12 resultados para Minimally Invasive Surgical Procedures. Periodontics

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Micro-opto-mechanical systems (MOMS) based technology for the fabrication of ultrasonic probes on optical fiber is presented. Thanks to the high miniaturization level reached, the realization of an ultrasonic system constituted by ultrasonic generating and detecting elements, suitable for minimally invasive applications or Non Destructive Evaluation (NDE) of materials at high resolution, is demonstrated. The ultrasonic generation is realized by irradiating a highly absorbing carbon film patterned on silicon micromachined structures with a nanosecond pulsed laser source, generating a mechanical shock wave due to the thermal expansion of the film induced by optical energy conversion into heat. The short duration of the pulsed laser, together with an appropriate emitter design, assure high frequency and wide band ultrasonic generation. The acoustic detection is also realized on a MOMS device using an interferometric receiver, fabricated with a Fabry-Perot optical cavity realized by means of a patterned SU-8 and two Al metallization levels. In order to detect the ultrasonic waves, the cavity is interrogated by a laser beam measuring the reflected power with a photodiode. Various issues related to the design and fabrication of these acoustic probes are investigated in this thesis. First, theoretical models are developed to characterize the opto-acoustic behavior of the devices and estimate their expected acoustic performances. Tests structures are realized to derive the relevant physical parameters of the materials constituting the MOMS devices and determine the conditions theoretically assuring the best acoustic emission and detection performances. Moreover, by exploiting the models and the theoretical results, prototypes of acoustic probes are designed and their fabrication process developed by means of an extended experimental activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Articular cartilage lesions, with their inherent limited healing potential, are hard to treat and remain a challenging problem for orthopedic surgeons. Despite the development of several treatment strategies, the real potential of each procedure in terms of clinical benefit and effects on the joint degeneration processes is not clear. Aim of this PhD project was to evaluate the results, both in terms of clinical and imaging improvement, of new promising procedures developed to address the challenging cartilage pathology. Several studies have been followed in parallel and completed over the 3-year PhD, and are reported in detail in the following pages. In particular, the studies have been focused on the evaluation of the treatment indications of a scaffold based autologous chondrocyte implantation procedure, documenting its results for the classic indication of focal traumatic lesions, as well as its use for the treatment of more challenging patients, older, with degenerative lesions, or even as salvage procedure for more advanced stages of articular degeneration. The second field of study involved the analysis of the results obtained treating lesions of the articular surface with a new biomimetic osteochondral scaffold, which showed promise for the treatment of defects where the entire osteochondral unit is involved. Finally, a new minimally invasive procedure based on the use of growth factors derived from autologous platelets has been explored, showing results and underlining indicatios for the treatment of cartilage lesions and different stages of joint degeneration. These studies shed some light on the potential of the evaluated procedures, underlining good results as well as limits, they give some indications on the most appropriate candidates for their application, and document the current knowledge on cartilage treatment procedures suggesting the limitations that need to be addressed by future studies to improve the management of cartilage lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oggetto della tesi e' l'approfondimento su tecniche e metodiche di preservazione del polmone isolato per lo studio ecografico. E' discussa l'appropriatezza sull'uso degli ultrasuoni in corso di chirurgia mini invasiva polmonare, obiettivo di una ricerca sperimentale. Il razionale dello studio si fonda sull'indicazione all'exeresi chirurgica di noduli polmonari di diametro inferiore al centometro, ovvero di diametro superiore ma localizzati in aree centrali del polmone. Queste lesioni sono sempre piu' frequentente diagnosticate