Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Leukemias, recent developments have demonstrated that the Hedgehog pathway plays a key-role in the peculiar ability of self renewal of leukemia stem cells. The aim of this research activity was to investigate, through a first in man, Phase I, open label, clinical trial, the role and the impact, mainly in terms of safety profile, adverse events and pharmacokinetics, of a Sonic Hedgehog inhibitor compound on a population of heavely pretreated patients affected by AML, CML, MF, or MDS, resistant or refractory to standard chemotherapy. Thirty-five patients have been enrolled. The drug was administered orally, in 28 days cycles, without rest periods. The compound showed a good safety profile. The half life was of 17-35 hours, justifying the daily administration. Significant signs of activity, in terms of reduction of bone marrow blast cell amount were seen in most of the patients enrolled. Interestingly, correlative biological studies demonstrated that, comparing the gene expression profyiling signature of separated CD34+ cells before and after one cycle of treatment, the most variably expressed genes were involved in the Hh pathway. Moreover, we observed that many genes involved in MDR (multidrug resistance)were significantly down regulated after treatment. These data might lead to future clinical trials based on combinatory approaches, including, for instance, Hh inhibitors and conventional chemotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The next generation of vaccine adjuvant are represented by a wide ranging set of molecules called Toll like agonists (TLR’s). Although many of these molecules are complex structures extracted from microorganisms, small molecule TLR agonists have also been identified. However, delivery systems have not been optimized to allow their effective delivery in conjunction with antigens. Here we describe a novel approach in which a small molecule TLR agonist has been conjugated directly to antigens to ensure effective co delivery. We describe the conjugation of a relevant protein, a recombinant protective antigen from S.pneumoniae (RrgB), which is linked to a TLR7 agonist. Following thorough characterization to ensure there was no aggregation, the conjugate was evaluated in a murine infection model. Results showed that the conjugate extended animals’ survival after lethal challenge with S.pneumoniae. Comparable results were obtained with a 10 fold lower dose than that of the native unconjugated antigen. Notably, the animals immunized with the same dose of unconjugated TLR7 agonist and antigen showed no adjuvant effect. The increased immunogenicity was likely a consequence of the co-localization of TLR7 agonist and antigen by chemical binding and is was more effective than simple co-administration. Likely, this approach can be adopted to reduce the dose of antigen required to induce protective immunity, and potentially increase the safety of a broad variety of vaccine candidates

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Scopo: L’obiettivo del presente programma di studio è stato quello di identificare e validare nuovi possibili bersagli terapeutici per l’osteosarcoma (OS) partendo dall’analisi del chinoma umano. Risultati: L’analisi del profilo di espressione genica ottenuta su 21 campioni clinici di OS ad alto grado di malignità ha permesso di selezionare le seguenti chinasi di possibile rilevanza biologica per l’OS: AURK-A, AURK-B, CDK2, PIK3CA, PLK-1. Le chinasi selezionate sono state validate tramite RNA interference. Successivamente è stata valutata l’efficacia dei relativi inibitori specifici: VX-680 e ZM-447439 inibitori delle Aurora-chinasi, Roscovitina di CDK2 e NMS1 di PLK-1, già inclusi in studi clinici. In termini d’inibizione della crescita cellulare le linee sono risultate maggiomente sensibili ai farmaci VX-680 e NMS1. E’ stata osservata una minor sensibilità ai farmaci VX-680, ZM447439 e NMS1 nelle linee doxorubicina(DX)-resistenti (caratterizzate da elevati livelli di espressione di ABCB1), indicando questi farmaci come potenziali substrati di ABCB1. La Roscovitina, nonostante i valori di IC50 elevati, non sembrerebbe substrato di ABCB1. La validazione preclinica di VX-680 e ZM447439 è stata completata. La forte inibizione della crescita è causata da endoreduplicazione per mancata citodieresi con conseguente formazione di una popolazione iperploide e apoptosi. Inoltre, VX-680 inibisce la motilità e la capacità di formare colonie. Esperimenti di associazione farmacologica mostrano che VX-680 interagisce positivamente con tutti i chemioterapici convenzionali impiegati nel trattamento dell’OS. NMS-1 produce interazioni positive con la DX in linee cellulari DX-resistenti, probabilmente grazie all’effetto revertante esercitato su ABCB1. La Roscovitina produce interazioni positive con CDDP e DX nelle varianti resistenti, effetto probbilmente dovuto al ruolo di CDK2 nei meccanismi di riparo del DNA. Conclusioni: L’analisi in vitro dell’attività