. Il lavoro di ricerca riguardante il prima parte è stato focalizzato sulla fabbricazione e sulla caratterizzazione di un biosensore a due elettrodi per la rilevazione di DNA solubile , facilmente producibile a livello industriale. Tale sensore infatti, è in grado di leggere livelli diversi di correnti faradiche sulle superfici in oro degli elettrodi, a discrezione di un eventuale ibridizzazione del DNA da analizzare su di esse. I risultati ottenuti riguardo a questo biosensore sono :la paragonabilità dello stesso con i sensori standard a tre elettrodi basati sulla medesima metodica, la possibilità di effettuare due misure in parallelo di uno stesso campione o di 2 diversi campioni su di uno stesso di dispositivo e la buona applicabilità della chimica superficiale a base di tale biosensore a superfici create con tecnologie industriali. Successivamente a tali studi, mi sono focalizzato sull’utilizzo di dispositivi organici ad effetto campo (in particolare OTFT) per lo sviluppo di un biosensore capace di stimolare e registrare l’attività bioelettrica di cellule neuronali. Inizialmente sono state identificate le caratteristiche del materiale organico utilizzato e successivamente del dispositivo fabbricato pre e post esposizione all’ambiente fisiologico. Poi, sono stati effettuati esperimenti per osservare la capacità di stimolare e di leggere i segnali elettrogenici da parte dell’OTFT. I risultati ottenuti da tali studi sono che: il materiale organico ed il dispositivo mantengo le loro caratteristiche morfologiche e funzionali dopo l’esposizione per giorni all’ambiente fisiologico. Inoltre l’OFET in grado di stimolare il cambiamento delle tensioni di membrana cellulari e contemporaneamente di registrare tali variazioni e le eventuali risposte cellulari provocate da esse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’accoppiamento articolare in ceramica è sempre più utilizzato in chirurgia protesica dell’anca per le sue eccellenti proprietà tribologiche. Tuttavia la fragilità della ceramica è causa di fallimenti meccanici. Abbiamo quindi condotto una serie di studi al fine di individuare un metodo efficace di diagnosi precoce del fallimento della ceramica. Abbiamo analizzato delle componenti ceramiche espiantate e abbiamo trovato un pattern di usura pre-frattura che faceva supporre una dispersione di particelle di ceramica nello spazio articolare. Per la diagnosi precoce abbiamo validato una metodica basata sulla microanalisi del liquido sinoviale. Per validare la metodica abbiamo eseguito un agoaspirato in 12 protesi ben funzionanti (bianchi) e confrontato i risultati di 39 protesi con segni di rottura con quelli di 7 senza segni di rottura. Per individuare i pazienti a rischio rottura i dati demografici di 26 pazienti con ceramica rotta sono stati confrontati con 49 controlli comparabili in termini demografici, tipo di ceramica e tipo di protesi. Infine è stata condotta una revisione sistematica della letteratura sulla diagnosi della rottura della ceramica. Nell’aspirato la presenza di almeno 11 particelle ceramiche di dimensioni inferiori a 3 micron o di una maggiore di 3 micron per ogni campo di osservazione sono segno di rottura della ceramica. La metodica con agoaspirato ha 100% di sensibilità e 88 % di specificità nel predire rotture della ceramica. Nel gruppo delle ceramiche rotte è stato trovato un maggior numero di malposizionamenti della protesi rispetto ai controlli (p=0,001). Il rumore in protesi con ceramica dovrebbe sollevare il sospetto di fallimento ed indurre ad eseguire una TC e un agoaspirato. Dal confronto con la letteratura la nostra metodica risulta essere la più efficace.