12 resultados para Sacro Monte

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fronte della frammentarietà e della confusione semantica della città contemporanea, la ricerca sui ‘Luoghi di identità e spazi del sacro nella città europea contemporanea’ ha inteso affrontare il tema della morfologia urbana in termini di significato. La focalizzazione sui temi dell’identità e del sacro nella città odierna è stata intesa quale modalità per tentare di andare alla radice dell’irrisolto problema di mancanza di senso che affligge la compagine urbana contemporanea e per cercare di individuare le cause e, quindi, le possibili azioni necessarie a riportare il costruito nell’ambito della relazione significante. Il campo di indagine è quello delle aree periferiche europee, ma la ricerca si muove da considerazioni di ordine generale relativamente alle reti di relazioni che l’essere umano instaura con il mondo circostante. Il lavoro sviluppa un primo inquadramento del tema di carattere generale, con un riferimento sistematico alla letteratura scientifica, individuando attraverso un sintetico excursus storico, i principi fondamentali della costruzione dell’immagine spaziale e del suo evolversi nel tempo. Su questa base i tre concetti di ‘centralità’, ‘identità’ e ‘sacro’, sono intesi come i cardini del discorso circa gli ambiti di significato e, sulla base di studi di alcune esperienze europee ritenute particolarmente esemplificative, la trattazione di questi tre temi arriva a proporre alcune considerazioni in merito alle caratteristiche che il contesto urbano deve avere per manifestarsi come luogo di costruzione di una identità personale e comunitaria. Nella consapevolezza che l’ampiezza dei temi considerati non ne consente una trattazione esaustiva, le considerazioni fatte sono da intendersi quali spunti di riflessione a riguardo dei metodi e delle modalità di relazione che sono ritenute necessarie per la costruzione di spazi di riferimento orientativo, identitario e socializzante.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lo scavo della chiesa di Santa MAria Maggiore ha permesso di acquisire nuove importanti informazioni sulla storia della città di Trento, sulla città tardo antica e sul processo di cristianizzazione. Il primo impianto ecclesiastico, datato a dopo la metà del V d. C. secolo, sorge su un precedente impianto termale realizzato intorno al II secolo d. C. ed appare caratterizzato da un forte carattere monumentale. La chiesa, a tre navate, presentava un presbiterio rialzato decorato in una prima fase da un opus sectile poi sostituito nel VI secolo da un mosaico policromo. Sono state rinvenute inoltre, parti consistenti della decorazione architettonica di fine VIII secolo pertinente questo stesso impianto che non subirà importanti modifiche fino alla realizzazione del successivo edificio di culto medievale, meno esteso e dai caratteri decisamente meno monumentali, caratterizzato dalla presenza di un esteso campo cimiteriale rinvenuto a nord della chiesa. A questo impianto ne succede un terzo, probabilmente a due navate, e dalla ricca decorazione pittorica demolito in età tardo rinascimentale per la realizzazione della chiesa attuale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study a new, fully non-linear, approach to Local Earthquake Tomography is presented. Local Earthquakes Tomography (LET) is a non-linear inversion problem that allows the joint determination of earthquakes parameters and velocity structure from arrival times of waves generated by local sources. Since the early developments of seismic tomography several inversion methods have been developed to solve this problem in a linearized way. In the framework of Monte Carlo sampling, we developed a new code based on the Reversible Jump Markov Chain Monte Carlo sampling method (Rj-McMc). It is a trans-dimensional approach in which the number of unknowns, and thus the model parameterization, is treated as one of the unknowns. I show that our new code allows overcoming major limitations of linearized tomography, opening a new perspective in seismic imaging. Synthetic tests demonstrate that our algorithm is able to produce a robust and reliable tomography without the need to make subjective a-priori assumptions about starting models and parameterization. Moreover it provides a more accurate estimate of uncertainties about the model parameters. Therefore, it is very suitable for investigating the velocity structure in regions that lack of accurate a-priori information. Synthetic tests also reveal that the lack of any regularization constraints allows extracting more information from the observed data and that the velocity structure can be detected also in regions where the density of rays is low and standard linearized codes fails. I also present high-resolution Vp and Vp/Vs models in two widespread investigated regions: the Parkfield segment of the San Andreas Fault (California, USA) and the area around the Alto Tiberina fault (Umbria-Marche, Italy). In both the cases, the models obtained with our code show a substantial improvement in the data fit, if compared with the models obtained from the same data set with the linearized inversion codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The carbonate outcrops of the anticline of Monte Conero (Italy) were studied in order to characterize the geometry of the fractures and to establish their influence on the petrophysical properties (hydraulic conductivity) and on the vulnerability to pollution. The outcrops form an analog for a fractured aquifer and belong to the Maiolica Fm. and