per mezzo di avanzate tecniche di imaging. L'atto chirurgico ha scopo terapeutico quando sia stata posta la diagnosi di neoplasia maligna, diagnostico-terapeutico quando non sia ancora ottenuta la tipizzazione istologica della lesione. La tecnica toracoscopica offre numerosi vantaggi rispetto alle tecniche chirurgiche tradizionali ma presenta il grave limite di non permettere la palpazione diretta del tessuto polmonare e la localizzazione della formazione tumorale quando essa non sia visibile macroscopicamente. Gli ultrasuoni sono stati utilizzati con successo per indirizzare la localizzazione del nodulo polmonare. Scopo dello studio sperimentale e' quello di confrontare tecniche diverse di preservazione del polmone isolato in un modello animale, comparando catatteristiche e prestazioni di sonde ecografiche differenti per tipologia. Del tutto recentemente, in ambito trapiantologico, sono state proposte tecniche di preservazione organica utili ai fini di uno studio anatomico sperimentale particolareggiato (EVLP) e moderna e' da considerarsi la concezione di mezzi tecnici specifici per la localizzazione di bersagli intrapolmonari. La tecnica clinica applicata allo studio del particolare ecografico, nel modello animale, ha reso comprensibile e meglio definito il ruolo delle sonde ecografiche nell'individuazione di forme tumorali suscettibili di exeresi definitiva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nel corso degli anni diverse sono le tecniche proposte per il trattamento delle lesioni osteocondrali, da quelle mini-invasive con stimolazione midollare fino a quelle più aggressive basate sul trapianto di tessuti autologhi o eterologhi. Tutti questi metodi hanno comunque dei difetti ed è questo il motivo per cui il trattamento delle lesioni osteocondrali rappresenta tuttora una sfida per il chirurgo ortopedico, in considerazione dell’alta specializzazione e del basso potere di guarigione del tessuto cartilagineo. Buoni risultati sono stati ottenuti con innesti bioingegnerizzati o matrici polimeriche impiantati nei siti danneggiati. La quantità di scaffolds in uso per la riparazione condrale ed osteocondrale è molto ampia; essi differiscono non solo per il tipo di materiali usati per la loro realizzazione, ma anche per la presenza di promotori di una o più linee cellulari , su base condrogenica o osteogenica. Quando ci si approccia ad una lesione condrale di grandi dimensioni, l’osso sub-condrale è anch’esso coinvolto e necessita di trattamento per ottenere il corretto ripristino degli strati articolari più superficiali. La scelta più giusta sembra essere un innesto osteocondrale bioingegnerizzato, pronto per l’uso ed immediatamente disponibile, che consenta di effettuare il trattamento in un unico tempo chirurgico. Sulla base di questo razionale, dopo uno studio preclinico animale e previa autorizzazione del comitato etico locale, abbiamo condotto uno studio clinico clinico pilota utilizzando un nuovo innesto biomimetico nanostrutturato per il trattamento di lesioni condrali ed osteocondrali del ginocchio; la sua sicurezza e maneggevolezza, così come la facile riproducibilità della tecnica chirurgica ed i risultati clinici ottenuti sono stati valutati nel tempo a 6, 12, 24, 36 e 48 mesi dall’impianto in modo da testare il suo potenziale intrinseco senza l’aggiunta di alcuna linea cellulare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La chirurgia con ultrasuoni focalizzati guidati da MRI (MR-g-FUS) è un trattamento di minima invasività, guidato dal più sofisticato strumento di imaging a disposizione, che utilizza a scopo diagnostico e terapeutico forme di energia non ionizzante. Le sue caratteristiche portano a pensare un suo possibile e promettente utilizzo in numerose aree della patologia umana, in particolare scheletrica. L'osteoma osteoide affligge frequentemente pazienti di giovane età, è una patologia benigna, con origine ed evoluzione non chiare, e trova nella termoablazione con radiofrequenza continua sotto guida CT (CT-g-RFA) il suo trattamento di elezione. Questo lavoro ha valutato l’efficacia, gli effetti e la sicurezza del trattamento dell’osteoma osteoide con MR-g-FUS. Sono stati presi in considerazione pazienti arruolati per MR-g-FUS e, come gruppo di controllo, pazienti sottoposti a CT-g-RFA, che hanno raggiunto un follow-up minimo di 18 mesi (rispettivamente 6 e 24 pazienti). Due pazienti erano stati esclusi dal trattamento MR-g-FUS per claustrofobia (2/8). Tutti i trattamenti sono stati portati a termine con successo tecnico e clinico. Non sono state registrate complicanze o eventi avversi