10 resultados para ECHOCARDIOGRAPHY
em AMS Tesi di Dottorato - Alm@DL - Università di Bologna
Resumo:
Advances in stem cell biology have challenged the notion that infarcted myocardium is irreparable. The pluripotent ability of stem cells to differentiate into specialized cell lines began to garner intense interest within cardiology when it was shown in animal models that intramyocardial injection of bone marrow stem cells (MSCs), or the mobilization of bone marrow stem cells with spontaneous homing to myocardium, could improve cardiac function and survival after induced myocardial infarction (MI) [1, 2]. Furthermore, the existence of stem cells in myocardium has been identified in animal heart [3, 4], and intense research is under way in an attempt to clarify their potential clinical application for patients with myocardial infarction. To date, in order to identify the best one, different kinds of stem cells have been studied; these have been derived from embryo or adult tissues (i.e. bone marrow, heart, peripheral blood etc.). Currently, three different biologic therapies for cardiovascular diseases are under investigation: cell therapy, gene therapy and the more recent “tissue-engineering” therapy . During my Ph.D. course, first I focalised my study on the isolation and characterization of Cardiac Stem Cells (CSCs) in wild-type and transgenic mice and for this purpose I attended, for more than one year, the Cardiovascular Research Institute of the New York Medical College, in Valhalla (NY, USA) under the direction of Doctor Piero Anversa. During this period I learnt different Immunohistochemical and Biomolecular techniques, useful for investigating the regenerative potential of stem cells. Then, during the next two years, I studied the new approach of cardiac regenerative medicine based on “tissue-engineering” in order to investigate a new strategy to regenerate the infracted myocardium. Tissue-engineering is a promising approach that makes possible the creation of new functional tissue to replace lost or failing tissue. This new discipline combines isolated functioning cells and biodegradable 3-dimensional (3D) polymeric scaffolds. The scaffold temporarily provides the biomechanical support for the cells until they produce their own extracellular matrix. Because tissue-engineering constructs contain living cells, they may have the potential for growth and cellular self-repair and remodeling. In the present study, I examined whether the tissue-engineering strategy within hyaluron-based scaffolds would result in the formation of alternative cardiac tissue that could replace the scar and improve cardiac function after MI in syngeneic heterotopic rat hearts. Rat hearts were explanted, subjected to left coronary descending artery occlusion, and then grafted into the abdomen (aorta-aorta anastomosis) of receiving syngeneic rat. After 2 weeks, a pouch of 3 mm2 was made in the thickness of the ventricular wall at the level of the post-infarction scar. The hyaluronic scaffold, previously engineered for 3 weeks with rat MSCs, was introduced into the pouch and the myocardial edges sutured with few stitches. Two weeks later we evaluated the cardiac function by M-Mode echocardiography and the myocardial morphology by microscope analysis. We chose bone marrow-derived mensenchymal stem cells (MSCs) because they have shown great signaling and regenerative properties when delivered to heart tissue following a myocardial infarction (MI). However, while the object of cell transplantation is to improve ventricular function, cardiac cell transplantation has had limited success because of poor graft viability and low cell retention, that’s why we decided to combine MSCs with a biopolimeric scaffold. At the end of the experiments we observed that the hyaluronan fibres had not been substantially degraded 2 weeks after heart-transplantation. Most MSCs had migrated to the surrounding infarcted area where they were especially found close to small-sized vessels. Scar tissue was moderated in the engrafted region and the thickness of the corresponding ventricular wall was comparable to that of the non-infarcted remote area. Also, the left ventricular shortening fraction, evaluated by M-Mode echocardiography, was found a little bit increased when compared to that measured just before construct transplantation. Therefore, this study suggests that post-infarction myocardial remodelling can be favourably affected by the grafting of MSCs delivered through a hyaluron-based scaffold