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerosi parassitoidi localizzano i propri ospiti sfruttando le miscele di composti volatili rilasciate dalle piante infestate, che sono segnali più facilmente reperibili nell’ambiente rispetto agli odori emessi dai soli fitofagi. Anche Diglyphus isaea (Walker), un ectoparassitoide paleartico impiegato nella lotta biologica contro vari fillominatori, localizza l’ospite Liriomyza trifolii (Burgess) (Diptera Agromyzidae) sfruttando gli odori emessi dal complesso pianta (Phaseolus vulgaris L.) – minatore (L. trifolii). L’obbiettivo di questa ricerca è stato di mettere a punto una procedura che consentisse di estrarre in vivo, da piante di fagiolo infestate da larve di L. trifolii, i composti volatili responsabili dell’attrazione del parassitoide D. isaea e permettesse di individuare i composti biologicamente attivi presenti nella miscela. A tal fine sono state messe a confronto due metodologie, ovvero la tecnica statica dell’SPME e quella dinamica dell’Air Entrainment, impiegate in ecologia chimica per identificare e quantificare i composti organici volatili da numerose matrici biologiche. Le miscele estratte dai campioni sono state sia analizzate al gascromatografo/spettrometro di massa, che saggiate all’olfattometro a Y. Alla luce dei risultati ottenuti, si può affermare che la tecnica dell’Air Entrainment si è rivelata più adatta al raggiungimento degli obbiettivi di questo studio. Grazie a questa metodologia infatti è stato possibile verificare l’attività biologica delle miscele estratte nei confronti di D. isaea e identificare i composti volatili imputabili, con buona probabilità, unicamente all’attività trofica del fillominatore. Si tratta principalmente di terpenoidi volatili, sostanze spesso indicate come importanti segnali utilizzati da predatori e parassitoidi per localizzare le proprie prede o i propri ospiti. Questi composti sono stati diluiti in etere e saggiati a tre diverse concentrazioni (1 ng; 10 ng; 100 ng) contro l’etere (controllo). L’analisi statistica delle differenze registrate nelle scelte definitive compiute da D. isaea, nel corso delle prove condotte con i composti puri (indolo; α-copaene; β-cariofillene; α-cariofillene; α-farnesene), ha messo in luce come questo parassitoide risulti attratto solo dall’α-cariofillene, mentre l’α-farnesene sembra avere nei confronti dell’eulofide un effetto repellente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premessa: nell’aprile 2006, l’American Heart Association ha approvato la nuova definizione e classificazione delle cardiomiopatie (B. J. Maron e coll. 2006), riconoscendole come un eterogeneo gruppo di malattie associate a disfunzione meccanica e/o elettrica riconducibili ad un ampia variabilità di cause. La distinzione tra le varie forme si basa non più sui processi etiopatogenetici che ne sono alla base, ma sulla modalità di presentazione clinica della malattia. Si distinguono così le forme primarie, a prevalente od esclusivo interessamento cardiaco, dalle forme secondarie in cui la cardiomiopatia rientra nell’ambito di un disordine sistemico dove sono evidenziabili anche disturbi extracardiaci. La nostra attenzione è, nel presente studio, focalizzata sull’analisi delle cardiomiopatie diagnosticate nei primi anni di vita in cui si registra una più alta incidenza di forme secondarie rispetto all’adulto, riservando un particolare riguardo verso quelle forme associate a disordini metabolici. Nello specifico, il nostro obiettivo è quello di sottolineare l’influenza di una diagnosi precoce sull’evoluzione della malattia. Materiali e metodi: abbiamo eseguito uno studio descrittivo in base ad un’analisi retrospettiva di tutti i pazienti giunti all’osservazione del Centro di Cardiologia e Cardiochirurgia Pediatrica e dell’ Età Evolutiva del Policlinico S. Orsola- Malpighi di Bologna, dal 1990 al 2006, con diagnosi di cardiomiopatia riscontrata nei primi due anni di vita. Complessivamente sono stati studiati 40 pazienti di cui 20 con cardiomiopatia ipertrofica, 18 con cardiomiopatia dilatativa e 2 con cardiomiopatia restrittiva con un’età media alla diagnosi di 4,5 mesi (range:0-24 mesi). Per i pazienti descritti a partire dal 2002, 23 in totale, sono state eseguite le seguenti indagini metaboliche: emogasanalisi, dosaggio della carnitina, metabolismo degli acidi grassi liberi (pre e post pasto), aminoacidemia quantitativa (pre e post pasto), acidi organici, mucopolisaccaridi ed oligosaccaridi urinari, acilcarnitine. Gli stessi pazienti sono stati inoltre sottoposti a prelievo bioptico di muscolo scheletrico per l’analisi ultrastrutturale, e per l’analisi dell’attività enzimatica della catena respiratoria mitocondriale. Nella stessa seduta