correlati all’anestesia o alle procedure di trattamento, e tutti i pazienti sono stati dimessi regolarmente dopo 12-24 ore. La durata media dei trattamenti di MR-g-FUS è stata di 40±21 min. Da valori di score VAS pre-trattamento oscillanti tra 6 e 10 (su scala 0-10), i trattamenti hanno condotto tutti i pazienti a VAS 0 (senza integrazioni farmacologiche). Nessun paziente ha manifestato segni di persistenza di malattia o di recidiva al follow-up. Nonostante la neurolisi e la risoluzione dei sintomi, la perfusione del nidus è stata ritrovata ancora presente in oltre il 70% dei casi sottoposti a MR-g-FUS (4/6 pazienti). I risultati derivati da un'analisi estesa a pazienti più recentemente arruolati confermano questi dati. Il trattamento con MR-g-FUS sembra essere efficace e sicuro nel risolvere la sintomatologia dell'osteoma osteoide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Obstructive sleep apnoea/hypopnoea syndrome (OSAHS) is the periodic reduction or cessation of airflow during sleep. The syndrome is associated whit loud snoring, disrupted sleep and observed apnoeas. Surgery aims to alleviate symptoms of daytime sleepiness, improve quality of life and reduce the signs of sleep apnoea recordered by polysomnography. Surgical intervention for snoring and OSAHS includes several procedures, each designed to increase the patency of the upper airway. Procedures addressing nasal obstruction include septoplasty, turbinectomy, and radiofrequency ablation (RF) of the turbinates. Surgical procedures to reduce soft palate redundancy include uvulopalatopharyngoplasty with or without tonsillectomy, uvulopalatal flap, laser-assisted uvulopalatoplasty, and RF of the soft palate. More significant, however, particularly in cases of severe OSA, is hypopharyngeal or retrolingual obstruction related to an enlarged tongue, or more commonly due to maxillomandibular deficiency. Surgeries in these cases are aimed at reducing the bulk of the tongue base or providing more space for the tongue in the oropharynx so as to limit posterior collapse during sleep. These procedures include tongue-base suspension, genioglossal advancement, hyoid suspension, lingualplasty, and maxillomandibular advancement. We reviewed 269 patients undergoing to osas surgery at the ENT Department of Forlì Hospital in the last decade. Surgery was considered a success if the postoperative apnea/hypopnea index (AHI) was less than 20/h. According to the results, we have developed surgical decisional algorithms with the aims to optimize the success of these procedures by identifying proper candidates for surgery and the most appropriate surgical techniques. Although not without risks and not as predictable as positive airway pressure therapy, surgery remains an important treatment option for patients with obstructive sleep apnea (OSA), particularly for those who have failed or cannot tolerate positive airway pressure therapy. Successful surgery depends on proper patient selection, proper procedure selection, and experience of the surgeon. The intended purpose of medical algorithms is to improve and standardize decisions made in the delivery of medical care, assist in standardizing selection and application of treatment regimens, to reduce potential introduction of errors. Nasal Continuous Positive Airway Pressure (nCPAP) is the recommended therapy for patients with moderate to severe OSAS. Unfortunately this treatment is not accepted by some patient, appears to be poorly tolerated in a not neglible number of subjects, and the compliance may be critical, especially in the long term if correctly evaluated with interview as well with CPAP smart cards analysis. Among the alternative options in Literature, surgery is a long time honoured solution. However until now no clear scientific evidence exists that surgery can be considered a really effective option in OSAHS management. We have design a randomized prospective study comparing MMA and a ventilatory device (Autotitrating Positive Airways Pressure – APAP) in order to understand the real effectiveness of surgery in the management of moderate to severe OSAS. Fifty consecutive previously full informed patients suffering from severe OSAHS were enrolled and randomised into a conservative (APAP) or surgical (MMA) arm. Demographic, biometric, PSG and ESS profiles of the two group were statistically not significantly different. One year after surgery or continuous APAP treatment both groups showed a remarkable improvement of mean AHI and ESS; the degree of improvement was not statistically different. Provided the relatively