Resumo:
The objective of this study was to evaluate right ventricular function in patients with right ventricular volume overload in patients with (tetralogy of Fallot, and pulmonary atresia + VSD ) underwent corrective surgery; with echocardiography measure that can be easily applied; and to study the relationship between ProBNP and the contractile function of the right ventricle, dilated right atrium, and the consequences of pulmonary insufficiency . Methods: The study included 50 patients (50% males, mean age 30.64 ± 13.30 years) with prior cardiac surgical intervention of TDF (90%) or pulmonary atresia + VSD (10%). (49 pz) have performed a cardiac MRI and clinical evaluation, (47 pz) echocardiogram, (48 pz) ECG, (34 pz) a cardiopulmonary exercise testing, (29 pz) a dosage of ProBNP. Results: The S-wave velocity (p <0.0001), the TAPSE (p <0.0001) correlated significantly with RVEF estimated by cardiac MRI. The VO2 max was 27.93 ± 12.91 ml / kg / min, 15% of patients had VE/VCO2 The peak> 35. ProBNP correlated positively and significantly with the area of the right atrium (p = 0.0001), and negative and significant with VO2 max (p = 0.04). Those who have increased pulmonary insufficiency (PVR fraction> 30%) have a significantly increased RVED volume (p = 0.01), reduced VO2 max (p = 0.04), and lower ejection fraction of LV (p = 0.02) than the group of patients with PVR ≤ 30. Conclusion: The TAPSE and S-wave velocity are fundamental and may become the technique of choice for routine assessment of RV systolic function in adult patients with TOF. The monitoring of the Pro BNP is probably a choice, given the simplicity and their information that correlate with the test cardiopulmonary. In view of the ventricular-ventricular interaction, so measures to maintain or restore the functioning of the pulmonary valve could preserve biventricular function.
Resumo:
Background: Cardiovascular disease (CVD) is a common cause of morbidity and mortality in childhood chronic kidney disease (CKD). Left ventricular hypertrophy (LVH) is known to be one of the earliest events in CVD development. Left ventricular diastolic function (DF) is thought to be also impaired in children with CKD. Tissue Doppler imaging (TDI) provide an accurate measure of DF and is less load dependent than conventional ECHO. Aim: To evaluate the LV mass and the DF in a population of children with CKD. Methods: 37 patients, median age: 10.4 (3.3-19.8); underlying renal disease: hypo/dysplasia (N=28), nephronophthisis (N=4), Alport (N=2), ARPKD (N=3), were analyzed. Thirty-eight percent of the patients were on stage 1-2 of CKD, 38% on stage 3, 16% on stage 4. Three patients were on dialysis. The most frequent factors related to CVD in CKD have been studied. LVH has been defined as a left ventricular mass index (LVMI) more than 35.7 g/h2,7. Results: Twenty-five patients (81%) had a LVH. LVMI and diastolic function index (E’/A’) were significantly related to the glomerular filtration rate (p<0.003 and p<0.004). Moreover the LVMI was correlated with the phosphorus and the hemoglobin level (p<0.0001 and p<0.004). LVH was present since the first stages of CKD (58% of patients were on stages 1-2). Early-diastolic myocardial velocity was reduced in 73% of our patients. We didn’t find any correlation between LVH and systemic hypertension. Conclusion: ECHO evaluation with TDI is suggested also in children prior to dialysis and with a normal blood pressure. If LVH is diagnosed, a periodic follow-up is necessary with the treatment of the modifiable risk factors (hypertension, disturbances of calcium, phosphorus and PTH, anemia ).
