5 resultados para Mean Index of Feeding intensity
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
China is a large country characterized by remarkable growth and distinct regional diversity. Spatial disparity has always been a hot issue since China has been struggling to follow a balanced growth path but still confronting with unprecedented pressures and challenges. To better understand the inequality level benchmarking spatial distributions of Chinese provinces and municipalities and estimate dynamic trajectory of sustainable development in China, I constructed the Composite Index of Regional Development (CIRD) with five sub pillars/dimensions involving Macroeconomic Index (MEI), Science and Innovation Index (SCI), Environmental Sustainability Index (ESI), Human Capital Index (HCI) and Public Facilities Index (PFI), endeavoring to cover various fields of regional socioeconomic development. Ranking reports on the five sub dimensions and aggregated CIRD were provided in order to better measure the developmental degrees of 31 or 30 Chinese provinces and municipalities over 13 years from 1998 to 2010 as the time interval of three “Five-year Plans”. Further empirical applications of this CIRD focused on clustering and convergence estimation, attempting to fill up the gap in quantifying the developmental levels of regional comprehensive socioeconomics and estimating the dynamic convergence trajectory of regional sustainable development in a long run. Four clusters were benchmarked geographically-oriented in the map on the basis of cluster analysis, and club-convergence was observed in the Chinese provinces and municipalities based on stochastic kernel density estimation.
Resumo:
Flicker is a power quality phenomenon that applies to cycle instability of light intensity resulting from supply voltage fluctuation, which, in turn can be caused by disturbances introduced during power generation, transmission or distribution. The standard EN 61000-4-15 which has been recently adopted also by the IEEE as IEEE Standard 1453 relies on the analysis of the supply voltage which is processed according to a suitable model of the lamp – human eye – brain chain. As for the lamp, an incandescent 60 W, 230 V, 50 Hz source is assumed. As far as the human eye – brain model is concerned, it is represented by the so-called flicker curve. Such a curve was determined several years ago by statistically analyzing the results of tests where people were subjected to flicker with different combinations of magnitude and frequency. The limitations of this standard approach to flicker evaluation are essentially two. First, the provided index of annoyance Pst can be related to an actual tiredness of the human visual system only if such an incandescent lamp is used. Moreover, the implemented response to flicker is “subjective” given that it relies on the people answers about their feelings. In the last 15 years, many scientific contributions have tackled these issues by investigating the possibility to develop a novel model of the eye-brain response to flicker and overcome the strict dependence of the standard on the kind of the light source. In this light of fact, this thesis is aimed at presenting an important contribution for a new Flickermeter. An improved visual system model using a physiological parameter that is the mean value of the pupil diameter, has been presented, thus allowing to get a more “objective” representation of the response to flicker. The system used to both generate flicker and measure the pupil diameter has been illustrated along with all the results of several experiments performed on the volunteers. The intent has been to demonstrate that the measurement of that geometrical parameter can give reliable information about the feeling of the human visual system to light flicker.
Resumo:
Aim: To evaluate the early response to treatment to an antiangiogenetic drug (sorafenib) in a heterotopic murine model of hepatocellular carcinoma (HCC) using ultrasonographic molecular imaging. Material and Methods: the xenographt model was established injecting a suspension of HuH7 cells subcutaneously in 19 nude mice. When tumors reached a mean diameter of 5-10 mm, they were divided in two groups (treatment and vehicle). The treatment group received sorafenib (62 mg/kg) by daily oral gavage for 14 days. Molecular imaging was performed using contrast enhanced ultrasound (CEUS), by injecting into the mouse venous circulation a suspension of VEGFR-2 targeted microbubbles (BR55, kind gift of Bracco Swiss, Geneve, Switzerland). Video clips were acquired for 6 minutes, then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated software (Sonotumor, Bracco Swiss) to quantify the signal of the contrast agent. Time/intensity curves were obtained and the difference of the mean MBs signal before and after high MI impulse (Differential Targeted Enhancement-dTE) was calculated. dTE represents a numeric value in arbitrary units proportional to the amount of bound MBs. At day +14 mice were euthanized and the tumors analyzed for VEGFR-2, pERK, and CD31 tissue levels using western blot analysis. Results: dTE values decreased from day 0 to day +14 both in treatment and vehicle groups, and they were statistically higher in vehicle group than in treatment group at day +2, at day +7, and at day +14. With respect to the degree of tumor volume increase, measured as growth percentage delta (GPD), treatment group was divided in two sub-groups, non-responders (GPD>350%), and responders (GPD<200%). In the same way vehicle group was divided in slow growth group (GPD<400%), and fast growth group (GPD>900%). dTE values at day 0 (immediately before treatment start) were higher in non-responders than in responders group, with statistical difference at day 2. While dTE values were higher in the fast growth group than in the slow growth group only at day 0. A significant positive correlation was found between VEGFR-2 tissue levels and dTE values, confirming that level of BR55 tissue enhancement reflects the amount of tissue VEGF receptor. Conclusions: the present findings show that, at least in murine experimental models, CEUS with BR55 is feasable and appears to be a useful tool in the prediction of tumor growth and response to sorafenib treatment in xenograft HCC.
Resumo:
Understanding the natural and forced variability of the atmospheric general circulation and its drivers is one of the grand challenges in climate science. It is of paramount importance to understand to what extent the systematic error of climate models affects the processes driving such variability. This is done by performing a set of simulations (ROCK experiments) with an intermediate complexity atmospheric model (SPEEDY), in which the Rocky Mountains orography is increased or decreased to influence the structure of the North Pacific jet stream. For each of these modified-orography experiments, the climatic response to idealized sea surface temperature anomalies of varying intensity in the El Niño Southern Oscillation (ENSO) region is studied. ROCK experiments are characterized by variations in the Pacific jet stream intensity whose extension encompasses the spread of the systematic error found in Coupled Model Intercomparison Project (CMIP6) models. When forced with ENSO-like idealised anomalies, they exhibit a non-negligible sensitivity in the response pattern over the Pacific North American region, indicating that the model mean state can affect the model response to ENSO. It is found that the classical Rossby wave train response to ENSO is more meridionally oriented when the Pacific jet stream is weaker and more zonally oriented with a stronger jet. Rossby wave linear theory suggests that a stronger jet implies a stronger waveguide, which traps Rossby waves at a lower latitude, favouring a zonal propagation of Rossby waves. The shape of the dynamical response to ENSO affects the ENSO impacts on surface temperature and precipitation over Central and North America. A comparison of the SPEEDY results with CMIP6 models suggests a wider applicability of the results to more resources-demanding climate general circulation models (GCMs), opening up to future works focusing on the relationship between Pacific jet misrepresentation and response to external forcing in fully-fledged GCMs.