small sample of studied subjects and the relatively short time of follow up, MMA proved to be in our adult and severe OSAHS patients group a valuable alternative therapeutical tool with a success rate not inferior to APAP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Recent knowledge regarding tissue biology highlights a complex regulation of growth factors in reaction to tissue damage. Platelet Rich Plasma (P.R.P.), containing a natural pool of growth factors, can be obtained in a simple and minimally invasive way and be applied to the lesion site. The aim of this study is to explore this novel approach to treat cartilage degenerative lesions of the knee and tendon chronic lesions( patellar tendon, and achilles tendon). In this study we evaluated if the treatment with PRP injections can reduce pain and increase function in cases of patellar tendinosis (Jumper’s Knee), in chronic achilles tendinopathy and in patients with cartilage injuries of the knee. Materials and Methods: 40 patients with cartilage lesion of the knee, 28 male and 12 female with mean age 47 y. (min 18- max 52 years), were treated and prospectively evaluated at a minimum 6 months follow-up; in the same way, 12 patients with achilles tendon lesion (8 male and 4 female) with mean age 44,5 y. (min 32-max 58 years) and 10 patients with “Jumper’s Knee” (8 male and 2 female) with mean age 23,2 y. (min 18-max 37 years), were evaluated at 6 months follow up. The procedure involved 3 multiple injections , performed every two weeks. All patients were clinically evaluated at the end of the treatment and at 6 months follow up. IKDC, SF36, EQ-VAS, scores were used for clinical evaluation and patient satisfaction and functional status were also recorded. Results: Statistical analysis showed a significant improvement in the SF36 questionnaire in all parameters evaluated at the end of the therapy and 6 months follow-up in both group(tendinopathies and chondral lesions), and in the EQ VAS and IKDC score (paired T-test, p<0.0005) from basal evaluation to the end of the therapy, and a further improvement was present at 6 months follow-up. Whereas a higher improvement of the sport activity level was achieved in the “Jumper’s Knee” group. No complications related to the injections or severe adverse events were observed during the treatment and follow up period. Conclusion: PRP inhibits excess inflammation, apoptosis, and metalloproteinase activity. These interactive pathways may result in the restoration of tendon or cartilage, which can with stand loading with work or sports activity, thereby diminishing pain. PRP may also modulate the microvascular environment or alter efferent or afferent neural receptors. The clinical results are encouraging, indicating that PRP injections may have the potential to increase the tendon and cartilage healing capacity in cases with chronic tendinosis and chondropathy of the knee.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dramatic impact that vascular diseases have on human life quality and expectancy nowadays is the reason why both medical and scientific communities put great effort in discovering new and effective ways to fight vascular pathologies. Among the many different treatments, endovascular surgery is a minimally-invasive technique that makes use of X-ray fluoroscopy to obtain real-time images of the patient during interventions. In this context radiopaque biomaterials, i.e. materials able to absorb X-ray radiation, play a fundamental role as they are employed both to enhance visibility of devices during interventions and to protect medical staff and patients from X-ray radiations. Organic-inorganic hybrids are materials that combine characteristics of organic polymers with those of inorganic metal oxides. These materials can be synthesized via the sol-gel process and can be easily applied as thin coatings on different kinds of substrates. Good radiopacity of organic-inorganic hybrids has been recently reported suggesting that these materials might find applications in medical fields where X-ray absorption and visibility is required. The present PhD thesis aimed at developing and characterizing new radiopaque organic-inorganic hybrid materials that can find application in the vascular surgery field as coatings for the improvement of medical devices traceability as well as for the production of X-ray shielding objects and garments. Novel organic-inorganic hybrids based on different polyesters (poly-lactic acid and poly-ε-caprolactone) and polycarbonate (poly-trimethylene carbonate) as the polymeric phase and on titanium