Resumo:
Obiettivo: studio longitudinale di una coorte di gravidanze gemellari e valutazione di eventuali correlazioni tra specifici parametri cardiaci materni ed esito sfavorevole della gravidanza. Metodi: Sono state arruolate in modo prospettico donne con gravidanze gemellari, sottoposte a controlli seriati della funzione cardiaca materna ( 20-23 settimane; 26-29 settimane e 30-33 settimane). Le pazienti in cui il parto si è verificato prima della 34°settimana compiuta di gestazione sono state escluse a priori dallo studio. Specifici parametri cardiaci campionati sono stati confrontati tra il gruppo di gravidanze con esito positivo ed il gruppo di pazienti che hanno sviluppato complicanze nel corso della gravidanza quali: preeclampsia o ipertensione gestazionale, basso peso alla nascita ( SGA: peso neonatale di uno o entrambi i feti < 5° centile per l’epoca di gestazione). Risultati: sono state incluse nello studio 28 gravidanze gemellari,di cui 8 complicate. Durante ogni visita abbiamo osservato un aumento significativo della gittata cardiaca ( CO ) e sistolica ( SV ) ed una caduta delle resistenze vascolari totali ( TVR ) nelle gravidanze gemellari normali vs complicate. Inoltre, CO, pressione arteriosa (BP), frequenza cardiaca ( HR ) e TVR son rimaste invariate nel corso dei controlli ambulatoriali per le gravidanze con esiti sfavorevole, mentre mostravano modificazioni significative ( CO, HR e BDP in aumento; TVR in diminuzione ) nel gruppo di pazienti con esito favorevole della gravidanza. Conclusioni: La valutazione longitudinale della funzione cardiaca materna sembra dimostrare una significativa differenza tra i valori dei parametri cardiaci materni delle gravidanze multiple non complicate, rispetto a quelle complicate da preeclampsia o neonati SGA.
Resumo:
Background Decreased exercise capacity, and reduction in peak oxygen uptake are present in most patients affected by hypertrophic cardiomyopathy (HCM) . In addition an abnormal blood pressure response during a maximal exercise test was seen to be associated with high risk for sudden cardiac death in adult patients affected by HCM. Therefore exercise test (CPET) has become an important part of the evaluation of the HCM patients, but data on its role in patients with HCM in the pediatric age are quite limited. Methods and results Between 2004 and 2010, using CPET and echocardiography, we studied 68 children (mean age 13.9 ± 2 years) with HCM. The exercise test was completed by all the patients without adverse complications. The mean value of achieved VO2 max was 31.4 ± 8.3 mL/Kg/min which corresponded to 77.5 ± 16.9 % of predicted range. 51 patients (75%) reached a subnormal value of VO2max. On univariate analysis the achieved VO2 as percentage of predicted and the peak exercise systolic blood pressure (BP) Z score were inversely associated with max left ventricle (LV) wall thickness, with E/Ea ratio, and directly related with Ea and Sa wave velocities No association was found with the LV outflow tract gradient. During a mean follow up of 2.16 ± 1.7 years 9 patients reached the defined clinical end point of death, transplantation, implanted cardioverter defibrillator (ICD) shock, ICD implantation for secondary prevention or myectomy. Patients with peak VO2 < 52% or with peak systolic BP Z score < -5.8 had lower event free survival at follow up. Conclusions Exercise capacity is decreased in patients with HCM in pediatric age and global ventricular function seems being the most important determinant of exercise capacity in these patients. CPET seems to play an important role in prognostic stratification of children affected by HCM.
Resumo:
Ultrasound imaging is widely used in medical diagnostics as it is the fastest, least invasive, and least expensive imaging modality. However, ultrasound images are intrinsically difficult to be interpreted. In this scenario, Computer Aided Detection (CAD) systems can be used to support physicians during diagnosis providing them a second opinion. This thesis discusses efficient ultrasound processing techniques for computer aided medical diagnostics, focusing on two major topics: (i) Ultrasound Tissue Characterization (UTC), aimed at characterizing and differentiating between healthy and diseased tissue; (ii) Ultrasound Image Segmentation (UIS), aimed at detecting the boundaries of anatomical structures to automatically measure organ dimensions and compute clinically relevant functional indices. Research on UTC produced a CAD tool for Prostate Cancer detection to improve the biopsy protocol. In particular, this thesis contributes with: (i) the development of a robust classification system; (ii) the exploitation of parallel computing on GPU for real-time performance; (iii) the introduction of both an innovative Semi-Supervised Learning algorithm and a novel supervised/semi-supervised learning scheme for CAD system training that improve system performance reducing data collection effort and avoiding collected data wasting. The tool provides physicians a risk map highlighting suspect tissue areas, allowing them to perform a lesion-directed biopsy. Clinical validation demonstrated the system validity as a diagnostic support tool and its effectiveness at reducing the number of biopsy cores requested for an accurate diagnosis. For UIS the research developed a heart disease diagnostic tool based on Real-Time 3D Echocardiography. Thesis contributions to this application are: (i) the development of an automated GPU based level-set segmentation framework for 3D images; (ii) the application of this framework to the myocardium segmentation. Experimental results showed the high efficiency and flexibility of the proposed framework. Its effectiveness as a tool for quantitative analysis of 3D cardiac morphology and function was demonstrated through clinical validation.