degli inibitori ha permesso di identificare VX-680 come nuovo farmaco di potenziale interesse clinico, soprattutto in virtù delle sue interazioni sinergiche con i chemioterapici di uso convenzionale nel trattamento dell’osteosarcoma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite several clinical tests that have been developed to qualitatively describe complex motor tasks by functional testing, these methods often depend on clinicians' interpretation, experience and training, which make the assessment results inconsistent, without the precision required to objectively assess the effect of the rehabilitative intervention. A more detailed characterization is required to fully capture the various aspects of motor control and performance during complex movements of lower and upper limbs. The need for cost-effective and clinically applicable instrumented tests would enable quantitative assessment of performance on a subject-specific basis, overcoming the limitations due to the lack of objectiveness related to individual judgment, and possibly disclosing subtle alterations that are not clearly visible to the observer. Postural motion measurements at additional locations, such as lower and upper limbs and trunk, may be necessary in order to obtain information about the inter-segmental coordination during different functional tests involved in clinical practice. With these considerations in mind, this Thesis aims: i) to suggest a novel quantitative assessment tool for the kinematics and dynamics evaluation of a multi-link kinematic chain during several functional motor tasks (i.e. squat, sit-to-stand, postural sway), using one single-axis accelerometer per segment, ii) to present a novel quantitative technique for the upper limb joint kinematics estimation, considering a 3-link kinematic chain during the Fugl-Meyer Motor Assessment and using one inertial measurement unit per segment. The suggested methods could have several positive feedbacks from clinical practice. The use of objective biomechanical measurements, provided by inertial sensor-based technique, may help clinicians to: i) objectively track changes in motor ability, ii) provide timely feedback about the effectiveness of administered rehabilitation interventions, iii) enable intervention strategies to be modified or changed if found to be ineffective, and iv) speed up the experimental sessions when several subjects are asked to perform different functional tests.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Advances in biomedical signal acquisition systems for motion analysis have led to lowcost and ubiquitous wearable sensors which can be used to record movement data in different settings. This implies the potential availability of large amounts of quantitative data. It is then crucial to identify and to extract the information of clinical relevance from the large amount of available data. This quantitative and objective information can be an important aid for clinical decision making. Data mining is the process of discovering such information in databases through data processing, selection of informative data, and identification of relevant patterns. The databases considered in this thesis store motion data from wearable sensors (specifically accelerometers) and clinical information (clinical data, scores, tests). The main goal of this thesis is to develop data mining tools which can provide quantitative information to the clinician in the field of movement disorders. This thesis will focus on motor impairment in Parkinson's disease (PD). Different databases related to Parkinson subjects in different stages of the disease were considered for this thesis. Each database is characterized by the data recorded during a specific motor task performed by different groups of subjects. The data mining techniques that were used in this thesis are feature selection (a technique which was used to find relevant information and to discard useless or redundant data), classification, clustering, and regression. The aims were to identify high risk subjects for PD, characterize the differences between early PD subjects and healthy ones, characterize PD subtypes and automatically assess the severity of symptoms in the home setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is an urgent need to improve the performance of urine cytology for the diagnosis of bladder cancer. In preliminary studies, telomerase activity evaluated by telomeric repeat amplification protocol (TRAP) assay and chromosomal aneuploidy detected by fluorescence in situ hybridization (FISH) in the diagnosis of bladder cancer have produced important results. Urine cell-free (UCF) DNA has also been proposed as a potential marker for early bladder cancer diagnosis. In the first study the diagnostic performance of TRAP assay and FISH analysis was assessed, while the second study evaluated the potential role of UCF DNA integrity in early bladder cancer diagnosis. In the first cross-sectional study, 289 consecutive patients who