oxide as the inorganic phase were synthesized. Study of the phase interactions in these materials allowed to demonstrate that Class II hybrids (where covalent bonds exists between the two phases) can be obtained starting from any kind of polyester or polycarbonate, without the need of polymer pre-functionalization, thanks to the occurrence of transesterification reactions operated by inorganic molecules on ester and carbonate moieties. Polyester based hybrids were successfully coated via dip coating on different kinds of textiles. Coated textiles showed improved radiopacity with respect to the plain fabric while remaining soft to the touch. The hybrid was able to coat single fibers of the yarn rather than coating the yarn as a whole. Openings between yarns were maintained and therefore fabric breathability was preserved. Such coatings are promising for the production of light-weight garments for X-ray protection of medical staff during interventional fluoroscopy, which will help preventing pathologies that stem from chronic X-ray exposure. A means to increase the protection capacity of hybrid-coated fabrics was also investigated and implemented in this thesis. By synthesizing the hybrid in the presence of a suspension of radiopaque tantalum nanoparticles, PDMS-titania hybrid materials with tunable radiopacity were developed and were successfully applied as coatings. A solution for enhancing medical device radiopacity was also successfully investigated. High metal radiopacity was associated with good mechanical and protective properties of organic-inorganic hybrids in the form of a double-layer coating. Tantalum was employed as the constituent of the first layer deposited on sample substrates by means of a sputtering technique. The second layer was composed of a hybrid whose constituents are well-known biocompatible organic and inorganic components, such as the two polymers PCL and PDMS, and titanium oxide, respectively. The metallic layer conferred to the substrate good X-ray visibility. A correlation between radiopacity and coating thickness derived during this study allows to tailor radiopacity simply by controlling the metal layer sputtering deposition time. The applied metal deposition technique also permits easy shaping of the radiopaque layer, allowing production of radiopaque markers for medical devices that can be unambiguously identified by surgeons during implantation and in subsequent radiological investigations. Synthesized PCL-titania and PDMS-titania hybrids strongly adhered to substrates and show good biocompatibility as highlighted by cytotoxicity tests. The PDMS-titania hybrid coating was also characterized by high flexibility that allows it to stand large substrate deformations without detaching nor cracking, thus being suitable for application on flexible medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present research thesis was focused on the development of new biomaterials and devices for application in regenerative medicine, particularly in the repair/regeneration of bone and osteochondral regions affected by degenerative diseases such as Osteoarthritis and Osteoporosis or serious traumas. More specifically, the work was focused on the synthesis and physico-chemical-morphological characterization of: i) a new superparamagnetic apatite phase; ii) new biomimetic superparamagnetic bone and osteochondral scaffolds; iii) new bioactive bone cements for regenerative vertebroplasty. The new bio-devices were designed to exhibit high biomimicry with hard human tissues and with functionality promoting faster tissue repair and improved texturing. In particular, recent trends in tissue regeneration indicate magnetism as a new tool to stimulate cells towards tissue formation and organization; in this perspective a new superparamagnetic apatite was synthesized by doping apatite lattice with di-and trivalent iron ions during synthesis. This finding was the pin to synthesize newly conceived superparamagnetic bone and osteochondral scaffolds by reproducing in laboratory the biological processes yielding the formation of new bone, i.e. the self-assembly/organization of collagen fibrils and heterogeneous nucleation of nanosized, ionically substituted apatite mimicking the mineral part of bone. The new scaffolds can be magnetically switched on/off and function as workstations guiding fast tissue regeneration by minimally invasive and more efficient approaches. Moreover, in the view of specific treatments for patients affected by osteoporosis or traumas involving vertebrae weakening or fracture, the present work