Resumo:
INTRODUCTION Echocardiography is the standard clinical approach for quantification of the severity of aortic stenosis (AS). A comprehensive examination of its overall reproducibility and the simultaneous estimation of its variance components by multiple operators, readers, probe applications, and beats have not been undertaken. METHOD AND RESULTS Twenty-seven subjects with AS were scanned over 7 months in the echo-department by a median of 3 different operators. From each patient and each operator multiple runs of beats from multiple probe positions were stored for later analysis by multiple readers. The coefficient of variation was 13.3%, 15.9%, 17.6%, and 20.2% for the aortic peak velocity (Vmax), and velocity time integral (VTI), and left ventricular outflow tract (LVOT) Vmax and VTI respectively. The largest individual contributors to the overall variability were the beat-to-beat variability (9.0%, 9.3%, 9.5%, 9.4% respectively) and that of inability of an individual operator to precisely apply the probe to the same position twice (8.3%, 9.4%, 12.9%, 10.7% respectively). The tracing (inter-reader) and reader (inter-reader), and operator (inter-operator) contribution were less important. CONCLUSIONS Reproducibility of measurements in AS is poorer than often reported in the literature. The source of this variability does not appear, as traditionally believed, to result from a lack of training or operator and reader specific factors. Rather the unavoidable beat-to-beat biological variability, and the inherent impossibility of applying the ultrasound probe in exactly the same position each time are the largest contributors. Consequently, guidelines suggesting greater standardisation of procedures and further training for sonographers are unlikely to result in an improvement in precision. Clinicians themselves should be wary of relying on even three-beat averages as their expected coefficient of variance is 10.3% for the peak velocity at the aortic valve.
Resumo:
In corso di gravidanza normale avvengono modificazioni emodinamiche centrali e periferiche volte a garantire le crescenti richieste nutritive dell'unità feto-placentare. L’ecografia con mezzo di contrasto (CEUS-Contrast Enhanced Ultrasonography) a base di microbolle offre una nuova opportunità di monitorare e quantificare la perfusione utero-placentare in condizioni normali e patologiche. L’ecocardiografia è stata ampiamente usata in medicina umana per valutare l’adattamento morfo-funzionale cardiaco materno durante la gravidanza. Gli scopi di questo lavoro prospettico sono stati di applicare, per la prima volta nella specie equina, un mezzo di contrasto di II generazione (Sonovue®), al fine quantificare la perfusione utero-placentare in corso di gravidanza normale, valutandone gli effetti sul benessere materno-fetale e di descrivere le modificazioni nei parametri ecocardiografici morfometrici e funzionali cardiaci, in particolare relativi alla funzione del ventricolo sinistro nel corso di una gravidanza fisiologica. Due fattrici sane di razza Trottatore sono state monitorate ecograficamente in maniera seriale durante l’intero corso della gravidanza, tramite esame bidimensionale, ecocontrastografia dell'unità utero-placentare, flussimetria Doppler delle arterie uterine, ecocardiografia materna in modalità bidimensionale, M-mode, Doppler e Tissue Doppler Imaging. I neonati sono stati clinicamente monitorati e gli invogli fetali esaminati. Il pattern di microperfusione utero-placentare è valutabile quali-quantitativamente tramite la CEUS e dimostra un’aumento del flusso a livello di microvascolarizzazione uterina con l'avanzare della gravidanza; non è stata rilevata la presenza di microbolle a livello di strutture fetali nè effetti dannosi sul benessere materno-fetale. In questo studio sono state osservate delle modificazioni cardiache materne in corso di gravidanza fisiologica, relative all'aumento della FC, del CO ed in particolare all'aumento delle dimensioni dell'atrio sinistro ed a modificazioni nelle onde di velocità di flusso e tissutali di riempimento del ventricolo sinistro.