veniva effettuata la biopsia cutanea per l’eventuale valutazione di deficit enzimatici nei fibroblasti. Risultati: l’età media alla diagnosi era di 132 giorni (range: 0-540 giorni) per le cardiomiopatie ipertrofiche, 90 giorni per le dilatative (range: 0-210 giorni) mentre le 2 bambine con cardiomiopatia restrittiva avevano 18 e 24 mesi al momento della diagnosi. Le indagini metaboliche eseguite sui 23 pazienti ci hanno permesso di individuare 5 bambini con malattia metabolica (di cui 2 deficit severi della catena respiratoria mitocondriale, 1 con insufficienza della β- ossidazione per alterazione delle acilcarnitine , 1 con sindrome di Barth e 1 con malattia di Pompe) e un caso di cardiomiopatia dilatativa associata a rachitismo carenziale. Di questi, 4 sono deceduti e uno è stato perduto al follow-up mentre la forma associata a rachitismo ha mostrato un netto miglioramento della funzionalità cardiaca dopo appropriata terapia con vitamina D e calcio. In tutti la malattia era stata diagnosticata entro l’anno di vita. Ciò concorda con gli studi documentati in letteratura che associano le malattie metaboliche ad un esordio precoce e ad una prognosi infausta. Da un punto di vista morfologico, un’evoluzione severa si associava alla forma dilatativa, ed in particolare a quella con aspetto non compaction del ventricolo sinistro, rispetto alla ipertrofica e, tra le ipertrofiche, alle forme con ostruzione all’efflusso ventricolare. Conclusioni: in accordo con quanto riscontrato in letteratura, abbiamo visto come le cardiomiopatie associate a forme secondarie, ed in particolare a disordini metabolici, sono di più frequente riscontro nella prima infanzia rispetto alle età successive e, per questo, l’esordio molto precoce di una cardiomiopatia deve essere sempre sospettata come l’espressione di una malattia sistemica. Abbiamo osservato, inoltre, una stretta correlazione tra l’età del bambino alla diagnosi e l’evoluzione della cardiomiopatia, registrando un peggioramento della prognosi in funzione della precocità della manifestazione clinica. In particolare la diagnosi eseguita in epoca prenatale si associava, nella maggior parte dei casi, ad un’evoluzione severa, comportandosi come una variabile indipendente da altri fattori prognostici. Riteniamo, quindi, opportuno sottoporre tutti i bambini con diagnosi di cardiomiopatia effettuata nei primi anni di vita ad uno screening metabolico completo volto ad individuare quelle forme per le quali sia possibile intraprendere una terapia specifica o, al contrario, escludere disordini che possano controindicare, o meno, l’esecuzione di un trapianto cardiaco qualora se ne presenti la necessità clinica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Negli ultimi anni, un crescente numero di studiosi ha focalizzato la propria attenzione sullo sviluppo di strategie che permettessero di caratterizzare le proprietà ADMET dei farmaci in via di sviluppo, il più rapidamente possibile. Questa tendenza origina dalla consapevolezza che circa la metà dei farmaci in via di sviluppo non viene commercializzato perché ha carenze nelle caratteristiche ADME, e che almeno la metà delle molecole che riescono ad essere commercializzate, hanno comunque qualche problema tossicologico o ADME [1]. Infatti, poco importa quanto una molecola possa essere attiva o specifica: perché possa diventare farmaco è necessario che venga ben assorbita, distribuita nell’organismo, metabolizzata non troppo rapidamente, ne troppo lentamente e completamente eliminata. Inoltre la molecola e i suoi metaboliti non dovrebbero essere tossici per l’organismo. Quindi è chiaro come una rapida determinazione dei parametri ADMET in fasi precoci dello sviluppo del farmaco, consenta di risparmiare tempo e denaro, permettendo di selezionare da subito i composti più promettenti e di lasciar perdere quelli con caratteristiche negative. Questa tesi si colloca in questo contesto, e mostra l’applicazione di una tecnica semplice, la biocromatografia, per caratterizzare rapidamente il legame di librerie di composti alla sieroalbumina umana (HSA). Inoltre mostra l’utilizzo di un’altra tecnica indipendente, il dicroismo circolare, che permette di studiare