was also dedicated to the development of new self-setting injectable pastes based on strontium-substituted calcium phosphates, able to harden in vivo and transform into strontium-substituted hydroxyapatite. The addition of strontium may provide an anti-osteoporotic effect, aiding to restore the physiologic bone turnover. The ceramic-based paste was also added with bio-polymers, able to be progressively resorbed thus creating additional porosity in the cement body that favour cell colonization and osseointegration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’aumento esponenziale del contenzioso medico-legale – originatosi negli USA negli anni Sessanta in proporzioni tali da far parlare di medical liability crisis, e sviluppatosi in Italia a partire dalla metà degli anni Ottanta – ha comportato e continua a comportare, unitamente ad altre conseguenze negative, il ricorso sempre più frequente dei sanitari alle pratiche di medicina difensiva, con elevatissimi costi a carico del Servizio Sanitario Nazionale dovuti alla sovrabbondanza di trattamenti e ricoveri inutili e di procedure diagnostiche invasive non necessarie, peraltro produttive di stress emotivo nei pazienti. La causa dell’aumento della litigiosità deve essere ricercata in buona parte nella relazione medico-paziente, in particolar modo con riferimento al momento informativo che precede l’acquisizione del consenso informato al trattamento clinico. In Italia, i limiti che per lo più caratterizzano gli studi riguardanti il consenso informato derivano principalmente dal fatto che essi tendono a focalizzarsi unicamente sulla componente scritta del medesimo. Il fulcro del consenso informato, invece, deve ritenersi rappresentato da una comunicazione tra sanitario e paziente relativa ad un trattamento proposto ed alle possibili alternative, alla non sottoposizione ad alcun trattamento e ai rischi e benefici di ciascuna di queste opzioni. In un tale contesto il tema della comunicazione tra il professionista e la persona assistita sta suscitando interesse poiché ci si aspetta che esso conduca a miglioramenti degli outcome dei pazienti e alla diminuzione delle denunce da parte di questi ultimi per casi di responsabilità sanitaria. La maggiore attenzione al rapporto medico - paziente ha fatto emergere il bisogno di migliorare e potenziare le abilità comunicative dei medici, in un’ottica in cui il momento comunicativo possa essere percepito dal professionista come fulcro del rapporto medico-paziente, nella prospettiva di una elaborazione di strategie di prevenzione e contrasto ai fenomeni di medicina difensiva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Questo studio prospettico valuta l’efficacia e i vantaggi del sistema LigasureTM rispetto alle tecniche chirurgiche tradizionali, in quattro differenti procedure eseguite su 77 cani. I soggetti sono stati suddivisi in 4 gruppi, a seconda della chirurgia eseguita: Gruppo 1, 25 pazienti sottoposti a Splenectomia “aperta” semplice; Gruppo 2, 15 pazienti sottoposti a Splenectomia “aperta” complessa; Gruppo 3, 22 pazienti sottoposti ad Ovariectomia “aperta”. Gruppo 4: 18 pazienti sottoposti a Linfoadenectomia. Ciascun gruppo è stato a sua volta suddiviso in due sottogruppi: a (LigasureTM) e b (Tradizionale), a seconda della metodica utilizzata. Sono stati analizzati: il segnalamento, i parametri ematologici, le condizioni cliniche, le informazioni riguardanti l’intervento chirurgico e l’outcome. In tutti i gruppi il ricorso all’utilizzo di garze nonché dei fili da sutura sono risultati statisticamente inferiori nei pazienti operati con il sistema a radiofrequenza (Gruppo 1, P < 0.0001; Gruppo 2, P < 0,0014; Gruppo 3, P = 0,0001; Gruppo 4, P = 0,0148). Anche i tempi per la rimozione dell’organo sono significativamente ridotti in tutti i gruppi in cui è stato utilizzato il sistema LigasureTM (Gruppo 1 P < 0.0001; Gruppo 2 P < 0,0014; Gruppo 3 P = 0,0009; Gruppo 4 P = 0,0008), come i tempi chirurgici nei gruppi 1, 2 e 3 (P = 0,0287; P = 0,0064; e P = 0,0124) ed anestesiologici nei gruppi 1a e 2a (P = 0,0176; P = 0,0043). Tra le variabili analizzate, l’utilizzo del sistema di sintesi vascolare a radiofrequenza, è l’unico ad influenzare i tempi necessari per l’esecuzione della procedura. Questo studio dimostra, quindi, come il sistema LigasureTM sia sicuro ed efficace per le procedure chirurgiche esaminate, riducendo i tempi della chirurgia e limitando, quindi, i rischi per il paziente, indipendentemente dall’operatore, dall’esecuzione di altre procedure contemporanee e dalla natura della patologia splenica o linfonodale.