Resumo:
Scopo dello studio: la cardiomiopatia aritmogena (CA) è conosciuta come causa di morte improvvisa, la sua relazione con lo scompenso cardiaco (SC) è stata scarsamente indagata. Scopo dello studio è la definizione della prevalenza e incidenza dello SC, nonché della fisiopatologia e delle basi morfologiche che conducono i pazienti con CA a SC e trapianto di cuore. Metodi: abbiamo analizzato retrospettivamente 64 pazienti con diagnosi di CA e confrontato i dati clinici e strumentali dei pazienti con e senza SC (NYHA III-IV). Abbiamo analizzato i cuori espiantati dei pazienti sottoposti a trapianto presso i centri di Bologna e Padova. Risultati: la prevalenza dello SC alla prima osservazione era del 14% e l’incidenza del 2,3% anno-persona. Sedici pazienti (23%) sono stati sottoposti a trapianto. I pazienti con SC erano più giovani all’esordio dei sintomi (46±16 versus 37±12 anni, p=0.04); il ventricolo destro (VD) era più dilatato e ipocinetico all’ecocardiogramma (RVOT 41±6 versus 37±7 mm, p=0.03; diametro telediastolico VD 38±11 versus 28±8 mm, p=0.0001; frazione di accorciamento 23%±7 versus 32%±11, p= 0.002). Il ventricolo sinistro (VS) era lievemente più dilatato (75±29 ml/m2 versus 60±19, p= 0.0017) e globalmente più ipocinetico (frazione di eiezione = 35%±14 versus 57%±12, p= 0.001). Il profilo emodinamico dei pazienti sottoposti a trapianto era caratterizzato da un basso indice cardiaco (1.8±0.2 l/min/m2) con pressione capillare e polmonare tendenzialmente normale (12±8 mmHg e 26±10 mmHg). L’analisi dettagliata dei 36 cuori dei pazienti trapiantati ha mostrato sostituzione fibro-adiposa transmurale nel VD e aree di fibrosi nel VS. Conclusioni: Nella CA lo SC può essere l’unico sintomo alla presentazione e condurre a trapianto un rilevante sottogruppo di pazienti. Chi sviluppa SC è più giovane, ha un interessamento del VD più severo accanto a un costante interessamento del VS, solo lievemente dilatato e ipocinetico, con sostituzione prevalentemente fibrosa.
Resumo:
The aim of the Research of this Ph D Project is to improve the medical management after surgery for advanced heart failure, both after left ventricular assist devices (LVAD) implantation, and after heart transplantation in the long-term. Regarding heart transplantation (HTx), the Research Project is focused on diagnostics, classification, prevention and treatment of cardiac allograft vasculopathy (CAV), and on treatment of post-HTx cancers; the results are presented in the first part of this Thesis. In particular, the main aspect investigated are the prognostic role of information derived from coronary angiography, coronary tomography and intravascular ultrasound, and the different sensitivity of these techniques in predicting outcomes and in diagnosing CAV. Moreover, the role of mTOR inhibitors on CAV prevention or treatment is investigated, both alone and in combination with different anti-CMV prevention strategies, as well as the impact of mTOR inhibitors on clinical outcomes in the long term. Regarding LVAD, the main focus is on the role of transthoracic echocardiography in the management of patients with a continuous-flow, centrifugal, intrapericardial pump (HVAD, Heartware); this section is reported in the second part of this Thesis. The main aspects investigated are the use of echocardiography in patients with HVAD device and its interaction with the information derived from pump curves' analysis in predicting aortic valve opening status, a surrogate of the condition of support provided by the LVAD.