the Scaglia Rossa Fm. The geometrical properties of fractures such as orientation, length, spacing and aperture were collected and statistically analyzed. Five types of mechanical fractures were observed: veins, joints, stylolites, breccias and faults. The types of fractures are arranged in different sets and geometric assemblages which form fracture networks. In addition, the fractures were analyzed at the microscale using thin sections. The fracture age-relationships resulted similar to those observed at the outcrop scale, indicating that at least three geological episodes have occurred in Monte Conero. A conceptual model for fault development was based on the observations of veins and stylolites. The fracture sets were modelled by the code FracSim3D to generate fracture network models. The permeability of a breccia zone was estimated at microscale by and point counting and binary image methods, whereas at the outcrop scale with Oda’s method. Microstructure analysis revealed that only faults and breccias are potential pathways for fluid flow since all veins observed are filled with calcite. According this, three scenarios were designed to asses the vulnerability to pollution of the analogue aquifer: the first scenario considers the Monte Conero without fractures, second scenario with all observed systematic fractures and the third scenario with open veins, joints and faults/breccias. The fractures influence the carbonate aquifer by increasing its porosity and hydraulic conductivity. The vulnerability to pollution depends also on the presence of karst zones, detric zones and the material of the vadose zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the scientific achievement of the last decades in the astrophysical and cosmological fields, the majority of the Universe energy content is still unknown. A potential solution to the “missing mass problem” is the existence of dark matter in the form of WIMPs. Due to the very small cross section for WIMP-nuleon interactions, the number of expected events is very limited (about 1 ev/tonne/year), thus requiring detectors with large target mass and low background level. The aim of the XENON1T experiment, the first tonne-scale LXe based detector, is to be sensitive to WIMP-nucleon cross section as low as 10^-47 cm^2. To investigate the possibility of such a detector to reach its goal, Monte Carlo simulations are mandatory to estimate the background. To this aim, the GEANT4 toolkit has been used to implement the detector geometry and to simulate the decays from the various background sources: electromagnetic and nuclear. From the analysis of the simulations, the level of background has been found totally acceptable for the experiment purposes: about 1 background event in a 2 tonne-years exposure. Indeed, using the Maximum Gap method, the XENON1T sensitivity has been evaluated and the minimum for the WIMP-nucleon cross sections has been found at 1.87 x 10^-47 cm^2, at 90% CL, for a WIMP mass of 45 GeV/c^2. The results have been independently cross checked by using the Likelihood Ratio method that confirmed such results with an agreement within less than a factor two. Such a result is completely acceptable considering the intrinsic differences between the two statistical methods. Thus, in the PhD thesis it has been proven that the XENON1T detector will be able to reach the designed sensitivity, thus lowering the limits on the WIMP-nucleon cross section by about 2 orders of magnitude with respect to the current experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the well-known MC code FLUKA was used to simulate the GE PETrace cyclotron (16.5 MeV) installed at “S. Orsola-Malpighi” University Hospital (Bologna, IT) and routinely used in the production of positron emitting radionuclides. Simulations yielded estimates of various quantities of interest, including: the effective dose distribution around the equipment; the effective number of neutron produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of 41Ar, the assessment of the saturation yield of radionuclides used in nuclear medicine. The simulations were validated against experimental measurements in terms of physical and transport parameters to be used at the energy range of interest in the medical field. The validated model was also extensively used in several practical applications uncluding the direct cyclotron production of non-standard radionuclides such as 99mTc, the production of medical radionuclides at TRIUMF (Vancouver, CA) TR13 cyclotron (13 MeV), the complete design of the new PET facility of “Sacro Cuore – Don Calabria” Hospital (Negrar, IT), including the ACSI TR19 (19 MeV) cyclotron, the dose field around the energy selection system (degrader) of a proton therapy cyclotron, the design of plug-doors for a new cyclotron facility, in which a 70 MeV cyclotron will be installed, and the partial decommissioning of a PET facility, including the replacement of a Scanditronix MC17 cyclotron with a new TR19 cyclotron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il paesaggio sacro dell'Epiro al di fuori dei centri di fondazione coloniale si caratterizza per una grande uniformità, determinata dall'esclusiva adozione delle forme templari non periptere. La ricerca si concentra sugli aspetti propriamente architettonici (planimetrici, tecnico-costruttivi, decorativi e formali) e sulle articolazioni funzionali dell'edilizia di culto regionale, troppo spesso trascurati nella storia degli studi a vantaggio di altre dimensioni dello spazio santuariale come quella religiosa o politico-istituzionale.