gli stessi sistemi farmaco-proteina, in soluzione, dando informazioni supplementari riguardo alla stereochimica del processo di legame. La HSA è la proteina più abbondante presente nel sangue. Questa proteina funziona da carrier per un gran numero di molecole, sia endogene, come ad esempio bilirubina, tiroxina, ormoni steroidei, acidi grassi, che xenobiotici. Inoltre aumenta la solubilità di molecole lipofile poco solubili in ambiente acquoso, come ad esempio i tassani. Il legame alla HSA è generalmente stereoselettivo e ad avviene a livello di siti di legame ad alta affinità. Inoltre è ben noto che la competizione tra farmaci o tra un farmaco e metaboliti endogeni, possa variare in maniera significativa la loro frazione libera, modificandone l’attività e la tossicità. Per queste sue proprietà la HSA può influenzare sia le proprietà farmacocinetiche che farmacodinamiche dei farmaci. Non è inusuale che un intero progetto di sviluppo di un farmaco possa venire abbandonato a causa di un’affinità troppo elevata alla HSA, o a un tempo di emivita troppo corto, o a una scarsa distribuzione dovuta ad un debole legame alla HSA. Dal punto di vista farmacocinetico, quindi, la HSA è la proteina di trasporto del plasma più importante. Un gran numero di pubblicazioni dimostra l’affidabilità della tecnica biocromatografica nello studio dei fenomeni di bioriconoscimento tra proteine e piccole molecole [2-6]. Il mio lavoro si è focalizzato principalmente sull’uso della biocromatografia come metodo per valutare le caratteristiche di legame di alcune serie di composti di interesse farmaceutico alla HSA, e sul miglioramento di tale tecnica. Per ottenere una miglior comprensione dei meccanismi di legame delle molecole studiate, gli stessi sistemi farmaco-HSA sono stati studiati anche con il dicroismo circolare (CD). Inizialmente, la HSA è stata immobilizzata su una colonna di silice epossidica impaccata 50 x 4.6 mm di diametro interno, utilizzando una procedura precedentemente riportata in letteratura [7], con alcune piccole modifiche. In breve, l’immobilizzazione è stata effettuata ponendo a ricircolo, attraverso una colonna precedentemente impaccata, una soluzione di HSA in determinate condizioni di pH e forza ionica. La colonna è stata quindi caratterizzata per quanto riguarda la quantità di proteina correttamente immobilizzata, attraverso l’analisi frontale di L-triptofano [8]. Di seguito, sono stati iniettati in colonna alcune soluzioni raceme di molecole note legare la HSA in maniera enantioselettiva, per controllare che la procedura di immobilizzazione non avesse modificato le proprietà di legame della proteina. Dopo essere stata caratterizzata, la colonna è stata utilizzata per determinare la percentuale di legame di una piccola serie di inibitori della proteasi HIV (IPs), e per individuarne il sito(i) di legame. La percentuale di legame è stata calcolata attraverso il fattore di capacità (k) dei campioni. Questo parametro in fase acquosa è stato estrapolato linearmente dal grafico log k contro la percentuale (v/v) di 1-propanolo presente nella fase mobile. Solamente per due dei cinque composti analizzati è stato possibile misurare direttamente il valore di k in assenza di solvente organico. Tutti gli IPs analizzati hanno mostrato un’elevata percentuale di legame alla HSA: in particolare, il valore per ritonavir, lopinavir e saquinavir è risultato maggiore del 95%. Questi risultati sono in accordo con dati presenti in letteratura, ottenuti attraverso il biosensore ottico [9]. Inoltre, questi risultati sono coerenti con la significativa riduzione di attività inibitoria di questi composti osservata in presenza di HSA. Questa riduzione sembra essere maggiore per i composti che legano maggiormente la proteina [10]. Successivamente sono stati eseguiti degli studi di competizione tramite cromatografia zonale. Questo metodo prevede di utilizzare una soluzione a concentrazione nota di un competitore come fase mobile, mentre piccole quantità di analita vengono iniettate nella colonna funzionalizzata con HSA. I competitori sono stati selezionati in base al loro legame selettivo ad uno dei principali siti di legame sulla proteina. In