presented with urinary symptoms underwent cystoscopy and cytology evaluation. In the second study, UCF DNA was isolated from 51 bladder cancer patients, 46 symptomatic patients, and 32 healthy volunteers. c-Myc, BCAS1 and HER2 gene sequences longer than 250 bp were quantified by real time PCR to verify UCF DNA integrity. In the first study, sensitivity and specificity were 0.39 and 0.83, respectively, for cytology; 0.66 and 0.72 for TRAP; 0.78 and 0.60 for the cytology and TRAP combination; 0.78 and 0.78 for the cytology, TRAP and FISH combination; and 0.65 and 0.93 for the TRAP and FISH combination. In the second study, at the best cutoff of 0.1 ng/µl, UCF DNA integrity analysis showed a sensitivity of 0.73 and a specificity of 0.84 in healthy individuals and 0.83 in symptomatic patients. The preliminary results suggest that these biomarkers could potentially be used for the early diagnosis of bladder cancer, especially in high-risk populations (e.g, symptomatic individuals exposed to occupational risk) who may benefit from the use of noninvasive diagnostic tests in terms of cost-benefit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nella presente tesi indaghiamo la potenzialità di LCM e Reverse Phase Protein microarray negli studi clinici. Si analizza la possibilità di creare una bio banca con line cellular primarie, al fine di conseguire drug test di sensibilità prima di decidere il trattamento da somministrare ai singoli pazienti. Sono stati ottenuti profili proteomici da biopsie pre e post terapia. I risultati dimostrano che questa piattaforma mostra il meccanismo di resistenza acquisito durante la terapia biologica. Questo ci ha portato ad analizzare una possibile stratificazione per pazienti con mCRC . I dati hanno rivelato distinti pathway di attivazione tra metastasi resecabile e non resecabili. I risultati mostrano inoltre due potenziali bersagli farmacologici. Ma la valutazione dell'intero tumore tramite singole biopsie sembra essere un problema a causa dell’eterogeneità intratumorale a livello genomico. Abbiamo indagato questo problema a livello dell'architettura del segnale in campioni di mCRC e ccRCC . I risultati indicano una somiglianza complessiva nei profili proteomici all'interno dello stesso tumore. Considerando che una singola biopsia è rappresentativa di un intera lesione , abbiamo studiato la possibilità di creare linee di cellule primarie, per valutare il profilo molecolare di ogni paziente. Fino ad oggi non c'era un protocollo per creare linee cellulari immortalizzate senza alcuna variazione genetica . abbiamo cosiderato, però, l'approccio innovativo delle CRCs. Ad oggi , non è ancora chiaro se tali cellule mimino il profilo dei tessuti oppure I passaggi in vitro modifichino i loro pathways . Sulla base di un modello di topo , i nostri dati mostrano un profilo di proteomica simile tra le linee di cellule e tessuti di topo LCM. In conclusione, i nostri dati dimostrano l'utilità della piattaforma LCM / RPPA nella sperimentazione clinica e la possibilità di creare una bio - banca di linee cellulari primarie, per migliorare la decisione del trattamento.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the first part of the research activity was to develop an aerobic cometabolic process in packed bed reactors (PBR) to treat real groundwater contaminated by trichloroethylene (TCE) and 1,1,2,2-tetrachloroethane (TeCA). In an initial screening conducted in batch bioreactors, different groundwater samples from 5 wells of the contaminated site were fed with 5 growth substrates. The work led to the selection of butane as the best growth substrate, and to the development and characterization from the site’s indigenous biomass of a suspended-cell consortium capable to degrade TCE with a 90 % mineralization of the organic chlorine. A kinetic study conducted in batch and continuous flow PBRs and led to the identification of the best carrier. A kinetic study of butane and TCE biodegradation indicated that the attached-cell consortium is characterized by a lower TCE specific degredation rates and by a lower level of mutual butane-TCE inhibition. A 31 L bioreactor was designed and set up for upscaling the experiment. The second part of the research focused on the biodegradation of 4 polymers, with and with-out chemical pre-treatments: linear low density polyethylene (LLDPE), polyethylene (PP), polystyrene (PS) and polyvinyl chloride (PVC). Initially, the 4 polymers were subjected to different chemical pre-treatments: ozonation and UV/ozonation, in gaseous and aqueous phase. It was found that, for LLDPE and PP, the coupling UV and ozone in gas phase is the most effective way to oxidize the polymers and to generate carbonyl groups on the polymer surface. In further tests, the effect of chemical pretreatment on polyner biodegrability was studied. Gas-phase ozonated and virgin polymers were incubated aerobically with: (a) a pure strain, (b) a mixed culture of bacteria; and (c) a fungal culture, together with saccharose as a co-substrate.