particolare, sono stati utilizzati salicilato di sodio, ibuprofene e valproato di sodio come marker dei siti I, II e sito della bilirubina, rispettivamente. Questi studi hanno mostrato un legame indipendente dei PIs ai siti I e II, mentre è stata osservata una debole anticooperatività per il sito della bilirubina. Lo stesso sistema farmaco-proteina è stato infine investigato in soluzione attraverso l’uso del dicroismo circolare. In particolare, è stato monitorata la variazione del segnale CD indotto di un complesso equimolare [HSA]/[bilirubina], a seguito dell’aggiunta di aliquote di ritonavir, scelto come rappresentante della serie. I risultati confermano la lieve anticooperatività per il sito della bilirubina osservato precedentemente negli studi biocromatografici. Successivamente, lo stesso protocollo descritto precedentemente è stato applicato a una colonna di silice epossidica monolitica 50 x 4.6 mm, per valutare l’affidabilità del supporto monolitico per applicazioni biocromatografiche. Il supporto monolitico monolitico ha mostrato buone caratteristiche cromatografiche in termini di contropressione, efficienza e stabilità, oltre che affidabilità nella determinazione dei parametri di legame alla HSA. Questa colonna è stata utilizzata per la determinazione della percentuale di legame alla HSA di una serie di poliamminochinoni sviluppati nell’ambito di una ricerca sulla malattia di Alzheimer. Tutti i composti hanno mostrato una percentuale di legame superiore al 95%. Inoltre, è stata osservata una correlazione tra percentuale di legame è caratteristiche della catena laterale (lunghezza e numero di gruppi amminici). Successivamente sono stati effettuati studi di competizione dei composti in esame tramite il dicroismo circolare in cui è stato evidenziato un effetto anticooperativo dei poliamminochinoni ai siti I e II, mentre rispetto al sito della bilirubina il legame si è dimostrato indipendente. Le conoscenze acquisite con il supporto monolitico precedentemente descritto, sono state applicate a una colonna di silice epossidica più corta (10 x 4.6 mm). Il metodo di determinazione della percentuale di legame utilizzato negli studi precedenti si basa su dati ottenuti con più esperimenti, quindi è necessario molto tempo prima di ottenere il dato finale. L’uso di una colonna più corta permette di ridurre i tempi di ritenzione degli analiti, per cui la determinazione della percentuale di legame alla HSA diventa molto più rapida. Si passa quindi da una analisi a medio rendimento a una analisi di screening ad alto rendimento (highthroughput- screening, HTS). Inoltre, la riduzione dei tempi di analisi, permette di evitare l’uso di soventi organici nella fase mobile. Dopo aver caratterizzato la colonna da 10 mm con lo stesso metodo precedentemente descritto per le altre colonne, sono stati iniettati una serie di standard variando il flusso della fase mobile, per valutare la possibilità di utilizzare flussi elevati. La colonna è stata quindi impiegata per stimare la percentuale di legame di una serie di molecole con differenti caratteristiche chimiche. Successivamente è stata valutata la possibilità di utilizzare una colonna così corta, anche per studi di competizione, ed è stata indagato il legame di una serie di composti al sito I. Infine è stata effettuata una valutazione della stabilità della colonna in seguito ad un uso estensivo. L’uso di supporti cromatografici funzionalizzati con albumine di diversa origine (ratto, cane, guinea pig, hamster, topo, coniglio), può essere proposto come applicazione futura di queste colonne HTS. Infatti, la possibilità di ottenere informazioni del legame dei farmaci in via di sviluppo alle diverse albumine, permetterebbe un migliore paragone tra i dati ottenuti tramite esperimenti in vitro e i dati ottenuti con esperimenti sull’animale, facilitando la successiva estrapolazione all’uomo, con la velocità di un metodo HTS. Inoltre, verrebbe ridotto anche il numero di animali utilizzati nelle sperimentazioni. Alcuni lavori presenti in letteratura dimostrano l’affidabilita di colonne funzionalizzate con albumine di diversa origine [11-13]: l’utilizzo di colonne più corte potrebbe aumentarne le applicazioni.